Fujitsu M800, G800, C300, HS900, L800 User Manual

...
1
(November / 1999)
CPU slot RAM module slot
3.5 inch HDD Bay 5 inch Bay RS-232C PCI slot ISA slot Redundant PSU Others
Index Key to
Or
And
The numbers on the left hand side of each page correspond to the various options available with teamservers as follows :
Notes ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P2 teamserver HS900-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P9 teamserver M800 series --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P11 teamserver L800 series---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P13 teamserver G800 series --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P14 teamserver C800 series---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P15 teamserver C300 series---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P16 teamserver C350ie---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P17 teamserver Network Cards-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P17 teamserver Internal Devices---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P18 teamserver External Devices--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P19 teamserver Rackmount ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P20 Hardware ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P21
System Configuration Guide (V.6
)
2
NOTES
Mounting internal devices in HS900
This System Configuration Guide (V.6) introduces PentiumIIl 450MHz, 500MHz, 550MHz, 600MHz and Pentiumlll Xeon 550MHz models and withdraws all old models. Please refer to http://www.fujitsu.co.jp/hypertext/InfoPro/msp/teamserver/config.html for old models.
In HS900, there are two HDD bays (9GB/18GB/36GB disks are available) as system disks. Storage System (GP5UR1DC4) is required for data storage. HS900 has no internal 5" bay in chassis, so Backup Cabinet (GP5UR1BC1) is required to mount backup devices.
Mounting internal HDDs in M800i
SCSI Card (GP5-127) or RAID Card (GP5-144/146) is required to setup hard disks. Storage System (GP5UR1DC4) is required when more than 7HDDs are installed. 14HDDs in total can be mounted in Pedestal version.
Mounting internal HDDs in L800i
L800i have eight HDD bays and up to six 36.4GB HDD can be mounted.
36.4GB HDD cannot be mounted in bays #7 and #8. However 18.2GB HDD can be mounted.
Mounting internal HDDs in G800i, C800i and C300i (except C850ie and C350ie)
G800i, C800i and C300i (except C850ie and C350ie) have eight HDD bays and 18.2GB HDD (1"height) can be mounted.
RCI(Remote Console Interface)
Restriction of Operating System (M800i/HS900)
Windows NT Server 4.0 supports up to 4CPUs and 4GB of memory. Windows NT Server 4.0 Enterprise Edition is required for more than 4CPUs and 4GB of Memory.
RCI(Remote Console Interface) support
The figure below indicates the availability of the RCI function on each server type.
O: Available(Std.), : Available(Opt.), X : N/A
-
: No server product type
Product Pedestal Rack C300 series X
­C800 series X X G800 series X O L800 series O M800 series O O HS900
-
O
3
NOTES
S.M.A.R.T.function
S.M.A.R.T. function is available in the conbinations shown below:
Internal Hard disk units Hard disk cabinet
IDE SCSI Hard disks GP5UR1DC4/GP5MS622A
Models
Standard equipment
Standard equipment
SCSI card RAID card
SCSI card
RAID card
GP5-125 GP5-126 GP5-127 GP5U141GP5U142 GP5-143 GP5-144 GP5-146 GP5-125 GP5-126 GP5-127 GP5U141 GP5-144 GP5-146
C300i (GP5C300-375) - --x- -- ■ -x-- C300i (GP5C377-379) -- -x- -- - - ■ x-- C800i - ---x- --■ --
-
x--
G800i - ----x-■■ -- x ■■ L800i - - -----■■ -- - ■■
M800i ---- ---■■ -- - ■■ HS900 - - -----■■ -- - ■■
Mounting additional memory
A memory board with 16slots is standard equipment and up to 16GB memory can be mounted. When you use over 16memory slots, an additional Memory Board (GP5-RB201) is required. When using two memory boards in HS900, the same memory size must be mounted on each board.
Additional PSU in G800i
When a DLT unit (GP5-DL351) is mounted, an additional PSU (total two PSU) is required. The restriction of the mount of 2 CPUs, 5HDD or 3 PCIs is cancelled.
(HS900)
Memory must be expanded in bank units by mounting four similar capacity DIMMs in one bank. DIMMs must also be mounted in ascending order of memory capacity alternately on the two RAM base cards.
(M800i)
Mount the same capacity DIMM's in units of four. (Mounting of DIMM's with different capacities or a set of less than four DIMM's is not allowed) Mount the DIMM's in ascending order of their capacity. Use DIMM slots in the order from bank A (J1 to J4) to bank D (J13 to J16)
(L800i)
The motherboard has four slots for RAM modules (including standard equipment), install RAM modules in slot number order. (teamserver C3xxi has three slots)
(G800i/C800i/C300i)
:
Corresponds , x:Does not correspond , -:N/A
NOTES
Hard disk cabinet/RAID card/SCSI card
Hard disk cabinet GP5MS622A: Up to four can be connected to C300i, C800i, G800i and L800i.
: Up to six can be connected to M800i.
Note: The Operating System must be installed on an internal hard disk.
RAID card (GP5U141/GP5-144/GP5-146) Up to two Hard disk cabinets can be connected with one RAID card. (Up to three can be connected with one GP5-144 card) When connecting two GP5MS622A, GP5-144 RAID card is reguired on G800i, L800i, M800i and HS900. One GP5U141 cannot be used to connect external disk array (Hard disk cabinet) and internal disk array. One GP5-146 in G/L800i cannot be used to connect external disk array (Hard disk cabinet) and internal disk array. One RAID card can not be used for botn internal and external array configuration. 2 RAID cards are reguired in this case. GP5-144/146 can only be used with GP5-144/146, they cannot be mixed with GP5U141/142/-143. Up to two GP5-146 can be used for internal array configuration in G800i. When connecting three RAID cards in G800i, the internal HDD must be connected using GP5-144.
RAID card (GP5U142/GP5-143) Only for use with internal HDD. Only one RAID card can be used per server.
SCSI card (GP5-125/GP5-126/GP5-127) Internal and external devices cannot be connected to the same SCSI card. Maximum number of daisy chain connections allowed : (1) Up to four external devices (but not Hard disk cabinets) can be connected by daisy chain. (2)Only one Hard disk cabinet can be connected. (Daisy chain connection is not available)
Disk array configuration
• Physical pack
• • • • • • • • • • • • • • • •
A collection of physical HDDs comprising a RAID.
• Logical drive
• • • • • • • • • • • • • • • • •
Logical drive (ex. D: ) seen by the Operating System.
• Partition
• • • • • • • • • • • • • • • • • • • • • • •
One of the logical access units into which a logical drive is divided.
Partition 1 Partition 2
HDD HDD HDD HDD
Logical drive A
Logical drive B
* Drives can be divided into partition.
Logical drive C
Physical pack
<Restrictions> (1) Physical pack must contain the same type(size) of HDDs. (2) Maximum logical drive size is 2TB (GP5U141/U142/-143/-144/-146).
4
5
NOTES
(3) The number of HDDs comprising a physical pack is as shown below.
RAID Level Discription HDDs Capacity of logical drives
RAID 0 2~8
RAID 1 2
RAID 5 3~8
RAID 6 3~8
(4) The same RAID level must be use when dividing a physical pack into a number of logical drives. (5) A physical pack must contain only HDDs which are connected by the same RAID card. (6) A RAID card can support more than one physical pack. ( even if different RAID levels) (7) Internal and external array devices cannot be connected to the same RAID card. (except for M8xx)
(
(
()
)
)
The data is broken down into blocks,each on a separate disk drive
The capacity of logical drive is same as the capacity of connected HDD.
Duplicates the disk and writes the same data onto two disks.
The capacity of the logical drive is half the capacity of connected HDD.
The data is broken down into blocks and each blocks is written together with parity bits on a separate disk drive.
The capacity of each logical drive is the number of connected HDDs - 1).
(
)
Duplicates the disk and broken down into blocks, each on a separate disk. (RAID0+1)
The capacity of each logical drive is the half the capacity of connected HDD. (GP5-143/144)
-
-
-
-
Product
Number of standard bus-slots
Product ID
Additional bus-slots The number of bus-slots which can be used depends on each model.
REMARKS
HS900 PCI(64bit-66MHz)x4 GP5T9A32R Two PCIs(64bit-33MHz) are used for standard LAN card and
PCI(64bit-33MHz)x6 GP5T9A22R standard RAID card.
M890ie PCI(64bit)x5 GP5M895AL GP5M895BL LAN card is mounted in a PCI(32bit)slot. M880ie PCI(32bit)x5 GP5M885AL GP5M885BL
PCI/ISA(32bit)x1
L890ie PCIx6 GP5L895L GP5L895LR LAN card is mounted in a PCIslot. L880ie PCI/ISAx1 GP5L885L GP5L885LR L870ie GP5L875L GP5L875LR
G870ix PCIx4 GP5G879L GP5G879LR All of the slots are available G870ie PCI/ISAx1 GP5G878L GP5G878LR G870i ISAx1 GP5G877L GP5G877LR
C870ix PCIx3 GP5C876 GP5C876R All of the slots are available C870ie ISAx2 GP5C875 GP5C875R C870i GP5C871 GP5C871R C850ie GP5C855 GP5C855R
C370ix PCIx4 GP5C379 All of the slots are available C370ie ISAx1 GP5C378 C370i GP5C377 C350ie GP5C355
NOTES
6
HS900 M800i
Cards Product ID Bus
Maximum number of cards mounted
Total
REMARKS
Cards Product ID Bus
Maximum number of cards mounted
Total
REMARKS
RAID card (Ultra2 Wide LVD) GP5-144 PCI64 7 8
RAID card (Ultra2 Wide LVB)
Standard equipment
PCI64 1
RAID card (Ultra2 Wide LVD) GP5-144 PCI64 5 5
RAID card (Ultra2 Wide LVD) GP5-146 PCI64 7
RAID card (Ultra2 Wide LVD) GP5-146 PCI64 4
SCSI card (Ultra2 Wide LVD) GP5-127 PCI64 6
SCSI card (Ultra2 Wide LVD) GP5-127 PCI64 5
SCSI card (Ultrawide Diff) GP5-123 PCI64 2 For external disk array
SCSI card (Ultrawide Diff) GP5-123 PCI64 2 For external disk array
Fibre Channel Card GP5-FC101 PCI64 2 2
4
Fibre Channel Card GP5-FC101 PCI64 2 2
LAN card (1000Base-SX)
GP5-183 PCI64 1
LAN card (1000Base-SX)
GP5-183 PCI64 1
LAN card (100Base-TX) GP5-185 PCI64 3
LAN card (100Base-TX) GP5-185 PCI32 3
4
LAN card (100Base-TX)
Standard equipment PCI64 1
LAN card (100Base-TX)
Standard equipment PCI32 1 Mounted in PCI slot3(fixed)
Server Monitor Module GP5USM103 PCI64 1 1
Server Monitor Module
GP5USM102
PCI32 1 1
* Up to six cards can be mounted when an ISA card is used.
L800i G800i
Cards Product ID Bus
Maximum number of cards mounted
Total
REMARKS
Cards Product ID Bus
Maximum number of cards mounted
Total
REMARKS
SCSI card (Ultrawide Diff) GP5-123 PCI 2 For external disk array
SCSI card (Ultrawide Diff) GP5-123 PCI 2
5
For external disk array
SCSI card (Ultra2 Wide LVD) GP5-127 PCI 3
GP5-127can beused to connect internal SCSI devices(GP5-DL351,GP5-ML301).
