Fujitsu AST9QM, AOT30QMAM4, AST12QM Operating Manual

KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE
FUJITSU GENERAL LIMITED
P/N9372250013
HEAT & COOL MODEL (REVERSE CYCLE)
INDOOR UNIT
OUTDOOR UNIT
AOT30QMAM4
OPERATING MANUAL
ROOM AIR CONDITIONER
MULTI SPLIT TYPE
(4 ROOMS)
1
CONTENTS
SAFETY PRECAUTIONS .......................................... 1
FEATURES AND FUNCTIONS ................................. 2
NAME OF PARTS ...................................................... 3
PREPARATION .......................................................... 5
OPERATION .............................................................. 6
TIMER OPERATION .................................................. 8
SLEEP TIMER OPERATION ...................................... 9
ADJUSTING THE DIRECTION OF
AIR CIRCULATION .................................................. 10
SWING OPERATION ............................................... 11
MANUAL AUTO OPERATION ................................ 11
CLEANING AND CARE ........................................... 12
TROUBLESHOOTING ............................................. 14
OPERATING TIPS .................................................... 15
SPECIFICATIONS .................................................... 18
Do not attempt to install this air conditioner by yourself.
This unit contains no user-serviceable parts. Always consult authorized service per-
sonnel for repairs.
When moving, consult authorized service personnel for disconnection and installa­tion of the unit.
Do not become excessively chilled by staying for lengthy periods in the direct cooling airflow.
Do not insert fingers or objects into the outlet port or intake grilles.
Do not start and stop air conditioner operation by disconnecting the power supply
cord and so on.
Take care not to damage the power supply cord.
In the event of a malfunction (burning smell, etc.), immediately stop operation, turn
off the circuit breaker, and consult authorized service personnel.
If the power supply cord of this appliance is damaged, it should only be replaced by the authorized service personnel, since special purpose tools and specified cord are required.
Provide occasional ventilation during use.
Do not direct air flow at fireplaces or heating apparatus.
Do not climb on, or place objects on, the air conditioner.
Do not hang objects from the indoor unit.
Do not set flower vases or water containers on top of air conditioners.
Do not expose the air conditioner directly to water.
Do not operate the air conditioner with wet hands.
Do not pull power supply cord.
Turn off power source when not using the unit for extended periods.
Check the condition of the installation stand for damage.
Do not place animals or plants in the direct path of the air flow.
Do not drink the water drained from the air conditioner.
Do not use in applications involving the storage of foods, plants or animals, precision
equipment, or art works.
Connection valves become hot during Heating; handle with care.
Do not apply any heavy pressure to radiator fins.
Operate only with air filters installed.
Do not block or cover the intake grille and outlet port.
Ensure that any electronic equipment is at least one metre away from either the in-
door or outdoor units.
Avoid installing the air conditioner near a fireplace or other heating apparatus.
When installing the indoor and outdoor unit, take precautions to prevent access to
infants.
Do not use inflammable gases near the air conditioner.
DANGER!
CAUTION!
SAFETY PRECAUTIONS
Before using the appliance, read these “PRECAUTIONS” thoroughly and operate in the correct way.
The instructions in this section all relate to safety; be sure to maintain save operating conditions.
“DANGER”, “WARNING” and “CAUTION” have the following meanings in these instructions:
WARNING!
CAUTION!
This mark indicates procedures which, if improperly performed, are most likely to result in the death of or serious injury to the user or service personnel.
This mark indicates procedures which, if improperly performed, might lead to the death or serious injury of the user.
This mark indicates procedures which, if improperly performed, might possibly result in personal harm to the user, or damage to property.
DANGER!
2
FEATURES AND FUNCTIONS
AUTOMATIC OPERATION
Merely press the START/STOP button, and the unit will be­gin automatic operation in either the Heating, Cooling, Dry or Monitor modes as appropriate, in accordance with the thermostat setting and the actual temperature of the room.
SLEEP TIMER
When the SLEEP timer button is pressed during Heating mode, the air conditioner’s thermostat setting is gradually lowered during the period of operation; during Cooling mode, the thermostat setting is gradually raised during the period of operation. When the set time is reached, the unit automatically turns off.
WIRELESS REMOTE CONTROL UNIT
The WIRELESS REMOTE CONTROL UNIT allows convenient control of air conditioner operation.
SWING OPERATION
The Air Flow Direction Louvers swings automatically up and down so that the air speeds to every nook and corner of your room.
REMOVABLE INTAKE GRILLE
The indoor unit’s INTAKE GRILLE can be removed for easy cleaning and maintenance.
MILDEW-RESISTANT FILTER
The AIR FILTER has been treated to resist mildew growth, thus allowing cleaner use and easier care.
SUPER QUIET OPERATION
When the FAN CONTROL button is used to select QUIET, the unit begins super-quiet operation; the indoor unit’s air­flow is reduced for quieter operation.
AIR CLEANING FILTER (Optional)
The optional Air Cleaning Filter (Model APS-02F) uses an electrostatic principle to clean the air of fine particulate matter such as tobacco smoke and plant pollen.
