High Safety Required Use
This Product is designed, developed and manufactured as contemplated for general use,
including without limitation, general office use, personal use, household use, and ordinary
industrial use, but is not designed, developed and manufactured as contemplated for use accompanying fatal risks or dangers that, unless extremely high safety is secured, could lead
directly to death, personal injury, severe physical damage or other loss (hereinafter "High Safety
Required Use"), including without limitation, reaction core control in nuclear power facilities, aircraft autopilot flight control, air traffic control, operation control in mass transport control
systems, medical instruments for life support systems, missile launching control in weapon
systems. You shall not use this Product without securing the sufficient safety required for the High Safety Required Use. If you wish to use this Product for High Safety Required Use, please
consult with our sales person representatives in charge before such use.
Names and product names are the registered trademarks or trademarks of their respective
companies.
All Rights Reserved, Copyright© FUJITSU COMPONENT LIMITED 2012
Table of Contents
High Safety Required Use
1. PREFACE..........................................................................................................................................................1
2. CONVENTIONS ................................................................................................................................................1
3. CONFIRMING PACKAGE CONTENTS............................................................................................................2
4. IMPORTANT NOTICES ....................................................................................................................................2
5. SAFETY.............................................................................................................................................................3
6. NOTE WHEN USING A CASCADE CONNECTION ........................................................................................3
7. FEATURES .......................................................................................................................................................4
8. COMPONENTS.................................................................................................................................................5
9. INSTALLATION ..............................................................................................................................................13
10. CABLE CONNECTION AND REMOVAL.....................................................................................................16
10-1. Cable Connection.................................................................................................................. 16
10-2. Power Cord Clamp................................................................................................................ 20
10-3. Cable Removal...................................................................................................................... 22
11. KVM SWITCH OPERATION.........................................................................................................................23
11-1. Customer Mode Settings....................................................................................................... 23
11-2. Server Selection.................................................................................................................... 28
11-3. Constant Server name display on the OSD .......................................................................... 41
11-4. Small Window OSD (Upper Left Screen) .............................................................................. 42
11-5. Supplying Power to a KVM Switch........................................................................................ 43
11-6. Port 1 Fixed Mode Setting .................................................................................................... 43
12. SPECIFICATIONS.........................................................................................................................................44
APPENDIX. SERVER NAME RECORD SHEET................................................................................................50
1. Preface
FUJITSU COMPONENT would like to thank you for your purchase of a 4 Port KVM Switch, an 8 Port KVM Switch, or a 16 Port KVM Switch (hereinafter referred to as a "KVM Switch" or "this device"). Using this device enables multiple servers to be operated from a single monitor, keyboard, and mouse, greatly reducing your workspace area. In addition, if this device is used in a cascade connection, up to 256 servers can be operated by using 17 KVM Switches (16 port type). This manual explains basic operation of KVM Switches. Before using this device, make sure to carefully read the contents of this manual to ensure that this device is used correctly. After reading, store this manual in a safe place for easy reference when using this device.
2. Conventions
The symbols and terminology that are used in this manual are described below.
Ignoring this symbol and handling the device incorrectly may result in physical damage (to this device, the server, etc.) or physical injury.
Caution
Point This symbol indicates supplemental information, comments or hints.
Brackets [ ] KVM Switch or this device
<> Indicates keys on the keyboard
Numbers enclosed by brackets Indicates the required order of operations.
References important chapter titles and terminology Used as a common term for 4 port, 8 port, and 16 port switches in explanations
Example: <ESC> indicates the ESC key and <ENTER>
indicates the ENTER key
1
3. Confirming Package Contents
Check whether the following items were included in the shipping package by using check marks ( ) in the checkboxes below.
4 Port (FS-1104AU / FS-1104MU)
4 Port KVM Switch ×1 User's Manual (this manual) ×1 AC Adapter ×1 AC Cable [1m] ×1 Power Cord Clamp ×1
8 Port (FS-1108AU / FS-1108MU)
8 Port KVM Switch ×1 User's Manual (this manual) ×1 AC Cable [2m] ×1 Power Cord Clamp ×1 Wire Fixer ×1 Rack Fixing Bracket (Large) ×2 Rack Fixing Bracket (Small) ×2 Rack Fixing Bracket Screw ×10
16 Port (FS-1116AU / FS-1116MU)
16 Port KVM Switch ×1 User's Manual (this manual) ×1 AC Cable [2m] ×1 Power Cord Clamp ×1 Wire Fixer ×1 Rack Fixing Bracket (Large) ×2 Rack Fixing Bracket (Small) ×2 Rack Fixing Bracket Screw ×10
If something is missing from the package, contact your FUJITSU COMPONENT sales representative.
