● power management for reducing power consumption when the computer is not in use
● compliance with the recommendations in accordance with TCO’03
In normal screen mode (dark characters against a light background) the monitor satisfies the
ergonomic requirements for the GS symbol.
This operating manual contains important information you require to start up and run your LCD
monitor.
A graphics card (screen controller) with VGA interface or a digital graphics card with DVI interface is
required to control the SCALEOVIEW S17-2 / S19-2 LCD monitor. The monitor processes the data
supplied to it by the screen controller. The screen controller/the associated driver software is
responsible for setting the modes (resolution and refresh rate).
When putting the monitor into operation for the first time, the screen display should be optimally
adapted to the screen controller used and adjusted in accordance with your needs (see the
"Changing the monitor settings" section in the "Operation of the monitor" chapter).
Target group
You don't need to be an "expert" to perform the operations described here. However, please observe
the safety information given in the operating instructions of the computer and in this manual.
In the event of any problems occurring, please contact your sales outlet or our help desk.
A26361-K1018-Z120-1-7619, edition 1 1
SCALEOVIEW S17-2 / S19-2
Notational conventions
The meanings of the symbols and fonts used in this manual are as follows:
Pay particular attention to texts marked with this symbol. Failure to observe this warning
!
endangers your life, destroys the system, or may lead to loss of data.
i
►Text which follows this symbol describes activities that must be performed in the order shown.
"Quotation marks" indicate names of chapters or terms.
This font indicates filenames and menu items.
This font indicates screen outputs.
Additional information
Details of how you set the resolution and refresh rate are provided in the documentation on your
screen controller/the associated driver software.
Supplementary information, remarks, and tips follow this symbol.
Important notes
In this chapter you will find information regarding safety which is essential to take note of
!
Safety notes
This device complies with the relevant safety regulations for data processing equipment, including
electronic office machines for use in an office environment. If you have any questions, contact your
sales outlet or our help desk.
with your monitor.
●The display surface of the LCD monitor is sensitive to pressure and scratches. You should
therefore be careful with the display surface so as to avoid lasting damage (Newton rings,
scratches).
●If the device is brought into the installation site from a cold environment, condensation can
form. Before operating the device, wait until it is absolutely dry and has reached approximately
the same temperature as the installation site.
●During installation and before operating the device, please observe the instructions on
environmental conditions in the "Technical data" chapter as well as the instructions in the
"Installing an ergonomic video workstation" chapter.
●To ensure sufficient ventilation, the intake and exhaust air openings of the monitor must never
be blocked.
2A26361-K1018-Z120-1-7619, edition 1
SCALEOVIEW S17-2 / S19-2
●The monitor automatically sets itself to a mains voltage in the range of 100 V to 240 V. Ensure
that the local mains voltage lies within these limits.
● Ensure that the power socket on the device or the grounded mains outlet is freely accessible.
● The ON/OFF switch does not disconnect the device from the mains voltage. To completely
disconnect the mains voltage, remove the power plug from the socket.
● The monitor is equipped with a power cable that complies with safety standards.
● Lay all cables so that nobody can stand on them or trip over them. When attaching the device,
observe the relevant notes in the "Connecting the monitor" chapter.
●If you use a different data cable from the one supplied, ensure that it is adequately shielded.
CE conformance and optimum picture quality are guaranteed only if you use the data cables
supplied.
● No data transfer cables should be connected or disconnected during a thunderstorm.
● Make sure that no objects (e.g. jewellery chains, paper clips, etc.) or liquids get inside the
device (danger of electric shock, short circuit).
●The device is not waterproof! Never immerse the device in water and protect it from spray
water (rain, sea water).
●In emergencies (e.g. damaged casing, elements or cables, penetration of liquids or foreign
matter), switch off the unit, disconnect the power plug and contact your sales outlet or our help
desk.
●The monitor must be disposed of in accordance with the local regulations for disposal of
special waste. The screen background lighting contains mercury. You must observe the
applicable handling and disposal safety regulations for fluorescent tubes.
●Only qualified technicians should repair the device. Unauthorised opening and incorrect repair
may greatly endanger the user (electric shock, fire risk).
●You may set only those resolutions and refresh rates specified in the "Technical data" chapter.
Otherwise you may damage your monitor. If you are in any doubt, contact your sales outlet or
our help desk.
●Use a screen saver with moving images and activate the power management for your monitor
to prevent still images from "burning in".
