ENERGY STAR® Power and Performance Data Sheet
1 x 3.5 SATA HDD, 250GB, 7200 RPM
PRIMERGY TX300 S5; LKN:T3005S0002IN
System Characteristics
Form Factor
Available Processor Sock ets
Available DIMM Slots / Max Memory Capacity
ECC and/or Fully Buffered DIMMs
Available Expansion Slots
Minimum and Maximum # of Hard Drives
Redundant Power Supply Capable?
Power Supply Make and Model Delta Electronics, DPS-800G B - 2 A
Power Supply Output Rating* (watts)
Minimum and Maximum # of Power Supplies
Input Power Range (AC or DC)
Power Supply Efficiency at Specified Loadings*
Power Supply Power Factor at Specified Loadings *
Operating Systems Supported
Pedestal
2
18 / 144GB
ECC and registered DIMMs
7 PCIe
0 and 6 (optional 8)
Yes
800W
1 and 2
100 - 240V AC
77.7%@10%, 87.0%@20%, 90.2%@50%, 88.8%@100%
0.850@10%, 0.930@20%, 0.970@50%, 0.990@100%
Microsoft® Windows Server® 2008
Microsoft® Windows Server® 2003
Novell SUSE Linux Enterprise Server
Red Hat Enterprise Linux
VMware Infrastructure
VMware vSphere 4.0
Installed Operating System for Testing
* Note: Power supply inform a t ion is f or a single power supply only
MS Windows Serv er 2008 E nterprise Edition; SP2
System Configurations
Processor Information
Memory Information
I/O Device s
Power Supply Number and Redundancy Configuration
Management Controller or Service Processor Installed?
Other Hardware Features / A c c es s ories
2 x Intel® Xeon® X5550 (4 cores, 2.66GHz)
12GB (6 x 2GB), PC3-10600R DDR3-1333 reg E CC
"
1 x Intel® 82575EB Dual Port Gigabit Server Adapter
2 installed, (1 redundant)
Yes
8 port SAS RAID Controller with LSI 1068 in PCIe slot
DVD-RW supermulti
Power Data
Idle Category (1S and 2S only)
ENERGY STAR Idle Power Allowanc e ( 1S and 2S only)
Measured Idle Power (watts)
Power at Full Load* (watts)
Benchmark / Method Used for Full Load Test
Test Voltage and Frequency for Idle and Full Load Test
Range of Total Estimated Energy Usage ** (k Wh/year)
Link to Detailed Power Calculator (if available)
* Note: Full load power represents the sustained, average power at 100% load of the given workload, and does not necessarily represent the absolute peak power or the
highest average, sustained power possible for other workloads.
** Note: Estimated kWh/year gives the absolute range of energy use a user could expect from continuous operation (24x365) and ranges from 100% Idle usage to 100% full
load operation. The calculation also includes typical data center overhead at a ratio of 1 watt of overhead to every 1 watt of IT load (corresponding to a P UE of 2 .0). Closer
approximations may be found by using established power calculators a nd s pe c if ic inf ormation about the intended operating environment (e. g., average time at Idle, data
Category D: Managed Dual Installed Processor (2P) Servers
186W
161,3
302,2
SiSoftware Sandra Engineer 2009.SP3c, .Net Multimedia, Double x1
230V / 50Hz
2826 to 5295
http://ts.fujitsu.com/products/standard_servers/e_efficient.html