4. Important Notices
Chapters 5 and 6 contain cautions that must be taken when operating a KVM Switch and information related to safety. Carefully read these chapters to use a KVM Switch correctly.
2
5. Safety
Safety Precautions
Caution
This device adheres to the safety regulations related to information processing equipment such as electronic office machines that are used in an office environment. If you have any questions please contact your FUJITSU COMPONENT sales representative.
To prevent extreme bumping or shaking when moving a KVM Switch, use the original shipping container or a box similar to it.
During installation and before using a KVM Switch, carefully read [9. Installation] and the section about environmental conditions in [12.Specifications] to use the KVM Switch correctly.
Take power from a power outlet that constantly provides power without being interrupted by switches.
Moving a KVM Switch from a cold environment to the installation location may cause condensation to occur. Before using a KVM Switch, allow it to dry out completely and to reach the ambient temperature of the installation location.
Lay cables in an area where they will not become damaged. Refer to the relevant sections in [10. Cable connection and removal] when plugging or unplugging the cables.
Do not connect or remove cables during thunderstorms.
Do not allow foreign substances (such as necklaces and clips) or liquids inside KVM Switches.
In an emergency (device or parts failure: damage caused by liquid or foreign objects in the KVM
Switch), remove all cables from the KVM Switch as soon as possible and contact your FUJITSU COMPONENT sales representative.
Only licensed engineers can repair a KVM Switch. Any unlicensed user that opens a KVM Switch and makes incorrect repairs may cause electric shock or fire.
Always hold the connector portion and do not jerk the cables when removing them.
Avoid operating a KVM Switch or unplugging connectors with wet hands.
Do not place any unnecessary items (such as a cup) on top of a KVM Switch.
Only licensed personal can uncouple, remove, or replace parts (such as electro-magnetic wave
devices) which bear a warning mark (such as a lightning bolt).
To prevent interference, it is necessary to adequately isolate the data cables that are connected to peripheral equipment.
Keep this manual with the KVM Switch. If you give the KVM Switch to a third party, also give them this manual.
6. Note When Using a Cascade Connection
Using a cascade connection with previous KVM Switch models
For cascade connections with previous KVM Switch models, even though a cascade connection is possible by using the previous KVM Switch model as the master or slave side, restrictions may apply to functions with some models.
3
7. Features
Using a KVM Switch enables multiple PC servers to be operated by eliminating the need for multiple consoles (monitor, keyboard, and mouse) and making the use of multiple PC servers possible from a single console, greatly reducing the workspace area.
The maximum number of servers that can be selected for KVM Switches is four for the 4 port type, eight for the 8 port type, and 16 for the 16 port type.
The number of connectable servers can be increased by using a cascade connection.
Example: 256 servers can be connected with 17 KVM Switches (16 port type).
WUXGA (1920×1200) and a refresh rate of 60Hz is supported for the resolution of the monitor.
Servers can be easily selected by using the keyboard and mouse (Hotkey mode).
In the Hotkey mode, the server can be changed on the On Screen Display (hereinafter referred to
as OSD) as the screen is being watched.
For the OSD, hot keys can be input from the keyboard and mouse. Selection and settings can be performed by using three types of hot keys (<Ctrl> + <Alt> + <Shift>, <Ctrl> x2, <Scroll Lock> x2) or by clicking the central button of the mouse with a wheel button.
AutoScan is performed by the front switch or by the keyboard.
Because AutoScan automatically changes running servers, the status of each server can be
monitored at a constant cycle. In addition, six levels can be set for the frequency of changing.
A PC that has a USB port or a PS/2 port for keyboard and mouse interfaces can be connected to servers by using dedicated server/PC connection cables (refer to the items in the optional products section of [12.Specifications]).
The FS-11XXMU supports ORACLE (SUN) servers.
4
8. Components
Front panel view
5
Rear view
Rear view of the 4 Port KVM Switch
Rear view of the 8 Port KVM Switch
Rear view of the 16 Port KVM Switch
6
(1) LED
LEDs indicate states such as the server power status and the selected status.
