Preface

Fujitsu would like to thank you for purchasing our power synchronized unit for the ETERNUS DX/AF storage systems.
The power synchronized unit is a device that synchronizes power operations of the ETERNUS DX/AF storage systems with servers.
This manual introduces the user to the power synchronized unit, and explains the regular checks and maintenance that are required.
Please carefully review the information outlined in this manual.
This manual is designed for use with the following ETERNUS DX/AF storage systems:
ETERNUS DX60 S4/DX100 S4/DX200 S4 Hybrid Storage Systems
ETERNUS DX500 S4/DX600 S4 Hybrid Storage Systems
ETERNUS DX60 S3/DX100 S3/DX200 S3 Hybrid Storage Systems
ETERNUS DX500 S3/DX600 S3 Hybrid Storage Systems
ETERNUS DX8100 S3/DX8700 S3/DX8900 S3 Hybrid Storage Systems
ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk Storage Systems
ETERNUS AF250 S2 All-Flash Arrays
ETERNUS AF650 S2 All-Flash Arrays
ETERNUS AF250 All-Flash Arrays
ETERNUS AF650 All-Flash Arrays
ETERNUS DX200F All-Flash Arrays
Applicable Environment
The power synchronized unit was designed and manufactured with user safety for general office environments in mind. When using the power synchronized unit, follow the handling instructions, placement and cautionary notes listed in this manual. If used beyond the limits described, the users may be at risk of personal injury and/or material damage.
Using this Manual
This manual contains important information regarding safe usage. Please read this manual carefully before using the power synchronized unit. Pay special attention to
"
Safety Precautions" (page 9), and understand the contents thoroughly before using the power synchronized
unit. Keep this manual in a safe place for future reference. Fujitsu pays careful attention to the safe use of its products to prevent user injury and/or material damage. To use the power synchronized unit properly, please follow the instructions in this manual.
Tenth Edition October 2017
3
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
Copyright 2017 FUJITSU LIMITED P3AM-8012-10ENZ0
Preface
Compliance with Standards
The power synchronized unit is compliant with the following standards.
Type Standard
Product safety UL60950-1, CSA-C22.2 No. 60950-1, EN60950-1, IEC60950-1
Electromagnetic Compatibility FCC CFR47 part 15 Class A, ICES-003 Class A, EN55022 Class A, VCCI Class A
Electromagnetic Immunity EN55024
CE certification
Environmental compliance
The power synchronized unit is designed, developed and manufactured as contemplated for general use, including without limitation, general office use, personal use, household use, and ordinary industrial use, but is not designed, developed and manufactured for use in situations with accompanying fatal risks or dangers that, unless extremely high safety is secured, could lead directly to death, personal injury, severe physical damage or other loss (hereinafter "High Safety Required Use"), including without limitation, nuclear reaction control in nuclear facility, aircraft flight control, air traffic control, mass transport control, medical life support system, and missile launch control in weapon systems. Do not use the power synchronized unit for High Safety Required Use without securing the sufficient safety level required. If you wish to use the power synchronized unit for High Safety Required Use, please consult with our sales representative before such use.
Electromagnetic Compatibility Directive 2004/108/EC
Low Voltage Directive 2006/95/EC
RoHS-compliant (Restriction of hazardous substances)
WEEE-compliant (Waste electrical and electronic equipment)
The company names, product names and service names mentioned in this document are registered trademarks or trademarks of their respective companies.
Microsoft product screen shot(s) reprinted with permission from Microsoft Corporation.
4
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
Copyright 2017 FUJITSU LIMITED P3AM-8012-10ENZ0
Preface
Traditional Chinese
Simplified Chinese
5
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
Copyright 2017 FUJITSU LIMITED P3AM-8012-10ENZ0
Organization
This manual is composed of the following six chapters:
Chapter 1 Overview
This chapter provides overviews, features, specifications, and system configuration examples of the power synchronized unit. The names and usage of the various components for the power synchronized unit are also described.
Chapter 2 Installation
This chapter describes how to install the power synchronized unit.
Chapter 3 Powering On and Off
This chapter describes how to turn on and off the power synchronized unit.

