This manual contains important information for using this product. Read thoroughly before using
the product. Use this product only after thoroughly reading and understanding especially the
section “Important Alert Items” in this manual. Keep this manual handy, and keep it carefully.
FUJITSU makes every effort to prevent users and bystanders from being injured or from suffering
damage to their property. Use the product according to this manual.
IMPORTANT NOTE TO USERS
READ THE ENTIRE MANUAL CAREFULLY BEFORE USING THIS PRODUCT.
INCORRECT USE OF THE PRODUCT MAY RESULT IN INJURY OR DAMAGE TO
USERS, BYSTANDERS OR PROPERTY.
While FUJITSU has sought to ensure the accuracy of all information in this manual, FUJITSU
assumes no liability to any party for any damage caused by any error or omission contained in this
manual, its updates or supplements, whether such errors or omissions result from negligence,
accident, or any other cause. In addition, FUJITSU assumes no liability with respect to the
application or use of any product or system in accordance with the descriptions or instructions
contained herein; including any liability for incidental or consequential damages arising therefrom.
FUJITSU DISCLAIMS ALL WARRANTIES REGARDING THE INFORMATION
CONTAINED HEREIN, WHETHER EXPRESSED, IMPLIED, OR STATUTORY.
FUJITSU reserves the right to make changes to any products described herein without further
notice and without obligation.
This product is designed and manufactured for use in standard applications such as office work,
personal devices and household appliances. This product is not intended for special uses (atomic
controls, aeronautic or space systems, mass transport controls, medical devices for life support, or
weapons firing controls) where particularly high reliability requirements exist, where the pertinent
levels of safety are not guaranteed, or where a failure or operational error could threaten a life or
cause a physical injury (hereafter referred to as "mission-critical" use). Customers considering the
use of these products for mission-critical applications must have safety-assurance measures in
place beforehand. Moreover, they are requested to consult our sales representative before
embarking on such specialized use.
The contents of this manual may be revised without prior notice.
The contents of this manual shall not be disclosed in any way or reproduced in any media without
the express written permission of Fujitsu Limited.
All Rights Reserved, Copyright FUJITSU LIMITED 2005
Revision History
(1/1)
Edition Date Revised section (*1)
(Added/Deleted/Altered)
01 2005-05-16 — —
Details
*1 Section(s) with asterisk (*) refer to the previous edition when those were deleted.
C141-F074
This page is intentionally left blank.
Preface
This manual describes the MHV2100BH, MHV2080BH, MHV2060BH, MHV2040BH 2.5-inch hard
disk drives with a built-in controller that is compatible with the Serial-ATA interface.
This manual explains, in detail, how to maintain the disk drives.
This manual assumes that users have a basic knowledge of hard disk drives and their application in
computer systems.
This manual consists of the following two chapters:
Overview of Manual
CHAPTER 1 Maintenance and Diagnosis
This chapter explains MHV2100BH, MHV2080BH, MHV2060BH, MHV2040BH
maintenance requirements, operation verification, and troubleshooting.
CHAPTER 2 Removal and Replacement Procedure
This chapter explains the procedure for removing and replacing MHV2100BH,
MHV2080BH, MHV2060BH, MHV2040BH.
Abbreviations
This section lists the abbreviated terms and their full words used in this manual.
Index
In this manual, disk drives may be referred to as drives, or devices.
IBM PC-AT is a registered trademark of IBM (International Business Machines
Corporation) of the United States of America.
Conventions for Alert Messages
This manual uses the following conventions to show the alert messages. An alert
message consists of an alert signal and alert statements. The alert signal consists
of an alert symbol and a signal word or just a signal word.
The following are the alert signals and their meanings:
This indicates a hazardous situation could result in
minor or moderate personal injury if the user does
not perform the procedure correctly. This alert
signal also indicates that damages to the product or
other property may occur if the user does not perform
the procedure correctly.
This indicates information that could help the user
use the product more efficiently.
C141-F074 i
Preface
In the text, the alert signal is centered, followed below by the indented message.