●This device must be operated with the provided power supply. Never cover a power adapter
that is in use.
A26361-K1018-Z120-1-7619, edition 1 3
SCALEOVIEW S17-2 / S19-2
Power cable
To guarantee safe operation, use the cable supplied. Use the following guidelines if it is necessary to
replace the original cable set.
● The female/male receptacles of the cord set must meet IEC60320/CEE-22 requirements.
● The cable has to be HAR-certified or VDE-certified. The mark HAR or VDE will appear on the
outer sheath.
●For devices which are mounted on a desk or table, type SVT or SJT cable sets may be used.
For devices which sit on the floor, only SJT type cable sets may be used.
● The cable set must be selected according to the rated current for your device.
● If necessary, replace the original power cable with a regular grounded 3-core mains lead.
Transport
●Transport the monitor with care and only in its original packaging or another corresponding
packaging fit to protect it against knocks and jolts.
●Never drop the LCD monitor (danger of glass breakage).
Cleaning
● Always pull out the power plug before you clean the monitor.
● Do not clean any interior parts yourself, leave this job to a service technician.
● Do not use any cleaning agents that contain abrasives or may corrode plastic.
● Ensure that no liquid will run into the system.
● Ensure that the ventilation areas of the monitor are free.
● The display surface of the LCD monitor is sensitive to pressure and scratches. Clean it only
using a soft, slightly moistened cloth.
Wipe the monitor casing with a dry cloth. If the monitor is particularly dirty, use a cloth which has
been moistened in mild domestic detergent and then carefully wrung out.
4A26361-K1018-Z120-1-7619, edition 1
SCALEOVIEW S17-2 / S19-2
CE marking
The shipped version of this device complies with the requirements of the EEC directives
89/336/EEC "Electromagnetic compatibility" and 73/23/EEC "Low voltage directive".
FCC Class B Compliance Statement
The following statement applies to the products covered in this manual, unless otherwise specified
herein. The statement for other products will appear in the accompanying documentation.
NOTE:
This equipment has been tested and found to comply with the limits for a "Class B" digital device,
pursuant to Part 15 of the FCC rules and meets all requirements of the Canadian InterferenceCausing Equipment Standard ICES-003 for digital apparatus. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in strict
accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
● Reorient or relocate the receiving antenna.
● Increase the separation between equipment and the receiver.
● Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
●Consult the dealer or an experienced radio/TV technician for help.
Fujitsu Siemens Computers GmbH is not responsible for any radio or television interference caused
by unauthorised modifications of this equipment or the substitution or attachment of connecting
cables and equipment other than those specified by Fujitsu Siemens Computers GmbH. The
correction of interferences caused by such unauthorised modification, substitution or attachment will
be the responsibility of the user.
The use of shielded I/O cables is required when connecting this equipment to any and all optional
peripheral or host devices. Failure to do so may violate FCC and ICES rules.
A26361-K1018-Z120-1-7619, edition 1 5
SCALEOVIEW S17-2 / S19-2
Energy Star Guidelines
The Fujitsu Siemens LCD colour monitor SCALEOVIEW S17-2 / S19-2 is
designed to conserve electricity by dropping to less than 5 W when it goes
into standby, suspend and OFF mode. With this new power management
the monitor SCALEOVIEW S17-2 / S19-2 qualifies for the U.S.
Environmental Protection Agency's (EPA) Energy Star Computers award.
The EPA estimates that computer equipment uses 5 % percent of all business electricity and that
this is growing rapidly. If all desktop computers and peripherals enter a low-power mode when not in
use, the overall savings in electricity could amount to $ 2 thousand million annually. These savings
could also prevent the emission of 20 million tons of carbon dioxide into the atmosphere - the
equivalent of 5 million automobiles.
As an Energy Star Partner, Fujitsu Siemens Computers GmbH has determined that this product
meets the Energy Star guidelines for energy efficiency.
Disposal and recycling
This device has been manufactured to the highest possible degree from materials which can be
recycled or disposed of in a manner that is not environmentally damaging. The device may be taken
back after use to be recycled, provided that it is returned in a condition that is the result of normal
use. Any components not reclaimed will be disposed of in an environmentally acceptable manner.