About this Manual

Chapter 4 Connection and Settings
This chapter describes the connection and setup procedures to operate the power synchronized unit.
Chapter 5 Adding a Connecting Device
This chapter describes how to connect the power synchronized unit when a device is added.
Chapter 6 Operation and Maintenance
This chapter describes how to change the configuration and appropriate responses for any problems that may occur. Read this chapter when operating or performing maintenance on the power synchronized unit, or if an error occurs.
Refer to the manuals for each peripheral concerning details not included in this manual.
6
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
Copyright 2017 FUJITSU LIMITED P3AM-8012-10ENZ0
About this Manual
WARNING
CAUTION
Electric Shock
No Disassembly
Unplug
Warning Notations
Warning signs are shown throughout this manual in order to prevent injury to the user and/or material damage. These signs are composed of a symbol and a message describing the recommended level of caution. The following section explains the symbols, their levels of caution, and their meanings as used in this manual.
This symbol indicates the possibility of serious or fatal injury if the power synchronized unit is not used properly.
This symbol indicates the possibility of minor or moderate personal injury, as well as damage to the power synchronized unit and/or to other users and their property, if the power synchronized unit is not used properly.
This symbol indicates IMPORTANT information for the user to note when using the power synchronized unit.
The following symbols are used to indicate the type of warnings or cautions being described.
The triangle emphasizes the urgency of the WARNING and CAUTION contents. Inside the triangle and above it are details concerning the symbol (e.g. Electric Shock).
The barred "Do Not..." circle warns against certain actions. The action which should be avoided is both illustrated inside the barred circle and written above it (e.g. No Disassembly).
The black "Must Do..." circle indicates actions that must be taken. The required action is both illustrated inside the black circle and written above it (e.g. Unplug).
7
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
Copyright 2017 FUJITSU LIMITED P3AM-8012-10ENZ0
About this Manual
Warning Level Indicator
Warning Type Indicator
Warning Details
To avoid damaging the power synchronized unit, pay attention to the following points when cleaning the power synchronized unit.
Make sure to disconnect the power when cleaning.­Be careful that no liquid seeps into the power synchronized unit when using cleaners, etc.
-
Do not use alcohol or other solvents thinners to clean the power synchronized unit.
-
Warning Layout Ribbon
Example Warning
Do
How Warnings are Presented in this Manual
A message is written beside the symbol indicating the caution level. This message is marked with a vertical ribbon in the left margin, to distinguish this warning from ordinary descriptions. An example is shown here.
Symbols Used in this Manual
About the Latest Version of this Manual and Contact Details
The following symbol is used throughout this manual:
Functions and know how which can be useful when setting up or operating the power synchronized unit.
"ETERNUS DX/AF" refers to the ETERNUS DX60 S4/DX100 S4/DX200 S4, ETERNUS DX500 S4/DX600 S4,
ETERNUS DX60 S3/DX100 S3/DX200 S3, ETERNUS DX500 S3/DX600 S3, and ETERNUS DX8100 S3/DX8700 S3/ DX8900 S3 Hybrid Storage Systems; the ETERNUS DX60 S2/DX80 S2/DX90 S2 Disk Storage Systems; and the ETERNUS AF250 S2/AF650 S2, ETERNUS AF250/AF650 and ETERNUS DX200F All-Flash Arrays in this manual.
The information in this manual is subject to change without notice for improvement and functionality expansion of the power synchronized unit. The latest version of this manual and important service and support contacts (see "Contact Fujitsu") for Fujitsu Customer Service in your country of purchase is available at the following website:
http://www.fujitsu.com/global/support/products/computing/storage/disk/manuals/manual.html
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
Copyright 2017 FUJITSU LIMITED P3AM-8012-10ENZ0
8