3
NAME OF PARTS
Fig. 5
Fig. 6
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 8
To facilitate explanation, the accompanying illustra­tion has been drawn to show all possible indicators; in actual operation, however, the display will only show those indicators appropriate to the current op­eration.
Fig. 7
4
Fig. 6 Remote Control Unit
H SLEEP button I MASTER CONTROL button J SET TEMP./SET TIME buttons (
)
K Signal Transmitter L TIMER button M FAN CONTROL button N START/STOP button O AIR FLOW DIRECTION button P SWING LOUVER button
Rear side (Fig. 7)
Q TIME ADJUST button R ACL button
(located inside battery compartment)
S TEST RUN button
This button is used when installing the conditioner, and should not be used un­der normal conditions, as it will cause the air conditioners thermostat function to op­erate incorrectly.
If this button is pressed during normal op­eration, the unit will switch to test opera­tion mode, and the Indoor Units OPERA­TION Indicator Lamp and TIMER Indicator Lamp will begin to flash simultaneously.
To stop the test operation mode, either press the TEST RUN button once again, or press the START/STOP button to stop the air conditioner.
T Remote Control Unit Display (Fig. 8) U Transmit Indicator V Clock Display W Operating Mode Display X T imer Mode Display Y Fan Speed Display Z Temperature Set Display [ T imer Set Indicator \ Temperature Set Indicator
Fig. 1 Indoor Unit
1 Operating Control Panel (Fig. 2) 2 POWER Switch 3 MANUAL AUTO button
4 Remote Control Signal Receiver
5 Indicator Lamps (Fig. 3) 6 OPERATION Indicator Lamp (red)
Lights when unit is operating.
The lamp will flash slowly (3 seconds on,
1 second off) when the defrosting opera­tion (See page 15).
The lamp will flash quickly (1 second on, 1
second off) when the selected operating mode can not be used (See page 17).
7 TIMER Indicator Lamp (green)
If the TIMER indicator lamp flashes when the timer is operating, it indicates that a fault has occurred with the timer setting (see page 16 Auto Restart).
8 SWING Indicator Lamp (orange)
9 Intake Grille (Fig. 4) 0 Air Filter A Air Flow Direction Louver B Right-Left Louvers
(behind Air Flow Direction Louver)
C Drain Hose D Air Cleaning Filter (optional)
Fig. 5 Outdoor Unit
E Intake Port F Outlet Port G Pipe Unit
5
Turn on the Power
1
Turn on the circuit breaker.
2
Set the POWER switch (Fig. 2 2) to ON.
Load Batteries (R03/LR03
××
××
× 2)
1
Press and slide the battery compartment lid on the re­verse side to open it.
Slide in the direction of the arrow while pressing the mark.
2
Insert batteries.
Be sure to align the battery polarities ( ) correctly.
3
Close the battery compartment lid.
Set the Current time
1
Press the TIME ADJUST button (Fig. 7 Q).
Use the tip of a ball-point pen or other small object to press the button.
2
Use the SET TIME buttons (Fig. 6 J) to adjust the clock to the current time.
button: Press to advance the time. button: Press to reverse the time.
(Each time the buttons are pressed, the time will be advanced/reversed in one-minute increments; hold the buttons depressed to change the time quickly in ten-minute increments.)
3
Press the TIME ADJUST button again.
This completes the time setting and starts the clock.
To Use the Remote Control Unit
The remote control unit must be pointed at signal receiver (Fig. 1 4) to operate
correctly.
Operating range: About 7 meters.
When a signal is properly received by the air conditioner, a beeping sound will
be heard.
If no beep is heard, press the remote control unit button again.
Remote Control Unit Holder
PREPARATION
CAUTION!
Take care to prevent infants from accidentally swallowing batteries.
When not using the remote control unit for an extended period, remove the batteries to avoid possible leakage and damage to the unit.
If leaking battery fluid comes in contact with your skin, eyes, or mouth, immedi­ately wash with copious amounts of water, and consult your physician.
Dead batteries should be removed quickly and disposed of properly, either by placing in a public battery collection receptacle, or by returning to appropri­ate authority.
Do not attempt to recharge dry batteries.
Never mix new and used batteries, or batteries of different types. Batteries should last about one year under normal use. If the remote control units operating range becomes appre­ciably reduced, replace the batteries and press the ACL button with the tip of a ballpoint pen or other small object.
3 To remove the Remote
Control Unit (when use at hand).
1 Mount the Holder. 2 Set the Remote Control
Unit.
Screws
Insert
Press in
Slide up
Pull out
6
1
Press the START/STOP button (Fig.6 N).
The indoor units OPERATION indicator lamp (red) (Fig. 3 6) will light. The air conditioner will start operating.
2
Press the MASTER CONTROL button (Fig.6 I) to se­lect the desired mode.
Each time the button is pressed, the mode will change in the following order:
AUTO COOL DRY
HEAT FAN
About three seconds later, the entire display will reappear.