SCSI card (Ultra2 Wide LVD) GP5-127 PCI 3
3
3
Use for external SCSI devices
RAID card (Ultra2 Wide LVD) GP5-144 PCI 3 RAID card (Ultra2 Wide LVD) GP5-146 PCI 2
RAID card (Ultrawide SE) GP5U141 PCI 2 Internal/external array configuration
Fibre Channel Card GP5-FC101 PCI 2
RAID card (Ultrawide) GP5U142 PCI 1 Only for internal array configuration
LAN card (1000Base-SX)
GP5-183 PCI 1 It must be mounted in PCI-A2
RAID card (Ultra2 Wide LVD) GP5-144 PCI 3
Internal/external array configuration Cannot be used with GP5U141/142
LAN card (100Base-TX) GP5-185 PCI 3
LAN card (100Base-TX)
Standard equipment PCI 1 Mounted in PCI-A1(fixed)
RAID card (Ultra2 Wide LVD) GP5-146 PCI 2
Internal/external array configuration Cannot be used with GP5U141/142
Server Monitor Module GP5USM102 PCI 1 It must be mounted in PCI-A3
Fibre Channel Card GP5-FC101 PCI 2
* Up to six cards can be mounted when an ISA card is used.
LAN card (1000Base-SX)
GP5-183 PCI 1
LAN card (100Base-TX) GP5-184 PCI 3
Server Monitor Module
GP5USM102
PCI 1
C800i C300i (GP5C377-379)
Cards Product ID Bus
Maximum number of cards mounted
Total
REMARKS
Cards Product ID Bus
Maximum number of cards mounted
Total
REMARKS
RAID card (Ultrawide SE) GP5U141 PCI 2 3 Internal/external array configuration SCSI card GP5-126 PCI 1 3
RAID card (Ultrawide SE) GP5-143 PCI 1 Only for internal array configuration SCSI card GP5-127 PCI 3
SCSI card GP5-125 PCI 3 Only for external SCSI devices
RAID card (Ultrawide SE) GP5U141 PCI 2 Internal/external array configuration
LAN card (1000Base-SX)
GP5-183 PCI 1 3
RAID card (Ultra2 Wide LVD) GP5-143 PCI 1
LAN card (100Base-TX) GP5-185 PCI 3 LAN card (100Base-TX) GP5-185 PCI 3 3
Server Monitor Module GP5USM102 PCI 1 Server Monitor Module
GP5USM102
PCI 1 1
C300i (GP5C300-375)
Cards Product ID Bus
Maximum number of cards mounted
Total
REMARKS
SCSI card GP5-125 PCI 3 3 RAID card
(Ultrawide SE) GP5U141 PCI 2 Internal/external array configuration
Only for internal array configuration (Cannot be used with GP5-143)
RAID card (Ultra2 Wide LVD) GP5-143 PCI 1
Only for internal array configuration
(Cannot be used with GP5U142) LAN card (100Base-TX) GP5-185 PCI 3 3 Server Monitor Module GP5USM102 PCI 1 1
2
3
7*
4
Number of mountable optional cards
7
NOTES
1. Connectivity/Use of new product options with older models I. The figure below indicates the applicability of new options on previous (released before August, 1999) models Figure1
II. Ultra wide or Ultra2 Wide on C300 series
The new C300 series (GP5C377, GP5C378, GP5C379) supports Ultra2 Wide SCSI. To use new C300 series as an Ultra2 Wide system, Ultra2 Wide HDD, Ultra2 Wide SCSI (RAID) card and Ultra2 Wide SCSI cable are required Previous models (GP5C300 to GP5C375 - Released Jul,1999) cannot support Ultra2 Wide even if Ultra2 Wide SCSI HDD, card & cable are mounted. For connection details, please refer to "Available SCSI cards for C300i"
Product Option Product ID Applicable
to older
Remarks
C300series
Hard disk drive-9GB GP5-HD9G3 O Please refer to Figure2
Hard disk drive-18GB GP5-HD8G1
O
Hard disk drive-13GB GP5-HD3E1 O LAN card GP5-185 O Successor of GP5-182/184 SCSI card GP5-127
X
SCSI card GP5-126 X RAID card GP5-143 O However, used as Ultrawide SCSI interface in older models SCSI cable GP5-839
X
GP5-840 X GP5-841 O Successor of GP5-838
Hard disk cabinet GP5MS622A
O Successor of GP5MS621A
C800series Hard disk drive-9GB GP5-HD9G3 O Please refer to Figure2
Hard disk drive-9GB GP5-HDH96
O Please refer to Figure2
Hard disk drive-18GB GP5-HD8G1
O Please refer to Figure2
Hard disk drive-18GB GP5-HDH83
O Please refer to Figure2
LAN card GP5-185
O Successor of GP5-182/184
Hard disk cabinet GP5S622A
O Successor of GP5MS621A
G800 series Hard disk drive-9GB GP5-HDH96 O Please refer to Figure2
Hard disk drive-18GB GP5-HDH83
O Please refer to Figure2
LAN card GP5-185
O Successor of GP5-182/184
SCSI card GP5-127
O Successor of GP5-125/GP5-126
RAID card GP5-146
O Successor of GP5-145 with Windows NT only
For Netware/Intranetware, please use GP5-145
Hard disk cabinet GP5MS622A
O Successor of GP5MS621A
DLT unit GP5-DL351
O Two PSU (one is standard) are required when mounting GP5-DL351
L800 series Hard disk drive-9GB GP5-HDH97 O Please refer to Figure2
Hard disk drive-9GB GP5-HDH98
O Please refer to Figure2
Hard disk drive-18GB GP5-HDH84
O Please refer to Figure2
Hard disk drive-18GB GP5-HDH85
O Please refer to Figure2
Hard disk drive-36GB GP5-HDH61
O New
LAN card GP5-185
O Successor of GP5-182/184
SCSI card GP5-127
O Successor of GP5-125/GP5-126
RAID card GP5-146
O
Hard disk cabinet GP5MS622A O Successor of GP5MS621A RCI card GP5-RC101
O New for Pedestal type, Standard equipment for Rackmount type
M800 series Hard disk drive-9GB GP5-HDH97 O Please refer to Figure2
Hard disk drive-9GB GP5-HDH98
O Please refer to Figure2
Hard disk drive-18GB GP5-HDH84
O Please refer to Figure2
Hard disk drive-18GB GP5-HDH85
O Please refer to Figure2
Hard disk drive-36GB GP5-HDH61
O New
LAN card GP5-185
O Successor of GP5-182/184
SCSI card GP5-127
O Successor of GP5-125/GP5-126
RAID card GP5-146
O
Hard disk cabinet GP5MS622A O Successor of GP5MS621A
Hard disk drive-9GB GP5-HD9G3B O Please refer to Figure2
Hard disk drive-18GB GP5-HD8G1B O
The differentiation between current models and new models
NOTES
8
2.Internal HDD The HDD line-up has changed. The figure below indicates each product and its successor.
Current and successor HDDs of the same size can be used together in the same physical pack. Figure 2
Main un i t Product Current HDD Succesor HDD Remarks
Product ID Product ID
C300 series Hard disk drive-4GB GP5-HD4G5 GP5-HD4G51
GP5-HD4G5B For mounting in 5" bay
Hard disk drive- 9G B GP5-HD9G2 GP5-HD9G3
GP5-HD9G3B For mounting in 5" bay
C800 series Hard disk drive-4GB GP5-HD4G5 GP5-HD4G51
Hard disk drive- 4GB GP5-HDH44 GP5-HDH461 Can be used with GP5-HDH46 Hard disk drive- 9G B GP5-HD9G3 GP5-HD9G3 Hard disk drive- 9G B GP5-HDH92 GP5-HDH96 Can be used with GP5-HDH95
G800 series Har d disk drive- 4GB GP5-HDH44 GP5-HDH461 Can be used with GP5-HDH46
Hard disk dr iv e -4 G B GP5-HDH46 GP5-HDH461 Hard disk drive- 9G B GP5-HDH92 GP5-HDH96 Can be used with GP5-HDH95
Hard disk dr i ve - 9 GB GP5-HDH95 GP5-HDH96 L800 series Hard d is k dr iv e- 4G B GP5-HDH45 GP5-HDH451 M800 series Hard disk drive-9GB GP5-HDH93 GP5-HDH97
Hard disk dr i ve - 9 GB GP5-HDH94 GP5-HDH98
Hard disk drive-18GB GP5-HDH81 GP5-HDH84
Hard disk drive-18GB GP5-HDH82 GP5-HDH85
Successor products of the same size can be used as additional HDD in a physical pack that contains current/previous products.
Available SCSI card for C300i
(1) GP5C377/378/379 (Ultra2 Wide) Connected device
SCSI card Channel Cable Remarks
Internal HDD GP5-126 Internal Channel
(68pin)
GP5-839 Up to four HDDs
Internal Backup device GP5-126 Internal Channel
(50pin)
GP5-841
GP5-127 Internal Channel
(68pin)
GP5-840 When using EIDE HDD or
RAID, GP5-127 must be used instead of GP5-126*
Hard disk cabinet GP5-127 External Channel
(68pin)
GP5MU823A
(2) GP5C300-375 (Ultra wide)
Connected device
SCSI card Channel Cable Remarks
Internal HDD (SCSI) GP5-125 Internal Channel
(68pin)
GP5-837 Up to four HDDs
Internal Backup device GP5-125 Internal Channel
(50pin)
GP5-841
Hard disk cabinet GP5-125 External Channel
(68pin)
GP5MU823A
# of SCSI Channel of each SCSI card is as below:
SCSI card Internal External
GP5-125 2(68pin+50pin) 1(68pin) GP5-126 2(68pin+50pin) 1(68pin) GP5-127 1(68pin) 1(68pin)
*SCSI card (GP5-126) is required for connecting SCSI HDD
9
System Configuration
Max. memory: 32GB
Max : 2
Max : 8
Max : 1
Max : 8CPUs
Standard memory : 1GB (128MB-DIMM8)
Standard : 2CPUs
teamserver HS900
teamserver HS900 series
Internal Hard Disk
Memory
CPU
CPU Field Upgrade Kit (Pentium®III Xeon™-550MHz (1MB) 1) GP5-FG202T
Additional Memory - 256MB (128MB-DIMM2) GP5-RM25J
Additional Memory - 512MB (256MB-DIMM2) GP5-RM51J
Additional Memory - 1024MB (512MB-DIMM2) GP5-RM1J
Up to two HDDs can be mounted in the main unit
CPU Field Upgrade Kit (Pentium®III Xeon™-550MHz (2MB) 1) GP5-FG203T
RAID Card (GP5-146 : std.)