Safety Precautions

WARNING
Do Not
Unplug
This section describes safety precautions. Make sure to follow the instructions described below to ensure the safe use of the power synchronized unit.
If you detect an unusual occurrence during operation
If the power cord and/or power plug is damaged, do not use the power
synchronized unit and contact your sales representative or your maintenance engineer. Never attempt to repair the power synchronized unit by yourself. Not doing so may cause electric shock or fire.
If the power synchronized unit overheats, gives off smoke or an unusual odor,
makes an unusual sound, or shakes abnormally, immediately disconnect the power plug from the socket. After the problem has subsided, contact your sales representative or your maintenance engineer. Never attempt to repair the power synchronized unit by yourself. Not doing so may cause electric shock or fire.
If any liquids such as water or foreign objects like metal fragments get into the
power synchronized unit, immediately disconnect the power plug from the socket. Then, contact your sales representative or your maintenance engineer. Do not attempt to repair the power synchronized unit by yourself. Doing so may cause electric shock or fire.
If the power synchronized unit is dropped or covers are damaged, immediately
disconnect the power plug from the socket. Then, contact your sales representative or your maintenance engineer. Do not attempt to repair the power synchronized unit by yourself. Doing so may cause electric shock or fire.
9
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
Copyright 2017 FUJITSU LIMITED P3AM-8012-10ENZ0
Safety Precautions
WARNING
Do Not
Unplug
CAUTION
Do Not
Instructions for installation
Do not place the power synchronized unit in an area with bad ventilation or
where anything that may cause a fire, or flammable gases are generated. Doing so may cause a fire and damage the power synchronized unit.
Do not place the power synchronized unit in locations subject to oil smoke,
steam, humidity and dust, or in places where the power synchronized unit may come into contact with water. Doing so may lead to electric shock, fire, and/or damage the power synchronized unit.
Do not place any objects containing water such as vases and cups on or near
the power synchronized unit. Doing so may cause water to get into the power synchronized unit and lead to electric shock, fire, and/or damage the power synchronized unit.
Do not place the power synchronized unit on an unstable floor. Doing so may
cause the power synchronized unit to fall, resulting in injury or damage to the power synchronized unit.
Do not connect power cords or any other cables to the power synchronized unit
during thunderstorms. Doing so may lead to electric shock and/or fire.
When the power synchronized unit is installed or moved, disconnect the power
plug from the socket. Remove all the connected cables. Watch your step during the operation. Not doing so may damage the power cords and cause electric shock or fire. Failure to do so may also cause the power synchronized unit to fall and injure others.
Do not use the power synchronized unit in an area affected by corrosive gas or
in a salty environment. Doing so may cause device failure.
Do not knock or place heavy objects on the power synchronized unit or
optional products. Doing so may cause injury or damage the power synchronized unit.
10
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
Copyright 2017 FUJITSU LIMITED P3AM-8012-10ENZ0
Safety Precautions
CAUTION
Do Not
Do
WARNING
No Disassembly
Do Not
Do not place the power synchronized unit in areas with strong magnetic fields,
such as in the vicinity of TVs or speakers. Doing so may damage the power synchronized unit and cause the power synchronized unit to malfunction.
Do not place power cords and other cables in locations where they may
become trip hazards. Doing so may cause injury or damage the power synchronized unit .
Do not place the power synchronized unit on a slanted or unstable surface or
in areas that tend to shake. Doing so may cause it to tip over and injure others. Also, do not place the power synchronized unit in high traffic areas such as in a hallway. Passersby can shake the unit, damage it or cause mal­function.
Place the power synchronized unit in an environment in which the
temperature and humidity satisfy the environmental conditions described in
"1.3
Specifications" (page 23).
- For 24-hour operation, ensure that the schedule for air conditioning is able
to maintain the required temperature. Failure to do so may result in damage to the device.
- During the winter, control the heating system to limit ambient
temperature rises to less than 15C per hour to prevent condensation. Failure to do so could lead to electric shock and damage the power synchronized unit.
Handling the power synchronized unit
Do not attempt to repair, disassemble, or remodel the power synchronized
unit by yourself. Doing so may cause electric shock or fire.
Do not use a voltage other than that indicated. Doing so may cause electric
shock or fire.
11
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
Copyright 2017 FUJITSU LIMITED P3AM-8012-10ENZ0
Safety Precautions
WARNING
Do Not
Do
Do not handle the power plug with wet hands. Doing so may cause electric
shock.
Do not wind power cords too tightly at the root of the power cord. Doing so
stresses the cords and may expose or snap the inner wires, which can lead to electric shock or fire.
Do not damage or modify the power cord or the power plug. Heating, forced
bending, twisting, pulling, or placing heavy objects on the power cord or the power plug will damage it, causing electric shock or fire.
Do not plug all the power cords into a single outlet. Doing so may cause