To Set the Thermostat
Press the SET TEMP. buttons (Fig. 6 J).
button: Press to raise the thermostat setting. button: Press to lower the thermostat setting.
Thermostat setting range:
AUTO .................................. Standard temperature setting ± 2 °C
Heating ............................... 16 to 30 °C
Cooling/Dry ........................ 18 to 30 °C
The thermostat cannot be used to set room temperature during the FAN mode (the temperature will not appear on the remote control unit’s display).
About three seconds later, the entire display will reappear.
The thermostat setting should be considered a standard value, and may differ somewhat from the actual room temperature.
To Set the Fan Speed
Press the FAN CONTROL button (Fig. 6 M).
Each time the button is pressed, the fan speed changes in the following order:
AUTO HIGH MED LOW QUIET
About three seconds later, the entire display will reappear.
When set to AUTO:
Heating : Fan operates so as to optimally circulate warmed air.
However, the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low.
Cooling : As the room temperature approaches that of the thermostat setting,
the fan speed becomes slower.
Fan : The fan will operate at the optimum speed in accordance with the
room temperature in the vicinity of the indoor unit.
When set to QUIET:
SUPER QUIET operation begins. The indoor units airflow will be reduced for qui­eter operation.
SUPER QUIET operation cannot be used during Dry mode. (The same is true
when dry mode is selected during AUTO mode operation.)
During Super Quiet operation, Cooling performance will be reduced somewhat.
To Stop Operation
Press the START/STOP button.
The OPERATION indicator lamp (red) (Fig. 3 6) will go out.
Example: When set to COOL
Example: When set to 26 °C
OPERATION
To Select Mode Operation
ssss
s
ss s
tt
Example: When set to AUTO
7
About Mode Operation
AUTO:
Depending on the room temperature at the time operation begins, the operating
mode will be switched automatically as shown in the accompanying table. Also, depending on the operating mode, the room temperature setting will cause the standard temperature to be set as shown.
Actual Room Operating Mode Thermostat Setting Temperature (standard setting) 30 °C or above Cooling 27 °C 27 to 30 °C Cooling 26 °C 24 to 27 °C Dry 24 °C 22 to 24 °C Monitor Below 22 °C Heating 23 °C
The operating mode and standard thermostat settings are selected automatically when operation begins.
When automatic operation is initiated, the fan will run at very low speed for about
one minute while the unit detects and selects the proper operating mode.
Once the operating mode has been set, the mode will not change even if the
room temperature changes. However, during the monitor operation mode, if the room temperature changes to below 22 °C, the mode will automatically switch to Heat, and when it rises above 24 °C the mode will automatically switch to Dry.
When in the monitor mode, the fan will operate very slowly.
If the START/STOP button is pressed to recommence operation within two hours
after stopping automatic operation, the unit will begin operating from the same mode as before.
Heating:
Use to warm your room.
When Heating mode is selected, the air conditioner will operate at very low fan
speed for about 3 to 5 minutes, after which it will switch to the selected fan set­ting. This period of time is provided to allow the indoor unit to warm up before begin full operation.
When the room temperature is very low, frost may form on the outside unit, and
its performance may be reduced. In order to remove such frost, the unit will automatically enter the defrost cycle from time to time. During Automatic De­frosting operation, the OPERATION indicator lamp (red) will flash, and the heat operation will be interrupted.
Cooling:
Use to cool your room.
Dry:
Use for gently cooling while dehumidifying your room.
You cannot heat the room during Dry mode.
During Dry mode, the unit will operate at low speed; in order to adjust room
humidity, the indoor units fan may stop from time to time. Also, the fan may operate at very low speed when detecting room humidity.
The fan speed cannot be changed manually when Dry mode has been selected.
Fan:
Use to circulate the air throughout your room.
OPERATION
During Heating mode:
Set the thermostat to a temperature set­ting that is higher than the current room temperature. The Heating mode will not operate if the thermostat is set lower than the actual room temperature.
During Cooling/Dry mode:
Set the thermostat to a temperature set­ting that is lower than the current room temperature. The Cooling and Dry modes will not operate if the thermostat is set higher than the actual room temperature (in Cooling mode, the fan alone will oper­ate).
During Fan mode:
If the outdoor unit is in the heating mode, it cannot be operated in fan mode. If fan mode is selected, the OPERATION indicator lamp (red) will flash quickly (1 second on, 1 second off) and will be set to monitor operation. (See pages 4 and
17).
8
To Use the ON timer or OFF timer
1
Press the START/STOP button (Fig. 6 N) (if the unit is already operating, proceed to step 2).
The indoor units OPERATION indicator lamp (red) (Fig. 3 6) will light.
2
Press the TIMER button (Fig. 6 L) to select the OFF timer or ON timer operation.
Each time the button is pressed the timer function changes in the follow­ing order:
RESET OFF ON
PROGRAM(OFF ON, OFF ON)
The indoor units TIMER indicator lamp (green) (Fig. 3 7) will light.
3
Use the SET TIME buttons (Fig. 6 J) to adjust the de­sired OFF time or ON time.