A wider line space precedes and follows the alert message to show where the alert
message begins and ends. The following is an example:
(Example)
Don’t install or remove a PCA or connect or disconnect a cable or
connector plug when the drive is powered. This may give you an
electric shock.
The main alert messages in the text are also listed in the “Important Alert Items.”
Operating Environment
This product is designed to be used in offices or computer rooms.
For details regarding the operating environment of use, refer to the Product
Manual (C141-E224).
Hot Plug
Attention
These drives support Hot Plug which is based on Serial ATA II Extension to
Serial ATA 1.0a Specification.
However, the disk drive installation and removal notes on safety precautions with
regard to hot-plugging vary depending on the specific requirements and
environment-related conditions of the system to which the drive is connected by
hot-plugging.
When using the drive under general conditions of use (i.e., without hotplugging),
observe the important alert messages and notes on safety precautions given in this
manual.
For the electrical recommendation to the host system which supports hot-plugging
with this drives, refer to Section 5.1.6 of the MHV2100BH, MHV2080BH, MHV2060BH, MHV2040BH Disk Drives Product Manual.
Please forward any comments you may have regarding this manual.
To make this manual easier for users to understand, opinions from readers are
needed. Please write your opinions or requests on the Comment at the back of
this manual and forward it to the address described in the sheet.
ii C141-F074
Preface
Liability Exception
“Disk drive defects” refers to defects that involve adjustment, repair, or
replacement.
Fujitsu is not liable for any other disk drive defects, such as those caused by user
misoperation or mishandling, inappropriate operating environments, defects in the
power supply or cable, problems of the host system, or other causes outside the
disk drive.
C141-F074 iii
This page is intentionally left blank.
Important Alert Items
Important Alert Messages
The important alert messages in this manual are as follows:
This manual uses the key alert messages given below.
The following manual also contains notes on safety precautions:
A hazardous situation could result in minor or moderate personal injury if the user does not perform the procedure correctly. Also,
damage to the predate or other property, may occur if the user does
not perform the procedure correctly.
Task Alert message Page
Maintenance
Static, Damage
1. Don’t install or remove a PCA or connect or disconnect
a cable or connector plug when the drive is powered.
This may give you an electric shock.
2. Keep away from mechanical assemblies in the unit
during operation. This may cause injuries.
3. Avoid dangerous detergent when the disk drive is
cleaned.
1-2
C141-F074 v
Important Alert Items
Task Alert message Page
Maintenance
Device damage
1. Before touching a PCA or the drive, wear a wrist strap
and perform the human body grounding to discharge
static electricity from your body. This will prevent
irreparable damage to the PCA and the head of the drive.
2. Don’t install or remove a PCA or connect or disconnect
a cable or connector plug when the drive is powered.
This will prevent electrical damage to the disk drive.
3. Operating the disk drive with one or more PCA missing
will be unpredictable. Only power the drive with all
boards installed.
4. Avoid any detergent which may cause short circuits
when cleaning assemblies.
5. Keep all vents open opened and unblocked. Avoid other
conditions which may cause circuits to overheat.
6. Do not apply excessive force to the cover under any
circumstances. Doing so may cause irreparable damage
to the cover.
Device damage
1-2
The DE is completely sealed. Do not open the DE in the
1-3
field.
Data corruption
When asking for repair, save all data stored in the disk drive
1-4
beforehand. Fujitsu Limited is not responsible for any loss
of data during service and repair.
Device damage
The disk enclosure (DE) must never to be opened in the
1-14
field. Opening the disk enclosure may cause irreparable
damage.
vi C141-F074
Important Alert Items
Task Alert message Page
Maintenance
Damage or Device damage
1. Perform any removal after the system power is
completely disconnected. The cable must not be
disconnected and the screws that attach the drive must
not be removed with the power ON.
2. Do not move the drive and attach or detach the
connector until it comes to a complete stop (about 30 s
after the power is turned OFF).