SCSI on board
Connect with Storage System
GP5T9A32R [Rackmount Type]
2CPU, Memory:1GB(ECC), HDD:Option
GP5T9A22R [Rackmount Type]
2CPU, Memory:1GB(ECC), HDD:Option
CPU: Pentium®lll Xeon(550MHz) x 2(~8) , Cache (L1+L2) : 32KB+2MB/1MB, Internal Hard disk bay:(Hot-plug) 2bays,
2 x Ultra2 Wide SCSI Onboard, 2ch RAID Card, CD-ROM, LAN Card (Std.), Redundant Power Supply (Std.)/FAN (Std.), Intel LANDesk® Server Manager/Servervisor, ServerWizard
Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH98T
Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH85T
Hard Disk Drive - 36GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH61T
Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH98
Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH85
Hard Disk Drive - 36GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH61
e
y
y
SCSI Card (Ultra2 Wide) GP5-127
Storage System GP5UR1DC4
SCSI Cable(5m) GP5S-833
SCSI Cable(10m) GP5S-834
SCSI Cable(3m) GP5MU823A
w
w
q
Additiond Memory Board GP5-RB201
[Rackmount type]
Additional Memory - 2048MB (1024MB-DIMM2) GP5-RM2J
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH97
Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH84
Redundant Power Supply Unit GP5U R1PU1
10
System Configuration
Server Monitor Module GP5USM103
y
RAID Card
*
(Cache : 32MB
Ultra2 Wide SCSI) GP5-144
RAID Card
*
(Cache : 16MB
Ultra2 Wide SCSI) GP5-146
SCSI Cable GP5S-832
Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH98
Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH85
Hard Disk Drive - 36GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH61
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH97
Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH84
(Please refer to P.18)
Storage System GP5UR1DC4
Backup Cabinet GP5UR1BC1
Up to four Back up devices
Redundant Power Supply Unit GP5UPU151
SCSI Cable GP5S-835
SCSI Cable GP5S-836
SCSI Cable GP5S-832
y
o
System Configuration
11
teamserver M800 series
CPU: Pentium®lll Xeon(550MHz) x 1(~4) , Cache (L1+L2) : 32KB+2MB/1MB, Internal Hard disk bay:(Hot-plug) 14bays (Pedestal)/6bays(Rackmount)
CD-ROM, LAN Card (Std.), Redundant Power Supply (Opt.)/FAN (Std.), Servervisor/ Intel LANDesk® Server Manager, ServerWizard
M890ie GP5M895AL [1CPU/Pedestal Type]
1CPU, Memory:256MB(ECC), HDD:Option
GP5M895BL [1CPU/Rackmount Type]
1CPU, Memory:256MB(ECC), HDD:Option
M880ie GP5M885AL [1CPU/Pedestal Type]
1CPU, Memory:256MB(ECC), HDD:Option
GP5M885BL [1CPU/Rackmount Type]
1CPU, Memory:256MB(ECC), HDD:Option
CPU
Internal Hard Disk
Memory
Additional Memory - 512MB (128MB-DIMM4) GP5-RM51G
AdditionalMemory- 1024MB (256MB-DIMM4) GP5-RM1G
q
w
Standard memory : 256MB (64MB-DIMM4)
Max : 8GB
For pedestal type
Max : 4CPUs
Pedestal Type : Up to 14 (6 in standard, 8 in optional Storage System)
disks can be installed.
Rackmount Type : Up to 6 disks can be installed in a rackmount
type node.
[Rackmount type]
Additional Memory- 256MB (64MB-DIMM4) GP5-RM25G
Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH84
Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH85
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH97
Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH98
y
SCSI Card (Ultra2 Wide) GP5-127
Hard Disk Drive - 36GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH61
Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH84
Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH85
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH97
Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH98
Hard Disk Drive - 36GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH61
(1)Disk Addition / Duplexing
Redundant Power Supply Unit GP5UR1PU1
y
Storage System GP5UR1DC4
SCSI Cable(3m) GP5MU823A
[Pedestal type]
teamserver M800 series
CPU Field Upgrade Kit (Pentium®III Xeon™
-550MHz (1MB)
1)
GP5-FG202
SCSI Card (Ultra2 Wide) GP5-127
CPU Field Upgrade Kit (Pentium®III Xeon™
-550MHz (2MB)
1)
GP5-FG203
12
System Configuration
Redundant Power Supply Unit GP5UPU141
i
y
RAID Card
*
(Cache : 32MB
Ultra2 Wide SCSI) GP5-144
Storage System GP5UR1DC4
SCSI Cable GP5S-832
RAID Card
*
(Cache : 16MB
Ultra2 Wide SCSI) GP5-146
Hard Disk Drive - 18GB (
Ultra2 Wide.
7,200rpm) (Hot Plug) GP5-HDH84
Hard Disk Drive - 18GB (
Ultra2 Wide.
10,000rpm) (Hot Plug) GP5-HDH85
Hard Disk Drive - 9GB (
Ultra2 Wide.
7,200rpm) (Hot Plug) GP5-HDH97
Hard Disk Drive - 9GB (
Ultra2 Wide.
10,000rpm) (Hot Plug) GP5-HDH98
Hard Disk Drive - 9GB (
Ultra2 Wide.
7,200rpm) (Hot Plug) GP5-HDH97
Hard Disk Drive - 9GB (
Ultra2 Wide.
10,000rpm) (Hot Plug) GP5-HDH98
Hard Disk Drive - 18GB (
Ultra2 Wide.
7,200rpm) (Hot Plug) GP5-HDH84
Hard Disk Drive - 18GB (
Ultra2 Wide.
10,000rpm) (Hot Plug) GP5-HDH85
Redundant Power Supply Unit GP5UR1PU1
Hard Disk Drive - 36GB (
Ultra2 Wide.
10,000rpm) (Hot Plug) GP5-HDH61
Hard Disk Drive - 36GB (
Ultra2 Wide.
10,000rpm) (Hot Plug) GP5-HDH61
Server Monitor Module GP5USM102
y
NOTE ; Please reter to P.20 for rackmounting instructions.
*
For mounting restrictions, please see P.4
For pedestal type
13
System Configuration
teamserver L800 series
teamserver L800 series
CPU: Pentium®lll Xeon(550MHz) x 1(~4) , Cache (L1+L2) : 32KB+2MB/1MB/512KB, On board SCSI,
Internal Hard disk bay: 8bays (Hot-plug), CD-ROM, LAN Card (Std.), Servervisor/Intel LANDesk® Server Manager, ServerWizard
L890ie GP5L895L [1CPU/Pedestal Type]
1CPU(Cache:2MB), Memory:256MB(ECC), HDD:Option
GP5L895LR [1CPU/Pedestal Type]
1CPU(Cache:2MB), Memory:256MB(ECC), HDD:Option
L880ie GP5L885L [1CPU/Pedestal Type]
1CPU(Cache:1MB), Memory:256MB(ECC), HDD:Option
GP5L885LR [1CPU/Pedestal Type]
1CPU(Cache:1MB), Memory:256MB(ECC), HDD:Option
L870ie GP5L875L [1CPU/Pedestal Type]
1CPU(Cache:512KB), Memory:256MB(ECC), HDD:Option
GP5L875LR [1CPU/Pedestal Type]
1CPU(Cache:512KB), Memory:256MB(ECC), HDD:Option
Max : 4GB
Max : 4CPSs
Memory
Additional Memory - 128MB (32MB-DIMM4) GP5-RM12G
Additional Memory - 256MB (64MB-DIMM4) GP5-RM25G
Additional Memory - 512MB (128MB-DIMM4) GP5-RM51G
Additional Memory - 1024MB (256MB-DIMM4) GP5-RM1G
w
Standard memory : 256MB (64MB-DIMM✕4)
Redundant Power Supply Unit GP5UPU131
i
Internal Disk Array
y
y
RAID Card (Cache : 32MB,
*
Ultra2 Wide SCSI) GP5-144
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH97
Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH84
Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH98
Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH85
e
(1)Disk Addition / Duplexing
Up to 8 disks can be installed Bay 1~6 : 9.1GB/18.2GB/36.4GB
Bay 7~8 : 9.1GB/18.2GB
Internal Hard Disk
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH97
Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH84
Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH98
Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH85
Hard Disk Drive - 36GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH61
CPU Field Upgrade Kit (Pentium®III Xeon
-550MHz (512KB)
1)
GP5-FG201 (for L870ie)
Server Monitor Module GP5USM102
y
Hard Disk Drive - 36GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH61
RAID Card (Cache : 16MB,
*
Ultra2 Wide SCSI) GP5-146
o
*
For mounting restrictions, please see P.4
[Pedestal type]
[Rackmount type]
CPU
q
CPU Field Upgrade Kit (Pentium®III Xeon
-550MHz (1MB)
1)
GP5-FG202 (for L880ie)
CPU Field Upgrade Kit (Pentium®III Xeon
-550MHz (2MB)
1)
GP5-FG203 (for L890ie)
RCI Card GP5-RC101 (Standard Equipment for Rackmount type)
teamserver G800 series
CPU: Pentium®lll (600MHz/550MHz/500MHz) x 1(~2) , Cache (L1+L2) : 32KB+512KB, On board SCSI,
CD-ROM, Onboard LAN (Std.), Internal Hard disk bay: 8bays (Hot-plug), Servervisor/ Intel LANDesk® Server Manager, ServerWizard
G870ix GP5G879L [1CPU/Pedestal Type]
1CPU(Pentiumlll 600MHz), Memory:256MB(ECC), HDD:Option
GP5G879LR [1CPU/Rackmount Type]
1CPU(Pentiumlll 600MHz), Memory:256MB(ECC), HDD:Option
G870ie GP5G878L [1CPU/Pedestal Type]
1CPU(Pentiumlll 550MHz), Memory:256MB(ECC), HDD:Option
GP5G878LR [1CPU/Rackmount Type]
1CPU(Pentiumlll 550MHz), Memory:256MB(ECC), HDD:Option
G870i GP5G877L [1CPU/Pedestal Type]
1CPU(Pentiumlll 500MHz), Memory:256MB(ECC), HDD:Option
GP5G877LR [1CPU/Rackmount Type]
1CPU(Pentiumlll 500MHz), Memory:256MB(ECC), HDD:Option
System Configuration
teamserver G800 series (Jan.1999)
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH96
Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH83
y
(2)Internal Disk Array
Internal Hard Disk
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH96
Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH83
e
(1)Disk Addition / Duplexing
Up to 8 disks in a teamserver
RAID Card (Cache : 4MB, Internal use only) GP5U142
RAID Card (Cache : 32MB, Ultra2 Wide SCSI, BBU) GP5-144
RAID Card (Cache : 16MB, Ultra2 Wide SCSI, BBU) GP5-146
Redundant Power Supply Unit GP5UPU131
NOTE : 2 PSUs are required if GP5-DL351 is installed
Maximum 3PSUs can be instaled in G800i series.
