Preparation & Installation Area
S T E P
Check that the installation area meets the space requirements
of the rack in which the ETERNUS DX60/DX80 is to be installed.
Installation space
Installation requirements
Chec k that the installation area satisfies all the requirements
Disk storage system Safety Precautions"
Prepare the following items Secure the Installation Area
Temperature: 5 – 40°C Humidity: 20 – 80%RH
Environmental conditions
Power outlets
Chec k that a sufficient number of suitable wall outlets are available.
Check the Package Contents
S T E P
Refer to the "Package Contents" and check that there are no missing items.
The latest version of this document and the latest information about the ETERNUS DX60/DX80 is released in the following web-site. Access the following address if needed.
http://w ww.fujitsu.com /global/services/computing/storage/eternus/products/diskstorage/dx 60-dx80/
The company names, product names and ser vice names mentioned in this document are registered trademarks or trademarks of their respective companies.
Copyright 2009 FUJITSU LIMITED
This guide describes the workow required to proceed from installation to
operation of the (Fibre Channel model).
P3AM-3082-02EN
Setup Guide (Fibre Channel model)
Read and understand the "Safety Precautions"
before use.
"Safet y Precau tions"
ETERNUS DX60/DX80 Setup
Setting up the ETERNUS DX60/DX80 to Support Maintenance
Server Connection
Operation and Maintenance
Preparation & Installation Area
Check the Package Contents
Installation
Cable Connection
Pre-Setup Preparation
Workow
Read this Setup Guide first
Disk storage system
1
2 3 4 5
6 7
8 9
The following items need to be prepared in advance:
IP addresses and subnet mask
(for the ETERNUS DX60/
DX80 and maintenance engineer PC)
Network equipment such as a switching hub Web browser
(Microsoft® Internet Explorer 6.0 or 7.0, Mozilla
Firefox™ 3.0.x)
Make sure that all of the following manuals are handy:
Documentation CD "Safety Precautions" "Package Contents"
"3.1 Preparat ion" in the " User Gui de" "Safet y Precau tions"
"4.1 Prior Preparation" in the " User Gui de"
"Packa ge Contents"
Proceed to next step
ETERNUS DX60/DX80
Rack mount kit
Misc. cables
Misc. documents
Page 2
S T E P
Installation
The rack rail (bracket) needs to be attached to the rack and the ETERNUS DX60/DX80 mounted.
2. Attach the rack rails (brackets) to the rack. The size of the ETERNUS DX60/DX80 is 2U.
ETERNUS DX60/DX80
1st position
(M5 screws)
3rd position
(M5 screws)
1st position
(M5 screws)
3rd position
(M5 screws)
2U
[Screw location of the rack rail (bracket)]
Tighten the screws in the same locations on both the front and rear sides of the rack pillars
[Left] [Right]
Rack rail (bracket)
Base line of the ETERNUS DX60/DX80
(Front rack pillars)
(Rear rack pillars)
"R" is stamped on the inner side of the right rack rail.
"L" is stamped on the inner side of the left rack rail.
Loosen the screws, and adjust the rack rails to the depth of the rack.
[Left]
[Right]
4. Fasten the ETERNUS DX60/DX80 to the rack.
3. Mount the ETERNUS DX60/DX80 in the rack.
●
Make sure to install or remove the enclosure
to or from the rack by two or more people.
●
Multiple Drive Enclosures must be connected
to the controller enclosure following the order
of the "D E_ No. label" numbers attached to
eac h D rive Enclosure. The position of the
labels are in the positions shown below.
IMPORTANT
Between the EXP#0 and
EXP#1 expanders at the rear
of the drive enclosure
DE_No. label
At the right side of the front of
the drive enclosure
"3.2 R ack Installation" in the "Us er Guide"
S T E P
Cable Connection
When Drive Enclosures are installed, miniSAS cables are used to connect between the SAS ports of the enclosures. Connect the Controller Enclosure to Drive Enclosure 1, Drive Enclosure 1 to Drive Enclosure 2, Drive Enclosure 2 to Drive Enclosure 3, etc. T he number of Drive Enclosure can be checked with the "DE_No." label.
Var ious cable s need to be connected to t he rear of the
ETERNUS DX60/DX80.
