Fujitsu AUXG24LRLB, AUXG30LRLB, AUXG54LRLB, AOYG18LBCA, AOYG24LBCA Technical Manual

...
DESIGN & TECHNICAL MANUAL
AIR CONDITIONER
Cassette type
INDOOR
AUXG18LRLB AUXG24LRLB AUXG30LRLB
AUXG36LRLB AUXG45LRLB AUXG54LRLB
OUTDOOR
AOYG30LBTA AOYG36LBTA
AOYG45LBTA AOYG54LBTA
DR_AU002EF_03
2016.02.09
Notices:
• Product specifications and design are subject to change without notice for future improvement.
• For further details, please check with our authorized dealer.
Copyright © 2015, 2016 Fujitsu General Limited. All rights reserved.
CONTENTS
Part 1. INDOOR UNIT ........................................................................1
1. Product features ......................................................................................2
1-1. Model lineup ..............................................................................................................2
1-2. Features .....................................................................................................................2
2. Wired remote controller .........................................................................5
2-1. Features .....................................................................................................................5
2-2. Overview ....................................................................................................................9
2-3. Specifications ...........................................................................................................10
2-4. Wiring specifications ................................................................................................10
3. Specifications ........................................................................................11
3-1. Models: AUXG18LRLB and AUXG24LRLB .............................................................11
3-2. Models: AUXG30LRLB, AUXG36LRLB, AUXG45LRLB, and AUXG54LRLB .........13
4. Dimensions ............................................................................................15
4-1. Models: AUXG18LRLB and AUXG24LRLB .............................................................15
4-2. Models: AUXG30LRLB, AUXG36LRLB, AUXG45LRLB, and AUXG54LRLB .........17
4-3. Installation space requirement .................................................................................19
5. Wiring diagram .......................................................................................21
5-1. Models: AUXG18LRLB, AUXG24LRLB, AUXG30LRLB, AUXG36LRLB,
AUXG45LRLB, and AUXG54LRLB .................................................................................21
6. Capacity table ........................................................................................22
6-1. Cooling capacity ......................................................................................................22
6-2. Heating capacity ......................................................................................................25
7. Fan performance ....................................................................................27
7-1. Air velocity distributions ...........................................................................................27
7-2. Airflow ......................................................................................................................39
7-3. Fresh-air characteristics ..........................................................................................45
7-4. Duct connection .......................................................................................................46
8. Operation noise (sound pressure) .......................................................49
8-1. Noise level curve .....................................................................................................49
8-2. Sound level check point ...........................................................................................52
9. Safety devices ........................................................................................53
10. External input and output .....................................................................54
10-1.External input ..........................................................................................................54
10-2.External output ........................................................................................................56
10-3.Combination of external input and output ...............................................................57
10-4.Details of function ...................................................................................................59
11. Function settings ...................................................................................65
11-1.Function settings on indoor unit ..............................................................................65
11-2.Function settings by using remote controller ..........................................................67
12. Wired remote controller (Touch panel) ................................................74
CONTENTS (continued)
12-1.Remote controller address setting .......................................................................... 74
12-2.Remote controller master/slave setting .................................................................. 76
12-3.Memory backup setting .......................................................................................... 76
13. Optional parts ........................................................................................77
13-1.Controllers .............................................................................................................. 77
13-2.Cassette grille ......................................................................................................... 78
13-3.Others ..................................................................................................................... 78
CONTENTS (continued)
Part 2. OUTDOOR UNIT ..................................................................81
1. Specifications ........................................................................................82
1-1. Models: AOYG18LBCA and AOYG24LBCA ............................................................82
1-2. Models: AOYG30LBTA and AOYG36LBTA ............................................................83
1-3. Models: AOYG45LBTA and AOYG54LBTA ............................................................84
2. Dimensions ............................................................................................85
2-1. Models: AOYG18LBCA and AOYG24LBCA ............................................................85
2-2. Models: AOYG30LBTA and AOYG36LBTA ............................................................86
2-3. Models: AOYG45LBTA and AOYG54LBTA ............................................................87
2-4. Installation space requirement .................................................................................88
3. Refrigerant circuit ..................................................................................97
3-1. Models: AOYG18LBCA and AOYG24LBCA ............................................................97
3-2. Models: AOYG30LBTA and AOYG36LBTA ............................................................98
3-3. Models: AOYG45LBTA and AOYG54LBTA ............................................................99
4. Wiring diagrams ...................................................................................100
4-1. Models: AOYG18LBCA and AOYG24LBCA ..........................................................100
4-2. Model: AOYG30LBTA ............................................................................................101
4-3. Model: AOYG36LBTA ............................................................................................102
4-4. Models: AOYG45LBTA and AOYG54LBTA ..........................................................103
5. Capacity compensation rate for pipe length and height difference 104
5-1. Model: AOYG18LBCA ...........................................................................................104
5-2. Model: AOYG24LBCA ...........................................................................................105
5-3. Model: AOYG30LBTA ............................................................................................106
5-4. Model: AOYG36LBTA ............................................................................................107
5-5. Model: AOYG45LBTA ............................................................................................108
5-6. Model: AOYG54LBTA ............................................................................................109
6. Additional charge calculation .............................................................110
6-1. Models: AOYG18LBCA and AOYG24LBCA ..........................................................110
6-2. Models: AOYG30LBTA and AOYG36LBTA ..........................................................110
6-3. Models: AOYG45LBTA and AOYG54LBTA ..........................................................110
7. Airflow ...................................................................................................111
7-1. Model: AOYG18LBCA ...........................................................................................111
7-2. Model: AOYG24LBCA ...........................................................................................111
7-3. Model: AOYG30LBTA ............................................................................................111
7-4. Model: AOYG36LBTA ............................................................................................112
7-5. Model: AOYG45LBTA ............................................................................................112
7-6. Model: AOYG54LBTA ............................................................................................112
8. Operation noise (sound pressure) .....................................................113
8-1. Noise level curve ...................................................................................................113
8-2. Sound level check point .........................................................................................117
9. Electrical characteristics ....................................................................118
CONTENTS (continued)
10. Safety devices ......................................................................................119
11. External input and output (Only for
AOYG45LBTA and AOYG54LBTA) ...121
11-1.External input ........................................................................................................ 121
11-2.External output ..................................................................................................... 123
12. Function settings (Only for AOYG45LBTA and AOYG54LBTA) ................125
12-1.Local setting switch buttons .................................................................................. 125
12-2.Local setting procedure ........................................................................................ 127
13. Optional parts ......................................................................................130
Part 1. INDOOR UNIT
CASSETTE TYPE:
AUXG18LRLB AUXG24LRLB AUXG30LRLB AUXG36LRLB AUXG45LRLB AUXG54LRLB
- 2 -
CASSETTE TYPE
AUXG18-54LRLB
1. Product features
Implemented core technology provides easy-to-use product operations that realize a comfortable space.