electric shock or fire.
Do not use a power cord that does not satisfy the specifications of the power
synchronized unit and the AC sensor unit. Doing so may cause electric shock, fire, or device failure.
Do not use any products other than the optional products for the power
synchronized unit. Doing so may cause electric shock, fire, or device failure.
Do not insert or drop foreign objects such as metals or flammable objects into
openings in the power synchronized unit such as air vents. Doing so may cause electric shock, fire, or device failure.
Do not obstruct the openings in the power synchronized unit such as air vents.
Doing so may cause overheating that leads to fire and device failure.
Do not use any flammable type cleaning sprays. Doing so may cause fire or
device failure.
Use only power sockets that have a ground. Failure to do so may cause electric
shock, fire, or malfunction.
Disconnect the power plug from the socket during thunderstorms. Failure to
do so may lead to electric shock, fire, or device failure.
Ensure the power plug is fully inserted into the socket. Failure to do so may
cause electric shock or fire.
12
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
Copyright 2017 FUJITSU LIMITED P3AM-8012-10ENZ0
Safety Precautions
WARNING
Do
Do Not Wet
Unplug
CAUTION
Do Not
Do
Install optional products for the power synchronized unit by following the
instructions described in this manual. If an optional product is installed in any other way, device failure or electric shock may occur.
Do not pour or spill water on the power synchronized unit. Doing so may cause
electric shock, fire, or device failure.
When unplugging the power plug, do not pull on the cable, hold the plug.
Pulling the cable may expose or snap the inner wires, which can lead to electric shock or fire.
Use a dry cloth to remove all dust from plugs and sockets. Not doing so may
cause electric shock or fire.
When the power synchronized unit is not used for a long period of time,
unplug all power plugs. Failure to do so may lead to fire.
When the power synchronized unit is pulled out from the rack, make sure not
to hit your head if you are operating devices under the power synchronized unit. Not doing so may cause injury.
Do not put your finger into the inlet/outlet. Doing so may cause injury or
device failure.
Do not remove the cover from the power synchronized unit inlet/outlet unless
necessary. Doing so may cause device failure.
Do not use devices such as mobile phones that emit radiation in the vicinity of
the power synchronized unit. Doing so may cause malfunction.
Before applying insecticides for pest control, turn off the power synchronized
unit and cover it with a plastic sheet. Not doing so may damage the power synchronized unit.
13
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
Copyright 2017 FUJITSU LIMITED P3AM-8012-10ENZ0
Safety Precautions
CAUTION
Do
CAUTION
Do
Instructions for rack installation
Note the following points when cleaning the power synchronized unit. Failure
to do so may cause device failure.
- Make sure the power synchronized unit is turned off.
- Do not allow liquids such as cleaner to get into the power synchronized
unit.
- Never use organic solvents such as alcohol or thinner to clean the power
synchronized unit.
Especially for an enclosed rack with doors, or when multiple devices are to be
mounted and running, it is important to realize that the temperature inside the cabinet will be considerably higher than that of the room. Make sure the rack internal ambient temperatures do not exceed the environmental conditions for temperature described in "1.3 to do so may damage the power synchronized unit.
When installing the power synchronized unit with other devices into the same
rack, the airflow of the device installed on and under the power synchronized unit may interfere with each other and reduce the effect of device cooling. Make sure to leave plenty of room between the devices if required. Failure to do so may damage the power synchronized unit and lead to malfunction.
When installing the power synchronized unit in a rack, be careful not to pinch
your fingers in the rack. Doing so may cause injury.
Install the blank panels provided with the rack where no other devices are
installed. Failure to do so may cause the power synchronized unit to overheat, resulting in damage to the device.
When moving the rack after installing the power synchronized unit, make sure
to contact your sales representative or your maintenance engineer. Do not move the rack by yourself. Doing so may cause injury and/or damage the power synchronized unit.
Specifications" (page 23). Failure
14
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
Copyright 2017 FUJITSU LIMITED P3AM-8012-10ENZ0
Safety Precautions
CAUTION
Do Not
Do
90
Do not bend more than 90 degrees
Do not fold
Handling cables
Do not damage or modify the cables such as heating, forced bending,
twisting, pulling, or placing heavy objects on them. Doing so may damage the cables and cause the power synchronized unit to malfunction.
Do not forcibly bend or fold the cable. Doing so may damage the cable and
cause the power synchronized unit to malfunction.
Firmly insert cable connectors into inlets, outlets, or sockets. Failure to do so
may cause the power synchronized unit to malfunction.
When inserting or removing the cable, only hold the connector. Do not hold
the cable. Doing so may damage the cable and cause the power synchronized unit to malfunction.
Remove any dirt, dust, oil, grease, etc on cable connectors. Failure to do so
may cause the power synchronized unit to malfunction.
15
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
Copyright 2017 FUJITSU LIMITED P3AM-8012-10ENZ0