14
[Rackmount type]
y
i
Server Monitor Module GP5USM102
Memory
Max : 2GB
Max : 2CPUs
Standard memory : 256MB (256MB SDRAM-DIMM1)
Additional Memory - 64MB (64MB SDRAM-DIMM1) GP5-RM64F
Additional Memory - 128MB (128MB SDRAM-DIMM1) GP5-RM12F
Additional Memory - 256MB (256MB SDRAM-DIMM1) GP5-RM25F
Additional Memory - 512MB (512MB SDRAM-DIMM1) GP5-RM51F
q
CPU Field Upgrade Kit (Pentium®III-500MHz (512KB) 1) GP5-FG10N (for G870i)
CPU Field Upgrade Kit (Pentium®III-550MHz (512KB) 1) GP5-FG10V (for G870ie)
CPU Field Upgrade Kit (Pentium®III-600MHz (512KB) 1) GP5-FG10Y (for G870ix)
CPU
w
[Pedestal type]
®
®
®
15
System Configuration
teamserver C800 series
teamserver C800 series
CPU: Pentium®lll (600MHz/550MHz/500/450MHz)x 1(~2) , Cache (L1+L2) : 32KB+512KB, On board SCSI,
CD-ROM, Onboard LAN (Std.), Internal Hard disk bay: 4bays (3xHot-plug), Servervisor/ Intel LANDesk® Server Manager, ServerWizard
C870ix GP5C876 [1CPU/Pedestal Type]
1CPU(Pentiumlll 600MHz), Memory:128MB(ECC), HDD:Option
GP5C876R [1CPU/Rackmount Type]
1CPU(Pentiumlll 600MHz), Memory:128MB(ECC), HDD:Option
C870ie GP5C875 [1CPU/Pedestal Type]
1CPU(Pentiumlll 550MHz), Memory:128MB(ECC), HDD:Option
GP5C875R [1CPU/Rackmount Type]
1CPU(Pentiumlll 550MHz), Memory:128MB(ECC), HDD:Option
C870i GP5C871 [1CPU/Pedestal Type]
1CPU(Pentiumlll 500MHz), Memory:128MB(ECC), HDD:Option
GP5C871R [1CPU/Rackmount Type]
1CPU(Pentiumlll 500MHz), Memory:128MB(ECC), HDD:Option
C850ie GP5C855 [1CPU/Pedestal Type]
1CPU(Pentiumlll 450MHz), Memory:128MB(ECC), HDD:Option
GP5C855R [1CPU/Rackmount Type]
1CPU(Pentiumlll 450MHz), Memory:128MB(ECC), HDD:Option
[Rackmount type]
Internal Hard Disk
Memory
Additional Memory - 64MB (64MB SDRAM-DIMM1) GP5-RM64F
Additional Memory - 128MB (128MB SDRAM-DIMM1) GP5-RM12F
Additional Memory - 256MB (256MB SDRAM-DIMM1) GP5-RM25F
Hard Disk Drive - 9GB (Ultra Wide.7,200rpm)(Hot Plug) GP5-HDH96
e
(1)Disk Addition to Hot Plug bays (Max . 3 disks)
Total 4 disks(3Hot Plug and 1non-Hot Plug) can be installed.
w
Hard Disk Drive - 18GB (Ultra Wide.7,200rpm)(Hot Plug) GP5-HDH83
Standard memory : 128MB (128MB SDRAM-DIMM1)
®
CPU
CPU Field Upgrade Kit (Pentium®III-600MHz (512KB) 1) GP5-FG10Y (for C870ix)
®
CPU Field Upgrade Kit (Pentium®III-550MHz (512KB) 1) GP5-FG10V (for C870ie)
q
CPU Field Upgrade Kit (Pentium®III-450MHz (512KB) 1) GP5-FG10W (for C850ie)
Max : 1GB
Max : 2CPUs
y
RAID Card (Cache : 16MB) GP5U141
(2)Internal Disk Array(Maximum 3Hot Plug disks can be installed)
GP5-831 SCSI Cable (Intl.)
Hard Disk Drive - 9GB (Ultra Wide.7,200rpm) (Hot Plug) GP5-HDH96
Hard Disk Drive - 18GB (Ultra Wide.7,200rpm) (Hot Plug) GP5-HDH83
Hard Disk Drive - 9GB (7,200rpm) (non-Hot Plug) GP5-HD9G3
e
only one disk can be installed
(3)Disk Addition to a non-Hot Plug bay
Hard Disk Drive - 18GB (7,200rpm) (non-Hot Plug) GP5-HD8G1
y
RAID Card (Cache : 8MB Internal Hard disk only) GP5-143
Server Monitor Module GP5USM102
[Pedestal type]
CPU Field Upgrade Kit (Pentium®III-500MHz (512KB) 1) GP5-FG10N (for C870i)
®
®
16
System Configuration
teamserver C300 series
teamserver C300 series
CPU: Pentium®lll (600MHz/550MHz/500MHz)x 1, Cache (L1+L2) : 32KB+512KB, CD-ROM, On board LAN (Std.)
Internal Hard disk bay: 4bays (use one 5" bay : non-hot-plug), Servervisor/ Intel LANDesk® Server Manager, ServerWizard
C370ix GP5C379 [1CPU/Pedestal Type]
1CPU(Pentiumlll 600MHz), Memory:128MB(ECC), HDD:Option
C370ie GP5C378 [1CPU/Pedestal Type]
1CPU(Pentiumlll 550MHz), Memory:128MB(ECC), HDD:Option
C370i GP5C377 [1CPU/Pedestal Type]
1CPU(Pentiumlll 500MHz), Memory:128MB(ECC), HDD:Option
Internal Hard Disk
Memory
Additional Memory-64MB (64MB SDRAM-DIMM 1) GP5-RM64H
Additional Memory-128MB (128MB SDRAM-DIMM 1) GP5-RM12H
Additional Memory-256MB (256MB SDRAM-DIMM 1) GP5-RM25H
Max : 768MB
Standard memory : 128MB(128MB-DIMM
1)
GP5-126 Can be used to connect 5 inch backup devices.
Hard Disk Drive-13GB (EIDE) (5400rpm) GP5-HD3E1(mounted in 3.5" bay)
Hard Disk Drive-9GB (Ultra2 Wide. 7200rpm) (non-Hot plug) GP5-HD9G3 (mounted in HDD bay, MAX:3) GP5-HD9G3B (mounted in 5" bay)
Hard Disk Drive-18GB (Ultra2 Wide. 7200rpm) (non-Hot plug) GP5-HD8G1 (mounted in HDD bay MAX:3) GP5-HD8G1B (mounted in 5" bay)
e
(1)Disk Addition
Max : 2
Max : 4disks
(EIDE Disk)
(SCSI Disk)
When the boot disk is SCSI, IDE disks can not be installed.
w
y
SCSI Card GP5-126
SCSI Cable GP5-839
Hard Disk Drive-9GB (Ultra2 Wide. 7200rpm) (non-Hot plug) GP5-HD9G3 (mounted in HDD bay MAX:3) GP5-HD9G3B (mounted in 5" bay)
y
(2) Internal Disk Array
SCSI Cable GP5-839
Hard Disk Drive-18GB (Ultra2 Wide. 7200rpm) (non-Hot plug) GP5-HD8G1 (mounted in HDD bay MAX:3) GP5-HD8G1B (mounted in 5" bay)
y
Server Monitor Module GP5USM102
RAID Card (Cache : 8MB, For internal HDD only) GP5-143
Max : 4
17
System Configuration
LAN Card GP5-185
Network Cards
y y
y
y
y y
y
teamserver
LAN Card GP5-183
teamserver C350ie
teamserver C350ie
CPU: Pentium®lll (450MHz) x 1, Cache (L1+L2) : 32KB+512KB, CD-ROM, LAN Card (Std.)
Internal Hard disk bay: 4bays (non-hot-plug), Servervisor, Intel LANDesk® Server Manager, System Walker, ServerWizard
C350ie GP5C355 [1CPU/Pedestal Type]
1CPU(Pentiumlll 450MHz), Memory:64MB(ECC), HDD:Option
Internal Hard Disk
Memory
Additional Memory-64MB (64MB SDRAM-DIMM 1) GP5-RM64H
Additional Memory-128MB (128MB SDRAM-DIMM 1) GP5-RM12H
Additional Memory-256MB (256MB SDRAM-DIMM 1) GP5-RM25H
Max : 768MB
Standard memory : 64MB-DIMM
1
Hard Disk Drive-13GB (EIDE) (5400rpm) GP5-HD3E1(mounted in 3.5" bay)
e
(1)Disk Addition
Max : 2
Max : 4disks
(EIDE Disk)
(SCSI Disk)
w
y
SCSI Card GP5-125
SCSI Cable GP5-837
Hard Disk Drive-9GB (Ultra Wide. 7200rpm) (non-Hot plug) GP5-HD9G2
y
(2) Internal Disk Array
SCSI Cable GP5-837
Hard Disk Drive-9GB (Ultra Wide. 7200rpm) (non-Hot plug) GP5-HD9G3 (mounted in HDD bay, MAX 3) GP5-HD9G3B (mounted in 5" bay)
Hard Disk Drive-18GB (Ultra Wide. 7200rpm) (non-Hot plug) GP5-HD8G1 (mounted in HDD bay, MAX 3) GP5-HD8G1B (mounted in 5" bay)
Hard Disk Drive-9GB (Ultra Wide. 7200rpm) (non-Hot plug) GP5-HD9G2
Hard Disk Drive-9GB (Ultra Wide. 7200rpm) (non-Hot plug) GP5-HD9G3 (mounted in HDD bay, MAX 3) GP5-HD9G3B (mounted in 5" bay)
Hard Disk Drive-18GB (Ultra Wide. 7200rpm) (non-Hot plug) GP5-HD8G1 (mounted in HDD bay, MAX 3) GP5-HD8G1B (mounted in 5" bay)
y
Server Monitor Module GP5USM102
RAID Card (Cache : 8MB, For internal HDD only) GP5-143
Max : 4
M800i L800i series
HS900 series
G800i C800i series
C300i series
18
System Configuration
teamserver Internal Devices
DLT unit (Occupied two 5" bay slots) GP5-DL351
Tape unit GP5-ML301
DLT unit (Occupied two 5" bay slots) GP5UDL201
DAT unit GP5UDT301
Tape unit GP5USL501
SCSI Cable GP5S-832
Up to four Tape units can be mounted
Backup Cabinet GP5UR1BC1
HS900
DLT unit (Occupied two 5" bay slots) GP5-DL351
Tape unit GP5-ML301
DLT unit (Occupied two 5" bay slots) GP5UDL201
DAT unit GP5UDT301
Tape unit GP5-NS201
Tape unit GP5USL501
M800i
L800i
series
y
r
SCSI Card GP5-127
Tape unit GP5-ML301
DLT unit (Occupied two 5" bay slots) GP5UDL201
DLT unit *(Occupied two 5" bay slots) GP5-DL351 Only G800i
DAT unit GP5UDT301
Tape unit GP5-NS201
Tape unit GP5USL501
G800i C800i
series
y
r
r
SCSI Card GP5-127
SCSI Card GP5-125
y
Only G800i
Only C800i
Only G800i
DAT unit GP5UDT301
Tape unit GP5-NS201
Tape unit GP5USL501
GP5C377 GP5C378 GP5C379
C300series
y
SCSI Card GP5-127
SCSI Card GP5-126
SCSI Card GP5-125
GP5C355
y
SCSI Cable GP5-841
SCSI Cable GP5-840
SCSI Cable GP5-841
o
Redundant Power Supply Unit GP5UPU151
*NOTE : 2 PSUs are required as standard if GP5­DL351 is installed
Maximum 3PSUs can be instaled in G800i series.