If you have any questions on disposal, please contact your local office, our help desk, or:
SWICO
Schweizerischer
Wirtschaftsverband der
Informations-,
Kommunikations- und
Organisationstechnik
A list of the SWICO
Acceptance places can be
found at:
http://www.swico.ch
6A26361-K1018-Z120-1-7619, edition 1
SCALEOVIEW S17-2 / S19-2
Checking the contents of the consignment
The display surface of the LCD monitor is sensitive to pressure and scratches. Always
!
► Unpack all the individual parts.
► Check the delivery for damage incurred during transportation.
► Check whether the delivery agrees with the details in the delivery note.
hold the device by the casing!
The complete LCD monitor package includes:
– one monitor
– one data cable (D-SUB / DVI-I)
– one data cable (DVI-D/ DVI-D)
– one power cable
– one audio cable
– one power adapter with power adapter cable
– a CD with software for the picture calibration of the monitor
– one Warranty Booklet
– one "Getting Started" manual
Should you discover that the delivery does not correspond to the delivery note, notify your local sales
outlet immediately.
We recommend that you keep the original packaging material. You may need the
i
packaging in the future if you need to transport your device.
A26361-K1018-Z120-1-7619, edition 1 7
SCALEOVIEW S17-2 / S19-2
Installing an ergonomic video workstation
Before you set up your equipment, you should select a suitable position for working at the monitor.
Please observe the following advice when installing a video workstation.
1
1
600 mm600 mm
2
2
1 = Windows
Avoid direct and reflected glare.
Avoid glare from electric
lighting.
1 = Edge of desk
2 = Permissible reaching
sector
Position the keyboard where it
is easiest to reach.
Position the monitor for
optimum viewing. The viewing
Keep ventilated areas clear.
1 = approx. 90° and more
2 = approx. 90°
Remember to maintain correct
posture.
distance to the monitor should
be approximately 50 cm.
Depending on the situation, the use of a swivel arm or wall bracket (VESA FPMPMI), are available
from specialised dealers, may be advisable. For this purpose the monitor base must be removed
beforehand as described in the "Mounting and removing the monitor base" chapter.
8A26361-K1018-Z120-1-7619, edition 1
SCALEOVIEW S17-2 / S19-2
Mounting and removing the monitor base
The monitor surface is susceptible to scratching! Therefore, lay the monitor on a soft
!
Folding out monitor base
When delivered the lower part of the monitor base is folded in.
surface when mounting or removing the monitor base.
►Lay the monitor on its face on a soft
surface.
►Fold the monitor base in the direction of the
arrow until it engages noticeably.
A26361-K1018-Z120-1-7619, edition 1 9
SCALEOVIEW S17-2 / S19-2
Removing monitor base
Before you can use a swivel arm or a wall bracket, you must remove the monitor base:
►Lay the monitor on its face on a soft surface.
!
!
If you want to mount the monitor base again, hook the monitor base on the rear of the monitor and
press the monitor base towards the rear panel, it clicks into position.
The monitor surface is susceptible to scratching!
►Push a screwdriver through the opening on
the monitor base.
►Push the spring with a screwdriver towards
the hinge and lift off the monitor base.
You can now mount a swivel arm or a wall
bracket as per VESA FPMPMI with 75 mm hole
spacing. For instructions on how to mount the
swivel arm or wall bracket, please see the
documentation for the swivel arm or wall bracket.
The thermal dissipation on the rear wall of the casing must not prevented by shielding.
Therefore, make sure that the distance to the wall or pieces of furniture is long enough.
Installation/Deinstallation of the loudspeaker module
Installation
►Align the loudspeaker module that the two
hooks slot into the two openings on the
bottom of the monitor.
►Engage the loudspeaker module.
Uninstallation
►Press the two push-buttons on the rear of
the monitor and remove the loudspeaker
module downward.
10A26361-K1018-Z120-1-7619, edition 1
SCALEOVIEW S17-2 / S19-2
Connecting the monitor
Please take note of the safety information in the "Important notes" chapter.
!
► Be sure that the monitor and the computer are switched off.
Connecting cables to the monitor
CE conformance and optimum picture quality are guaranteed only if you use the data
cables supplied.
Do not cover the ventilation openings of the monitor.
The computer power plug must be pulled out!
1 = Connector for the power supply
2 = DVI connector (DIGITAL)
3 = AUDIO-IN connector
4 = AUDIO-IN connector
5 = Push-buttons to remove the loudspeaker
module
6 = Security slot for "Kensington Lock"
1234
6
5
The data cables provided have a plug for the DVI connection socket on the monitor and a D-SUB
plug or a DVI plug for the connection on the computer.