Labels

Manufacturer’s label
Indicates the model, serial number, etc. This label is attached to the plate in the label holder on the bottom of the power synchronized unit. It can be checked by pulling out the plate when the power synchronized unit is installed in a rack.
Manufacturer’s label
Indicates the model, serial number, etc.
Warning labels and manufacturer's labels are found in various places of the power synchronized unit, as shown in the example below. Never remove these labels from the equipment or allow them to become dirty.
Power synchronized unit
AC sensor unit
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
16
Copyright 2017 FUJITSU LIMITED P3AM-8012-10ENZ0

Table of Contents

Chapter 1 Overview 21
1.1 External View .................................................................................................................... 21
1.2 Features ............................................................................................................................ 22
1.3 Specifications .................................................................................................................... 23
1.4 Components ...................................................................................................................... 24
1.4.1 Power Synchronized Unit ...............................................................................................................................24
1.4.2 AC Sensor Unit (Optional) .............................................................................................................................. 26
1.5 System Configuration ........................................................................................................27
1.6 Power Management for Power Synchronization ................................................................ 29
Chapter 2 Installation 33
2.1 Package Contents Check ................................................................................................... 33
2.2 Preparation ....................................................................................................................... 34
2.2.1 Installation Area ............................................................................................................................................ 34
2.2.2 Checking Power Sockets and Server UPS Unit Outlets .................................................................................... 34
2.2.3 Preparing Power Cords ...................................................................................................................................34
2.3 Installing in a Rack ........................................................................................................... 35
2.3.1 Installing a Power Synchronized Unit ............................................................................................................ 36
2.3.2 Installing an AC Sensor Unit ........................................................................................................................... 39
Chapter 3 Powering On and Off 43
Chapter 4 Connection and Settings 44
4.1 Setting the ETERNUS DX/AF ............................................................................................... 45
4.2 Turning on the Power Synchronized Unit .......................................................................... 50
4.3 Connecting Cascade Cables ............................................................................................... 53
4.4 Connecting to the Server UPS Unit ....................................................................................56
4.4.1 Connecting the Server UPS Unit to the Power Synchronized Unit ................................................................... 57
4.4.2 Connecting the AC Sensor Unit ...................................................................................................................... 58
4.5 Connecting to the ETERNUS DX/AF .................................................................................... 61
17
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
Copyright 2017 FUJITSU LIMITED P3AM-8012-10ENZ0
Table of Contents
4.6 Checking after Connection ................................................................................................64
Chapter 5 Adding a Connecting Device 65
5.1 Connection Procedure When Adding a Server ................................................................... 65
5.2 Connection Procedure When Adding an ETERNUS DX/AF ................................................... 67
Chapter 6 Operation and Maintenance 71
6.1 Checking the Power Synchronized Unit Status .................................................................. 71
6.2 Device Replacement After Operation Startup .................................................................... 71
6.2.1 Replacing a Server .........................................................................................................................................71
6.2.2 Replacing a Power Synchronized Unit ............................................................................................................ 72
6.2.3 Replacing an AC Sensor Unit .......................................................................................................................... 72
6.3 Troubleshooting ................................................................................................................ 73
6.3.1 Check List ...................................................................................................................................................... 73
6.3.2 Trouble Record ............................................................................................................................................... 76
18
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
Copyright 2017 FUJITSU LIMITED P3AM-8012-10ENZ0