Set the time while the time display is flashing (the flashing will continue for about five seconds).
button: Press to advance the time. button: Press to reverse the time.
About five seconds later, the entire display will reappear.
To Use the PROGRAM timer
1
Press the START/STOP button (Fig. 6 N) (if the unit is already operating, proceed to step 2).
The indoor units OPERATION indicator lamp (red) (Fig. 3 6) will light.
2
Set the desired times for OFF timer and ON timer.
See the section To Use the ON timer or OFF timer to set the desired mode and times. About three seconds later, the entire display will reappear. The indoor units TIMER indicator lamp (green) (Fig. 3 7) will light.
3
Press the TIMER button (Fig. 6 L) to select the PRO­GRAM timer operation (either OFF ON or OFF ON will display).
The display will alternately show OFF timer and ON timer, then change to show the time setting for the operation to occur first.
The PROGRAM timer will begin operation. (If the ON timer has been selected to operate first, the unit will stop operating at this point.)
About five seconds later, the entire display will reappear.
About the PROGRAM timer
The PROGRAM timer allows you to integrate OFF timer and ON timer operations in a single sequence. The sequence can involve one transition from OFF timer to ON timer, or from ON timer to OFF timer, within a twenty-four hour period.
The first timer function to operate will be the one set nearest to the current time. The order of operation is indicated by the arrow in the Remote Control Unit’s display (OFF ON, or OFF ON).
One example of PROGRAM timer use might be to have the air conditioner auto­matically stop (OFF timer) after you go to sleep, then start (ON timer) automati­cally in the morning before you arise.
TIMER OPERATION
sss
t
Before using the timer function, be sure that the Remote Control Unit is set to the correct current time (See page 5).
To Cancel the Timer
Use the TIMER button to select “TIMER RESET”. The air conditioner will return to normal operation.
To Change the Timer Settings
Perform steps 2 and 3.
To Stop Air Conditioner Operation while the Timer is Operating
Press the START/STOP button.
To Change Operating Conditions
If you wish to change the operating conditions (Mode, Fan Speed, Thermostat Setting), after making the timer setting, wait until the entire display reappears, then press the appropriate buttons to change the operating condition desired.
To Cancel the Timer
Use the TIMER button to select “TIMER RESET”. The air conditioner will return to normal operation.
To Change the Timer Settings
1.
Follow the instructions given in the section To Use the ON Timer or OFF Timer to se­lect the timer setting you wish to change.
2. Press the TIMER button to select either OFF ON or OFF ON.
To Stop Air Conditioner Operation while the Timer is Operating
Press the START/STOP button.
To Change Operating Conditions
If you wish to change operating conditions (Mode, Fan Speed, Thermostat Setting), after making the timer setting wait until the entire display reappears, then press the appropriate buttons to change the operat­ing condition desired.
9
SLEEP TIMER OPERATION
Unlike other timer function , the SLEEP timer is use to set the length of time until air conditioner operate is stopped.
To Use the SLEEP timer
While the air conditioner is operating or stopped, press the SLEEP button (Fig. 6 H).
Both the indoor units OPERATION indicator lamp (red) (Fig. 3 6) and the TIMER indicator lamp (green) (Fig. 3 7) will light.
To Change the Timer Settings
Press the SLEEP button (Fig. 6 H) once again and set the time using the SET TIME buttons (Fig. 6 J).
Set the time while the Timer Mode Display is flashing (the flashing will continue for about five seconds).
button: Press to advance the time. button: Press to reverse the time.
About five seconds later, the entire display will reappear.
To Cancel the Timer:
Use the TIMER button to select “TIMER RESET”. The air conditioner will return to normal operation.
To Stop the Air Conditioner During Timer Operation:
Press the START/STOP button.
About the SLEEP timer
To prevent excessive warming or cooling during sleep, the SLEEP timer function automatically modifies the thermostat set­ting in accordance with the time setting. When the set time has elapsed, the air conditioner completely stops.
During Heating operation:
When the SLEEP timer is set, the thermostat setting is automatically lowered 1 °C every thirty minutes. When the thermostat has been lowered a total of 4 °C, the thermostat setting at that time is maintained until the set time has elapsed, at which time the air conditioner automatically turns off.
SLEEP timer setting
During Cooling/Dry operation:
When the SLEEP timer is set, the thermostat setting is auto­matically raised 1 °C every sixty minutes. When the thermo­stat has been raised a total of 2 °C, the thermostat setting at that time is maintained until the set time has elapsed, at which time the air conditioner automatically turns off.
SLEEP timer setting
Set time
1 hour
1 °C
2 °C
2 °C
3 °C
4 °C
30 minutes
1 °C
1 hour
1 hour 30 minutes
Set time
10
ADJUSTING THE DIRECTION OF AIR CIRCULATION
Vertical (up-down) direction of airflow is adjusted by pressing the Remote Control Units AIR FLOW DIRECTION button. Hori­zontal (right-left) airflow direction is adjusted manually, by moving the Air Flow Direction Louvers. Whenever making horizontal airflow adjustments, start air conditioner operation and be sure that the vertical air direction louvers are stopped.