3. Perform the human body grounding to discharge any
static electricity from your body. (Be sure to wear a
wrist strap)
2-2
C141-F074 vii
This page is intentionally left blank.
Manual Organization
MHV2100BH, MHV2080BH
MHV2060BH, MHV2040BH
DISK DRIVES
PRODUCT MANUAL
(C141-E224)
MHV2100BH, MHV2080BH
MHV2060BH, MHV2040BH
DISK DRIVES
MAINTENANCE MANUAL
<This manual>
1. Device Overview
2. Device Configuration
3. Installation Conditions
4. Theory of Device Operation
5. Interface
6. Operations
1. Maintenance and Diagnosis
2. Removal and Replacement Procedure
C141-F074 ix
This page is intentionally left blank.
Contents
CHAPTER 1 Maintenance and Diagnosis.....................................................1-1
1.3.2 Troubleshooting disk drive replaced in field....................................... 1-12
1.3.3 Troubleshooting at factory................................................................... 1-14
CHAPTER 2 Removal and Replacement Procedure ...................................2-1
2.1 Spare Parts ............................................................................................. 2-2
2.2 Disk Drive Removal .............................................................................. 2-2
C141-F074 xi
Contents
Figures
Tables
Illustrations
Figure 1.1 Disk drive revision number label................................................1-6
Figure 1.2 Display of disk drive revision number .......................................1-7
Figure 1.3 Test flowchart.............................................................................1-9
Table 1.1 Status Field contents.................................................................1-10
Table 1.2 Disposition for Error Field contents .........................................1-10
Table 1.3 System level and field troubleshooting ....................................1-13
Table 2.1 Model and parts numbers............................................................2-2
xii C141-F074
CHAPTER 1 Maintenance and Diagnosis
1.1 Maintenance
1.2 Operation Confirmation
1.3 Troubleshooting Procedure
This chapter describes the maintenance, diagnosis, operation check, and
troubleshooting of the disk drive. The following are explained:
• Rules for regular maintenance and troubleshooting
• Display of maintenance level (field and factory)
• Display of machine revision number and number change in the field
• Tools and test devices needed for each maintenance level
• Standard testing for each maintenance level
• Recommended procedure for troubleshooting and fault diagnosis
C141-F074 1-1
Maintenance and Diagnosis
1.1 Maintenance
1.1.1 Rules for maintenance
The following cautions must be observed to prevent injury during troubleshooting
or maintenance.
Static, Damage
1. Don’t install or remove a PCA or connect or disconnect a cable
or connector plug when the drive is powered. This may give
you an electric shock.
2. Keep away from mechanical assemblies in the unit during
operation. This may cause injuries.
3. Avoid dangerous detergent when the disk drive is cleaned.
The following cautions must be observed to avoid damaging the disk drive during
troubleshooting and maintenance.
Device damage
1. Before touching a PCA or the drive, wear a wrist strap and
perform the human body grounding to discharge static
electricity from your body. This will prevent irreparable
damage to the PCA and the head of the drive.
2. Don’t install or remove a PCA or connect or disconnect a cable
or connector plug when the drive is powered. This will prevent
electrical damage to the disk drive.
3. Operating the disk drive with one or more PCA missing will be
unpredictable. Only power the drive with all boards installed.
4. Avoid any detergent which may cause short circuits when
cleaning assemblies.
5. Keep all vents open opened and unblocked. Avoid other
conditions which may cause circuits to overheat.
6. Do not apply excessive force to the cover under any
circumstances. Doing so may cause irreparable damage to the
cover.
1-2 C141-F074
1.1 Maintenance
1.1.2 Maintenance requirements
(1) Preventive maintenance
The disk drive needs no preventive maintenance, not even the air filter needs to be
changed.
Device damage
The DE is completely sealed. Do not open the DE in the field.
(2) Service life
In situations where management and handling are correct, the life of the disk drive
is five years when the DE surface temperature is less than 48°C. When the DE
surface temperature exceeds 48°C, the life is five years or 20,000 hours of
operation, whichever occurs first. Refer to Section 1.7 and 3.2 in Product Manual.