List of Figures

Figure 1.1 External view of a power synchronized unit ................................................................................................ 21
Figure 1.2 External view of an AC sensor unit .............................................................................................................. 21
Figure 1.3 Components (power synchronized unit)...................................................................................................... 24
Figure 1.4 Components (AC sensor unit) ...................................................................................................................... 26
Figure 1.5 System configuration example (power synchronization with two server UPS units) .................................... 27
Figure 1.6 System configuration example (power synchronization with three or more server UPS units) .................... 28
Figure 1.7 Power on using a power synchronized unit ................................................................................................. 29
Figure 1.8 Operation timing chart when using a power synchronized unit (powering on) ........................................... 30
Figure 1.9 Power off using a power synchronized unit ................................................................................................. 31
Figure 1.10 Operation timing chart when using a power synchronized unit (powering off) ........................................... 32
Figure 4.1 ETERNUS DX60 S4/DX100 S4/DX200 S4, ETERNUS DX500 S4/DX600 S4,
ETERNUS DX60 S3/DX100 S3/DX200 S3, ETERNUS DX500 S3/DX600 S3, ETERNUS DX8100 S3, ETERNUS AF250 S2/AF650 S2, ETERNUS AF250/AF650, and
ETERNUS DX200F setup (Setup Power Management screen)....................................................................... 45
Figure 4.2 ETERNUS DX8700 S3/DX8900 S3 setup (Setup Power Management screen)................................................ 47
Figure 4.3 ETERNUS DX80 S2/DX90 S2 setup (Setup Power Management screen)........................................................ 48
Figure 4.4 ETERNUS DX60 S2 setup (Setup Power Management screen)...................................................................... 49
Figure 4.5 Cascade cable connection............................................................................................................................ 53
Figure 4.6 Connection for the server UPS units and the AC sensor units....................................................................... 56
Figure 6.1 Trouble record ............................................................................................................................................. 76
19
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
Copyright 2017 FUJITSU LIMITED P3AM-8012-10ENZ0

List of Tables

Table 1.1 Specifications .............................................................................................................................................. 23
Table 1.2 Status and meanings of each LED (for power synchronized units) .............................................................. 25
Table 1.3 Status and meanings of each LED (for AC sensor units)............................................................................... 26
Table 2.1 List of package contents (power synchronized unit).................................................................................... 33
Table 2.2 List of package contents (AC sensor unit).................................................................................................... 33
20
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
Copyright 2017 FUJITSU LIMITED P3AM-8012-10ENZ0
Chapter 1
Overview
This chapter provides external views, features, specifications, and system configuration examples of the power synchronized unit and the AC sensor unit (optional). The names and usages of the various components of the power synchronized unit and the AC sensor unit are also described.

1.1 External View

Figure 1.1 and Figure 1.2 show the external views of the power synchronized unit and the AC sensor unit.
Power synchronized unit
Figure 1.1 External view of a power synchronized unit
AC sensor unit
Figure 1.2 External view of an AC sensor unit
21
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
Copyright 2017 FUJITSU LIMITED P3AM-8012-10ENZ0
Chapter 1 Overview