1-1. Model lineup
1-2. Features
Energy efficiency class
Energy saving
• All DC design
• Heat exchange efficiency increased and larger airflow by adoption of new type turbo fan
AUXG18LRLB AUXG24LRLB AUXG30LRLB AUXG36LRLB AUXG45LRLB AUXG54LRLB
AOYG18LBCA AOYG24LBCA
AOYG30LBTA AOYG36LBTA
AOYG45LBTA AOYG54LBTA
MODEL
AUXG18LRLB AUXG24LRLB AUXG30LRLB AUXG36LRLB
Cooling
A
++
A
++
A
++
A
++
Heating
A
+
A
+
A
+
A
+
- 3 -
CASSETTE TYPE
AUXG18-54LRLB
Advancement in comfort
Quiet operation
Individual airflow provides free air conditioning
• Individual airflow can be controlled by wired remote controller.
• Individual airflow also can be controlled in any positions.
Wide airflow achieved quick air conditioning around all direc-
tions
• New wide louver can provide more airflow.
• The louver design distributes airflow at the corner.
• Uniform temperature air conditioning by airflow
Case study:
Comfortable air conditioning by draft prevention and swing air blow.
Efficient air conditioning based on the room layout.
Twist-blade fan
Reduce sound level by decreasing spiral airflow!
* from previous model
22
% up!
About
Comf
ortable!
- 4 -
CASSETTE TYPE
AUXG18-54LRLB
Economy operation
Limits the maximum operation current, and the power consumption is cut down and the maxi­mum load is suppressed.
Improvement of installation and maintenance
High lift drain pump
Easy installation
Easy setting by wired remote controller.
Time
Economy operation
Normal operation
Setting
temperature
850 mm
Ceiling panel
- 5 -
CASSETTE TYPE
AUXG18-54LRLB
2. Wired remote controller
2-1. Features
High performance and compact size
In addition to the individual control, various energy saving controls can be realized using 1 re­mote controller only.
Accurate and comfortable control
Indoor temperature can be detected accurately by the room temperature sensor built in the wired remote controller.
• Easy finger touch operation with LCD panel
• Built-in weekly/daily timer (on/off, temperature and mode)
• The backlit LCD enables easy operation in a dark room.
• Room temperature display
• Control up to 16 indoor units
• Corresponds to 12 different languages (English, Chinese French, German, Spanish, Russian, Polish, Italian, Portu­guese, Greek, Turkish, and Dutch)
Individual
control
Thermo
sensor
Weekly
timer
Auto off
timer
Room temperature sensor Room temperature display
- 6 -
CASSETTE TYPE
AUXG18-54LRLB
Various energy saving control
Auto-off timer – The indoor unit automatically turns off after the set time has passed. – The time interval for which auto-off works can be set.
2 schedules weekly timer – 2 schedules such as for the summer and winter can be set. – 8 setting changeable per day of week (Setting items: on/off, temperature, mode, and time)
Set temperature auto return – The setting temperature automatically returns to the previous setting temperature. – The time range in which the set temperature can be changed is 10 to 120 minutes.
Set temperature upper and lower limit setting
The set temperature range can be set for each operation mode (COOL, HEAT, and AUTO).
Set interval time hour (17:00 to 24:00)
Set off time
(30 to 240 minutes)
17 4200 :00
On Auto-off
Off
Example: At interval time hour (17:00 to 24:00) to prevent forgetting to turn off.
Schedule 1 (Summer schedule) Schedule 2 (Winter schedule)
26 °C
24 °C
On
8:40 11:40 17:30 20:40
Off Off Off Off
Time
25 °C
23 °C
On
Setting temp.
Setting temp.
Setting example:
8:40 10:00 17:3015:30 20:40
Time
Setting temp.
Setting temp.
Cooling operation
24 °C
22 °C
Set temperature change Auto return
11:40 13:40
Time
Settable time range
10 to 120 minutes
Heating operation
25 °C
23 °C
Set temperature change Auto return
11:40 13:40
Time
Settable time range
10 to 120 minutes
Original temp.
setting range
Lower limit
setting
During cooling
30 °C
25 °C
18 °C
Original temp.
setting range
Upper limit
setting
During heating
30 °C
25 °C
16 °C
- 7 -
CASSETTE TYPE
AUXG18-54LRLB
Various convenient functions
Displays setting status and limitations
Summer time display
Child safety lock
Simplified installation
Easy maintenance
The remote controller settings can be easily checked.
Can be set easily from “Menu” screen.
Lock/unlock procedure: While touching the blank field on “Monitor” screen, push the on/off button for 4 seconds.
Use of non-polar 2-wire type
Faulty wiring can be prevented by using non-polar 2-wire.
Error history display
• Errors occur on the indoor unit or the remote controller are saved as a history.
• Maximum of 32-error incidents can be saved.