(3) Exchangeable parts in field
The PCA and the DE cannot be replaced separately in the field. Replace the
whole disk drive.
(4) Service system and repair
Fujitsu Limited has a disk drive service system and repair facility. When making
a request for repair or parts replacement, you should provide related information
usually including:
a) Model name of disk drive, part number (P/N), disk drive revision number,
manufacture serial number (S/N), and date of manufacture of the disk drive
b) Circumstances when the fault occurred
− Date of trouble occurred
− System configuration
− Environmental conditions (including temperature, humidity, and voltage)
c) Fault history of the drive
d) Details of the fault
− Description of the fault
− Issued command and specified parameters
− Status (Status/Error register)
− Interval of the fault
− Other information for fault diagnosis
C141-F074 1-3
Maintenance and Diagnosis
Data corruption
When asking for repair, save all data stored in the disk drive
beforehand. Fujitsu Limited is not responsible for any loss of data
during service and repair.
(5) Notes on handling
a. General notes
a) Vibrations and shocks more severe than allowed will cause fatal damage to
the device so be very careful. Be especially careful when unpacking the
device.
b) Do not leave the device in a dusty environment.
c) Because the device uses MR (MR head) and static sensitive CMOS
semiconductors take the following precautions, be careful of the handling on
the following points after the device is unpacked.
b. Unpacking
a) Use a flat workplace, find which side of the pack is up and be careful not to
b) Be careful not to apply any excessive force to the packed device when
c) When taking the device out of the antistatic bag, be especially careful not to
d) Never ever remove the DE seal label and screws and the DE cover.
c. Installation
a) When the power is ON, do not change the switch setting, or connecting, or
− Use an antistatic mat, etc. in the environment for handling the
equipment. The worker should also be physically grounded (e.g.,
wearing a wrist strap).
− Hold by the DE section, do not directly touch the PCA unit
unnecessarily.
have the wrong side facing upwards. Do not place the device directly on a
hard table, place it on something soft such as a rubber mat.
removing the shock absorbing material.
apply any excessive force to the PCA or to the interface connector section.
disconnecting connectors.
b) Do not move the device or disconnect connectors with the power ON or until
the disk drive unit comes to a complete stop after the power is turned OFF.
(It is required to wait more than 30 seconds.)
d. Packaging
a) Place the device in an antistatic vinyl bag along with a desiccant (silica gel).
1-4 C141-F074
1.1 Maintenance
b) It is recommended that you use the shock absorption cushion material and
packaging that contained the device when it was delivered by Fujitsu.
If the same packaging material cannot be used, use a shock absorbent box
that will transmit shocks directly to the device. When using this type of box,
adequately protect the PCA surface and interface connector section.
c) Place a label showing which side is up and clearly stating the notes on
handling on the outside of the packaging.
e. Delivery
a) As a rule, deliver as it is packaged and keep the up side up.
b) If delivering a single drive after it is unpacked, take it only a short distance.
Also, use shock absorbent material to protect it against shock and vibration.
Deliver an unpacked device in either of the allowable packed positions.
Refer to Section 3.2 of the MHV2100BH, MHV2080BH, MHV2060BH, MHV2040BH Disk Drives Product Manual.
f. Storage
a) Store in dampproof packaging.
b) Take care that the environmental requirements satisfy the non-operating
environmental specifications described in Section 1.4 of the MHV2100BH, MHV2080BH, MHV2060BH, MHV2040BH Disk Drives Product Manual.
c) To prevent condensation, do not subject the device to sudden changes of
temperature.
1.1.3 Maintenance levels
Because of its compact size and special repair requirements, it is recommended
that the whole disk drive be replaced. This section describes maintenance on two
levels.
(1) Field maintenance (disk drive replacement)
• Replacement at the user site.
• Disk drive replacement requires ordinary tools.
• Usually, the user, retailer, seller, or OEM trader will replace the drive.
(2) Factory maintenance (parts replacement)
• Only Fujitsu can perform maintenance at this level.
