ENERGY STAR® Power and Performance Data Sheet
PRIMERGY RX100 S6 E-StarFam1 (Dual-Core CPUs)
System Characteristics
Form Factor
Available Processor Sockets
Available DIMM Slots / Max Memory Capacity
ECC and/or Fully Buffered DIMMs
Available Expansion Slots
Minimum and Maximum # of Hard Drives
Redundant Power Supply Capable?
Power Supply Make and Model Delta, DPS-350YB A
Power Supply Output Rating* (watts)
Minimum and Maximum # of Power Supplies
Input Power Range (AC or DC)
Power Supply Efficiency at Specified Loadings*
Power Supply Power Factor at Specified Loadings *
Operating Systems Supported
Installed Operating System for Testing
* Note: Power supply information is for a single pow e r supply only
1) Note: available March, 2010
nfiguration
Configuration ID
Processor Information
Memory Information
Internal Storage
I/O Devices
Power Supply Number and Redundancy Configuration 1 1 1
Management Controller or Service Process or Ins talled? Yes Yes Yes
Other Hardware Features / A c c essories
1U Rackmount
1
4 / 16 GB
ECC / no fully buffered DIMMs
3 PCIe
0 to 4
No
350W
1
100-240V AC
79.4%@10%, 87.3%@20%, 90.4%@50%, 89.1@100%
0.74@10%, 0.88@20%, 0.97@50%, 0.99@100%
Microsoft® W indows S er ver® 2008
Microsoft® W indows S er ver® 2003
Novell SUSE Linux Enterprise Server 10
Red Hat Enterprise Linux 5
Microsoft Hyper-V Server 2008
MS Windows Serv er 2008 R2 Enterprise Edition, Version 6. 1 ( B uild 7600)
1x Intel® Core™ i3-540
2 cores, 3.06GHz
2GB (1x 2GB)
DDR3
1x 2.5" SAS HDD
146GB 15000RPM
1x 1Gbit Ethernet LAN
Intel® 82574L
1 active port
and
1x 1Gbit Ethernet LAN
Intel® 82578DM
1 active port
8 port SAS RAID
Controller
DVD-RW supermulti
1)
(incl. XEN)
1x Intel® Core™ i3-540
2 cores, 3.06GHz
2x 2.5" SAS HDD
2x 146GB 15000RPM
1x 1Gbit Ethernet LAN
1x 1Gbit Ethernet LAN
Intel® 82578DM
8 port SAS RAID
DVD-RW supermult
1)
and 11 (incl. XEN)
4GB (2x 2GB)
DDR3
Intel® 82574L
1 active port
and
1 active port
Controller
1x Intel® Core™ i3-540
2 cores, 3.06GHz
8GB (4x 2GB)
DDR3
4x 2.5" SAS HDD
4x 146GB 15000RPM
1x 1Gbit Ethernet LAN
Intel® 82574L
1 active port
and
1x 1Gbit Ethernet LAN
Intel® 82578DM
1 active port
and
2x 1Gbit Dual Port
Ethernet LAN
Intel® Pro/1000PT
4 active ports
8 port SAS RAID
Controller with iBBU
DVD-RW supermulti
ENERGY STAR Power and Performance Data Sheet
PRIMERGY RX100 S6 E-StarFam1 (Dual-Core CPUs)
Page 2 of 2
Power Data
Idle Category (1S and 2S only)
ENERGY STAR Idle Power Allowanc e ( 1S and 2S only) 55W 63W 95W
Measured Idle Power (watts) 51,1 56,1 71,5
Power at Full Load* (watts) 76,6 82,9 100,2
Benchmark / Method Used for Full Load Test
Test Voltage and Frequency for Idle and Full Load Test
Range of Total Estimated Energy Usage ** (kWh/year) 895 to 1342 983 to 1452 1253 to 1756
Link to Detailed Power Calculator (if available)
* Note: Full load power represents the sustained, average power at 100% load of the given workload, and does not necessarily represent the absolute peak power or the
highest average, sustained power possible for other workloads.
** Note: Estimated kWh/year gives the absolute range of energy use a user could expect from continuous operation (24x365) and ranges from 100% Idle usage to 100% full
load operation. The calculation also includes typical data center overhead at a ratio of 1 watt of overhead to every 1 watt of IT load (corresponding to a PUE of 2 .0). Closer
approximations may be found by using established power calculator s a nd s pe c if ic inf ormation about the intended operating environment (e .g., average time at Idle, data
Power and Performance for Benchmark #1
Benchmark Used and Type of Workload
Avg. Power Measured During Benchmark Run 76,6W 82,9W 100,2W
Benchmark Performance Score 11,9MPixels/s 12MPixels/s 12MPixels/s
Power Performance Ratio
Link to Full Benchmark Report ( Where Available) N/A N/A N/A
Benchmark #1
Processor Dynamic Voltage and Frequency Scaling
Processor or Core Reduced Power Stat es
Power Capping
Variable Speed Fan Control Based on Power or Thermal Readings
Low Power Memory States
Low Power I/O States
Liquid Cooling Capability
(perf score/avg. power)
Minimum Typical Maximum
Category A: Standard Single Installed Proc es s or (1P) Servers
SiSoftware Sandra Engineer 2009.SP3c , .Net Multimedia, Double x1
230V / 50Hz
http://ts.fujitsu.com/products/standard_servers/e_efficient.html
Minimum Typical Maximum
SiSoftware Sandra Engineer 2009.SP3c , .Net Multimedia, Double x1
0,16MPixels/s / W 0,14MPixels/s / W 0,12MPixels/s / W
Enabled on
End-User Enabling
x
x
x
Power and Temperature Measurement and Reporting
Input Power Available & Accuracy?
Input Air Temp Available & Accuracy?
Processor Utilization Available?
Other Data Measurements Available & Ac c uracy?
Compatible Protocols for Data Collection
Averaging method and time period
Thermal Information *
Total Power Dissipation (wat ts) 82 91 104
Delta Temperature at Exhaust at Peak Temp. (˚C) 13 16 19
Airflow at Maximum Fan Speed (CFM) at Peak Temp.
Airflow at Nominal Fan Speed (CFM) at Nominal Temp.
* References: ASHRAE Extended Environmental Envelope Final August 1, 2008
Thermal Guidelines for Data Processing Environments , ASHRAE, 2004, ISBN 1-931862-43-5
Peak temperature is defined as 35 ˚C, Nominal Temperature is defined as 18 - 27 ˚C
N/A (no managed server)
N/A (no managed server)
N/A (no managed server)
Minimum Typical Maximum
3
75m
/h 75m3/h 75m3/h
18m3/h 18m3/h 18m3/h