19
System Configuration
teamserver External Devices
Hard disk cabinet
Disk addition
(Pedestal only)
SCSI card GP5-125
SCSI cable GP5MU823A
Disk addition
SCSI card GP5-127
SCSI cable GP5MU823A
Disk array
RAID card(cache:16MB) GP5U141
SCSI cable GP5MU829A
y
y
Configuration of the inside Hard disk cabinet
Hard Disk Drive-9GB (7,200rpm) GP5-HDH97
Hard Disk Drive-9GB (10,000rpm) GP5-HDH98
Hard Disk Drive-18GB (7,200rpm) GP5-HDH84
Hard Disk Drive-18GB (10,000rpm) GP5-HDH85
Hard Disk Drive-36GB (10,000rpm) GP5-HDH61
Power Supply Unit GP5URIPU1
y y y
L/G800
only
L/G800
only
Hard disk cabinet GP5MS622A
y y
Disk array
RAID card(cache:32MB) GP5-144
SCSI cable GP5S-832
y y
Disk array
RAID card(cache:16MB) GP5-146
SCSI cable GP5S-832
C800
only
C350ie
only
G/C800
only
L/G800
only
M800 series
L800 G800 C800
series
C300
series
y
except
C350ie
GP5U141 can be used for Hard disk cabinet only when GP5U142 is used to connect internal hard disk array.
20
System Configuration
teamserver Rackmount
40U Rack & Rack Coupling kit GP5-R1RC5
24U Rack & Rack Coupling kit GP5-R2RC2
[Inside of Storage System]
Hard Disk Drive-9GB(7,200rpm) GP5-HDH97
Hard Disk Drive-9GB(10,000rpm) GP5-HDH98
Redundant Power Supply Unit
GP5UR1PU1
NOTE : A maximum of eight Hard Disk Drives can be installed in a Storage System.
In a RAID configuration, a physical pack must be comprised of the same type of Hard disks.
Hard Disk Drive-18GB(7,200rpm) GP5-HDH84
Hard Disk Drive-18GB(10,000rpm) GP5-HDH85
teamserver CPU nodes for Rackmount
Component Shelf GP5-R1TB4
Key board/Monitor Enhanced Switch GP5-SB101
Keyboard/Monitor Extention Cables GP5-411
Each GP5-411 is reguired for each CPU node. One GP5-SB101 is used for max.
4 CPU nodes.
Enhanced keyboard GP5-R1KB2
Keyboard/Monitor Shelf Kit GP5-R1TB5(for GP5­R2RC1/GP5-R1RC4)
A maximum of two servers can be installed in a, 40U Rack system.The Rack Coupling kit is used for connecting two Racks together.
40U Rack GP5-R1RC4
24U Rack GP5-R2RC1
Storage System GP5UR1DC4
RAID Card GP5U141
SCSI Card GP5-125
SCSI Card GP5-127
M800
Series
L800 G800 C800
Series
yy y
SCSI Cable GP5MU823A
SCSI Cable GP5MU829A
SCSI Cable GP5MU823A/GP5S-833/834
RAID Card GP5-144
yy y
SCSI Cable GP5S-832/835/836
RAID Card GP5-146
yy y
SCSI Cable GP5S-832/835/836
y
y
C800
Only
C800
Only
L/G 800
Only
L/G 800
Only
L/G 800
Only
HS900
Hard Disk Drive-36GB(10,000rpm)
GP5-HDH61
GP5U141 can be used for Hard disk cabinet only when GP5U142 is used to connect internal hard disk array.
21
teamserver Hardware
Product Product ID Remarks
teamserver HS900 (Rackmount) (End Nov 1999)
teamserver HS900 (Rackmount) (End Nov 1999)
teamserver M890ie (End Nov 1999)
teamserver M890ie
(Rackmount)
(End Nov 1999)
teamserver M880ie (End Nov 1999)
teamserver M880ie (Rackmount) (End Nov 1999)
teamserver L890ie (Mid Nov 1999)
teamserver L890ie (Rackmount) (Mid Nov 1999)
teamserver L880ie (Mid Nov 1999)
GP5T9A32R
GP5T9A22R
GP5M895AL
GP5M895BL
GP5M885AL
GP5M885BL
GP5L895L
GP5L895LR
GP5L885L
Pentium lll Xeon 550MHz with 2MB Cache (x2, up to 8CPUs) , 1GB (128MB SDRAM-DIMM x8) SDRAM-DIMM with ECC, ( 32GB maximum ) 32xCD-ROM, FDD, 2x Ultra2 Wide Onboard SCSI and 2ch LVD array controller card, 100Base­TX/10Base-T LAN Card 2Internal HDD bays (Ultra2wide SCSI/Hot plug), 64bit(66MHz)Hot-plug PCIx4, 64bit(33MHz)Hot­plug PCIx6, Wakeup on LAN Hot plug-Redundant PSU/Fan, Servervisor/LANDesk Server Manager, ServerWizard * Windows NT4.0 only supports up to 4CPUs and 4GB Memory, for more than that use Windows NT 4.0E.E
Pentium lll Xeon 550MHz with 1MB Cache (x2, up to 8CPUs) , 1GB (128MB SDRAM-DIMM x8) SDRAM-DIMM with ECC, ( 32GB maximum ) 32xCD-ROM, FDD, 2x Ultra2 Wide Onboard SCSI and 2ch LVD array controller card, 100Base­TX/10Base-T LAN Card 2Internal HDD bays (Ultra2wide SCSI/Hot plug), 64bit(66MHz)Hot-plug PCIx4, 64bit(33MHz)Hot­plug PCIx6, Wakeup on LAN Hot plug-Redundant PSU/Fan, Servervisor/LANDesk Server Manager, ServerWizard * Windows NT4.0 only supports up to 4CPUs and 4GB Memory, for more than that use Windows NT 4.0E.E
Pentium lll Xeon 550MHz with 2MB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 8GB maximum ) 32xCD-ROM, FDD, Fast narrow Onboard SCSI, 100Base-TX/10Base-T LAN Card 6Internal HDD bays (Ultra2wide SCSI/Hot plug) - 14bays maximum : Intl. HDD(6)+GP5UR1DC4,PCI64bitx5, PCI32bitx5, ISA/PCI32bitx1, Hot plug PSU, Hot plug Fan, Servervisor/LANDesk Server Manager, ServerWizard * Windows NT4.0 only supports up to 4CPUs and 4GB Memory, for more than that use Windows NT 4.0E.E
Pentium lll Xeon 550MHz with 2MB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 8GB maximum ) 32xCD-ROM, FDD, Fast narrow Onboard SCSI, 100Base-TX/10Base-T LAN Card 6Internal HDD bays (Ultra2wide SCSI/Hot plug) - 14bays maximum : Intl. HDD(6)+GP5UR1DC4,PCI64bitx5, PCI32bitx5, ISA/PCI32bitx1, Hot plug PSU, Hot plug Fan, Servervisor/LANDesk Server Manager, ServerWizard * Windows NT4.0 only supports up to 4CPUs and 4GB Memory, for more than that use Windows NT 4.0E.E
Pentium lll Xeon 550MHz with 1MB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 8GB maximum ) 32xCD-ROM, FDD, Fast narrow Onboard SCSI, 100Base-TX/10Base-T LAN Card 6Internal HDD bays (Ultra2wide SCSI/Hot plug) - 14bays maximum : Intl. HDD(6)+GP5UR1DC4,PCI64bitx5, PCI32bitx5, ISA/PCI32bitx1, Hot plug PSU, Hot plug Fan, Servervisor/LANDesk Server Manager, ServerWizard * Windows NT4.0 only supports up to 4CPUs and 4GB Memory, for more than that use Windows NT 4.0E.E
Pentium lll Xeon 550MHz with 1MB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 8GB maximum ) 32xCD-ROM, FDD, Fast narrow Onboard SCSI, 100Base-TX/10Base-T LAN Card 6Internal HDD bays (Ultra2wide SCSI/Hot plug) - 14bays maximum : Intl. HDD(6)+GP5UR1DC4,PCI64bitx5, PCI32bitx5, ISA/PCI32bitx1, Hot plug PSU, Hot plug Fan, Servervisor/LANDesk Server Manager, ServerWizard * Windows NT4.0 only supports up to 4CPUs and 4GB Memory, for more than that use Windows NT 4.0E.E
Pentium lll Xeon 550MHz with 2MB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 4GB maximum ) 24xCD-ROM,FDD, 2xUltra2 Wide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T LAN Card 8Internal HDD bays (Ultra2Wide SCSI/Hot plug), PCIx6, ISA/PCIx1, Wakeup on LAN Hot plug PSU,Hot plug Fan, Servervisor/LANDesk Server Manager, ServerWizard
Pentium lll Xeon 550MHz with 2MB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 4GB maximum ) 24xCD-ROM,FDD, 2xUltra2 Wide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T LAN Card 8Internal HDD bays (Ultra2Wide SCSI/Hot plug), PCIx6, ISA/PCIx1, Wakeup on LAN Hot plug PSU,Hot plug Fan, Servervisor/LANDesk Server Manager, ServerWizard
Pentium lll Xeon 550MHz with 1MB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 4GB maximum ) 24xCD-ROM,FDD, 2xUltra2 Wide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T LAN Card 8Internal HDD bays (Ultra2Wide SCSI/Hot plug), PCIx6, ISA/PCIx1, Wakeup on LAN Hot plug PSU,Hot plug Fan, Servervisor/LANDesk Server Manager, ServerWizard
22
teamserver Hardware
Product Product ID Remarks
teamserver L880ie (Rackmount) (Mid Nov 1999)
teamserver L870ie (Mid Nov 1999)
teamserver L870ie (Rackmount) (Mid Nov 1999)
teamserver G870ix (Mid Nov 1999)
teamserver G870ix
(Rackmount)
(Mid Nov 1999)
teamserver G870ie (Mid Nov 1999)
teamserver G870ie (Rackmount) (Mid Nov 1999)
teamserver G870i (Mid Nov 1999)
teamserver G870i (Rackmount) (Mid Nov 1999)
teamserver C870ix (Mid Nov 1999)
teamserver C870ix (Rackmount) (Mid Nov 1999)
GP5L885LR
GP5L875L
GP5L875LR
GP5G879L
GP5G879LR
GP5G878L
GP5G878LR
GP5G877L
GP5G877LR
GP5C876
GP5C876R
Pentium lll Xeon 550MHz with 1MB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 4GB maximum ) 24xCD-ROM,FDD, 2xUltra2 Wide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T 8Internal HDD bays (Ultra2Wide SCSI/Hot plug), PCIx6, ISA/PCIx1, Wakeup on LAN Hot plug PSU,Hot plug Fan, Servervisor/LANDesk Server Manager, ServerWizard