• Under Maintenance
• Forced Stop
• Mode Mismatch
Previous Page
Status
R.C. Prohibition
Special State
Page 2/ 4
Monitor
Next Page
• Op. Controlled
• Set Temp. Limited
• Energy Saving Operation
• Defrost
• Oil Recovery
Status
Special Srate
Page 3/ 4
Monitor
Previous Page
Next Page
• Human Sensor Setting
• Fan Control for Energy Saving
Status
Special Srate
Page 4/ 4
Monitor
Previous Page
Status
Air Flow Direction
VT
Off
1
Economy
Individual
Page 1/ 4
Monitor
Next Page
OK OK
non-polar 2-wire
Y1
Y2
Y1
Y2
I.U. I.U.
Y1Y2Y3 Y1Y2Y3
- 8 -
CASSETTE TYPE
AUXG18-54LRLB
Backlit LCD
System diagram
NOTE: Multiple installation method described above is prohibited to combine with 2-wired type and 3-wired type.
Group control
With a single remote controller, up to 16 units can be simultaneously operated.
A, B, C, D, E : Remote controller cable. (Refer to Chapter 2-4. "Wiring specifications" on page
10.) A+B+C+D+E 500 m.
!
CAUTION
Group control is only possible between units with remote controllers of the same type. After confirming that the connected remote controllers have same model name by checking
the rear side of the remote controller or “Chapter 13-1. "Controllers" on page 77”, perform the group control.
• The backlit LCD enables easy operation in a dark room.
• Backlighting time can be selected from 30 or 60 seconds.
• The backlight is lit while the buttons are operated, and goes off 30 or 60 seconds after the operation stops.
1 remote controller 2 remote controllers
A, B, C: Remote controller cable
A 500 m; B+C 500 m
A
Indoor unit
Remote controller
Master
Slave
BC
Indoor unit
Remote controllers
A
BCDE
I.U. I.U. I.U. I.U.
Master
I.U.: Indoor Unit
- 9 -
CASSETTE TYPE
AUXG18-54LRLB
2-2. Overview
Display panel
a Remote temperature sensor (inside)
b On/off button
Operable only while displaying the “Monitor mode” screen.
c LED lamp (operation indicator)
d Touch panel display
e Set temperature
Operating temperature can be set.
f Remote controller group name
g Mode
Operation mode can be set.
h Status icons
i Clock
j Fan
Fan speed can be set.
k Room temperature
l Menu
Various settings can be set.
m Status
Status of the indoor unit and error can be checked.
NOTE: Functions may differ by type of the indoor unit.
For details, refer to the operation manual.
abcd
26.0
26.0
°C
°C
Cool
Auto
Office 01
Set Temp.
26.0°C
26.0°C
Mode
MenuStatus
Fan
Fri 10:00AM
Room Temp.
e
f
h
h
g
h
i
j
l
m
k
- 10 -
CASSETTE TYPE
AUXG18-54LRLB
2-3. Specifications
Dimensions and other specifications on the wired remote controller are as follows.
2-4. Wiring specifications
NOTE: Use shielded cable (locally purchased) in accordance with the regional cable standard.
Display 3.8-inch FSTN LCD (255 × 160 dots) with touch panel Dimensions (H × W × D) mm 120 × 120 × 20.4 Weight g 220 Input voltage V DC 12 Power consumption W Max. 0.3 Usage temperature range °C 0 to 40 Usage humidity range % 20 to 90 (no condensation) Storage temperature range °C -10 to 60 Storage humidity range % 20 to 90 (no condensation)
Use Cable size Wire type Remarks
Remote controller cable
0.33 to 1.25 mm
2
Non-polar 2-core Use sheathed PVC cable.
20.4120
120
[Unit:mm]
- 11 -
CASSETTE TYPE
AUXG18-54LRLB
3. Specifications
3-1. Models: AUXG18LRLB and AUXG24LRLB
Typ e
Cassette
Inverter heat pump
Model name AUXG18LRLB AUXG24LRLB
Power supply 230 V ~ 50 Hz
Available voltage range 198—264 V
Capacity
Cooling
Rated
kW 5.2 6.8
Btu/h 17,700 23,200
Min.—Max.
kW 0.90—6.50 0.90—8.00
Btu/h 3,100—22,200 3,100—27,300
Heating
Rated
kW 6.0 7.8
Btu/h 20,500 26,600
Min.—Max.
kW 0.90—8.00 0.90—9.10
Btu/h 3,100—27,300 3,100—31,000
Input power
Cooling
Rated
kW
1.42 2,16
Max. 2.28 3.08
Heating
Rated 1.50 2.18
Max. 3.08 4.22
Fan
HIGH
W
16 21
MED 12 16
LOW 11 13
QUIET 79
Current
Cooling
Rated A
6.2 9.5
Heating 6.6 9.6
Power factor
Cooling
%
99.6 98.9
Heating 98.8 98.7
EER Cooling
kW/kW
3.66 3.15
COP Heating 4.00 3.58
Moisture removal L/h (pints/h) 2.2 (3.9) 2.7 (4.8)
Maximum operating current *1
Cooling
A
10.0 13.5
Heating 13.5 18.5
Fan
Airflow rate
Cooling
HIGH
m3/h
1,050 1,150
MED 960 1,050
LOW 900 980
QUIET 780 870
Heating
HIGH 1,050 1,150
MED 960 1,050
LOW 900 980
QUIET 780 870
Type × Q'ty Turbo fan × 1
Motor output W 81
Sound pressure level *2
Cooling
HIGH
dB (A)
33 35
MED 32 33
LOW 31 32
QUIET 28 29
Heating
HIGH 33 35
MED 32 33
LOW 31 32
QUIET 28 29
Sound power level
Cooling
HIGH dB (A)
47 49
Heating 47 49
Heat exchanger type
Dimensions (H × W × D)
mm
210 × 2,127 × 13.3 210 × 2,061 × 13.3
Fin pitch 1.2
Rows × Stages 2 × 10
Pipe type Copper tube
Fin type Aluminum
Dimensions (H × W × D)
Net
mm
246 × 840 × 840
Gross 298 × 960 × 950
Weight
Net
kg
24
Gross 29
Connection pipe
Size
Liquid
mm (in)
Ø 6.35 (Ø 1/4)
Gas Ø 12.70 (Ø 1/2) Ø 15.88 (Ø 5/8)
Method Flare
Drain hose
Material PVC(VP25)
Size mm Ø 25 (I.D.), Ø 32 (O.D .)
