Fujitsu MHV2040BS, MHV2060BS, MHV2080BS User Manual

C141-F075-01EN
MHV2080BS, MHV2060BS, MHV2040BS
DISK DRIVES
MAINTENANCE MANUAL

FOR SAFE OPERATION

Handling of This Manual
FUJITSU makes every effort to prevent users and bystanders from being injured or from suffering damage to their property. Use the product according to this manual.
IMPORTANT NOTE TO USERS
READ THE ENTIRE MANUAL CAREFULLY BEFORE USING THIS PRODUCT. INCORRECT USE OF THE PRODUCT MAY RESULT IN INJURY OR DAMAGE TO USERS, BYSTANDERS OR PROPERTY.
While FUJITSU has sought to ensure the accuracy of all information in this manual, FUJITSU assumes no liability to any party for any damage caused by any error or omission contained in this manual, its updates or supplements, whether such errors or omissions result from negligence, accident, or any other cause. In addition, FUJITSU assumes no liability with respect to the application or use of any product or system in accordance with the descriptions or instructions contained herein; including any liability for incidental or consequential damages arising therefrom. FUJITSU DISCLAIMS ALL WARRANTIES REGARDING THE INFORMATION CONTAINED HEREIN, WHETHER EXPRESSED, IMPLIED, OR STATUTORY.
FUJITSU reserves the right to make changes to any products described herein without further notice and without obligation.
This product is designed and manufactured for use in standard applications such as office work, personal devices and household appliances. This product is not intended for special uses (atomic controls, aeronautic or space systems, mass transport controls, medical devices for life support, or weapons firing controls) where particularly high reliability requirements exist, where the pertinent levels of safety are not guaranteed, or where a failure or operational error could threaten a life or cause a physical injury (hereafter referred to as "mission-critical" use). Customers considering the use of these products for mission-critical applications must have safety-assurance measures in place beforehand. Moreover, they are requested to consult our sales representative before embarking on such specialized use.
The contents of this manual may be revised without prior notice.
The contents of this manual shall not be disclosed in any way or reproduced in any media without the express written permission of Fujitsu Limited.
All Rights Reserved, Copyright FUJITSU LIMITED 2005

Revision History

(1/1)
Edition Date Revised section (*1)
(Added/Deleted/Altered)
01 2005-05-16
Details
*1 Section(s) with asterisk (*) refer to the previous edition when those were deleted.
C141-F075
This page is intentionally left blank.

Preface

This manual describes the MHV2080BS, MHV2060BS, MHV2040BS 2.5-inch hard disk drives with a built-in controller that is compatible with the Serial-ATA interface.
This manual explains, in detail, how to maintain the disk drives.
This manual assumes that users have a basic knowledge of hard disk drives and their application in computer systems.
This manual consists of the following two chapters:
Overview of Manual
CHAPTER 1 Maintenance and Diagnosis
This chapter explains MHV2080BS, MHV2060BS, MHV2040BS maintenance requirements, operation verification, and troubleshooting.
CHAPTER 2 Removal and Replacement Procedure
This chapter explains the procedure for removing and replacing MHV2080BS, MHV2060BS, MHV2040BS.
Abbreviations
This section lists the abbreviated terms and their full words used in this manual.
Index
In this manual, disk drives may be referred to as drives, or devices. IBM PC-AT is a registered trademark of IBM (International Business Machines
Corporation) of the United States of America.
Conventions for Alert Messages
This manual uses the following conventions to show the alert messages. An alert message consists of an alert signal and alert statements. The alert signal consists of an alert symbol and a signal word or just a signal word.
The following are the alert signals and their meanings:
This indicates a hazardous situation could result in minor or moderate personal injury if the user does not perform the procedure correctly. This alert signal also indicates that damages to the product or other property may occur if the user does not perform the procedure correctly.
This indicates information that could help the user use the product more efficiently.
C141-F075 i
Preface
In the text, the alert signal is centered, followed below by the indented message. A wider line space precedes and follows the alert message to show where the alert message begins and ends. The following is an example:
(Example)
Don’t install or remove a PCA or connect or disconnect a cable or connector plug when the drive is powered. This may give you an electric shock.
The main alert messages in the text are also listed in the “Important Alert Items.”
Operating Environment
This product is designed to be used in offices or computer rooms.
Hot Plug
Attention
For details regarding the operating environment of use, refer to the Product Manual (C141-E225).
These drives support Hot Plug which is based on Serial ATA II Extension to Serial ATA 1.0a Specification.
However, the disk drive installation and removal notes on safety precautions with regard to hot-plugging vary depending on the specific requirements and environment-related conditions of the system to which the drive is connected by hot-plugging.
When using the drive under general conditions of use (i.e., without hotplugging), observe the important alert messages and notes on safety precautions given in this manual.
For the electrical recommendation to the host system which supports hot-plugging with this drives, refer to Section 5.1.6 of the MHV2080BS, MHV2060BS, MHV2040BS Disk Drives Product Manual.
Please forward any comments you may have regarding this manual. To make this manual easier for users to understand, opinions from readers are
needed. Please write your opinions or requests on the Comment at the back of this manual and forward it to the address described in the sheet.
ii C141-F075
Liability Exception
“Disk drive defects” refers to defects that involve adjustment, repair, or replacement.
Fujitsu is not liable for any other disk drive defects, such as those caused by user misoperation or mishandling, inappropriate operating environments, defects in the power supply or cable, problems of the host system, or other causes outside the disk drive.
Preface
C141-F075 iii
This page is intentionally left blank
Important Alert Items