Pentium lll Xeon 550MHz with 512KB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 4GB maximum ) 24xCD-ROM,FDD, 2xUltra2 Wide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T 8Internal HDD bays (Ultra2Wide SCSI/Hot plug), PCIx6, ISA/PCIx1, Wakeup on LAN Hot plug PSU,Hot plug Fan, Servervisor/LANDesk Server Manager, ServerWizard
Pentium lll Xeon 550MHz with 512KB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 4GB maximum ) 24xCD-ROM,FDD, 2xUltra2 Wide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T 8Internal HDD bays (Ultra2Wide SCSI/Hot plug), PCIx6, ISA/PCIx1, Wakeup on LAN Hot plug PSU,Hot plug Fan, Servervisor/LANDesk Server Manager, ServerWizard
Pentium lll 600MHz with 512KB Cache (x1, up to 2CPUs) , 256MB SDRAM (Single DIMM with ECC,2GB maximum ) 32xCD-ROM, FDD, 2xUltra2 Wide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T Onboard LAN 8Internal HDD bays (Ultra2Wide SCSI/Hot plug), PCIx4, ISA/PCIx1, ISAx1, Hot plug PSU,Hot plug Fan, Wakeup on LAN, Servervisor/LANDesk Server Manager, ServerWizard
Pentium lll 600MHz with 512KB Cache (x1, up to 2CPUs) , 256MB SDRAM (Single DIMM with ECC,2GB maximum ) 32xCD-ROM, FDD, 2xUltra2 Wide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T Onboard LAN 8Internal HDD bays (Ultra2Wide SCSI/Hot plug) - 40bays maximum : Intl. HDD(8)+GP5UR1DC4x4, PCIx4, ISA/PCIx1, ISAx1 Hot plug PSU,Hot plug Fan, Wakeup on LAN, Servervisor/LANDesk Server Manager, ServerWizard
Pentium lll 550MHz with 512KB Cache (x1, up to 2CPUs) , 256MB SDRAM (Single DIMM with ECC,2GB maximum ) 32xCD-ROM, FDD, 2xUltra2 Wide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T Onboard LAN 8Internal HDD bays (Ultra2Wide SCSI/Hot plug), PCIx4, ISA/PCIx1, ISAx1, Hot plug PSU,Hot plug Fan, Wakeup on LAN, Servervisor/LANDesk Server Manager, ServerWizard
Pentium lll 550MHz with 512KB Cache (x1, up to 2CPUs) , 256MB SDRAM (Single DIMM with ECC,2GB maximum ) 32xCD-ROM, FDD, 2xUltra2 Wide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T Onboard LAN 8Internal HDD bays (Ultra2Wide SCSI/Hot plug) - 40bays maximum : Intl. HDD(8)+GP5UR1DC4x4, PCIx4, ISA/PCIx1, ISAx1 Hot plug PSU,Hot plug Fan, Wakeup on LAN, Servervisor/LANDesk Server Manager, ServerWizard
Pentium lll 500MHz with 512KB Cache (x1, up to 2CPUs) , 256MB SDRAM (Single DIMM with ECC,2GB maximum ) 32xCD-ROM, FDD, 2xUltra2 Wide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T Onboard LAN 8Internal HDD bays (Ultra2Wide SCSI/Hot plug), PCIx4, ISA/PCIx1, ISAx1, Hot plug PSU,Hot plug Fan, Wakeup on LAN, Servervisor/LANDesk Server Manager, ServerWizard
Pentium lll 500MHz with 512KB Cache (x1, up to 2CPUs) , 256MB SDRAM (Single DIMM with ECC,2GB maximum ) 32xCD-ROM, FDD, 2xUltra2 Wide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T Onboard LAN 8Internal HDD bays (Ultra2Wide SCSI/Hot plug) - 40bays maximum : Intl. HDD(8)+GP5UR1DC4x4, PCIx4, ISA/PCIx1, ISAx1 Hot plug PSU,Hot plug Fan, Wakeup on LAN, Servervisor/LANDesk Server Manager, ServerWizard
Pentium lll 600MHz with 512KB Cache (x1, up to 2CPUs) , 128MB SDRAM (Single DIMM with ECC,1GB maximum ) 32xCD-ROM, FDD, 1xUltrawide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T Onboard LAN 4Internal HDD bays (Ultra Wide SCSI/3xHot plug), PCIx3, ISAx2, Wakeup on LAN Servervisor/LANDesk Server Manager, ServerWizard
Pentium lll 600MHz with 512KB Cache (x1, up to 2CPUs) , 128MB SDRAM (Single DIMM with ECC,1GB maximum ) 32xCD-ROM, FDD, 1xUltrawide/1xFast narrow Onboard SCSI, 100Base-TX/10Base-T Onboard LAN 4Internal HDD bays (Ultra Wide SCSI/3xHot plug) - 36bays maximum : Intl. HDD(4)+GP5UR1DC4x4, PCIx3, ISAx2, Wakeup on LAN Servervisor/LANDesk Server Manager, ServerWizard
23
teamserver Hardware
Product Product ID Remarks
teamserver C870ie
teamserver C870ie (Rackmount)
teamserver C870i
teamserver C870i (Rackmount)
teamserver C850ie
teamserver C850ie (Rackmount)
teamserver C370ix (Mid Nov 1999)
teamserver C370ie (Mid Nov 1999)
teamserver C370i (Mid Nov 1999)
teamserver C350ie
GP5C875
GP5C875R
GP5C871
GP5C871R
GP5C855
GP5C855R
GP5C379
GP5C378
GP5C377
GP5C355
Pentium lll 550MHz with 512KB Cache (x1, up to 2CPUs) , 128MB SDRAM (Single DIMM with ECC,1GB maximum ) 32xCD-ROM, FDD, 1xUltrawide/1xFast narrow SCSI is on board, 100Base-TX/10Base-T Onboard LAN 4Internal HDD bays (Ultra Wide SCSI/3xHot plug), PCIx3, ISAx2, Wakeup on LAN Servervisor/LANDesk Server Manager, ServerWizard
Pentium lll 550MHz with 512KB Cache (x1, up to 2CPUs) , 128MB SDRAM (Single DIMM with ECC,1GB maximum ) 32xCD-ROM, FDD, 1xUltrawide/1xFast narrow SCSI is on board, 100Base-TX/10Base-T Onboard LAN 4Internal HDD bays (Ultra Wide SCSI/3xHot plug) - 36bays maximum : Intl. HDD(4)+GP5UR1DC4x4, PCIx3, ISAx2, Wakeup on LAN Servervisor/LANDesk Server Manager, ServerWizard
Pentium lll 500MHz with 512KB Cache (x1, up to 2CPUs) , 128MB SDRAM (Single DIMM with ECC,1GB maximum ) 32xCD-ROM, FDD, 1xUltrawide/1xFast narrow SCSI is on board, 100Base-TX/10Base-T Onboard LAN 4Internal HDD bays (Ultra Wide SCSI/3xHot plug), PCIx3, ISAx2, Wakeup on LAN Servervisor/LANDesk Server Manager, ServerWizard
Pentium lll 500MHz with 512KB Cache (x1, up to 2CPUs) , 128MB SDRAM (Single DIMM with ECC,1GB maximum ) 32xCD-ROM, FDD, 1xUltrawide/1xFast narrow SCSI is on board, 100Base-TX/10Base-T Onboard LAN 4Internal HDD bays (Ultra Wide SCSI/3xHot plug) - 36bays maximum : Intl. HDD(4)+GP5UR1DC4x4, PCIx3, ISAx2, Wakeup on LAN Servervisor/LANDesk Server Manager, ServerWizard
Pentium lll 450MHz with 512KB Cache (x1, up to 2CPUs) , 128MB SDRAM (Single DIMM with ECC,1GB maximum ) 32xCD-ROM, FDD, 1xUltrawide/1xFast narrow SCSI is on board, 100Base-TX/10Base-T Onboard LAN 4Internal HDD bays (Ultra Wide SCSI/3xHot plug), PCIx3, ISAx2, Wakeup on LAN Servervisor/LANDesk Server Manager, ServerWizard
Pentium lll 450MHz with 512KB Cache (x1, up to 2CPUs) , 128MB SDRAM (Single DIMM with ECC,1GB maximum ) 32xCD-ROM, FDD, 1xUltrawide/1xFast narrow SCSI is on board, 100Base-TX/10Base-T Onboard LAN 4Internal HDD bays (Ultra Wide SCSI/3xHot plug) - 36bays maximum : Intl. HDD(4)+GP5UR1DC4x4, PCIx3, ISAx2, Wakeup on LAN Servervisor/LANDesk Server Manager, ServerWizard
Pentium lll 600MHz with 512KB Cache (x1),128MB Unbuffered SDRAM (Single DIMM with ECC,768MB maximum) 32xCD-ROM, FDD, 100Base-TX/10Base-T PCIx4,ISAx1, 3(4:use 5"bay)Internal HDD bays (Ultra2 Wide SCSI /EIDE, non-Hot plug), Wakeup on LAN Servervisor/LANDesk Server Manager, ServerWizard
Pentium lll 550MHz with 512KB Cache (x1),128MB Unbuffered SDRAM (Single DIMM with ECC,768MB maximum) 32xCD-ROM, FDD, 100Base-TX/10Base-T PCIx4,ISAx1, 3(4:use 5"bay)Internal HDD bays (Ultra2 Wide SCSI /EIDE, non-Hot plug), Wakeup on LAN Servervisor/LANDesk Server Manager, ServerWizard
Pentium lll 500MHz with 512KB Cache (x1),128MB Unbuffered SDRAM (Single DIMM with ECC,768MB maximum) 32xCD-ROM, FDD, 100Base-TX/10Base-T PCIx4,ISAx1, 3(4:use 5"bay)Internal HDD bays (Ultra2 Wide SCSI /EIDE, non-Hot plug), Wakeup on LAN Servervisor/LANDesk Server Manager, ServerWizard
Pentium lll 450MHz with 512KB Cache (x1),64MB Unbuffered SDRAM (Single DIMM with ECC,768MB maximum) 32xCD-ROM, FDD, 100Base-TX/10Base-T PCIx4,ISAx1, 3(4:use 5"bay)Internal HDD bays (Ultra Wide SCSI /EIDE, non-Hot plug), Wakeup on LAN Servervisor/LANDesk Server Manager, ServerWizard
Product
Product ID (Overseas inc.Korea)
HS900 M800i
L800i G800i C800i C300i
24
teamserver Hardware
P-lll Xeon(550MHz)/32KB+2MBcachex1,Placed on motherboard Includes one CPU, For HS900
P-lll Xeon(550MHz)/32KB+1MBcachex1,Placed on motherboard Includes one CPU, For HS900
P-lll Xeon(550MHz)/32KB+2MBcachex1,Placed on motherboard Includes one CPU and dedicated power supply module (VRM)
P-lll Xeon(550MHz)/32KB+1MBcachex1,Placed on motherboard Includes one CPU and a dedicated power supply module (VRM)
P-lll Xeon(550MHz)/32KB+512KBcachex1,Placed on motherboard Includes one CPU and a dedicated power supply module (VRM)
P-lll(600MHz)/32KB+512KB, for G870ix/C870ix Do not mix with other processor speed
P-lll(550MHz)/32KB+512KB, for G870ie/C870ie Do not mix with other processor speed
P-lll(500MHz)/32KB+512KBx1, for G870i/C870i Do not mix with other processor speed