Rear view
Controller Enclosure
Cable
LAN Cables
MiniSAS Cables
Use release ties to hold the power cords in place.
Power Cords
Rear view
Controller Enclosure
Drive Enclosure
Cord
Rear view
Controller Enclosure
Drive Enclosure
Drive Enclosure
Cable
Fibre Channel Cables
Rear view
Controller Enclosure
Cable
"4.2.1 LAN Cable Connec tion (For Operation Manag ement)" in th e "User G uide"
"4.2.2 Fibre Channel Cable Connection (For Fibre Channel) " in the "User Guide"
The SAS (OUT) port is on the left side, and SAS (IN) port is on the right side.
Insert the connector with a mark on its underside in the SAS (OUT) port. Inser t the connector with a mark on its underside in the SAS (IN) port.
"4.2.5 MiniSAS Cable Connection (For Dr ive Enclo sures)" in the " User Guide"
"4.2.6 Power C ord Con nectio n" in the"U ser Guide"
To he lp wi th cable management and prev ent
incorrect connection, attach labels to the cables
and note where each cable is connected to and
from.
Point
The c ab le s should never b e bent, t wisted or
pulled.
IMPORTANT
Underside of the SAS (OUT) side plug
Underside of the SAS (IN) side plug
The RMT port is on the left side, and MNT port
is on the right side.
The MNT port must always be connected. The
RMT port onl y needs to be co nnected when the remote
support connection is to be independent of the customer
network.
The left port is 0, and right port is 1.
Connect a Fibre Channel cable to each CM port.
1. Adjust the rack rail (bracket)
size to t the rack.
Example for connection of miniSAS cable (when two Drive Enclosures are installed)
Page 3
The following steps need to be per formed before star ting the ETERNUS DX60/DX80 setup procedure:
ETERNUS DX60/DX80 Setup
S T E P
Set the necessar y environment for operating the ETERNUS
DX60/DX80 with its initial setup.
The [Initial Setup] screen appears by clicking t he [Ini ti al
Setup] menu on the [Easy Setup] tab.
This screen is used to set the following items:
Set Date and Time Change password
Change Storage System Name Set Network Environment
After completing these settings with the Finish step, close
the web browser to end the setup session, then detach the
direct c onnection L AN c able (for ope ration management)
fro m the setup PC and connect it to the normal network.
Then try logging on again via the normal network, using the
IP address that has just been set.
Initial Setup
Pre-Setup Preparation
S T E P
1. Fill in the IP address and subnet mask elds on the Network Setting label.
2. Attach it to the rear upper central label plate.
3. Connect the PC and the ETERNUS DX60/DX80 using a LAN cable (for operation management).
4. Give the PC the following network settings:
IP address: 192.168.1.2 Subnet mask: 255.255.255.0
5. Set the Web browser not to use a proxy server or web caching.
6. Check that Java Script and style sheets, and cookies are enabled as an operating condition for the Web browser.
7. Turn on the ETERNUS DX60/DX80.
1. The connected PC may be used to setup the ETERNUS DX60/DX80. Start the Web browser and enter either of the following URLs in the address bar:
http://192.168.1.1/
https://192.168.1.1/
2. Enter the following user name and password, and click the [Logon] button to logon to the ETERNUS DX60/DX80.
User name: root
Password: root (Default)
3. Af t er log gin g o n, the St orag e S yst em Sta tus sc r een appears.
Basic ETERNUS DX60/DX80 setup is performed by accessing
the "Initial Setup" and "Conguration Wizard" functions with a
Web browser.
"4.3 ETERNUS DX60/DX8 0 Setup" in t he "User Guide"
The first time the power is turned on, volume
for matt ing may start ac co rding to the factor y
default settings. This does not af fect the setup
operation, which may be started immediately.
IMPORTANT
Per form the necess ar y set tings to operate the ETER NUS
DX60/DX80 using the Conguration Wizard.
The [Configuration Wizard] screen appears by clicking the
[Conguration Wizard] button on the [Easy Setup] tab.
Register hot spares for use in case the regular disks fail.
The [Assign Hot Spare] screen appears by clicking [Assign
Hot Spare] under the [RAID Group Management] menu on the
[Volume Settings] tab.