When a cascade connection is not used
Server power
ON
ON
OFF
OFF
Port selection status
Selection is being performed
Not selected
Selection is being performed
Not selected
When a cascade connection is used
1: Master side
Slave KVM
Switch connection
Port selection status
Yes Selection is being performed
Yes Not selected
No
Selection is being performed
(server is also not
connected)
No
Not selected (server is also not
connected)
2: Slave side
Server power
Master side
Port selection status
ON
Slave side selection
is being performed
ON
OFF
OFF
ON
OFF
The slave side is not
selected, or another
slave is being
selected
Master side
Slave side
Port selection status
Selection is being
performed
Not selected
Selection is being performed
Not selected
LED display
Blue light
Green light
Blue light
Off
LED display
Orange light
Green light
Blue light
Off
LED display
Blue light
Green light
Blue light
Off
- Green light
- Off
7
3: For other cases
No AC power supply for the KVM Switch
(unplugged from power outlet, etc)
When the HOTKEY
mode is used
When the [RESET]
switch is pressed
When the [RESET] switch is pressed for a long time (5 seconds or more)
Status
When ports that are not
used for the cascade connection are being
selected
When ports that are used
for the cascade connection are being selected
When ports that are not
used for the cascade
connection are being selected
When ports that are used
for the cascade connection
are being selected
LED display
Blinking green light for all ports
(at intervals of 40ms)
Blinking blue light
(at intervals of 400ms)
Blinking orange light
(at intervals of 400ms)
Blinking blue light
(approx. 1 time)
Blinking orange light
(approx. 1 time)
AU: Fades-in/fades-out in green MU: Fades-in/fades-out in blue
When AutoScan is
performed
When ports that are not
used for the cascade
Blinking blue light
(Timing 1) connection are being
selected
When ports that are
used for the cascade
Blinking orange light
(Timing 1) connection are being
selected
Supported language when performing simple
settings for the keyboard type (using one port from ports 1-4)
Blinking blue light
(at intervals of 400ms)
(Timing 1)
8
(2) [ServerSelection] switch
Pushing the [ServerSelection] switch selects a server. Ports can also be selected when
the power status of the server is OFF.
(3) [AutoScan] switch
Pressing the [AutoScan] switch starts the AutoScan mode. In the AutoScan mode, the
screen of servers with ports for which the power is ON can be changed automatically in order.
Refer to "11-2-5. AutoScan Mode" for more details.
(4) [RESET] switch
This switch is not used for normal operations. Use the [RESET] switch when servers
cannot be selected or input errors occur with the mouse and keyboard by pressing the [RESET] switch lightly with the tip of a pen or similar object.
Pressing the [RESET] switch resets the microcomputer in the KVM Switch.
After resetting, the restoration process does not affect server operation because the PS/2 keyboard and PS/2 mouse are restarted with their modes maintained.
The USB keyboard and the USB mouse are disconnected for a one second interval.
This disconnection operation is used to restore USB operation.
For level 1
connection
For
cascade connection
When the [RESET] switch is
pressed for a short time (within 5 seconds)
The USB disconnection process is
performed for the selected ports
and consoles.
The USB disconnection process is
performed for the selected ports and consoles when the [RESET]
switch on the master side is
operated. In addition, the recognition process
of the cascade connection is tried
again.
The USB disconnection process is
performed for the selected ports on the slave side when the
[RESET] switch on the slave side
is operated.
When the [RESET] switch is
pressed for a long time (5 seconds or more)
The USB disconnection process
is performed for all of the ports
and consoles. The mode becomes the POWER
SUPPLY: ALWAYS ON mode.
The USB disconnection process
is performed for all of the ports and consoles on the slave and
master side when the [RESET]
switch on the master side is operated.
In addition, the mode becomes
the POWER SUPPLY:ALWAYS ON mode after the recognition
process of the cascade
connection is tried again.
The USB disconnection process
is performed for all of the ports on the slave side when the
[RESET] switch on the slave
side is operated.
9
In addition, when the [ServerSelection] switch on the left side of the front panel, the [AutoScan] switch, and the [RESET] switch are pressed at the same time, various
settings are initialized as shown by the following table.
Server name Initialized
AutoScan frequency Initialized
Normal display status Initialized
Setting for whether to display when AutoScan is being performed Initialized
(display is enabled)
HOTKEY settings Initialized
Country code setting Settings retained
POWER SUPPLY:ALWAYS ON Settings retained
EDID Settings retained
SELECT-A/B Settings retained
(5) Ports for server connection
The ports of a KVM Switch are connected to the keyboard/mouse/monitor connectors by using dedicated cables.