P-lll(450MHz)/32KB+512KBx1, for G850ie/C850ie Do not mix with other processor speed
SDRAM-DIMM 1024MBx2 (Registered 100MHz)
SDRAM-DIMM 512MBx2 (Registered 100MHz)
SDRAM-DIMM 256MBx2 (Registered 100MHz)
SDRAM-DIMM 128MBx2 (Registered 100MHz)
Additional memory board for mounting more than 16GB memory
EDO-DIMM(Buffered;50ns)256MBx4
EDO-DIMM(Buffered;50ns)128MBx4
EDO-DIMM(Buffered;50ns)64MBx4
EDO-DIMM(Buffered;50ns)32MBx4
SDRAM-DIMM 512MBx1 (Registered 100MHz)
SDRAM-DIMM 256MBx1 (Registered 100MHz)
SDRAM-DIMM 128MBx1 (Registered 100MHz)
SDRAM-DIMM 64MBx1 (Registered 100MHz)
Unbuffered SDRAM-DIMM 256MBx1
Unbuffered SDRAM-DIMM 128MBx1
Unbuffered SDRAM-DIMM 64MBx1
36.4GB,Ultra2wide SCSI,10000rpm,SCA2 80pin(SE),Hotplug for HS900
18.2GB,Ultra2wide SCSI,10000rpm,SCA2 80pin(SE),Hotplug for HS900
9.1GB,Ultra2wide SCSI,10000rpm,SCA2 80pin(SE),Hotplug for HS900
36.4GB,Ultra2wide SCSI,10000rpm,SCA2 80pin(SE),Hotplug for M8xxi,L8xxi, Storage System(GP5UR1DC4), Hard Disk Cabinet(GP5MS622A)
18.2GB,Ultra2wide SCSI,10000rpm,SCA2 80pin(SE),Hotplug for M8xxi,L8xxi, Storage System(GP5UR1DC4), Hard Disk Cabinet(GP5MS622A)
9.1GB,Ultra2wide SCSI,10000rpm,SCA2 80pin(SE),Hotplug for M8xxi,L8xxi, Storage System(GP5UR1DC4), Hard Disk Cabinet(GP5MS622A)
18.2GB,Ultra2wide SCSI,7200rpm,SCA2 80pin(SE),Hotplug for M8xxi,L8xxi, Storage System(GP5UR1DC4), Hard Disk Cabinet(GP5MS622A)
9.1GB,Ultra2wide SCSI,7200rpm,SCA2 80pin(SE),Hotplug for M8xxi,L8xxi, Storage System(GP5UR1DC4), Hard Disk Cabinet(GP5MS622A)
GP5-FG203T
GP5-FG202T
GP5-FG203
GP5-FG202
GP5-FG201
GP5-FG10Y
GP5-FG10V
GP5-FG10N
GP5-FG10W
GP5-RM2J
GP5-RM1J
GP5-RM51J
GP5-RM25J
GP5-RB201
GP5-RM1G
GP5-RM51G
GP5-RM25G
GP5-RM12G
GP5-RM51F
GP5-RM25F
GP5-RM12F
GP5-RM64F
GP5-RM25H
GP5-RM12H
GP5-RM64H
GP5-HDH61T
GP5-HDH85T
GP5-HDH98T
GP5-HDH61
GP5-HDH85
GP5-HDH98
GP5-HDH84
GP5-HDH97
CPU Field Upgrade Kit
CPU Field Upgrade Kit
CPU Field Upgrade Kit
CPU Field Upgrade Kit
CPU Field Upgrade Kit
CPU Field Upgrade Kit
CPU Field Upgrade Kit
CPU Field Upgrade Kit
CPU Field Upgrade Kit
Additional Memory 2GB (End Feb 00)
Additional Memory 1GB (End Jan 00)
Additional Memory 512MB (End Jan 00)
Additional Memory 256MB
Additional Memory Board
Additional Memory 1GB
Additional Memory 512MB
Additional Memory 256MB
Additional Memory 128MB
Additional Memory 512MB
Additional Memory 256MB
Additional Memory 128MB
Additional Memory 64MB
Additional Memory 256MB
Additional Memory 128MB
Additional Memory 64MB
Hard Disk Drive-36GB
Hard Disk Drive-18GB
Hard Disk Drive-9GB
Hard Disk Drive-36GB
Hard Disk Drive-18GB
Hard Disk Drive-9GB
Hard Disk Drive-18GB
Hard Disk Drive-9GB
Remarks
GP5T9A32R
GP5T9A22R
GP5M895L
GP5M885L
GP5L895L
GP5L885L
GP5L875L
GP5G879L
GP5G878L
GP5G877L
GP5C876
GP5C875
GP5C871
GP5C855
GP5C379
GP5C378
GP5C377
GP5C355
■■
■■
■■
■■
■■
■■
■■
■■
■■
■■
■■■■■
■■■■■
■■■■■
■■■
■■■
■■■■■■■
■■■■■■■
■■■■■■■
■■■■
■■■■
■■■■
■■
■■
■■
■■■■■
■■■■■
■■■■■
■■■■■
■■■■■
25
teamserver Hardware
Product
Product ID (Overseas inc.Korea)
HS900 M800i
L800i G800i C800i C300i
18.2GB,Ultra2wide SCSI,7200rpm,SCA2 80pin(SE),Hotplug, For G8xxi,C8xxi
9.1GB,Ultra2wide SCSI,7200rpm,SCA2 80pin(SE),Hotplug, For G8xxi, C8xxi
9.1GB,Ultra Wide SCSI,7200rpm,SCA2 80pin(SE),Hotplug, Additional disk for GP5C800-875
4.3GB,Ultra2 Wide SCSI,7200rpm,SCA2 80pin(SE),Hotplug Additional disk for GP5C800-875/GP5G810-876L
4.3GB,Ultra Wide SCSI,7200rpm,SCA2 80pin(SE),Hotplug, Additonal disk for GP5C800-875
18.2GB,Ultra2 Wide SCSI,7200rpm,SE,68pin, Non Hotplug for C8xxi(Mounted in Non Hotplug bay), C3xxi(Mounted in Non Hotplug 3.5"Bay)
9.1GB,Ultra2 Wide SCSI,7200rpm,SE,68pin, Non Hotplug for C8xxi(Mounted in Non Hotplug bay), C3xxi(Mounted in Non Hotplug 3.5"Bay)
9.1GB,Ultra Wide SCSI,7200rpm,SE,68pin, Non Hotplug Additional disk for GP5C300-375/GP5C800-C875
4.3GB,Ultra2 Wide SCSI,7200rpm,SE,68pin, Non Hotplug Additional disk for GP5C300-375/GP5C800-C875
4.3GB,Ultra Wide SCSI,7200rpm,SE,68pin, Non Hotplug Additional disk for GP5C300-375/GP5C800-C875
18.2GB,Ultra2 Wide SCSI,7200rpm,SE,68pin, Non Hotplug for mounting in 5"bay of C3xxi
9.1GB,Ultra2 Wide SCSI,7200rpm,SE,68pin, Non Hotplug for mounting in 5"bay of C3xxi
4.3GB,Ultra2 Wide SCSI,7200rpm,SE,68pin, Non Hotplug Additional disk for mounting in 5"bay of GP5C300-C375
EIDE,5400rpm, 13GB, for C3xxi
DDS-3 (12-24GB) Helical scan device back up 12GB (24GB average when compressed) Effective transfer speed is 1MB/s (not compressed)When connecting to C300i, SCSI Card (GP5-125,126/127) and SCSI Cable (GP5­841/840) is required, Please order cartridge and cleaning cartridge separately.
SLR-5 (4-8GB) Single-channel linear recording system, 4GB (8GB average when compressed) Effective transfer speed is 380KB/s (not compressed)Data format: QIC-4GB, QIC-2GB, When connecting to C300i, SCSI Card (GP5­125,126/127) and SCSI Cable (GP5-841/840) is required, Please order cartridge and cleaning cartridge separately.
DLT4000SE narrow (20-40GB) Linear scan device back up 20GB (40GB average when compressed) high-speed transfer up to 1.5MB/s (not compressed)Shipped with one data cartridge and one cleaning cartridge.
DLT7000SE wide (35-70GB) Linear scan device back up 35GB (70GB average when compressed) high-speed transfer up to 5.0MB/s (not compressed)Shipped with one data cartridge, one cleaning cartridge and one internal SCSI Cable (with terminal resistor added). Two 5"bays are required and occupied. When mounting for G800i, additional PSU is required
MLR-3 (20-40GB) Multi-channel linear recording system, 25GB (50GB average when compressed) and high-speed transfer - up to 2.0MB/s (not compressed)Data format: MLR3-25GB, SCSI Card is required to connect(Please refer to PXX), Shipped with one data cartridge and one cleaning cartridge.
TRAVAN NS-20 (10-20GB) Linear scan device back up 10GB (20GB average when compressed) and high-speed transfer - up to 1.0MB/s, Data format:QIC­3220-MC, When connecting to C300i, SCSI Card (GP5-125,126/127) and SCSI Cable (GP5-841/840) is required, Shipped with one data cartridge and one cleaning cartridge.
5" bay node for Rackmount (3U) Up to four Tape units can be mounted, GP5UDL351/GP5-DL201/GP5UDT301/GP5USL501/GP5-ML301/GP5-NS201 are available, Redundant PSU (Opt.), SCSI Cable (GP5U832, GP5S823) is required
Redundant PSU (450W)
Redundant PSU (350W)
GP5-HDH83
GP5-HDH96
GP5-HDH92
GP5-HDH461
GP5-HDH44
GP5-HD8G1
GP5-HD9G3
GP5-HD9G2
GP5-HD4G51
GP5-HD4G5
GP5-HD8G1B
GP5-HD9G3B
GP5-HD4G5B
GP5-HD3E1
GP5UDT301
GP5USL501
GP5UDL201
GP5-DL351
GP5-ML301
GP5-NS201
GP5UR1BC1
GP5UPU131
GP5UPU141
Hard Disk Drive-18GB
Hard Disk Drive-9GB
Hard Disk Drive-9GB
Hard Disk Drive-4GB
Hard Disk Drive-4GB
Hard Disk Drive-18GB
Hard Disk Drive-9GB
Hard Disk Drive-9GB
Hard Disk Drive-4GB
Hard Disk Drive-4GB
Hard Disk Drive-18GB
Hard Disk Drive-9GB
Hard Disk Drive-4GB
Hard Disk Drive-13GB
DAT unit (DDS-3)
Tape unit (SLR5)
DLT unit
DLT unit
Tape unit (MLR-3)
TRAVAN NS unit (NS-20)
Backup Cabinet
Redundant Power Supply Unit
Redundant Power Supply Unit
Remarks
GP5T9A32R
GP5T9A22R
GP5M895L
GP5M885L
GP5L895L
GP5L885L
GP5L875L
GP5G879L
GP5G878L
GP5G877L
GP5C876
GP5C875
GP5C871
GP5C855
GP5C379
GP5C378
GP5C377
GP5C355
■■■■■■■
■■■■■■■
■■■■■■■■
■■■■■■■■
■■
■■
■■
■■■■
■■■■
■■■■
■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■
■■■■■■■■■■
■■■■■■■■■■
■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■
■■
■■■■■■
■■
26
teamserver Hardware
Product
Product ID (Overseas inc.Korea)
HS900 M800i
L800i G800i C800i C300i
Redundant PSU (300W), For Backup Cabinet (GP5UR1BC1)
Redundant PSU for GP5UR1DC4/GP5MS622A (350W)
Rackmount pattern instruction
19'' 40U Locker , Front door,rear door,side panel,earthquake proof board , blank panel is attached. Size(WxDxH)mm:600x900x2000 <Number of units required for installation> C8xxi:6U, G8xxi:7U, L8xxi:7U, M8xxi/ic:10U GP5UR1DC4: 4U Keyboard/Monitor Shelf: 9U(for installation 15''CRT),1U(for installation Keyboard) Component shelf: 5U CRT/KB switch: Mounted at side of CRT (occupies same U as CRT)
19''40U Locker + connection metal fittings Front door,rear door,concatenation frame,blank panel is attached.