DANGER!
Never place fingers or foreign objects inside the outlet ports, since the internal fan oper­ates at high speed and could cause personal injury.
Always use the remote control unit’s AIR FLOW DIRECTION button to adjust the vertical airflow louvers. Attempting to move them manually could result in improper operation; in this case, stop operation and restart. The louvers should begin to operate properly again.
During use of the Cooling and Dry modes, do not set the Air Flow Direc­tion Louvers in the range (5 to 7) for long periods of time, since water vapor may condense near the outlet louvers and drops of water may drip from the air conditioner. During the Cooling and Dry modes, if the Air Flow Direction Louvers are left in the range (5 to 7) for more than 30 minutes, they will au­tomatically return to position 4.
When used in a room with infants, chil­dren, elderly or sick persons, the air direction and room temperature should be considered carefully when making settings.
Vertical Air Direction Adjustment
Press the AIR FLOW DIRECTION button (Fig. 6 O).
Each time the button is pressed, the air direction range will change as follows:
1
2 3 4 5 6 7
Types of Air flow Direction Setting:
1,2,3,4 : During Cooling/Dry modes 5,6,7 : During Heating mode
The remote control unit’s display does not change.
Use the air direction adjustments within the ranges shown above.
The vertical airflow direction is set automatically as shown, in accordance with
the type of operation selected.
During Cooling/Dry modes : Horizontal flow 1
During Heating mode : Downward flow 7
During AUTO mode operation, for the first minute after beginning operation,
airflow will be horizontal 1; the air direction cannot be adjusted during this pe­riod.
Right-Left Adjustment
Adjust the Right-Left louvers.
Move the Right-Left louvers to adjust air flow in the direction you prefer.
Right-Left Louvers
knob
11
The range of swing is relative to the currently set airflow direction.
If the swing range is not as desired, use the Remote Con­trol Unit’s AIR FLOW DIRECTION button to change the range of swing.
SWING OPERATION
Begin air conditioner operation before performing this procedure.
To select SWING Operation
Press the SWING LOUVER button (Fig. 6 P).
The SWING indicator lamp (orange) (Fig. 3 8) will light. In this mode, the Air Flow Direction Louvers will swing automatically to direct the airflow both up and down.
To Stop SWING Operation
Press the SWING LOUVER button (Fig. 6 P) once again.
The SWING indicator lamp (orange) (Fig. 3 8) will go out. Airflow direction will return to the setting before swing was begun.
About Swing Operation
During Cooling/Dry modes, if SWING Operation is con­tinued at the lowest (downward) range for more than 30 minutes, the unit will automatically switch the swing range to the horizontal flow range to prevent the condensation of moisture on the outlet.
The SWING operation may stop temporarily when the air conditioner’s fan is not operating, or when operating at very low speeds.
MANUAL AUTO OPERATION
Use the MANUAL AUTO operation in the event the Remote Control Unit is lost or otherwise unavailable.
How To Use the Main Unit Controls
Press the MANUAL AUTO button (Fig. 2 3) on the main unit control panel.
To stop operation, press the MANUAL AUTO button once again, or set the POWER switch (Fig. 2 2) to OFF. (Controls are located inside the intake grille.)
When the air conditioner is operated with the controls on the Main unit, it will operate under the same mode as the AUTO mode selected on the Re­mote Control Unit (see page 6).
The fan speed selected will be “AUTO and the thermostat setting will be standard.
12
Before cleaning the air conditioner, be sure to turn it off and disconnect the power supply cord.
Be sure the intake grille (Fig. 1 9) is installed securely.
When removing and replacing the air filters, be sure not to touch the heat exchanger, as per-
sonal injury may result.
CLEANING AND CARE
CAUTION!
Cleaning the Intake Grille
1. Remove the intake grille.
1 Place your fingers at both lower ends of the grille
panel, and lift forward; if the intake grille seems to catch partway through its movement, continue lifting upward to remove.
2 Lift up the intake grille fully to remove.
2. Clean with water.
Remove dust with a vacuum cleaner; wipe the unit with warm water, then dry with a clean, soft cloth.
3. Replace the intake grille.
1 Holding the intake grille horizontally, fasten the two
upper hooks on the unit.
2 Press the intake grille down at the lower sides to close.
Cleaning the Air Filter
1. Open the intake grille, and remove the air filter.
Lift up the air filters handle, disconnect the two lower tabs, and pull out.
2. Remove dust with a vacuum cleaner or by washing.
After washing, allow to dry thoroughly in a shaded place.
3. Replace the air filter and close the intake grille.
1 Align the sides of the air filter with the panel, and push
in fully, making sure the two lower tabs are returned properly to their holes in the panel.
2 Close the intake grille.
(For purposes of example, the illustration shows the unit without intake grille installed.)
Dust can be cleaned from the air filter either with a vacuum
cleaner, or by washing the filter in a solution of mild de­tergent and warm water. If you wash the filter, be sure to allow it to dry thoroughly in a shady place before rein­stalling.