Set the connecting information for FC port to connect to the server.
The [Set FC Port Parameters] screen appears by clicking [Set
FC Port Parameters] under the [Host I/F Management] menu
on the [Global Settings] tab.
This screen is used to set the following items:
Connection (Factory default is "FC-AL")
Set Loop ID (Required when "Connection" is "FC-AL")
Loop ID (Required when "Connection" is "FC-AL")
Transfer Rate
 
Host Afnity
Host Response (Required when "Host Afnity" is "Disabled")
Configuration Wizard
Assigning Hot Spares
Setting FC Port parameters
Create RAID Group Congure Afnity Group
Create Volume
Dene LUN Mapping
Dene Host
"4.3.3 Con guration Wizar d" in the" User Guid e"
"4.3.4.Hot S pare Regi stration" in the"User Guid e"
"5.4 Host I/F Management " in the " Web GUI Us er Guide"
Default RA ID groups, volumes and hot spares
disks are preset in the factory. Refer to "Web GUI
User Guide" if the preset values are to be changed.
Point
"4.3.2 Initial Setup" in the"Us er Guide"
Page 4
Setting up the ETERNUS DX60/DX80 to Support Maintenance
S T E P
Server Connection
S T E P
Operation and Maintenance
S T E P
Various settings are needed to make certain post-operation maintenance tasks easier.
Notication of ETERNUS DX60/DX80 problems as they occur is possible if the event notication method and level have
been set.
For e-mail notication of ETERNUS DX60/DX80 problems, a destination e-mail address must be set.
If the ETERNUS DX60/DX80 is to be connected to a PRIMERGY and " ServerV iew" used to monitor the server, the
ETERNUS DX60/DX80 needs to be set to send SNMP traps to the server.
If remote suppor t is required, the ETERNUS DX60/DX80 needs to be set to notify the remote support center of failures.
"4.4 Maintena nce Setup" in the "Us er Guide"
Remote suppor t allows prompt detection and resolution of trouble.
Point
Various tasks need to be performed before the ETERNUS DX60/DX80 can be connected to the server. These include the
installation of the appropriate drivers and the setup of Fibre Channel switches.
Check which server OS, Fibre Channel cards, and Fibre Channel switches are to be connected to before starting this step.
All necessary settings are complete, and the ETERNUS DX60/DX80 is now ready for normal operation.
"4.5 Settin g up the Ser ver Con nectio n" in the "User Guide" "ETER NUS Disk storage sy stems Ser ver Con nectio n Guide (Fi bre Channe l)"
- for Solar is™ Operatin g System
- for Linux
- for HP- UX - E TERNU S Disk Storage System Setti ngs for ET ERNUS DX6 0/DX80
- for AIX - Fibr e Channel S witch Set tings
- for Windo ws® - f or Egenera BladeFrame
- for VMwa re® ESX
Status check
Data backup
Maintenance support period
The status of the ETERNUS DX60/DX80 should be regularly monitored by checking the LEDs and using the Web browser.
Important data should be regularly backed up to a tape drive or similar device as a precaution against system failures.
The maintenance support period for the ETERNUS DX60/DX80 is 5 years from the date of purchase.
Maintenance af ter starting operation:
This manual uses recycled paper.
ETERNUS DX60/DX8 0 Disk sto rage syste m Setup Gui de
(Fibre Channel mode l)
P3AM -30 82-02 EN
Date of issu ance: October 20 09
Issuanc e responsibilit y: FUJIT SU LIMIT ED
Printed in Japan
The conte nts of this m anual may be updated wi thout not ice. W hile the contents of this m anual are the product of all due care and
dilige nce, no responsibilit y can be accepted for ope ratio nal pro blems ari si ng from any error s or m is sin g infor ma tio n, or other use of the information contained i n this manual.
Fujit su assumes no lia bility for dama ges t o thi rd party copyr ight s or
other rights aris ing from t he use of any information in this m anual.
C onten ts of this m anual are no t to be repr oduc ed without permissi on
from Fujit su.
Manuals with missin g or wr ongly c ollate d pages will b e replaced fr ee of
charge.
Loading...