19'' 24U Locker , Front door,rear door,side panel,earthquake proof board , blank panel is attached. Size(WxDxH)mm:600x900x1200 <Number of units required for installation> C8xxi:6U, G8xxi:7U, L8xxi:7U, M8xxi/ic:10U GP5UR1DC4: 4U Keyboard/Monitor Shelf: 9U(for installation 15''CRT),1U(for installation Keyboard) Component shelf: 5U CRT/KB switch: Mounted at side of CRT (occupies same U as CRT)
19''24U Locker + connection metal fittings Front door,rear door,concatenation frame,blank panel is attached.
Shelf to fit peripheral device into 40U Rack, Table size:400(W)x500(D)
For New Rack (as of Jul 1999: GP5-R2RC1/GP5-R1DC4) Used to store display unit (CRT), a keyboard (KB), and a mouse on a rack.
Switch enables sharing of a set of CRT,keyboard,and mouse by two or more servers (up to four servers).
CRT/KB cable , CRT cablex1,KB/Mouse cablex1 is attached
87Key keyboard for Rackmountable type
Hard Disk Node LVD/SE for Rack (4U) 8 Hot plug HDD Bays (up to 291.2GB:
36.4GBx8) Support Ultra2 Wide SCSI/Ultra Wide SCSI, Redundant FAN(Up to two Std.)/PSU(A GP5UR1PU1is standard equipment, up to two)
Hard Disk Cabinet LVD/SE for Pedestal 8 Hot plug HDD Bays (up to 291.2GB:
36.4GBx8) Support Ultra2 Wide SCSI/Ultra Wide SCSI, Redundant FAN(Up to two Std.)/PSU(A GP5UR1PU1is standard equipment, up to two)
Ultrawide, differential-end, x1ch, SMART not supported, Up to 40MB/s of syncronous transfer support Connector: half-pitch 68pin for external SCSI device, half-pitch 50/68pin for internal SCSI device For connection with Disk Array devices * SCSI cable is required.
Ultrawide, SE, x1ch, SMART supported, Up to 40MB/s of syncronous transfer support Connector: half-pitch 68pin for external SCSI device, half-pitch 50/68pin for internal SCSI device. For connection with internal and external SCSI devices *SCSI cable is required.
Ultra2 Wide, LVD, x1ch, SMART supported, Up to 80MB/s of syncronous transfer support Connector: half-pitch 68pin and half-pitch 50/68pin. *SCSI cable is required
Ultra2 Wide, LVD, x1ch, SMART supported, Up to 80MB/s of syncronous transfer support Connector: half-pitch 68pin for external SCSI device, half-pitch 50/68pin for internal SCSI device. For connection with internal OR external SCSI devices *SCSI cable is required
Raid card, Ultrawide SCSI, SE, x2ch, 16MB cache, RAID level 0,1,5 are supported For internal/external array configuration *SCSI cable(for array configuration use) is required
Raid card, Ultrawide SCSI, SE, x2ch, 4MB cache, RAID level 0,1,5 are supported For internal array configuration *SCSI cable(for array configuration use) is required
Raid card, Ultrawide SCSI, x2ch, 8MB cache, RAID level 0,1,5,6 are supported For internal array configuration *SCSI cable(for array configuration use) is required
GP5UPU151
GP5UR1PU1
GP5RMP
GP5-R1RC4
GP5-R1RC5
GP5-R2RC1
GP5-R2RC2
GP5-R1TB4
GP5-R1TB5
GP5-SB101
GP5-411
GP5-R1KB2
GP5UR1DC4
GP5MS622A
GP5-123
GP5-125
GP5-126
GP5-127
GP5U141
GP5U142
GP5-143
Redundant Power Supply Unit
Redundant Power Supply Unit
Rackmount Pattern
40U Rack
40U Rack&Rack Coupling Kit
24U Rack
24U Rack&Rack Coupling Kit
Component Shelf
Keyboard/Monitor Shelf Kit
Keyboard/Monitor Enhanced Switch
Keyboard/Monitor Extension Cables
Enhanced Keyboard
Storage System
Hard Disk Cabinet
SCSI Card
SCSI Card
SCSI Card
SCSI Card
RAID Card
RAID Card
RAID Card
Remarks
GP5T9A32R
GP5T9A22R
GP5M895L
GP5M885L
GP5L895L
GP5L885L
GP5L875L
GP5G879L
GP5G878L
GP5G877L
GP5C876
GP5C875
GP5C871
GP5C855
GP5C379
GP5C378
GP5C377
GP5C355
■■
■■
R/P
R/PR/PR/PR/PR/PR/PR/PR/PR/PR/PR/P
■■■■
RRRRRRRRRRRRRR
■■RRRRRRRRRRRR
■■RRRRRRRRRRRR
■■RRRRRRRRRRRR
■■RRRRRRRRRRRR
■■RRRRRRRRRRRR
■■RRRRRRRRRRRR
■■RRRRRRRRRRRR
■■RRRRRRRRRRRR
■■RRRRRRRRRRRR
■■RRRRRRRRRRRR
PPPPPPPPPPPP■■■■
■■■■■■■■■■
■■■■
■■■
■■■■■■■■■■ ■■■
■■■■■■■
■■■
■■■■■■■■
P : Pedestal, R : Rack
27
teamserver Hardware
Product
Product ID (Overseas inc.Korea)
HS900 M800i
L800i G800i C800i C300i
Raid card, Ultra2 Wide SCSI, LVD, x3ch, 32MB cache, Battery Backup, RAID level 0,1,5,6 are supported For internal/external array configuration *SCSI cable(for array configuration use) is required
Raid card, Ultra2 Wide SCSI, LVD, x2ch, 16MB cache, Battery Backup, RAID level 0,1,5,6 are supported For internal/external array configuration *SCSI cable(for array configuration use) is required
Connection internal devices (0.7m) for C8xxi
Ultra Wide SCSI cable(68pin), Internal SCSI HDD connection with GP5U141in C3xxi
Ultra2 Wide SCSI cable (68pin), Internal SCSI HDD connection in GP5C377-379
Internal narrow SCSI cable for 5'' Bay (50pin) for GP5-127 in GP5C377-379
Internal narrow SCSI cable for 5'' Bay (50pin) for GP5-125/126 in C3xxi
For connection GP5-144/146 to GP5UR1DC4/GP5MS622A (3m)
For connection GP5-127 to GP5UR1DC4 (5m), Only for Rackmount
For connection GP5-127 to GP5UR1DC4(10m), Only for Rackmount
For connection GP5-144/146 to GP5UR1DC4(5m), Only for Rackmount
For connection GP5-144/146 to GP5UR1DC4(10m), Only for Rackmount
SCSI-3(68pin)-SCSI-4(68pin), For connecting GP5-125/127 to GP5MS622A,GP5UR1DC4 (3.0m)
For connection between GP5U141 and GP5MS622A/GP5U141 to GP5UR1DC4 (2.0m)
SCSI Cable half68pin-Full50pin (1.0m)
SCSI Cable half68pin-half50pin (1.0m)
SCSI Cable half50pin-full50pin (1.0m)
Fibre Channel Card (3m) : For FC Card (GP5-FC101)/Giga LAN Card (GP5-183)
Fibre Channel Card (5m) : For FC Card (GP5-FC101)/Giga LAN Card (GP5-183)
Fibre Channel Card (15m) : For FC Card (GP5-FC101)/Giga LAN Card (GP5-
183)
High-transfer speed of up to 100MB/s, Long transfer distance of up to 500m, PCI-bus, driver is included, Fibre Channel cable is required
1000BASE-SX, PCI-bus, driver is included Fibre Channel cable is required : GP5-311/2m, GP5-312/5m, GP5-313/15m
100BASE-TX/10BASE-T, PCI-bus, driver is included, Twisted pair cable (category 5:100BASE-TX/category 3:10BASE-T) is required
Remote Console Interface Card, For Pedestal type of L800, Standard equipment of L800series Rackmount
Server Monitor Module has its own CPU,LAN,and power supply (AC adapter: option-procured locally). External Interface:10BASE-T RJ45 / RS232C D-sub 9pin, AC adapter:16V(DC) * Modem-only operation is impossible.
Server Monitor Module has its own CPU,LAN,and power supply (AC adapter: option-procured locally). External Interface:10BASE-T RJ45 / RS232C D-sub 9pin, AC adapter:16V(DC), For HS900 * Modem-only operation is impossible.
GP5-144
GP5-146
GP5U831
GP5-837
GP5-839
GP5-840
GP5-841
GP5S-832
GP5S-833
GP5S-834
GP5S-835
GP5S-836
GP5MU823A
GP5MU829A
GP5U832
GP5U833
GP5U834
GP5-311
GP5-312
GP5-313
GP5-FC101
GP5-183
GP5-185
GP5-RC101
GP5USM102
GP5USM103
RAID Card
RAID Card
SCSI Cable
SCSI Cable
SCSI Cable
SCSI Cable
SCSI Cable
SCSI Cable
SCSI Cable
SCSI Cable
SCSI Cable
SCSI Cable
SCSI Cable
SCSI Cable
SCSI Cable
SCSI Cable
SCSI Cable
Fibre Channel Cable
Fibre Channel Cable
Fibre Channel Cable
Fibre Channel Card
LAN Card (1000Base-SX)
LAN Card
RCI Card
Server Monitor Module
Server Monitor Module
Remarks
GP5T9A32R
GP5T9A22R
GP5M895L
GP5M885L
GP5L895L
GP5L885L
GP5L875L
GP5G879L
GP5G878L
GP5G877L
GP5C876
GP5C875
GP5C871
GP5C855
GP5C379
GP5C378
GP5C377
GP5C355
■■■■■■■■■■
■■■■■■■■■■
■■■■
■■■■
■■■
■■■
■■■■
■■■■■■■■■■
■■■■■■■■■■■■■■
■■■■■■■■■■■■■■
■■■■■■■■■■■■■■
■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■
■■■■■■■■■■■■■■
■■■■■■■■■■■■■■
■■■■■■■■■■
■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■
■■■
■■■■■■■■■■■■■■■■
■■
Specifications are subject to change without notice. For the latest detailed information, contact your local representative. All brand names and product names are trademarks and registered trademarks of their respective holders.
C
1999 Fujitsu Limited. All rights reserved. Printed in Japan. Six Edition November 1999
FUJITSU LIMITED
Business Development & Marketing Division Marketing Group
Marunouchi Center Building 6-1, Marunouchi 1-chome, Chiyoda-ku, Tokyo 100-8211, Japan Phone: +81-3-3215-5255 Fax: +81-3-3215-5259
URL http://www.fujitsu.co.jp/index-e.html
BK0065-6NS
Loading...