Select the suitable data cable for your computer.
Digital graphics card with DVI interface: DVI connector
Graphics card with VGA interface: D-SUB connector
Information on the computer connections and interfaces is contained in the operating manual for your
computer.
►Connect the angled connector of the data cable to the DVI connector on the monitor (2) and
secure the plug-in connection by tightening the safety screws.
►Plug the power adapter cable into the power connector (1) of the monitor.
A26361-K1018-Z120-1-7619, edition 1 11
SCALEOVIEW S17-2 / S19-2
►Firmly insert the socket with the power cable supplied into the power cable connection of the
power adapter and check whether the socket is securely seated.
A lock (Kensington Lock) can be mounted in the security slot (6) to protect the monitor
i
from theft. A Kensington Lock is not included in the consignment of the monitor.
Connecting cables to the computer
Information on the computer connections and interfaces is contained in the operating manual for your
computer.
If your computer has two monitor ports ("onboard" screen controller and separate
i
► Connect the even connector of the data cable to the active monitor port on the computer and
► Connect the connector of the power cable supplied into a properly earthed mains outlet and
graphics card), the monitor port for the separate graphics card is usually active.
secure the plug-in connection by tightening the safety screws.
ensure a secure connection.
►Plug the power connector of the computer into a properly grounded mains outlet.
When you start working with your monitor for the first time you should install the
i
appropriate graphics drivers for your application software. Details of how to do this are
provided in the documentation on your screen controller/the associated driver software.
Operation of the monitor
The monitor offers the following possibilities that enable it to be optimally adjusted for the respective
user and the respective situation.
Adjusting rake and height
Adjusting rake
The rake of the monitor can be adjusted by 0° (forward) and +20° (back) from its vertical position.
►Grasp the monitor with both hands on the right and left edge of the casing and adjust it to the
desired rake.
12A26361-K1018-Z120-1-7619, edition 1
SCALEOVIEW S17-2 / S19-2
Adjusting height
The height of the monitor can be adjusted (six
positions).
►Grasp the monitor by the handle on the
back and pull it in the direction of the arrow
into the desired position.
►If you want to reduce the height, press the
button for the height adjustment (1) repeatedly if necessary.
The monitor base engages one position lower
each time the button is pressed.
1
Switching the monitor on/off
1 = Buttons for the OSD menu
(On-Screen-display)
2 = Power indicator
3 = ON/OFF switch
1 2
3
The ON/OFF switch (3) is used for switching the monitor on and off.
The power indicator (2) lights up blue when the monitor and computer are switched on. The power
indicator lights up orange when the monitor does not receive a video signal or is in the energy saving
mode. The power indicator goes off when the monitor is switched off.
A26361-K1018-Z120-1-7619, edition 1 13
SCALEOVIEW S17-2 / S19-2
When you switch the computer system on, you must proceed in the following order:
► First switch on the LCD monitor with the ON/OFF switch (3).
► Then switch on the computer.
If your computer has a power management function (energy-saving mode), you should
i
read the "Notes on power management" section in this chapter.
Notes on power management
If your computer is equipped with power management, the monitor can support this function fully.
Here the monitor does not distinguish between the individual energy-saving modes of the computer
(standby mode, suspend mode and OFF mode), as it is capable of immediately switching into the
mode with the highest energy-saving effect.
Stage ON Power-Saving Mode
Power indicator lights up blue lights up orange
Function the monitor is working
normally
Power consumption typical 35 W (S17-2)
typical 48 W (S19-2)
If your computer detects inactivity (no input) it sends an appropriate signal to the monitor to reduce
the power consumption (energy-saving mode). The power indicator of the monitor changes colour to
indicate the status change.
Once an input is made at the computer the screen contents are redrawn and full power is restored.
For detailed information on how energy-saving mode operates refer to the operating manual or
technical manual of the computer.
When the monitor is switched to the energy-saving mode by the power management
i
system a power consumption of up to 5 W is maintained to feed the circuit for redrawing
the screen contents.
To completely switch off the power consumption, switch off the computer or pull the plug of
the monitor power cable out of the monitor socket of the computer.
the screen is dark
reduced to < 5 W
Changing the monitor settings
When putting the monitor into operation for the first time, the screen display should be optimally
adapted to the screen controller used and adjusted in accordance with your needs.