If dirt is allowed to accumulate on the air filter, air flow
will be reduced, lowering operating efficiency and increas­ing noise.
During periods of normal use, the air filters should be
cleaned every two weeks.
When using the optional Air Cleaning Filter
Install the optional Air Cleaning Filter set (APS-02F) as instructed (installation instructions are furnished with the Air Clean­ing Filter set).
When used for extended periods, the unit may accumulate dirt inside, reducing its performance. We recommend that the unit be inspected regularly, in addition to your own cleaning and care. For more information, consult authorized service personnel.
When cleaning the unit’s body, do not use water hotter than 40 °C, harsh abrasive cleansers, or volatile agents like benzene or thinner.
Do not expose the unit body to liquid insecticides or hairsprays.
When shutting down the unit for one month or more, first allow the fan mode to operate continuously for about one-half
day to allow internal parts to dry thoroughly.
Intake grille
Air filter handle
Hooks (two places)
Intake grille
Hooks (two places)
13
Air Cleaning Filter Installation
1. Open the intake grille and remove the air filters.
2. Install the air cleaning filter set (set of 2).
1 Set the air cleaning filter into the air cleaning filter
frame.
2 Engage the latch at both ends of the filter with the
two hooks at the rear of the air cleaning filter frame.
Take care that the air cleaning filter does not project be­yond the frame.
3 Engage the four fixing locations at the top and bot-
tom of the air cleaning filter frame with the hooks of the air filter.
3. Install the two air filters and close the intake grille.
When air cleaning filters are used, the effect will increased
by setting the fan speed to “High”.
Air cleaning filter set
Intake grille
Air filters (left and right)
Air cleaning filter frame
Air cleaning filter
Hooks (two places at the rear)
Latches (two places)
Rear of the filter
Fixing location, hooks (four places)
Air filters (left and right)
Replacing dirty Air cleaning filters
Please purchase the separately sold replacement air clean­ing filters (type APS-02F) and install them.
1. Open the intake grille and remove the air filters.
2. Replace them by two new air cleaning filters.
1 Remove the old air cleaning filters in reverse order of
their installation.
2 Install in the same way as for installation of the air
cleaning filter set.
3. Install the two air filters and close the intake grille.
In regard to the Air cleaning filters
The air cleaning filters are disposable filters. (They can
not be washed and reused.) However, the filter frame is used again.
For storage of the air cleaning filters, avoid places with
high temperatures and high humidity, and use the filters as soon as possible after the package has been opened. (The air cleaning effect decreases when the filters are left in the opened package.)
Generally, the filters should be exchanged about every
three months.
If the color of the air cleaning filter approaches that of the
color seal stuck to the indoor unit even before three months have elapsed, replace the filter as soon as possi­ble.
Intake grille
Air filters (left and right)
Air filters (left and right)
Air cleaning filter frame
Air cleaning filter
color seal
CLEANING AND CARE
14
TROUBLESHOOTING
In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the cir­cuit breaker, and consult authorized service personnel. Merely turning off the units power switch will not completely disconnect the unit from the power source. Always be sure to turn off your circuit breaker to ensure that power is completely off.
Before requesting service, perform the following checks:
WARNING!
Symptom
Doesnt operate immedi­ately:
Noise is heard:
Smells:
Mist or steam are emitted:
Airflow is weak or stops:
Water is produced from the outdoor unit:
The indoor unit is warm when stopped (heating mode):
Problem
If the unit is stopped and then immediately started again, the com­pressor will not operate for about 3 minutes, in order to prevent fuse blowouts.
Whenever the power supply plug is disconnected and then recon­nected to a power outlet, the protection circuit will operate for about 3 minutes, preventing unit operation during that period.
During operation and immediately after stopping the unit, the sound of water flowing in the air conditioners piping may be heard. Also, noise may be particularly noticeable for about 2 to 3 minutes after starting operation (sound of coolant flowing).
During operation, a slight squeaking sound may be heard. This is the result of minute expansion and contraction of the front cover due to temperature changes.
During Heating operation, a sizzling sound may be heard occa­sional. This sound is produced by the Automatic Defrosting op­eration.
Some smell may be emitted from the indoor unit. This smell is the result of room smells (furniture, tobacco, etc.) which have been taken into the air conditioner.
During Cooling or Dry operation, a thin mist may be seen emitted from the indoor unit. This results from the sudden Cooling of room air by the air emitted from the air conditioner, resulting in condensation and misting.
During Heating operation, the outdoor unit’s fan may stop, and steam may be seen rising from the unit. This is due to Automatic Defrosting operation.
When Heating operation is started, fan speed is temporarily very low, to allow internal parts to warm up.
During Heating operation, if the room temperature rises above the thermostat setting, the outdoor unit will stop, and the indoor unit will operate at very low fan speed. If you wish to warm the room further, set the thermostat for a higher setting.