Operation range
Cooling
°C 18 to 32
%RH 80 or less
Heating °C 16 to 30
Cassette grille
Material PS
Color
White
Approximate color of MUNSELL N 9.25/
Dimensions (H × W × D)
Net
mm
53 × 950 × 950
Gross 110 × 1,000 × 1,010
Weight
Net
kg
6.0
Gross 10.5
- 12 -
CASSETTE TYPE
AUXG18-54LRLB
Remote controller type Wired (Wireless [option])
NOTES:
Specifications are based on the following conditions:
–Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB. –Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB. –Pipe length: 5 m, Height difference: 0 m. (Between outdoor unit and indoor unit.)
Protective function might work when using it outside the operation range.*1: Maximum current:
–The maximum value when operated within the operation range. –The total current of indoor unit and outdoor unit.
*2: Sound pressure level:
–Measured values in manufacturer’s anechoic chamber. –Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
Model name AUXG18LRLB AUXG24LRLB
Energy efficiency class
Cooling
A
++
A
++
Heating (Average)
A
+
A
+
Pdesign
Cooling
kW
5.2 (35°C) 6.8 (35°C)
Heating (Average) 4.3 (-10°C) 6.0 (-10°C)
SEER Cooling
kWh/kWh
7.05 6.60
SCOP Heating ( Average) 4.40 4.20
Annual energy consumption
QCE
kWh/a
258 361
QHE (Average) 1,367 1,999
Sound power level
Cooling
HIGH dB (A)
47 49
Heating 47 49
Typ e
Cassette
Inverter heat pump
Model name AUXG18LRLB AUXG24LRLB
- 13 -
CASSETTE TYPE
AUXG18-54LRLB
3-2. Models: AUXG30LRLB, AUXG36LRLB, AUXG45LRLB, and
AUXG54LRLB
Typ e
Cassette
Inverter heat pump
Model name AUXG30LRLB AUXG36LRLB AUXG45LRLB AUXG54LRLB
Power supply 230 V ~ 50 Hz
Available voltage range 198—264 V
Capacity
Cooling
Rated
kW 8.5 9.5 12.5 13.3
Btu/h 29,000 32,400 42,700 45,400
Min.—Max.
kW 2.8—10.0 2.8—11.2 4.0—14.0 4.5—14.5
Btu/h 9,500—34,100 9,500—38,200 13,700—47,800 21,200—49,500
Heating
Rated
kW 10 .0 10.8 14. 0 15.8
Btu/h 34,100 36,900 47,800 53,900
Min.—Max.
kW 2.70—11.20 2.7—12.7 4.2—16.2 4.7—16.5
Btu/h 9,200—38,200 9,200—43,300 14,300—55,300 16,000—56,300
Input power
Cooling
Rated
kW
2.56 2. 96 3.85 4.3 8
Max. 3.88 4.56 4.70 4.94
Heating
Rated 2.77 2.91 3.73 4.58
Max. 3.88 4.56 4.70 4.94
Fan
HIGH
W
52 87 106 129
MED 39526095
LOW 31394555
QUIET 20233034
Current
Cooling
Rated A
11.2 13.0 16.8 19.1
Heating 12.212.716.320.0
Power factor
Cooling
%
99.4 99 .0 99.6 99 .2
Heating 98.799.699.599.6
EER Cooling
kW/kW
3.32 3. 21 3.25 3.0 4
COP Heating 3.61 3.71 3.75 3.45
Moisture removal L/h (pints/h) 2.5 (4.4) 3.3 (5.8) 4.5 (7.9) 5.0 (8.8)
Maximum operating current *1
Cooling
A
17.0 20 .0 20.5 21 .5
Heating 17.0 20.0 20.5 21.5
Fan
Airflow rate
Cooling
HIGH
m3/h
1,600 1,900 2,000 2,100
MED 1,400 1,590 1,650 1,780
LOW 1,270 1,420 1,460 1,600
QUIET 1,150 1,180 1,300 1,320
Heating
HIGH 1,600 1,900 2,000 2,100
MED 1,400 1,590 1,650 1,780
LOW 1,270 1,420 1,460 1,600
QUIET 1,150 1,180 1,300 1,320
Type × Q'ty Turbo fan × 1
Motor output W 81
Sound pressure level *2
Cooling
HIGH
dB (A)
40 44 46 47
MED 38414243
LOW 36383940
QUIET 33343536
Heating
HIGH 40 44 46 47
MED 38414243
LOW 36383940
QUIET 33343536
Sound power level
Cooling
HIGH dB (A)
54 58 60 61
Heating 54586061
Heat exchanger type
Dimensions (H × W × D)
mm
252 × 2,124 × 13.3 252 × 2,062 × 13.3
252 × 2,124 × 13.3 252 × 2,062 × 13.3 252 × 1,999 × 13.3
Fin pitch 1.2 1.3
Rows × Stages 2 × 12 3 × 12
Pipe type Copper tube
Fin type Aluminum
Dimensions (H × W × D)
Net
mm
288 × 840 × 840
Gross 350 × 960 × 950
Weight
Net
kg
26 29
Gross 32 34
Connection pipe
Size
Liquid
mm (in)
Ø 9.52 (Ø 3/8)
Gas Ø 15.88 (Ø 5/8)
Method Brazing
Drain hose
Material PVC(VP25)
Size mm Ø 25 (I.D.), Ø 32 (O.D.)
Operation range
Cooling
°C 18 to 32
%RH 80 or less
Heating °C 16 to 30
Cassette grille
Material PS
Color
White
Approximate color of MUNSELL N 9.25/
Dimensions (H × W × D)
Net
mm
53 × 950 × 950
Gross 110 × 1,000 × 1,010
Weight
Net
kg
6.0
Gross 10.5
- 14 -
CASSETTE TYPE
AUXG18-54LRLB
Remote controller type Wired (Wireless [option])
NOTES:
Specifications are based on the following conditions:
–Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB. –Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB. –Pipe length: 5 m, Height difference: 0 m. (Between outdoor unit and indoor unit.)