1.2 Features

1.2 Features
This section explains the features of the power synchronized unit and the AC sensor unit.
Powering the ETERNUS DX/AF on and off can be synchronized with a server by connecting to the
Uninterruptible Power Supply (UPS) unit to which the server is connected. As well as the UPS unit to which the server is connected (referred to as "server UPS unit" in the remainder of this manual), the power synchronized unit can be connected to a unit that can control the output of an AC outlet.
The sizes of the power synchronized unit and the AC sensor unit are 1U. These units can be installed in a
19-inch rack for the server or the ETERNUS DX/AF.
Two server UPS units can be connected to manage power synchronization in a standard configuration. By
adding an AC sensor unit, up to 16 server UPS units can be connected.
By serially connecting each AC sensor unit, the distance between a server UPS unit and a power
synchronized unit can be extended by up to 100m.
By cascading power synchronized units, the power of up to eight ETERNUS DX/AF storage systems can be
controlled.
A redundant configuration is available by using two power synchronized units.
Power synchronization starts when the power synchronized unit is connected to the server UPS unit and
the ETERNUS DX/AF by cables. Connection procedures can be performed while the server UPS unit and the ETERNUS DX/AF are operating.
The status of the power synchronized unit and the status of the AC power output from the server UPS unit
are displayed on the LED. If an error occurs, tracking the error and error recovery can be performed based on the LED information.
22
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
Copyright 2017 FUJITSU LIMITED P3AM-8012-10ENZ0
Chapter 1 Overview

1.3 Specifications

1.3 Specifications
Table 1.1 shows the specifications of the power synchronized unit and the AC sensor unit.
Table 1.1 Specifications
Dimensions (W D H)
Weight
Power
Maximum power requirements
Maximum heat generation
Connection interface
Server UPS unit
Number of
connectable
devices
ETERNUS DX/AF
Cable length
Conditions to detect AC output
Support for a duplicated configuration Yes
Environmental condition
Item Specifications
Power synchronized unit 440 230 40 (mm) [1U]
AC sensor unit 100 150 40 (mm) [1U]
Power synchronized unit 4.0kg
AC sensor unit 1.3kg
Voltage AC100 - 120V, AC200 - 240V
Phase Single
Frequency 50Hz/60Hz
AC100 - 120V 3W
AC200 - 240V 7W
AC100 - 120V 11kJ/h
AC200 - 240V 26kJ/h
For ETERNUS DX/AF storage systems RS232C  4
For AC detection AC sensor 2
Basic 2
Maximum (when AC sensor units are connected)
Basic 4
Maximum (when a cascade connection is used)
Between a power synchronized unit and an AC sensor unit (total)
Between a power synchronized unit and the ETERNUS DX/AF
Between power synchronized units Max. 10m
Power consumption
Voltage AC100V / AC200V
Phase Single
Temperature
Humidity
0.1A or less AC output for one second or
5 - 40C (during operation)
0 - 50C (during non-operation)
20 - 80%RH (during operation)
8 - 80%RH (during non-operation)
16
8
Max. 100m
Max. 5m
more is detected.
23
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
Copyright 2017 FUJITSU LIMITED P3AM-8012-10ENZ0
Chapter 1 Overview
AC IN port
For power cord (for AC power input) connection
RCI port
Not used
PWC ports (#0, #1, #2, #3 from left)
For ETERNUS DX/AF connection with
RS232C cables to a power synchronized unit
AC SENSOR port
- For AC sensor unit connection with an AC sensor port connection cable to a power synchronized unit
- For cascading two power synchronized units with a cascade cable to the AC SENSOR port on the second power synchronized unit
CASCADE port
For cascading two power synchronized units with a cascade cable to the CASCADE port on the first power synchronized unit
SENSOR ports (left: #0, right: #1)
For power cord (for AC sensor) connection to detect the power status of a server UPS unit
POWER LED
Displays the power status of a power synchronized unit
POWER SENSOR LED
Displays the detection status of AC output from a server UPS unit
POWER CONTROL LED
Displays the power status of the connected ETERNUS DX/AF
CHECK LED
Displays the starting status of a power synchronized unit

1.4 Components

1.4 Components
This section describes the names and usage of the various components for the power synchronized unit and the AC sensor unit.

1.4.1 Power Synchronized Unit

Figure 1.3 shows the names and usage of the various components for the power synchronized unit.
Figure 1.3 Components (power synchronized unit)