During Heating operation, the unit will temporarily stop opera­tion (between 7 and 15 minutes) as the Automatic Defrosting mode operates. During Automatic Defrosting operation, the OPERATION indicator lamp will flash.
The fan may operate at very low speed during Dry operation or when the unit is monitoring the rooms temperature.
During SUPER QUIET operation, the fan will operate at very low speed.
In the monitor AUTO operation, the fan will operate at very low speed.
During Heating operation, water may be produced from the out-
door unit due to Automatic Defrosting operation.
When the indoor unit is operating in the heating mode, a small amount of the refrigerant is allowed to flow to the indoor unit in order to prevent too much of the refrigerant from accumulating in the outdoor unit. This causes the indoor unit to become warm when stopped. This condition is normal.
See Page
15
15
15
6
6
6
15
NORMAL
FUNCTION
15
TROUBLESHOOTING
Symptom
Doesnt operate at all:
Poor Cooling (or Heating) performance:
The unit operates differently from the remote control unit’s setting:
See Page
5
8
6
5
CHECK ONCE
MORE
Items to check
Has the circuit breaker been turn off?
Has there been a power failure?
Has a fuse blown out, or a circuit breaker been tripped?
Is the main POWER switch set to the OFF position?
Is the timer operating?
Is the air filter dirty?
Are the air conditioners intake grille or outlet port blocked?
Did you adjust the room temperature settings (thermostat) cor-
rectly?
Is there a window or door open?
In the case of Cooling operation, is a window allowing bright sun-
light to enter? (Close the curtains.)
In the case of Cooling operation, are there heating apparatus and computers inside the room, or are there too many people in the room?
Is the unit set for SUPER QUIET operation?
Are the Remote Control Units batteries dead?
Are the Remote Control Units batteries loaded properly?
If the problem persists after performing these checks, or if you notice burning smells, or the TIMER indicator Lamp (Fig. 3 7) flashes, immediately stop operation, turn off the circuit breaker, and consult authorized service personnel.
OPERATING TIPS
Heating Performance
This air conditioner operates on the heat-pump principle, absorbing heat from outdoor air and transferring that heat indoors. As a result, the operating performance is reduced as outdoor air temperature drops. If you feel that insuffi­cient heating performance is being produced, we recom­mend you use this air conditioner in conjunction with another kind of heating appliance.
Heat-pump air conditioners heat your entire room by recirculating air throughout the room, with the result that some time may be required after first starting the air con­ditioner until the room is heated.
Microcomputer-controlled Automatic Defrosting
When using the Heating mode under conditions of low outdoor air temperature high humidity, frost may form on the outdoor unit, resulting in reduced operating per­formance.
In order to prevent this kind of reduced performance, this unit is equipped with a Microcomputer-controlled Auto­matic Defrosting function. If frost forms, the air condi­tioner will temporarily stop, and the defrosting circuit will operate briefly (for about 7 to 15 minutes).
During Automatic Defrosting operation, the OPERATION indicator lamp (red) will flash slowly.
Operation and Performance
16
OPERATING TIPS
Dry Mode
About 0 to 43 °C
About 18 to 32 °C
About 80 % or less If the unit is used for long peri­ods under high-humidity condi­tions, condensation may form on the surface of the indoor unit, and drip onto the floor or other objects underneath.
Outdoor temperature
Indoor temperature
Indoor humidity
Cooling Mode
About 0 to 43 °C
About 18 to 32 °C
About 80 % or less If the unit is used for long peri­ods under high-humidity condi­tions, condensation may form on the surface of the indoor unit, and drip onto the floor or other objects underneath.
Heating Mode
About –10 to 21 °C
About 30 °C or less
In Event of Power Interruption
AUTO Restart
If a power failure occurs during TIMER operation, the timer will be reset and the unit will begin (or stop) operation at the new time setting. In the event that this kind of timer fault occurs the TIMER Indicator Lamp (green) will flash (see page 4).
Use of other electrical appliances (electric shaver, etc.) or nearby use of a wireless radio transmitter may cause the air conditioner to malfunction. In this event, temporarily disconnect the Power Supply Plug, reconnect it, and then use the remote control unit to resume operation.
The air conditioner power has been interrupted by a power failure. The air conditioner will then restart automatically in its previous mode when the power is restored.
Operated by setting before the power failure. Then, the Air Flow Direction Louvers will automatically change to their stand­ard direction.
Temperature and Humidity Range
If the air conditioner is used under higher temperature conditions than those listed, the built-in protection circuit may operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of lower temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.
Do not use this unit for any purposes other than the Cooling, (Heating), Dehumidifying, and air-circulation of rooms in ordinary dwellings.
17
Multi-type Air conditioner
OPERATING TIPS
This indoor unit can be connected to a multi-type outdoor unit. The multi-type air conditioner allows multiple indoor units to be operated in multiple locations. The indoor units may be operated simultaneously, in accordance with their respective output.