Protective function might work when using it outside the operation range.*1: Maximum current:
–The maximum value when operated within the operation range. –The total current of indoor unit and outdoor unit.
*2: Sound pressure level:
–Measured values in manufacturer’s anechoic chamber. –Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
Model name AUXG30LRLB AUXG36LRLB
Energy efficiency class
Cooling
A
++
A
++
Heating (Average)
A
+
A
+
Pdesign
Cooling
kW
8.5 (35°C) 9.5 (35°C)
Heating (Average) 8.0 (-10°C) 8.7 (-10°C)
SEER Cooling
kWh/kWh
6.70 6.40
SCOP Heating ( Average) 4.30 4.30
Annual energy consumption
QCE
kWh/a
444 519
QHE (Average) 2,604 2,833
Sound power level
Cooling
HIGH dB (A)
54 58
Heating 54 58
Typ e
Cassette
Inverter heat pump
Model name AUXG30LRLB AUXG36LRLB AUXG45LRLB AUXG54LRLB
- 15 -
CASSETTE TYPE
AUXG18-54LRLB
4. Dimensions
4-1. Models: AUXG18LRLB and AUXG24LRLB
Ceiling opening and hanging bolt pitch
Refrigerant piping and drain piping positions
246
256
40
10
140–145
50–100
950 (Panel frame)
20–45 20–45
50
80
130
130
130
200
840 (Body frame)
796 (Hanging bolt pitch)
768 (Hanging bolt pitch)
860–910 (Ceiling opening)
950 (Panel frame)
840 (Body frame)
860–910 (Ceiling opening)
20–4520–45
Unit: mm
45
293342
140
180
200
Drain pipe (Connect the attached drain hose)
Unit: mm
- 16 -
CASSETTE TYPE
AUXG18-54LRLB
Airflow split-flow duct and fresh-air inlet positions
114
95
3.2 hole
3.2 hole
280
352
100
83
83
90
100
163
163
Airflow split-flow duct connecting port
Airflow split-flow duct connecting port
Airflow split-flow duct connecting port
Fresh air inlet position
Fresh air inlet position
Drain pipe
Refrigerant pipe
Detailed diagram of branched duct connecting port (4 sides)
Knockout hole pitch
Cut out
Cut out
Airflow split-flow duct connecting port
10
4
Unit: mm
- 17 -
CASSETTE TYPE
AUXG18-54LRLB
4-2. Models: AUXG30LRLB, AUXG36LRLB, AUXG45LRLB, and
AUXG54LRLB
Ceiling opening and hanging bolt pitch
Refrigerant piping and drain piping positions
288
298
40
10
200–205
50–100
950 (Panel frame)
20–45 20–45
50
80
130
130
130
200
840 (Body frame)
796 (Hanging bolt pitch)
768 (Hanging bolt pitch)
860–910 (Ceiling opening)
950 (Panel frame)
840 (Body frame)
860–910 (Ceiling opening)
20–4520–45
Unit: mm
45
293342
140
180
200
Drain pipe (Connect the attached drain hose)
Unit: mm
- 18 -
CASSETTE TYPE
AUXG18-54LRLB
Airflow split-flow duct and fresh-air inlet positions
114
95
3.2 hole
3.2 hole
280
352
100
83
83
90
100
163
163
Airflow split-flow duct connecting port
Airflow split-flow duct connecting port
Airflow split-flow duct connecting port
Fresh air inlet position
Fresh air inlet position
Drain pipe
Refrigerant pipe
Detailed diagram of branched duct connecting port (4 sides)
Knockout hole pitch
Cut out
Cut out
Airflow split-flow duct connecting port
10
4
Unit: mm
- 19 -
CASSETTE TYPE
AUXG18-54LRLB
4-3. Installation space requirement
Provide sufficient installation space for product safety.
For 4-direction setting (AUXG18LRLB and AUXG24LRLB):
*: For the details of position adjustment by ceiling mode, refer to “Contents of function setting” on page 69.
For 4-direction setting (AUXG30LRLB, AUXG36LRLB, AUXG45LRLB, and AUXG54LRLB):
*: For the details of position adjustment by ceiling mode, refer to “Contents of function setting” on page 69.
1,500
or more
1,000 or more
1,800 or more
Obstruction
3,000 or more
Strong and durable ceiling
Floor
Ceiling height
Ceiling mode* “Low” : 2.7 m
Ceiling mode “Standard” : 3.0 m
Ceiling mode “High” : 3.5 m
256 or more
Unit: mm
1,500
or more
1,000 or more
1,800 or more
Obstruction
3,000 or more
Strong and durable ceiling
Floor
Ceiling height
Ceiling mode* “Low” : 2.7 m
Ceiling mode “Standard” : 3.2 m
Ceiling mode “High” : 4.2 m
298 or more
Unit: mm
- 20 -
CASSETTE TYPE
AUXG18-54LRLB
For 3-direction setting:
NOTES:
• To set “3-direction”, optional Air outlet shutter plate (UTR-YDZK) must be installed, and the “outlet-direction” need to be switched to “3-way” by remote controller.
• The ceiling height cannot be set in the 3-way outlet mode. Therefore, ceiling height setting change by function setting 20 is prohibited. For details, refer to “Contents of function setting” on page 69.
Human sensor(Option)
Example of sensitivity range: When the installation height gets higher, the temperature sensitivity decreases.
!
CAUTION
Do not place large objects near the human sensor. Also keep heating units outside the sensor’s detection area.
