Fujitsu Inverter 9316796003-01 Operating Manual

KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE
FUJITSU GENERAL LIMITED
OPERATING MANUAL
P/N9316796003-01
HEAT & COOL MODEL (REVERSE CYCLE)
FLOOR TYPE
R410A
REFRIGERANT
This Air Conditioner contains and operates with refrigerant R410A and Polyol Ester oil.
THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED BY QUALIFIED PERSONNEL.
Refer to Commonwealth, State, Territory and local legislation, regulations, codes, installation & operation manuals, before the installation, maintenance and/or service of this product.
07J353_9316796003-01_cover.p65 2007.09.25, 19:321
1
CONTENTS
SAFETY PRECAUTIONS .......................................... 1
FEATURES AND FUNCTIONS ................................. 2
NAME OF PARTS ...................................................... 4
PREPARATION .......................................................... 5
OPERATION .............................................................. 6
TIMER OPERATION .................................................. 8
SLEEP TIMER OPERATION ...................................... 9
ADJUSTING THE DIRECTION OF
AIR CIRCULATION .................................................. 10
AIR OUTLET SELECTION ....................................... 11
10°C HEAT OPERATION ......................................... 12
ECONOMY OPERATION......................................... 12
SWING OPERATION............................................... 13
COIL DRY OPERATION ........................................... 13
MANUAL AUTO OPERATION................................ 13
CLEANING AND CARE ........................................... 14
TROUBLESHOOTING ............................................. 16
OPERATING TIPS.................................................... 18
SAFETY PRECAUTIONS
Do not attempt to install this air conditioner by yourself.
This unit contains no user-serviceable parts. Always consult authorized service per-
sonnel for repairs.
When moving, consult authorized service personnel for disconnection and installa­tion of the unit.
Do not become excessively chilled by staying for lengthy periods in the direct cooling airflow.
Do not insert anything into the Airflow direction.
Do not start and stop air conditioner operation by disconnecting the power supply
cord and so on.
Take care not to damage the power supply cord.
In the event of a malfunction (burning smell, etc.), immediately stop operation, dis-
connect the power supply plug, and consult authorized service personnel.
If the power supply cord of this appliance is damaged, it should only be replaced by the authorized service personal, since special purpose tools and specified cord are required.
Provide occasional ventilation during use.
Do not direct air flow at fireplaces or heating apparatus.
Do not climb on, or place objects on, the air conditioner.
Do not hang objects from the indoor unit.
Do not set flower vases or water containers on top of air conditioners.
Do not expose the air conditioner directly to water.
Do not operate the air conditioner with wet hands.
Do not pull power supply cord.
Turn off power source when not using the unit for extended periods.
Check the condition of the installation stand for damage.
Do not place animals or plants in the direct path of the air flow.
Do not drink the water drained from the air conditioner.
Do not use in applications involving the storage of foods, plants or animals, precision
equipment, or art works.
Connection valves become hot during Heating; handle with care.
Do not apply any heavy pressure to radiator fins.
Operate only with air filters installed.
Do not block or cover the intake grille and outlet port.
Ensure that any electronic equipment is at least one metre away from either the in-
door or outdoor units.
Avoid installing the air conditioner near a fireplace or other heating apparatus.
When installing the indoor and outdoor unit, take precautions to prevent access to
infants.
Do not use inflammable gases near the air conditioner.
Do not sit and place anything on the unit.
WARNING!
CAUTION!
2
FEATURES AND FUNCTIONS
INVERTER
At the start of operation, a large power is used to bring the room quickly to the desired temperature. Afterwards, the unit automatically switches to a low power setting for eco­nomic and comfortable operation.
COIL DRY OPERATION
The Indoor unit can be dried by pressing the COIL DRY but­ton on the Remote Control Unit so as to avoid going moldy and restrain the breed of bacterium.
AUTO CHANGEOVER
The operation mode (cooling, dry, heating) is switched au­tomatically to maintain the set temperature, and the tem­perature is kept constant at all times.
10°C HEAT OPERATION
The room temperature can be maintained at 10°C so as to prevent the room temperature from falling too far.
PROGRAM TIMER
The program timer allows you to integrate OFF timer and ON timer operations in a single sequence. The sequence can involve one transition from OFF timer to ON timer, or from ON timer to OFF timer, within a twenty-four hour pe­riod.
SLEEP TIMER
When the SLEEP button is pressed during Heating mode, the air conditioner’s thermostat setting is gradually lowered during the period of operation; during cooling mode, the thermostat setting is gradually raised during the period of operation. When the set time is reached, the unit automati­cally turns off.
WIRELESS REMOTE CONTROL UNIT
The Wireless Remote Control Unit allows convenient con­trol of air conditioner operation.
SWING OPERATION
The Air Flow Direction Louvers swings automatically up and down so that the air speeds to every nook and corner of your room.
REMOVABLE OPEN PANEL
The indoor unit’s Open Panel can be removed for easy clean­ing and maintenance.
MILDEW-RESISTANT FILTER
The AIR FILTER has been treated to resist mildew growth, thus allowing cleaner use and easier care.
SUPER QUIET OPERATION
When the FAN CONTROL button is used to select QUIET, the unit begins super-quiet operation; the indoor unit’s air­flow is reduced to produce quieter operation.