• This includes maintenance training and assisting other OEM traders. The
OEM trader usually assists the retailer and seller.
• Use the factory level tools and test equipment. This includes recommended
spare parts and repairing or replacing various parts.
C141-F074 1-5
Maintenance and Diagnosis
1.1.4 Disk drive revision number
The disk drive revision number is a single alphabetic character followed by a
single alphanumeric character. It is stuck on the DE and marked on the revision
number label. Figure 1.1 shows the disk drive revision number label format.
Disk drive revision number
Firmware code/revision
Figure 1.1 Disk drive revision number label
1-6 C141-F074
1.1 Maintenance
(1) Revision number marking at delivery
The machine revision number is indicated by crossing out up to the relevant
number in the relevant alphabetic character row using = marks (see Figure 1.2).
(2) Revision number change in the field
When a part is replaced in the field or other modifications are made, the machine
revision number may need to be changed. The level is indicated by crossing out
the relevant number in the relevant alphabetic character row using { marks (see
Figure 1.2).
(3) Firmware code and revision
First 4-digit indicates a firmware code and rest 4-digit indicates its revision.
Note:
For a change of revision number after delivery, Fujitsu issues a
“Change Request/Notice” and the disk drive revision number after
the change. When a change is made at the user site, the revision
number level should be changed as described above.
Revision number mark when delivered
A2 Revision
Revision number change in the field
A3 Revision
Figure 1.2 Display of disk drive revision number
C141-F074 1-7
Maintenance and Diagnosis
1.1.5 Tools and test equipment
At the field maintenance level, only ordinary hand tools are required for
troubleshooting and repairing the disk drive. Special tools and test equipment is
not required.
Factory level tools and test equipment are beyond the scope of this manual.
1.1.6 Self-diagnostics
The disk drive has the following self-diagnostics. These self-diagnostics allow
normal basic operation of an isolated disk drive can be checked.
The disk drive test can be divided into the following three levels.
• Operating test (See Subsection 1.2.1, “Operating test.”)
• Diagnostic test (See Subsection 1.2.2, “Diagnostic test.”)
Figure 1.3 shows the relationship between the test level and troubleshooting.
Tables 1.1 and 1.2 show the check contents.
1-8 C141-F074
1.1 Maintenance
Start
Yes
Check the host system
(Table 1.1)
Operation test with the
host computer or test
equipment
Test acceptable?
Yes
Continue with the
operation
No
System normal?
Yes
Disk drive
replacement or repair
Disk drive normal?
Yes
Diagnostic test with
the host computer or
test equipment
Test acceptable?
Yes
Test using voltage or
temperature stress
No
No
No
Analyze the system
related failure
Test acceptable?
Yes
No failure
NoDisk drive failure
analysis (Table 1.2)
Figure 1.3 Test flowchart
C141-F074 1-9
Maintenance and Diagnosis
Table 1.1 Status Field contents
bit Contents
BIT0=1 Shown in Table 1.2
BIT1, 2 It is not necessary to take any measure when other bits are
normal, in spite of these bits. (Normal)
BIT3=1
BIT4=1
BIT5=1
BIT6=0
Any of these
cases.
BIT7=1
Error bit Method of disposition
BIT0
BIT1
BIT4
Any of these
bits are “1”.
BIT6
BIT4=1 and BIT2=1
or
BIT3=1 and BIT2=1
(1) Check whether vibration is transmitted because of the way
the disk drive is mounted.
(2) Check the power, cable, and connector.
(3) If it is concluded that the disk drive is the cause, replace the
disk drive.
Table 1.2 Disposition for Error Field contents
If it is concluded that the disk drive is the cause, replace the
drive.
(1) Check the status of the host system, cable, and drive.
(2) If it is concluded that the disk drive is the cause,
replace the drive.
or
BIT2
BIT7
Any of these
bits are “1”.