Equal sensitivity range of temperature
Ceiling height 3,200 mm
Detecting position 800 mm from floor surface
100 or more
Unit: mm
Drain
pipe
Refrigerant pipe
Human sensor
Top view
3,200
800
8,800
Unit: mm
- 21 -
CASSETTE TYPE
AUXG18-54LRLB
5. Wiring diagram
5-1. Models: AUXG18LRLB, AUXG24LRLB, AUXG30LRLB,
AUXG36LRLB, AUXG45LRLB, and AUXG54LRLB
- 22 -
CASSETTE TYPE
AUXG18-54LRLB
6. Capacity table
Capacity tables show each of following values calculated based on the outdoor temperature and the indoor temperature, under given Airflow Rate (AFR):
For cooling capacity: Total Capacity (TC), Sensible Heat Capacity (SHC), and Input Power (IP)
For heating capacity: Total Capacity (TC) and Input Power (IP)
6-1. Cooling capacity
NOTE: Values mentioned in the table are calculated based on the maximum capacity.
Model: AUXG18LRLB
Model: AUXG24LRLB
AFR
m3/h
1,050
Indoor temperature
°CDB 18 21 23 25 27 29 32
°CWB 12 15 16 18 19 21 23
Outdoor temperature
°CDB
TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP
kW kW kW kW kW kW kW
-15 4.88 4.10 0.25 5.44 4.11 0.25 5.63 4.47 0.25 6.00 4.48 0.26 6.19 4.85 0.26 6.55 4.83 0.26 6.92 5.14 0.26
-10 4.91 4.10 0.41 5.47 4.11 0.41 5.66 4.48 0.41 6.03 4.49 0.42 6.22 4.85 0.42 6.58 4.84 0.43 6.96 5.15 0.43
0 4.80 4.02 0.48 5.35 4.05 0.49 5.52 4.40 0.49 5.89 4.41 0.49 6.07 4.77 0.50 6.44 4.75 0.50 6.80 5.06 0.51
5 4.66 3.96 0.59 5.19 3.99 0.60 5.37 4.33 0.60 5.72 4.35 0.61 5.90 4.70 0.61 6.25 4.68 0.62 6.61 4.98 0.62
10 4.51 3.88 0.70 5.03 3.91 0.71 5.19 4.24 0.71 5.53 4.26 0.71 5.71 4.61 0.72 6.05 4.58 0.73 6.39 4.89 0.73
15 4.52 3.89 0.61 5.04 3.92 0.62 5.20 4.26 0.62 5.56 4.27 0.63 5.72 4.62 0.63 6.06 4.59 0.64 6.42 4.89 0.65
20 5.69 4.18 1.29 6.33 4.21 1.31 6.55 4.58 1.32 6.98 4.59 1.33 7.20 4.96 1.34 7.63 4.93 1.35 8.06 5.25 1.36
25 5.45 4.17 1.44 6.07 4.19 1.47 6.28 4.57 1.47 6.69 4.58 1.49 6.90 4.94 1.49 7.31 4.92 1.50 7.73 5.24 1.52
30 5.20 4.15 1.59 5.80 4.18 1.62 6.00 4.54 1.63 6.38 4.55 1.65 6.58 4.92 1.65 6.98 4.89 1.66 7.38 5.21 1.68
35 5.14 4.14 1.86 5.72 4.17 1.89 5.92 4.53 1.90 6.31 4.54 1.92 6.50 4.90 1.92 6.89 4.88 1.92 7.29 5.20 1.92
40 3.76 3.44 1.28 4.19 3.47 1.30 4.33 3.76 1.30 4.61 3.77 1.31 4.75 4.08 1.32 5.04 4.07 1.33 5.33 4.33 1.35
46 2.67 2.93 0.95 2.97 2.96 0.97 3.08 3.22 0.97 3.29 3.22 0.98 3.39 3.48 0.99 3.59 3.47 1.00 3.79 3.69 1.01
AFR
m3/h
1,150
Indoor temperature
°CDB 18 21 23 25 27 29 32
°CWB 12 15 16 18 19 21 23
Outdoor temperature
°CDB
TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP
kW kW kW kW kW kW kW
-15 5.59 4.51 0.36 6.23 4.53 0.36 6.44 4.93 0.37 6.86 4.94 0.37 7.07 5.34 0.38 7.50 5.32 0.38 7.92 5.67 0.38
-10 5.62 4.52 0.60 6.26 4.54 0.60 6.47 4.94 0.61 6.90 4.95 0.61 7.11 5.35 0.62 7.54 5.33 0.62 7.96 5.68 0.63
0 5.52 4.47 0.64 6.15 4.49 0.65 6.36 4.89 0.66 6.78 4.90 0.66 6.99 5.29 0.67 7.41 5.27 0.67 7.83 5.62 0.68
5 5.33 4.37 0.78 5.94 4.40 0.79 6.14 4.78 0.80 6.55 4.80 0.80 6.75 5.18 0.81 7.15 5.16 0.82 7.56 5.50 0.82
10 5.12 4.26 0.91 5.71 4.29 0.92 5.90 4.66 0.93 6.29 4.68 0.94 6.49 5.05 0.94 6.87 5.03 0.95 7.26 5.36 0.96
15 5.25 4.33 0.76 5.85 4.35 0.77 6.05 4.73 0.78 6.45 4.75 0.79 6.65 5.13 0.79 7.05 5.11 0.80 7.44 5.44 0.81
20 6.75 5.11 1.65 7.52 5.15 1.67 7.77 5.59 1.68 8.29 5.61 1.70 8.54 6.06 1.71 9.05 6.04 1.73 9.57 6.43 1.74
25 6.41 4.93 1.78 7.14 4.96 1.81 7.38 5.39 1.82 7.87 5.41 1.84 8.11 5.84 1.85 8.60 5.82 1.86 9.08 6.20 1.88
