Fujitsu S26361-F4542-L75 Service Manual

Data Sheet FUJITSU Uninterruptible Power Supply (UPS) line interactive Power Protection
Data Sheet
FUJITSU Uninterruptible Power Supply (UPS) line interactive Power Protection
Advanced line interactive power protection for servers and network equipment.
Fujitsu Technology Solutions UPS devices ensure high-performance power supply protection for systems and data, and thus provide reliable protection against power failure, current
uctuations and electrical interference. Fujitsu
Technology Solutions offers both line interactive (VI) and online (VFI) devices with double conversion technology in line with the UPS
classication according to IEC 62040-3. Capacities of up to 10kVA provide the right power supply and
technology for all individual requirements. The use of uninterruptible power supplies can
particularly benet your company from a nancial
viewpoint: Having to search for and restore lost or damaged data after a power failure can cost a great deal of time and money. In such incidents UPS helps to protect your data.
Uninterruptible Power Supply (UPS) line interactive
Fujitsu Technology Solutions Line Interactive VI (Voltage Independent) UPS-devices from APC have accurate voltage regulation and offer a sinusoidal waveform. They also have a SmartSlot interface for the integration into SNMP-based network management. Another outstanding feature is the ability to replace used or faulty batteries during ongoing operation without any interruption. These APC UPSs are available as pure rack or tower devices, and as a convertible rack / tower. Fujitsu Technology Solutions not only offers customers a 3-year manufacturer’s warranty (parts warranty) on the UPS and the batteries but also
optimal integration of the control software into the network management solution ServerView Suite. Support of the Windows / Linux and SOLARIS operating systems and virtualization layers is provided. In contrast to VFI (Voltage and Frequency Independent) online UPSs, the output frequency for the VI UPSs depends on the appropriate input value; output voltage is in contrast to the
VFD (Voltage and Frequency Dependent) ofine
versions constant. A VFD UPS only protects against power failure. With the VI-UPS the DC/AC inverter is permanently connected to the output of the UPS system. During regular operations the charging current
for the battery ows via the inverter. If the AC
voltage fails, the battery takes on the supply of any connected consumers. Due to the constant connection of the inverter to the output the line­interactive technology, on which the VI class is
based, is able to lter out any mains power faults.
Main Features Benefits
Investment protection Damage to sensitive computer electronics and the destruction of
important data are prevented
Use of management software, such as APC PowerChute Business
Edition (only via a serial or USB port), APC PowerChute Network Shutdown and ServerView Suite
Page 1 / 3 www.fujitsu.com/global/products/computing/servers/primergy/racks/
Simple handling and control of the UPSs
Data Sheet FUJITSU Uninterruptible Power Supply (UPS) line interactive Power Protection
Technical details
Technical details
UPS Rack/Tower 1500VA UPS Rack/Tower 3000VA UPS Tower 1500VA UPS Tower 750VA
Input voltage 230V - 240V 1-phase Input frequency 50Hz / 60Hz Output voltage 230 V UPS Slots 1 smart card slot Input connections IEC320 C14 to IEC320 C13
power cord
UPS Notes APC PCNS Management SW, cable and manuals, SNMP
WEB management card (AP9631), Including Rack mount
kit, Including Feets for Tower usage
Interfaces 1x serial port plus cable
Output connections (8) IEC320 C13 (8) IEC320 C13 / (1) IEC320
Output connection notes 3 switched outlet groups 2 groups, 1 switched 1 group non-switched Input protection 16A 1-phase UPS Battery Pack External Runtime Extensions not for Line Interactive UPS Battery runtime half load 14 min 24 min 16 min Battery runtime full load 5 min 7 min 5 min Weight 24.8 kg 37.3 kg 24.1 kg 13.2 kg
IEC320 C20 to IEC309 (CEE
blue) power cord
1x USB port plus cable
C19
IEC320C14 no power cord, country-specic power cords
need to be ordered separately
APC PCBE Management SW,
cable and manuals
(8) IEC320 C13 (6) IEC320 C13
APC PCBE Management SW,
cable and manuals, not to
be used for TX200 or TX150
as PSU exceeds power limits
Operating system
Certied or supported operating
systems and virtualization software
Software Support PowerChute Network Shutdown 3.1 PowerChute Business Edition 9.0
Microsoft® Windows Server® 2012 R2 Microsoft® Windows Server® 2008 R2
Microsoft® Windows Server® 2008 R2 (containing
Hyper-V)
SUSE Linux Enterprise Server
Red Hat Enterprise Linux
VMware Infrastructure
Microsoft® Windows Server® 2012 R2 Microsoft® Windows Server® 2008 R2
SUSE Linux Enterprise Server
Red Hat Enterprise Linux
Order code Product Name Apparent power Active Power Dimensions mm (W x D x H)
S26361-F4542-L150 PY LI UPS 1500VA Tower 1500 VA 1000 W 171 x 439 x 219 S26361-F4542-L75 PY LI UPS 750VA Tower 750 VA 500 W 138 x 363 x 161 S26361-K1426-V150 PY LI UPS 1500VA R/T 1500 VA 1200 W 432 x 490 x 89 S26361-K1426-V300 PY LI UPS 3000VA R/T 3000 VA 2700 W 432 x 667 x 89
Approvals & Conformity (Standards)
Europe CE
EN
Global CB Compliance link http://globalsp.ts.fujitsu.com/sites/certicates
Warranty
Warranty period 3 years (depending on country) Warranty type Door-to-Door Exchange Service
Product Support Services - the perfect extension
Recommended Service 1/3 years Warranty extension Service Weblink http://www.fujitsu.com/fts/services/support
Page 2 / 3 www.fujitsu.com/global/products/computing/servers/primergy/racks/