Basic monitor settings with the CD supplied
If one of the operating systems Windows 95/98, Windows NT, Windows Me, Windows 2000,
Windows XP or OS/2 (with Windows emulation installed) is used, the basic monitor settings can be
set with the CD supplied.
► Insert the supplied CD into the CD-ROM drive.
► Open the Readme file on the CD and follow the instructions in the file.
14A26361-K1018-Z120-1-7619, edition 1
SCALEOVIEW S17-2 / S19-2
Your monitor should now already be properly adjusted. If none of the above operating systems is
used or minor corrections are to be made to the screen display, then change the monitor settings
with the OSD menu.
Changing the monitor settings with the buttons of the control panel
MENU/SEL
Use the buttons of the control panel to make the following monitor settings directly while the OSD
menu is switched off.
Performing auto-adjustment of the monitor
►Press the AUTO/EXIT button for approx. 1 second while the OSD menu is switched off.
The Auto Processing message is displayed.
Picture quality and position are set to optimum values for your system.
Adjusting background lighting
► Press the 5 button for calling the Brightness setting window.
► Press the 6 button for calling the Contrast setting window.
A message is displayed that the action has been performed.
This setting window can also be called, when the OSD menu is locked.
Locking the OSD menu
DOWNUP
AUTO/EXITPOWER
The OSD menu can be locked to prevent accidental or unauthorised changes to the monitor settings.
►Press and hold the MENU/SEL button for a few seconds while you switch on the monitor with
the ON/OFF switch.
A message is displayed that the action has been performed.
Please proceed in the same manner to release the locked OSD menu again.
A26361-K1018-Z120-1-7619, edition 1 15
SCALEOVIEW S17-2 / S19-2
Monitor settings using the OSD menu
With the buttons on the control panel, call up and use the integrated OSD (On-Screen display) menu.
The OSD menu is available in different languages. The English menu names are used in
i
To set the OSD menu, perform the following steps:
►Press the MENU/SEL button to activate the OSD menu.
The main menu appears on the screen (on the left-hand side) with icons for the setting functions.
the following description (default setting). With the OSD function Language in the OSD Setup
you can select another language.
The first symbol (Brightness/Contrast) is
highlighted. In the right-hand part of the display
the associated functions are shown.
►If necessary, press the 6 or 5 button to
mark another icon (e.g. Image adjust).
►Press the MENU/SEL button to select the
highlighted icon.
The corresponding setting window (here: Image Adjust) is displayed (on the right-hand side).
16A26361-K1018-Z120-1-7619, edition 1
SCALEOVIEW S17-2 / S19-2
All changes are stored automatically.
The first function (H-Position) is highlighted.
►If necessary, press the 6 or 5 button to
mark another function.
►Press the MENU/SEL button to select the
highlighted function.
► Press the 6 or 5 button to adjust the value
for the selected function.
►Press the AUTO/EXIT button to exit the
function.
►If necessary, press the button 6 or 5 to
mark another function or press the
AUTO/EXIT button to return to the main
menu.
If you want to change other settings, select the corresponding function from the OSD main menu. All
possible adjustments of the main menu are described in the following.
Adjusting the brightness and contrast
Calling the Brightness / Contrast setting window.
Brightness
Setting the brightness of the display
With this function you change the brightness of the background lighting.
Contrast
Setting the contrast of the display
With this function you modify the contrast of bright colour tones.
Auto Level
Setting the brightness of the display
With this function you can automatically set the contrast.
Press the MENU/SEL button to activate the function.
If the contrast is set too high, bright surfaces can no longer be distinguished from very
i
bright surfaces. If the contrast is set too low, the maximum brightness will not be achieved.
A26361-K1018-Z120-1-7619, edition 1 17
SCALEOVIEW S17-2 / S19-2
Adjusting size and position
Calling the Image adjust setting window
H-Position
Adjusting the horizontal position
With this function you move the picture to the left or to the right.
V-Position
Adjusting the vertical position
With this function you move the picture up or down.
Clock
Setting synchronisation
With this function you adjust the picture width to eliminate vertical picture
disturbances.
Phase
Eliminating picture interference
With this function you fine-tune your monitor to eliminate picture interference.
Adjusting the volume
Calling the Audio setting window
Volume
Mute
Setting the volume for playback with the integrated loudspeakers
Switching the loudspeakers off or on
Setting colour temperature and colours
Calling the Colour setting window
Selecting the colour temperature
The "warmth" of the screen colours is set using the colour temperature. The colour
temperature is measured in K (= Kelvin). You can select from 6500 K, 9300 K, Native
and Custom Colour.