30 6.07 4.75 1.98 6.76 4.78 2.01 6.99 5.20 2.02 7.46 5.22 2.04 7.69 5.63 2.05 8.15 5.61 2.07 8.61 5.98 2.09
35 6.32 4.88 2.52 7.04 4.91 2.56 7.28 5.34 2.57 7.76 5.36 2.60 8.00 5.79 2.61 8.48 5.76 2.64 8.96 6.14 2.66
40 5.22 4.31 2.10 5.81 4.34 2.14 6.01 4.72 2.15 6.41 4.73 2.17 6.61 5.11 2.18 7.00 5.09 2.20 7.40 5.42 2.22
46 3.74 3.58 1.59 4.17 3.60 1.61 4.31 3.91 1.62 4.60 3.92 1.64 4.74 4.24 1.65 5.02 4.22 1.66 5.31 4.50 1.68
- 23 -
CASSETTE TYPE
AUXG18-54LRLB
Model: AUXG30LRLB
Model: AUXG36LRLB
Model: AUXG45LRLB
AFR
m3/h
1,600
Indoor temperature
°CDB 18 21 23 25 27 29 32
°CWB 12 15 16 18 19 21 23
Outdoor temperature
°CDB
TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP
kW kW kW kW kW kW kW
-15 8.67 6.58 1.20 9.66 6.62 1.22 9.99 7.20 1.22 10.65 7.22 1.22 10.98 7.80 1.24 11.64 7.77 1.25 12.29 8.27 1.27
-10 8.52 6.38 1.64 9.49 6.42 1.66 9.81 6.98 1.67 10.46 7.00 1.69 10.79 7.56 1.70 11.44 7.53 1.72 12.08 8.02 1.73
0 8.12 6.26 2.11 9.04 6.30 2.15 9.35 6.85 2.16 9.97 6.87 2.18 10.28 7.42 2.19 10.90 7.39 2.21 11.51 7.87 2.23
5 7.99 6.11 2.14 8.90 6.14 2.17 9.21 6.68 2.19 9.81 6.70 2.21 10.12 7.23 2.22 10.73 7.20 2.24 11.33 7.68 2.26
10 7.96 6.19 2.19 8.87 6.23 2.23 9.17 6.77 2.24 9.77 6.79 2.26 10.07 7.34 2.27 10.67 7.31 2.29 11.28 7.79 2.32
15 8.63 6.48 2.41 9.62 6.52 2.45 9.95 7.09 2.46 10.60 7.11 2.49 10.93 7.68 2.50 11.59 7.65 2.53 12.24 8.14 2.55
20 9.82 7.03 2.97 10.94 7.07 3.01 11.31 7.69 3.03 12.06 7.71 3.06 12.43 8.33 3.08 13.18 8.30 3.11 13.92 8.84 3.14
25 9.48 6.89 3.31 10.56 6.93 3.36 10.92 7.53 3.38 11.64 7.56 3.41 12.00 8.16 3.43 12.72 8.13 3.46 13.44 8.66 3.50
30 8.81 6.70 3.35 9.81 6.74 3.39 10.15 7.32 3.41 10.81 7.35 3.44 11.15 7.93 3.46 11.82 7.90 3.50 12.49 8.42 3.53
35 7.90 6.12 3.35 8.80 6.16 3.40 9.10 6.69 3.42 9.70 6.71 3.45 10.00 7.25 3.47 10.60 7.22 3.51 11.20 7.69 3.54
40 6.16 5.13 2.94 6.86 5.16 2.99 7.09 5.61 3.00 7.56 5.63 3.04 7.80 6.08 3.05 8.27 6.06 3.08 8.73 6.45 3.11
46 5.44 4.92 2.91 6.06 4.95 2.96 6.27 5.39 2.97 6.68 5.40 3.00 6.89 5.83 3.02 7.30 5.81 3.05 7.71 6.19 3.08
AFR
m3/h
1,900
Indoor temperature
°CDB 18 21 23 25 27 29 32
°CWB 12 15 16 18 19 21 23
Outdoor temperature
°CDB
TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP
kW kW kW kW kW kW kW
-15 9.33 7.37 1.29 10.39 7.41 1.31 10.74 8.06 1.32 11.45 8.08 1.33 11.80 8.73 1.34 12.51 8.70 1.35 13.22 9.26 1.36
-10 9.22 7.23 1.69 10.27 7.27 1.71 10.62 7.90 1.72 11.32 7.93 1.74 11.67 8.56 1.75 12.37 8.53 1.77 13.07 9.08 1.78
0 8.77 7.13 2.18 9.77 7.17 2.22 10.10 7.80 2.23 10.77 7.82 2.25 11.10 8.45 2.26 11.77 8.41 2.29 12.44 8.96 2.31
5 8.69 6.98 2.25 9.68 7.02 2.28 10.01 7.64 2.29 10.67 7.66 2.32 11.00 8.27 2.33 11.66 8.24 2.35 12.32 8.78 2.38
10 8.62 7.06 2.25 9.60 7.10 2.29 9.93 7.72 2.30 10.58 7.75 2.32 10.91 8.37 2.34 11.56 8.33 2.36 12.22 8.88 2.38
15 9.17 7.17 2.42 10.21 7.22 2.46 10.56 7.85 2.47 11.25 7.87 2.50 11.60 8.50 2.51 12.30 8.47 2.54 13.00 9.02 2.56
20 10.70 7.92 2.99 11.92 7.97 3.03 12.33 8.66 3.05 13.14 8.69 3.08 13.54 9.39 3.10 14.36 9.35 3.13 15.17 9.96 3.16
25 10.64 8.02 3.32 11.86 8.06 3.38 12.26 8.77 3.39 13.07 8.79 3.43 13.47 9.50 3.45 14.28 9.46 3.48 15.09 10.08 3.51
30 10.24 7.76 4.05 11.40 7.81 4.11 11.79 8.49 4.13 12.57 8.51 4.17 12.96 9.19 4.19 13.73 9.16 4.24 14.51 9.75 4.28
35 8.85 6.78 4.03 9.86 6.82 4.10 10.19 7.42 4.12 10.86 7.44 4.16 11.20 8.04 4.18 11.87 8.01 4.22 12.54 8.53 4.27
40 6.80 5.96 3.09 7.58 6.00 3.14 7.84 6.52 3.16 8.35 6.54 3.19 8.61 7.07 3.20 9.13 7.04 3.24 9.65 7.50 3.27