1-10 C141-F074
1.2 Operation Confirmation
1.2 Operation Confirmation
1.2.1 Operation test
When the host computer is processing data, the disk drive monitors disk drive
operation errors including data, command, and seek errors. The host is notified of
the error that the disk drive detected and the user is notified of its result.
The user may notice intermittent and indefinite failures such as overlong
execution time, abnormal noise, abnormal odor, or failures in particular processes.
The failure reported in the operation test will need further investigation. To
ascertain the cause of the disk drive failure reported, the disk drive can be
replaced. Failures in the operation test are often not caused by the host system.
For example, not having enough power supply reserve, a loose cable connection,
no timing and mechanical reserves, or relationship with other systems.
In normal operation, the disk drive itself or the host determines the processing
(return or halt) following the detected failure state.
To troubleshoot the failure reported in the test at this level, accurately reproduce
the condition that caused the failure. Then, by replacing the disk drive, try to
separate the fault from the other sections of the disk drive host system.
1.2.2 Diagnostic test
The diagnostic test is used to separate a confirmed disk drive failure to a disk
drive subassembly or to check the disk drive performance. A test of this level
usually includes a specific disk drive function or concentrated execution of a
group of functions. The test is usually performed by a factory engineer and not
where the failure was reported. The disk drive is tested using another host
computer or test equipment.
To troubleshoot the disk drive failure in the diagnostic test, the engineer will
reproduce the failure condition. The engineer then isolates the failure to a
subassembly or part of the disk drive.
The procedures used in a test of this level great depend on the test equipment
used. It is beyond the range of this manual.
C141-F074 1-11
Maintenance and Diagnosis
1.3 Troubleshooting Procedure
1.3.1 Troubleshooting procedure
This section describes the troubleshooting procedures for a disk drive failure at
field maintenance level described in Subsection 1.1.3.
In this section, troubleshooting is made to isolate the reported failure to the disk drive
or a host system. Usually, troubleshooting is necessary only when a cause of failure is
uncertain or unknown. When a cause of failure is clear (for example, abnormal sound
in the DE or burnt parts on the PCA), a level of troubleshooting is low.
1.3.2 Troubleshooting disk drive replaced in field
It is recommended that the whole drive be replaced in maintenance of this level.
If replacing the drive corrects the fault, return the old drive to the factory for
testing and repair. If the new drive shows the same fault as the one that was
removed, the failure is elsewhere in the system.
System level troubleshooting, shown in Table 1.3, is performed at the user site to
isolate the reported failure to the disk drive or system.
1-12 C141-F074
1.3 Troubleshooting Procedure
Table 1.3 System level and field troubleshooting
Check to be made Recommended work
DC power voltage
level
Confirm that the DC power voltage is within ±5% of the standard value.
When measured at +5 V power pins P8 or P9 and GND pins P4-P6, P10,
or P12 of the power supply connector, the +5 DVC must be 4.75 to 5.25
VDC.
Refer to Sections 3.3 and 5.1.4 of the MHV2100BH, MHV2080BH,
DC power ripple
noise
SATA Interface
Connection
MHV2060BH,MHV2040BH Disk Drives Product Manual.
Check that the maximum ripple at +5 VDC power is less than 100 mV
peak to peak and 200 mV peak to peak respectively.
Confirm that the SATA interface at the drive is properly connected with
the host receptacle.
(Including a
Connection of
Power Segment)
System cable Confirm that all cable connections throughout the system correctly
connected.
System diagnostic
test
Intermittent or
indefinite error
To further isolate the failure, if it can be done, execute the system level
diagnostic routine described in the host computer manual.
Check the AC voltage level at the power supply section and recheck the
DC voltage level at the disk drive power supply connector.
If the AC voltage level is abnormal, or if there is a lot of electrical noise,
notify the user.
If the DC voltage level is unstable, replace the power supply section.
If possible, replace the disk drive. If the fault remains, the disk drive is
not the case. For suggestions to isolate the failure further, refer to the
hardware and software manuals provided with the system.