When using a multi-type air conditioner, the multiple in­door units can be operated simultaneously, but when two or more indoor units of the same group are operated si­multaneously, the heating and cooling efficiency will be less than when a single indoor unit is used alone. Ac­cordingly, when you wish to use more than one indoor unit for cooling at the same time, the use should be con­centrated at night and other times when less output is required. In the same way, when multiple units are used simultaneously for heating, it is recommended that they be used in conjunction with other auxiliary space heat­ers, as required.
Seasonal and outdoor temperature conditions, the struc­ture of the rooms and the number of persons present may also result in differences of operating efficiency. We rec­ommend that you try various operating patterns in order to confirm the level of heating and cooling output pro­vided by your units, and use the units in the way that best matches your family's lifestyle.
If you discover that one or more units delivers a low level of cooling or heating during simultaneous operation, we recommend that you stop simultaneous operation of the multiple units.
Operation cannot be done in the following different op­erating modes.
If the indoor unit is instructed to do an operating mode that it cannot perform, the OPERATION indicator lamp (red) on the indoor unit will flash (1 second on, 1 second off) and the unit will go into the standby mode.
Heating mode and cooling mode (or dry mode)
Heating mode and fan mode
Operation can be done in the following different operat­ing modes.
Cooling mode and dry mode
Cooling mode and fan mode
Dry mode and fan mode
The operating mode (heating mode or cooling (dry) mode) of the outdoor unit will be determined by the operating mode of the indoor unit that was operated first. If the in­door unit was started in fan mode, the operating mode of the outdoor unit will not be determined.
For example, if indoor unit (A) was started in fan mode and then indoor unit (B) was then operated in heating mode, indoor unit (A) would temporarily start operation in fan mode but when indoor unit (B) started operating in heating mode, the OPERATION indicator lamp (red) for indoor unit (A) would begin to flash (1 second on, 1 sec­ond off) and it would go into standby mode. Indoor unit (B) would continue to operate in heating mode.
During use of the heating mode, the outdoor unit will occasionally commence the defrost operation for brief periods. During the defrosting operation, if the user sets the indoor unit for heating again, the defrosting mode will continue, and the heating operation will begin after completion of defrosting, with the result that some time may be required before warm air is emitted.
During use of the heating mode, the top of the indoor unit may become warm, but this is due to the fact that coolant is circulated through the indoor unit even when it is stopped; it is not a malfunction.
Notice
Simultaneous Use of Multiple Units
18
INDOOR UNIT
Cooling Capacity
[kW]
[BTU]
Heating Capacity
[kW]
[BTU]
Noise Level
High [dB (A)]
Med [dB (A)]
Low [dB (A)]
Quiet [dB (A)]
Dimensions H × W × D [mm]
Net Weight [kg]
Air Flow Rate [m
3
/h]
Pipe connections
Type
Liquid Side
Gas Side
SPECIFICATIONS
AST9QM AST12QM AST18QM AST24QM
2.7 3.5 5.2 6.9
9,200 12,000 17,800 23,600
3.3 4.0 6.2 8.2
11,300 13,700 21,200 28,000
38 39 42 46
36 37 39 42
34 35 36 37
31 32 33 34
260 × 815 × 175 320 × 1,120 × 220
816
440 500 840 1000
Flare
ø6.35 ø6.35 ø6.35 ø9.52
ø9.52 ø12.7 ø12.7 ø15.88
OUTDOOR UNIT
Number of Indoor Units
Combined I.U/O.U Total Capacity [BTU]
Operating Mode
Power Supply
Rated
Capacity
[BTU]
[kW]
Running Current [A]
Power Input [kW]
Power Factor [%]
COP
Capacity Range [kW]
Running Current [A]
Power Input Range [kW]
Starting Current [A]
Noise Level [dB (A)]
Dimensions [mm]
Net Weight [kg]
Compressor
Type
Motor output [kW]
Piping Connections
Type
Unit A
Unit B
Unit C
Unit D
Maximum Pipe Length (Each Unit) [m]
Maximum Pipe Length (Total) [m]
Maximum Pipe Height Different [m]
Refrigerant
Wiring Connection
Power Supply
Indoor to Outdoor
Operating Temperature Range [°C]
AOT30QMAM4
4
27,000-48,000 (8.0-14.0 kW)
Cooling Heating
240-(220) V 50 Hz
27,300 31,800
8.0 9.3
11.2 11.0
2.67 2.62
100 100
3.00 3.55
1.8-9.5 2.0-11.2
3.0-16.1 3.3-16.2
0.68-3.85 0.77-3.86
10
48/53
900 × 900 × 350
75
Twin rotary type with DC-inverter
1.3
Flare
ø6.35 (ø9.52)/ø9.52 or ø12.7 (ø15.88)
ø6.35/ø9.52 or ø12.7
ø6.35/ø9.52 or ø12.7
ø6.35/ø9.52 or ø12.7
25
60
10
R407C 3,000g
2 Wires + Earth
3 Wires + Earth
10 to 46 (Cooling)/-10 to 21 (Heating)
Acoustic Noise Information : The maximum sound pressure level is less than 70 dB (A) for both indoor unit and outdoor
unit. According to IEC 704-1 and ISO 3744.
Loading...