Native
Custom Colour
= Original colour of the LCD display
= User-defined colours
In the user-defined setting you can change the colour ratios of the basic colours
(red, green, blue) as required.
18A26361-K1018-Z120-1-7619, edition 1
SCALEOVIEW S17-2 / S19-2
Setting display of the OSD menu
Calling the OSD Setup setting window
Language
Setting language for the OSD menu
With this function you select the language for the OSD menu. The following
languages are offered:
English Italian Russian
OSD
H-Position
OSD
V-Position
OSD
Timeout
Setting the horizontal position of the OSD menu
With this function you move the OSD menu to the left or to the right.
Setting the vertical position of the OSD menu
With this function you move the OSD menu up or down.
Setting the display duration of the OSD menu
With this function you select a value from 10 to 120 seconds.
If the set time expires without a setting being made, the OSD menu is automatically
faded out.
Setting functions in the "Advanced " menu
Calling the Advanced setting window
French Swedish English (default setting)
Spanish Dutch
Resolution
Notifier
Displaying monitor data
The optimum resolution for this monitor is 1280 x 1024 pixels. With the function
activated (On), a message appears on the screen after approx. 30 seconds if a
different resolution is set.
Change the resolution to 1280 x 1024 to achieve optimum picture quality. With the
function deactivated (Off), no message appears.
Factory Recall
Activating the factory settings
With this function all settings are reset to the factory settings without prompting for
confirmation.
Press the MENU/SEL button to activate the function. The Auto Processing message
is displayed.
Displaying information
Calling the Information setting window
With this function the model designation, serial number, resolution, H/V frequency,
input signal and polarity of the synchronisation signal are displayed.
A26361-K1018-Z120-1-7619, edition 1 19
SCALEOVIEW S17-2 / S19-2
Notes on ergonomic colour adjustment
If you select colours for the display in your application programmes, take note of the information
below.
The primary colours blue and red on a dark background do not produce the minimum required
contrast of 3:1 and are therefore not suitable for continuous text and data entry.
When using several colours for characters and background and giving the primary colours full
modulation, you can obtain very suitable colour combinations (see the following table):
Background
black white purple blue cyan green yellow red
black + + - + + + -
white + + + - - - +
purple + + - - - - -
blue - + - + - + -
cyan + - - + - - -
green + - - + - - -
yellow + - + + - - +
red - + - - - - +
+ Colour combination very suitable
- Colour combination not suitable because colour locations are too close together, thin characters
are not identifiable or rigorous focusing is demanded of the human eye.
Characters
20A26361-K1018-Z120-1-7619, edition 1
SCALEOVIEW S17-2 / S19-2
Troubleshooting
Should an error occur, first check the following points. If the distortion is still not eliminated, the
monitor should, if possible, be checked on another computer and/or with another data cable.
If you are unable to solve the problem, please inform our help desk.
Having this problem? Check the following points:
No screen display
(power indicator does not light)
No screen display
(power indicator lights)
Message:
No Signal
Message:
Frequency out of range:
## kHz / ## Hz
Please change the display mode to
1280x1024 with 60 Hz.
► Check whether the monitor is switched on.
► Check whether the power cable on the
monitor is connected correctly.
► Check whether the computer is switched on.
► Check whether the computer is switched on.
► Check whether the data cable for the monitor
is correctly attached to the monitor port on the
computer.
►Press any key on the computer keyboard - the
computer may be in energy saving mode.
►Alter the brightness and/or contrast until you
get a picture.
►Check whether the data cable for the monitor
is correctly attached to the monitor port on the
computer.
►Check whether the computer is switched on.
The input signal (horizontal frequency and refresh
rate) at the displayed input does not correspond to
the technical monitor data.
►Adjust the video frequency range using the
computer software (see documentation for
your computer or your graphics card).
Picture position is not correct The monitor recognises an undefined mode (see
A26361-K1018-Z120-1-7619, edition 1 21
the "Technical data" chapter).
►Press the AUTO/EXIT button to perform the
auto-adjustment of the screen.
►Set the picture position with the OSD menu
(see the "Operation of the monitor" chapter).
SCALEOVIEW S17-2 / S19-2
Having this problem? Check the following points:
Picture is shaking ►Check whether the data cable for the monitor
is correctly attached to the monitor port on the
computer.