C141-F074 1-13
Maintenance and Diagnosis
1.3.3 Troubleshooting at factory
When the trouble is recovered by replacing the drive at field (Subsection 1.3.2),
troubleshoot the replaced drive to isolate the trouble to the subassembly parts.
To shorten the troubleshooting time and repairing time, gather the data, such as
environmental data and other information, from the user and then return the failed
drive to the factory to repair.
At the factory, user environment is made and a reappearance test is performed.
To reappearance a same trouble at user, the failed drive is connected to the host
system. If no trouble occurs by the normal test, the reappearance test is
performed by adding the voltage/temperature load using a disk drive tester or
tools according to the user environment.
When a trouble reappeared, troubleshoot the cause of failure. Then, replace the
failed unit or parts.
As this level maintenance is made by a factory, this maintenance level is beyond
the scope of this manual.
Device damage
The disk enclosure (DE) must never to be opened in the field.
Opening the disk enclosure may cause irreparable damage.
1-14 C141-F074
CHAPTER 2 Removal and Replacement Procedure
2.1 Spare Parts
2.2 Disk Drive Removal
This chapter explains the procedure for removing and replacing the disk drive. It
is assumed that the reader has a thorough knowledge of replacing the complete
disk drive and replacing the power-interface cable.
When carrying out these procedures, note the following items.
• Be sure to wear a wrist strap when removing the disk drive from the host
system.
• The disk drive must have been removed from the host system.
• A power-interface cable to the disk drive must be disconnected.
• Mounting is done by reversing the steps for removal.
To carry out maintenance properly, observe the following:
• Place removed screws and other parts where they will not get lost or
damaged.
• Keep a record of all maintenance work.
• Tighten screws securely but not excessively.
• Before touching the PCA, wear a wrist strap and check it is grounded to
discharge any static electricity from your body. This ensures that the worker
will not electrically damage the PCA.
• Do not push the DE cover under any circumstances.
C141-F074 2-1
Removal and Replacement Procedure
2.1 Spare Parts
See Table 2.1 for the model and parts numbers to order the replacement disk drive.
The method and procedures to demount the disk drive to check the jumper
terminal, change the jumper position, or replace the device differ depend on the
system cabinet structure. Therefore, for actual working procedures, the specific
conditions necessary for each system must be determined. The general removal
procedures, with notes, are as follows.
a) Disconnect the power-interface cable.
b) Remove the screws that attach the drive and remove the drive from the
system cabinet.
Mounting screw Order No.
c) When storing or transporting the drive, pack it an antistatic bag in
compliance with section 1.1.2 (5) d. and (5) e..
To protect the device from damage and prevent the worker getting hurt, observe
the following cautions and precautions in Subsection 1.1.1.
Damage or Device damage
1. Perform any removal after the system power is completely
disconnected. The cable must not be disconnected and the
screws that attach the drive must not be removed with the
power ON.
2. Do not move the drive and attach or detach the connector until
it comes to a complete stop (about 30 s after the power is
turned OFF).