Important Alert Messages

The important alert messages in this manual are as follows:
This manual uses the key alert messages given below.
The following manual also contains notes on safety precautions:
A hazardous situation could result in minor or moderate personal injury if the user does not perform the procedure correctly. Also, damage to the predate or other property, may occur if the user does not perform the procedure correctly.
Task Alert message Page
Maintenance
Static, Damage
1. Don’t install or remove a PCA or connect or disconnect a cable or connector plug when the drive is powered. This may give you an electric shock.
2. Keep away from mechanical assemblies in the unit during operation. This may cause injuries.
3. Avoid dangerous detergent when the disk drive is cleaned.
1-2
C141-F075 v
Important Alert Items
Task Alert message Page
Maintenance
Device damage
1. Before touching a PCA or the drive, wear a wrist strap and perform the human body grounding to discharge static electricity from your body. This will prevent irreparable damage to the PCA and the head of the drive.
2. Don’t install or remove a PCA or connect or disconnect a cable or connector plug when the drive is powered. This will prevent electrical damage to the disk drive.
3. Operating the disk drive with one or more PCA missing will be unpredictable. Only power the drive with all boards installed.
4. Avoid any detergent which may cause short circuits when cleaning assemblies.
5. Keep all vents open opened and unblocked. Avoid other conditions which may cause circuits to overheat.
6. Do not apply excessive force to the cover under any circumstances. Doing so may cause irreparable damage to the cover.
Device damage
1-2
The DE is completely sealed. Do not open the DE in the
1-3
field.
Data corruption
When asking for repair, save all data stored in the disk drive
1-4 beforehand. Fujitsu Limited is not responsible for any loss of data during service and repair.
Device damage The disk enclosure (DE) must never to be opened in the
1-13 field. Opening the disk enclosure may cause irreparable damage.
vi C141-F075
Important Alert Items
Task Alert message Page
Maintenance
Damage or Device damage
1. Perform any removal after the system power is completely disconnected. The cable must not be disconnected and the screws that attach the drive must not be removed with the power ON.
2. Do not move the drive and attach or detach the connector until it comes to a complete stop (about 30 s after the power is turned OFF).
3. Perform the human body grounding to discharge any static electricity from your body. (Be sure to wear a wrist strap)
2-2
C141-F075 vii
This page is intentionally left blank.

Manual Organization

MHV2080BS, MHV2060BS
MHV2040BS
DISK DRIVES
PRODUCT MANUAL
(C141-E225)
MHV2080BS, MHV2060BS
MHV2040BS
DISK DRIVES
MAINTENANCE MANUAL
<This manual>
1. Device Overview
2. Device Configuration
3. Installation Conditions
4. Theory of Device Operation
5. Interface
6. Operations
1. Maintenance and Diagnosis