POLYPHENOL CATECHIN AIR CLEANING FILTER
The polyphenol catechin air cleaning filter uses static elec­tricity to clean the air of fine particles and dust such as to­bacco smoke and plant pollen that are too small to see. The filter contains catechin, which is highly effective against various bacteria by suppressing the growth of the bacteria adsorbed by the filter. Note that when the air cleaning filter is installed, the amount of air produced decreases, causing a slight decrease in the air conditioner's performance.
NEGATIVE AIR IONS DEODORIZING FILTER
It comprises pottery super micro particles, which can pro­duce negative air ions having the effect of deodorizing and can absorb and remit the peculiar smell at home.
3
E
F
9
9
4
1
A =
D
C
1
4
G B
7
TIMER6OPERATION5810˚c HEAT
2 3
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 6
To facilitate explanation, the accompanying illustra­tion has been drawn to show all possible indicators; in actral operation, however, the display will only show those indicators appropriate to the current op­eration.
Fig. 5
10˚c HEAT10˚c HEAT
MODEMODE
ECONOMYECONOMY
SWING
M
Y
[
`
a
P
Q
I J
L
H
N W
S
T
U O V
b c
]
Z
d
X
K
R
\
4
NAME OF PARTS
Fig. 5 Remote Control Unit
H SLEEP button I MODE button J 10°C HEAT button K SET TEMP. button (
/ )
L COIL DRY button M Signal Transmitter N TIMER MODE button O TIMER SET (
/ ) button
P FAN CONTROL button Q ECONOMY button R START/STOP button S SET button T SWING button U RESET button V TEST RUN button
This button is used when installing the conditioner, and should not be used un­der normal conditions, as it will cause the air conditioner’s thermostat function to op­erate incorrectly.
If this button is pressed during normal op­eration, the unit will switch to test opera­tion mode, and the Indoor Unit’s OPERA­TION Indicator Lamp and TIMER Indicator Lamp will begin to flash simultaneously.
To stop the test operation mode, press the START/STOP button to stop the air condi­tioner.
W CLOCK ADJUST button X Remote Control Unit Display (Fig. 6) Y Transmit Indicator Z Clock Display [ ECONOMY Display \ Operating Mode Display ] Timer Mode Display ` Fan Speed Display a Temperature SET Display b COIL DRY Display c SLEEP Display d SWING Display
Fig. 1 Indoor Unit
1 Operating Control Panel (Fig. 2) 2 Air Outlet Selection switch 3 MANUAL AUTO button
When kept on pressing the MANUAL AUTO button for more than 10 seconds, the forced cooling operation will start.
The forced cooling operation is used at the
time of installation. Only for authorized service personnel's use.
When the forced cooling operation starts
by any chance, press the START/STOP but­ton to stop the operation.
4 Indicator (Fig. 3) 5 Remote Control Signal Receiver 6 OPERATION Indicator Lamp (green) 7 TIMER Indicator Lamp (orange)
If the TIMER indicator lamp flashes when the timer is operating, it indicates that a fault has occurred with the timer setting (See Page 18 Auto Restart).
8 10°C HEAT Indicator Lamp (green)
9 Intake Grille (Fig. 4) 0 Front Panel A Air Filter B Air Flow Direction Louver C Damper D Right-Left Louver
(behind Air Flow Direction Louver and Damper)
E Drain Hose F Air Cleaning Filter G Rope
5
PREPARATION
CAUTION!
Take care to prevent infants from accidentally swallowing batteries.
When not using the Remote Control Unit for an extended period, remove the batteries to avoid possible leakage and damage to the unit.
If leaking battery fluid comes in contact with your skin, eyes, or mouth, immedi­ately wash with copious amounts of water, and consult your physician.
Dead batteries should be removed immediately and disposed of properly, either in a battery collection receptacle or to the appropriate authority.
Do not attempt to recharge dry batteries.
Never mix new and used batteries, or batteries of different types. Batteries should last about one year under normal use. If the Remote Con­trol Unit’s operating range becomes ap­preciably reduced, replace the batteries and press the RESET button with the tip of a ballpoint pen or other small object.
3 To remove the Remote
Control Unit (when use at hand).
1 Mount the Holder. 2 Set the Remote Control
Unit.
Screws
Insert
Press in
Slide up
Pull out
Load Batteries (R03/LR03
××
××
× 2)
1
Press and slide the battery compartment lid on the re­verse side to open it.
Slide in the direction of the arrow while pressing the mark.
2
Insert batteries.
Be sure to align the battery polarities ( ) correctly.
3
Close the battery compartment lid.
Set the Current time
1
Press the CLOCK ADJUST button (Fig. 5 W).
Use the tip of a ball-point pen or other small object to press the button.
2
Use the TIMER SET ( / ) buttons (Fig. 5 O) to adjust the clock to the current time.
button: Press to advance the time. button: Press to reverse the time.
(Each time the buttons are pressed, the time will be advanced/reversed in one-minute increments; hold the buttons depressed to change the time quickly in ten-minute increments.)
3
Press the CLOCK ADJUST button (Fig. 5 W) again.
This completes the time setting and starts the clock.
To Use the Remote Control Unit
The Remote Control Unit must be pointed at signal receiver (Fig. 1 5) to operate correctly.
Operating Range: About 7 meters.
When a signal is properly received by the air conditioner, a beeping sound will be
heard.
If no beep is heard, press the Remote Control Unit button again.
Remote Control Unit Holder
Loading...
+ 14 hidden pages