3. Perform the human body grounding to discharge any static
electricity from your body. (Be sure to wear a wrist strap)
2-2 C141-F074
Acronyms and Abbreviations
A
ABRT Aborted command
AC Alternating current
AIC Automatic idle control
AMNF Address mark not found
ATA AT attachment
AWG American Wire Gauge
B
BBK Bad block detected
BIOS Basic input-output system
C
CORR Corrected data
CH Cylinder high field
CL Cylinder low field
CM Command field
CMOS Complementary
metal-oxide semiconductor
CSR Current sense field
CSS Contact start/stop
CY Cylinderfield
D
dBA dB A-scale weighting
DC Direct current
DE Disk enclosure
DH Device/head field
DRDY Drive ready
DRQ Data request bit
DSC Drive seek complete
DWF Drive write fault
E
ECC Error checking and correction
ER Error field
ERR Error
F
H
HA Host adapter
HDD Hard disk drive
I
IDNF ID not found
IRQ14 Interrupt request 14
L
LED Light emitting diode
M
MB Mega-byte
MB/s Mega-byte per seconds
MPU Micro processor unit
MTBF Mean time between failures
MTTR Mean time to repair
O
OEM Original equipment manufacture
P
PCA Printed circuit assembly
PIO Programmed input-output
P/N Parts number
R
RLL Run-length-limited
S
SA System area
SATA Serial-ATA
SC Sector count field
SG Signal ground
SN Sector number field
ST Status field
S/N Serial number
FR Features field
G
GB Giga byte
C141-F074 AB-1
TPI Tracks per inches
TR0NF Track 0 not found
Typ Typical
T
Acronyms and Abbreviations
U
UNC Uncorrectable ECC error
V
VCM Voice coil motor
AB-2 C141-F074
Index
D
Dampproof packaging 1-5
Delivery 1-5
revision number marking 1-7
Diagnostic test 1-11
Disk drive
replaced, troubleshooting 1-12
replacement 1-5
revision number 1-6
revision number label 1-6
Disposition for Error Field contents 1-10
E
Exchangable parts in field 1-3
F
Factory
maintenace 1-5
troubleshooting 1-14
Field
exchangable parts 1-3
maintenance 1-5
revision number change 1-6, 1-7
troubleshooting 1-12
Firmware code and revision 1-7
G
N
Notes
general 1-4
on handling 1-4
O
Offline self-diagnostics 1-8
Operation
configuration 1-11
test 1-10
P
Packaging 1-4
dampproof 1-5
Parts
numbers 2-2
replacement 1-5
Preventive maintenance 1-3
R
Removal and replacement procedure 2-1
Revision, firmware code 1-7
Revision number
change in the field 1-6, 1-7
mark when delivered 1-6, 1-7
Rules for maintenance 1-2
General notes 1-4
H
Handling, notes 1-4
Self-diagnostics 1-8
initial 1-8
offline 1-8
S
Service
I
Initial self-diagnostics 1-8
Installation 1-4
life 1-3
system and repair 1-3
Spare parts 2-2
Status Field contents 1-10
Storage 1-5
L
Levels, maintenance 1-5
M
Maintenance 1-1
levels 1-5
requirements 1-3
Maintenance and diagnosis 1-1
System level 1-13
and field troubleshootng 1-13
T
Test 1-8
equipment 1-8
flowchart 1-9
Tools 1-8
Model 2-2
C141-F074 IN-1
Index
Troubleshooting
at factory 1-14
disk drive replaced in field 1-12
procedure 1-12
system level and field 1-13
U
Unpacking 1-4
IN-2 C141-F074
READER’S COMMENT FORM
Your comments or suggestions on this document are cordially solicited. For any comments and suggestions you
may have, please complete and submit this form to your FUJITSU representative. The comments and
suggestions will be used in planning future editions. Thank you for your cooperation.
Date issued:
Name:
Company or organization:
Address:
Comments:
Page Line Comments
Reply requested: Yes No
Manual name:
Manual code:
MHV2100BH, MHV2080BH,
MHV2060BH, MHV2040BH
DISK DRIVES
MAINTENANCE MANUAL
C141-F074-01EN
Please evaluate overall quality of this manual by marking (√) in the appropriate boxes.
Good Fair Poor Good Fair Poor Good Fair Poor
Organization:
Accuracy:
Clarity:
Figures & tables:
Technical level: Too high
Overall rating of
this publication: Good
Use of examples: Legibility: Index coverage: Handiness/Binding: Cross referencing: (Others): General appearance:
Appropriate Too low
Fair Poor
FOR FUJITSU USE
Overseas office: Person in charge:
Note) Local representative should pass this form to the section in charge of distribution in FUJITSU.
Reply
By
This page is intentionally left blank
MHV2100BH, MHV2080BH, MHV2060BH, MHV2040BH
DISK DRIVES MAINTENANCE MANUAL
MHV2100BH, MHV2080BH, MHV2060BH, MHV2040BH
DISK DRIVES MAINTENANCE MANUAL
C141-F074-01EN
C141-F074-01EN
This page is intentionally left blank