►Press the AUTO/EXIT button to perform the
auto-adjustment of the screen.
Picture is wrongly adjusted ►Press the MENU/SEL button to activate the
function Factory Recall. The Auto Processing
message is displayed.
The background lighting has a limited lifetime. If
your monitor display should become too dark, the
background lighting will have to be exchanged.
►Please contact our help desk.
Permanently unlit or lit pixels
The standard of production techniques today cannot guarantee an absolutely fault-free screen
display. A few isolated constant lit or unlit pixels may be present. The maximum permitted number of
pixels faults is stipulated in the stringent international standard ISO 13406-2 (Class II).
Example: a 17" flat-screen monitor with a resolution of 1280 x 1024 has 1280 x 1024 = 1310720
pixels. Each pixel consists of three subpixels (red, green and blue), so there are almost 4 million dots
in total.
According to ISO 13406-2 (Class II), a maximum of 6 pixels and 7 subpixels may be defective, i. e. a
total of 25 faulted dots. This corresponds to approx. 0.00062 % of the entire screen surface!
22A26361-K1018-Z120-1-7619, edition 1
SCALEOVIEW S17-2 / S19-2
Technical data
Dimensions and weight (LCD monitor)
S17-2 S19-2
Visible diagonals: 43 cm 48 cm
Dot pitch: 0.264 mm 0.294 mm
Screen size: Width:
Height:
Maximal resolution: 1280 x 1024 1280 x 1024
Dimensions
incl.
monitor base:
Weight (without packaging): approx. 5.9 kg approx. 6.45 kg
Accessories: Audio cable (1.8 m)
Storable display modes: 20, 9 of which are preset
Electrical data
Video: analogue, positive, 0.7 V
Synchronisation: Separate Sync. TTL, positive or negative
Width:
Height:
Depth:
Width:
Height:
Depth:
Data cable D-SUB/DVI-I (1.8 m)
Data cable DVI-D/DVI-D (1.8 m)
Power cable (1.8 m)
Power adapter with power adapter cable
337.9 mm
270.3 mm
397 mm
395 - 475 mm
207 mm
450 mm
425 mm
170 mm
, 75 Ω
pp
376 mm
301 mm
416 mm
425 - 505 mm
207 mm
534 mm
543 mm
170 mm
Horizontal frequency: 31 kHz .... 80 kHz (multi-scanning) with analogue signal
31 kHz .... 64 kHz (multi-scanning) with digital signal
Refresh rate: 56 Hz .... 76 Hz
Maximum pixel rate: 135 MHz with analogue signal
110 MHz with digital signal
Power supply: power adapter; switches automatically
100 V - 240 V, 50 Hz - 60 Hz
Total power consumption: 35 W (S17-2) typical
48 W (S19-2) typical
< 5 W in energy-saving mode (OFF mode)
Audio output: 2 x 3 W
A26361-K1018-Z120-1-7619, edition 1 23
± 2 Hz, 1.5 A - 0.7 A
SCALEOVIEW S17-2 / S19-2
Environmental conditions
Environment class 3K2, IEC 721
Rated range of operation:
Humidity:
Limit range of operation:
Humidity:
Condensation must be avoided.
15 °C .... 35 °C
20 % .... 85 %
5 °C .... 35 °C
20 % .... 85 %
VESA-DDC-compatible VGA interface
Your monitor is equipped with a VESA-DDC-compatible VGA interface. VESA-DDC (Video
Electronics Standard Association, Display Data Channel) is used as the communications interface
between the monitor and the computer. If your computer is equipped with a VESA-DDC-compatible
VGA interface, it can automatically read the data for ensuring optimum operation from your monitor
and select the appropriate settings.
If the monitor SCALEOVIEW S17-2 / S19-2 is not yet displayed in the list of monitors, you
The picture position and size have been set to optimum values at the factory for the
i
The following are the most frequently used of the preset operating modes:
For ergonomic reasons, a screen resolution of 1280 x 1024 pixels is recommended. Because of the
technology used (active matrix) an LCD monitor provides a totally flicker-free picture even with a
refresh rate of 60 Hz.
operating modes listed above. Depending on the screen controller used, it may be
necessary to adjust the display position and size. In this case, you can change and save
the settings (see the "Operation of the monitor" chapter).
Horizontal frequency Refresh rate Display resolution