(6) Monitor connector
The monitor connector is used to connect the monitor to a KVM Switch.
(7) Keyboard connector
The keyboard connector is used to connect the PS/2 keyboard to a KVM Switch.
(8) Mouse connector
The mouse connector is used to connect the PS/2 mouse to a KVM Switch.
(9) USB keyboard/mouse connector
The USB keyboard/mouse connector is used to connect a USB keyboard, mouse, or
hub to a KVM Switch.
It does not matter which of these is connected for operation. Devices other than a USB keyboard, mouse, or hub cannot be connected.
The maximum number of devices that can be connected is as follows.
4 port type
8 port type
16 port type
Keyboards: 2
Mouse devices: 3
Hubs: 1
Maximum total number of keyboards and mouse devices: 4
Maximum number of hubs:1 level
Note that when wireless type devices are connected using a wireless receiver, a signal
may be output that a mouse or keyboard is connected even though a keyboard or mouse is not actually connected.
10
In this case, devices that are not used are also counted in the number of devices that can be connected.
Point When keyboards or mouse devices are both connected to a PS/2 console and a
USB console, the USB side is given priority and the PS/2 side does not operate.
ORACLE (SUN) server support
- For the FS-1104AU/FS-1108AU/FS-1116AU
Windows server
Standard keyboard (USB)
Keyboard (USB) for ORACLE (SUN)
Yes -
Yes Yes
- For the FS-1104MU/FS-1108MU/FS-1116MU
Windows server
Standard keyboard (USB)
Yes Yes
Keyboard (USB) for ORACLE (SUN) Yes Yes
Note: Pressing the Application key with other keys outputs a dedicated SUN key code.
(10) USB port LED
This LED displays the status of the USB ports.
Status
The relevant USB port is available or is being used
An error occurs for the relevant USB device
- excess current
- unsupported USB device
- the number of connectable USB devices is exceeded
The relevant USB port is recognizing the USB device
(11) Inlet (8 and 16 port type only)
The inlet is used to connect the AC100V power cable. Do not use any cords except for dedicated power cords.
ORACLE (SUN) server
ORACLE (SUN) server
LED display
Green light
Off
Blinking green light
(Note)
11
(12) Connector for the AC Adapter (4 port type only)
This connector is used to connect a dedicated AC adapter. Do not use any cords
except dedicated AC adapters.
(13) Mini USB connector
This connector is not used for normal operations. This connector connects to the server
with a USB cable to use a dedicated application to update the firmware of a KVM Switch.
12
9. Installation
A KVM Switch can be installed as an external device. It can also be installed in a rack. A 4 port KVM Switch can be installed in a rack by using a rack mount panel (FP-P005: sold separately).
Rack installation (4 port type)
(1) Fasten 6 flat head screws at the rear of the rack mount panel (4 screws on the
KVM Switch side, 2 screws on the mask panel side) to attach the rack mount panel (FP-P005: sold separately) to the KVM Switch.
Attach the 6 flat head screws.
(4 screws on the KVM Switch side, 2 screws on the
mask panel side)
(2) Attach the rack mount panel to the rack.
* Rack Fixing Bracket Screws are not provided.
Mask panel
Rack mount panel
Rack front
view
* Rack Fixing Bracket Screws
(2 screws on the right side and two screws
on the left side)
13
Rack installation (8 port and 16 port types)
(1) Remove the console panel from the device.
(2) Attach the Rack Fixing Brackets to the device and the console panel.
Remove the 4 flat head screws
(2 screws on the right side and two screws on the left side)
Console panel
Device side
Attach the Rack Fixing Brackets to the
device with the 6 Rack Fixing Bracket
Screws.
Rack Fixing Bracket
(Small)
Console panel side
Attach the Rack Fixing Bracket
to the console panel with the 4
Rack Fixing Bracket Screws.
Device
Rack Fixing Bracket
(Large)
14
(3) Attach the device and the operation panel to the rack.
* Rack Fixing Bracket Screws
(2 screws on the right side and
two screws on the left side)
Device
Rack rear
view
* Rack Fixing Bracket Screws are not provided.
Attach the provided Wire Fixer as required on the desired location on the rear of the device,
and firmly attach the console panel connection cable to the device and console panel.
Rack front
view
Console panel
* Rack Fixing Bracket Screws
(2 screws on the right side and
two screws on the left side)
Firmly attach the cable without putting
tension on the connector.
The length of the cable
can be adjusted by the
position of the Wire Fixer.
15
Loading...