46 6.11 5.84 2.96 6.81 5.87 3.01 7.04 6.39 3.02 7.50 6.41 3.05 7.74 6.92 3.07 8.20 6.89 3.10 8.67 7.34 3.13
AFR
m3/h
2,000
Indoor temperature
°CDB 18 21 23 25 27 29 32
°CWB 12 15 16 18 19 21 23
Outdoor temperature
°CDB
TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP
kW kW kW kW kW kW kW
-15 11.34 8.71 2.56 12.63 8.76 2.60 13.06 9.52 2.62 13.92 9.55 2.64 14.35 10.32 2.66 15.21 10.28 2.68 16.07 10.95 2.71
-10 11.44 8.70 2.46 12.74 8.75 2.50 13.17 9.51 2.51 14.04 9.55 2.54 14.48 10.31 2.55 15.35 10.27 2.58 16.21 10.94 2.60
0 11.55 8.77 2.23 12.87 8.83 2.26 13.31 9.60 2.28 14.18 9.63 2.30 14.62 10.40 2.31 15.50 10.35 2.33 16.38 11.03 2.36
5 11.37 8.78 2.30 12.67 8.84 2.34 13.10 9.61 2.35 13.97 9.64 2.37 14.40 10.41 2.39 15.26 10.37 2.41 16.12 11.04 2.43
10 11.11 8.78 2.49 12.37 8.83 2.53 12.79 9.60 2.54 13.64 9.63 2.57 14.06 10.40 2.58 14.90 10.36 2.61 15.74 11.04 2.63
15 10.84 8.68 2.69 12.07 8.74 2.73 12.48 9.50 2.74 13.31 9.53 2.77 13.72 10.29 2.78 14.54 10.25 2.81 15.37 10.92 2.84
20 11.22 8.69 3.15 12.49 8.74 3.20 12.92 9.50 3.22 13.77 9.53 3.25 14.20 10.29 3.27 15.05 10.25 3.30 15.90 10.92 3.33
25 11.10 8.78 3.36 12.36 8.83 3.41 12.79 9.60 3.43 13.63 9.63 3.46 14.05 10.40 3.48 14.89 10.36 3.51 15.74 11.03 3.55
30 11.34 8.84 4.27 12.63 8.89 4.34 13.06 9.67 4.36 13.92 9.70 4.41 14.35 10.48 4.43 15.21 10.43 4.43 16.07 11.11 4.43
35 11.06 8.82 4.53 12.32 8.87 4.60 12.74 9.64 4.62 13.58 9.68 4.67 14.00 10.45 4.69 14.84 10.41 4.69 15.68 11.09 4.69
40 8.79 7.66 3.92 9.79 7.83 3.98 10.13 8.52 4.00 10.80 8.54 4.04 11.13 9.23 4.06 11.80 9.19 4.06 12.47 9.79 4.06
46 6.69 6.63 3.24 7.45 6.87 3.29 7.71 7.47 3.31 8.22 7.49 3.34 8.47 8.09 3.36 8.98 8.06 3.36 9.49 8.58 3.36
- 24 -
CASSETTE TYPE
AUXG18-54LRLB
Model: AUXG54LRLB
AFR
m3/h
2,100
Indoor temperature
°CDB 18 21 23 25 27 29 32
°CWB 12 15 16 18 19 21 23
Outdoor temperature
°CDB
TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP
kW kW kW kW kW kW kW
-15 11.73 9.03 2.69 13.07 9.08 2.73 13.52 9.87 2.75 14.41 9.90 2.78 14.85 10.69 2.79 15.74 10.65 2.82 16.64 11.35 2.85
-10 11.72 9.04 2.59 13.06 9.10 2.63 13.50 9.89 2.64 14.39 9.92 2.67 14.84 10.71 2.68 15.73 10.67 2.71 16.62 11.37 2.73
0 11.84 9.12 2.33 13.19 9.17 2.36 13.64 9.97 2.37 14.54 10.01 2.40 14.99 10.81 2.41 15.89 10.76 2.43 16.78 11.46 2.46
5 11.60 8.96 2.42 12.92 9.02 2.46 13.37 9.80 2.47 14.25 9.83 2.50 14.69 10.62 2.51 15.57 10.58 2.54 16.45 11.27 2.56
10 11.44 8.90 2.54 12.74 8.95 2.58 13.18 9.73 2.59 14.04 9.76 2.62 14.48 10.54 2.63 15.35 10.50 2.66 16.22 11.18 2.68
15 11.22 8.99 2.81 12.50 9.04 2.85 12.92 9.83 2.86 13.77 9.86 2.89 14.20 10.65 2.91 15.05 10.61 2.93 15.90 11.30 2.96
20 12.06 9.55 3.73 13.43 9.61 3.79 13.89 10.45 3.81 14.81 10.48 3.85 15.26 11.32 3.87 16.18 11.27 3.90 17.10 12.01 3.94
25 11.82 9.10 4.31 13.17 9.15 4.38 13.62 9.95 4.40 14.52 9.98 4.45 14.97 10.78 4.47 15.86 10.73 4.51 16.76 11.44 4.56
30 11.62 8.98 4.52 12.95 9.04 4.59 13.39 9.82 4.61 14.27 9.86 4.66 14.71 10.64 4.68 15.59 10.60 4.68 16.48 11.29 4.68
35 11.46 8.89 4.75 12.76 8.95 4.82 13.20 9.73 4.85 14.07 9.76 4.90 14.50 10.54 4.92 15.37 10.50 4.92 16.24 11.18 4.92
40 9.11 8.03 3.94 10.15 8.21 4.00 10.49 8.93 4.02 11.18 8.96 4.06 11.53 9.67 4.08 12.22 9.63 4.08 12.91 10.26 4.08
46 6.94 6.91 3.26 7.73 7.16 3.31 7.99 7.78 3.33 8.52 7.81 3.36 8.78 8.43 3.38 9.31 8.40 3.38 9.83 8.94 3.38
Loading...
+ 105 hidden pages