Available Processor Sockets
Available DIMM Slots / Max Memory Capacity
ECC and/or Fully Buffered DIMMs
Available Expansion Slots
Minimum and Maximum # of Hard Drives
Redundant Power Supply Capable?
Power Supply Make and Model Delta, DPS-400AB-10 A
Power Supply Output Rating* (watts)
Minimum and Maximum # of Power Supplies
Input Power Range (AC or DC)
Power Supply Efficiency at Specified Loadings*
Power Supply Power Factor at Specified Loadings*
Operating Systems Supported
Installed Operating System for Testing
2x Intel® Xeon® E5620
4 cores, 2.40GHz
2x Intel® Xeon® E5630
4 cores, 2.53GHz
2x Intel® Xeon® E5640
4 cores, 2.66GHz
Memory Information
4GB (2x 2GB)
DDR3
12GB (6x 2GB)
DDR3
24GB (12x 2GB)
DDR3
1x Dual Port 1Gbit
Ethernet LAN
Intel® 82575EB
2 active ports
1x Dual Port 1Gbit
Ethernet LAN
Intel® 82575EB
2 active ports
1x 1Gbit Dual Port
Ethernet LAN
Intel® 82575EB
2 active ports
1x 1Gbit Quad Port
Ethernet LAN
Intel® Pro/1000PT
4 active ports
1x 4Gbit Dual Port
Fibre Channel
Emulex Lpe 11002
2 active ports
Power Supply Number and Redundancy Configuration 1 2 (1 redundancy) 2 (1 redundancy)
Management Controller or Service Processor Installed? Yes Yes Yes
Other Hardware Features / Accessories DVD RW
4 port SAS Raid
Controller
DVD RW
8 port SAS Raid
Controller
PRIMERGY RX200 S6 E-StarFam1 (2x Quad-Core CPUs)
ENERGY STAR® Power and Performance Data Sheet
80.8%@10%, 91.4%@20%, 93.0%@50%, 91.7%@100%
0.891@10%, 0.945@20%, 0.983@50%, 0.994@100%
ECC / no fully buffered DIMMs
Microsoft® Windows Server® 2008
Microsoft® Windows Server® 2008 R2
Microsoft® Windows Server® 2003
Novell SUSE Linux Enterprise Server 10 and 11 (incl. XEN)
Red Hat Enterprise Linux 5 (incl. XEN)
Microsoft Hyper-V Server 2008
MS Windows Server 2008 R2 Enterprise Edition, Version 6.1 (Build 7600)
* Note: Power supply information is for a single power supply only
Idle Category (1S and 2S only)
ENERGY STAR Idle Power Allowance (1S and 2S only) 150W 194W 282W
Measured Idle Power (watts) 93,6 122,0 172,0
Power at Full Load* (watts) 180,8 211,5 300,0
Benchmark / Method Used for Full Load Test
Test Voltage and Frequency for Idle and Full Load Test
Range of Total Estimated Energy Usage ** (kWh/year) 1640 to 3168 2137 to 3705 3013 to 5256
Link to Detailed Power Calculator (if available)
Benchmark Used and Type of Workload
Avg. Power Measured During Benchmark Run 180,8W 211,5W 300,0W
Benchmark Performance Score 37,56MPixel/s 41,8MPixel/s 41,8MPixel/s
Power Performance Ratio (perf score/avg. power) 0,21MPixels/s / W 0,20MPixels/s / W 0,14MPixels/s / W
Link to Full Benchmark Report (Where Available) N/A N/A N/A
End-User Enabling
Required
Input Power Available & Accuracy?
Input Air Temp Available & Accuracy?
Processor Utilization Available?
Other Data Measurements Available & Accuracy?
Compatible Protocols for Data Collection
Averaging method and time period
Total Power Dissipation (watts) 118 220 312
Delta Temperature at Exhaust at Peak Temp. (˚C) 7 12 20
Airflow at Maximum Fan Speed (CFM) at Peak Temp.
120m3/h 118m3/h 97m3/h
Airflow at Nominal Fan Speed (CFM) at Nominal Temp.
53m3/h 53m3/h 42m3/h
Linear Average calculation / 5 sec.
Processor Dynamic Voltage and Frequency Scaling
Processor or Core Reduced Power States
Power and Performance for Benchmark #1
SiSoftware Sandra Engineer 2009.SP4, .Net Multimedia, Double x1
http://ts.fujitsu.com/products/standard_servers/e_efficient.html
Yes, +/-10% until 200W and +/-5% above 200W
* References: ASHRAE Extended Environmental Envelope Final August 1, 2008
Thermal Guidelines for Data Processing Environments, ASHRAE, 2004, ISBN 1-931862-43-5
Peak temperature is defined as 35 ˚C, Nominal Temperature is defined as 18 - 27 ˚C
Variable Speed Fan Control Based on Power or Thermal Readings
Liquid Cooling Capability
Power and Temperature Measurement and Reporting
Category D: Managed Dual Installed Processor (2P) Servers
SiSoftware Sandra Engineer 2009.SP4, .Net Multimedia, Double x1
* Note: Full load power represents the sustained, average power at 100% load of the given workload, and does not necessarily represent the absolute peak power or the
highest average, sustained power possible for other workloads.
** Note: Estimated kWh/year gives the absolute range of energy use a user could expect from continuous operation (24x365) and ranges from 100% Idle usage to 100%
full load operation. The calculation also includes typical data center overhead at a ratio of 1 watt of overhead to every 1 watt of IT load (corresponding to a PUE of 2.0).
Closer approximations may be found by using established power calculators and specific information about the intended operating environment (e.g., average time at
ENERGY STAR Power and Performance Data Sheet
PRIMERGY RX200 S6 E-StarFam1 (2x Quad-Core CPUs)