Fujitsu ART90EL, ART90EL3, ART90TL, ART90TL3, AOT90EP Operating Manual

...
KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE
FUJITSU GENERAL LIMITED
P/N9365350010
Indoor Unit
ART90EL(3) ART90TL(3)
Outdoor Unit
OPERATING MANUAL
AIR CONDITIONER
DUCT TYPE
1
CONTENTS
Do not attempt to install this air conditioner by yourself.
This unit contains no user-serviceable parts. Always consult authorized service per-
sonnel for repairs.
When moving, consult authorized service personnel for disconnection and installa­tion of the unit.
Do not become over-exposed to cold air by staying in the direct path of the air flow of the air conditioner for extended periods of time.
Do not insert fingers or objects into the outlet port or intake grilles.
Do not start and stop air conditioner operation by turning off the electrical breaker
and so on.
In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical breaker, and consult authorized service personnel.
Provide occasional ventilation during use.
Do not direct air flow at fireplaces or heating apparatus.
Do not climb on, or place objects on, the air conditioner.
Do not expose the air conditioner directly to water.
Do not operate the air conditioner with wet hands.
Turn off power source when not using the unit for extended periods.
Always turn off the electrical breaker whenever cleaning the air conditioner or chang-
ing the air filter.
Connection valves become hot during Heating; handle with care.
Check the condition of the installation stand for damage.
Do not place animals or plants in the direct path of the air flow.
When restarting after a long period of disuse in the winter, do:
Turn the power switch on at least 12 hours before starting the unit.
Do not drink the water drained from the air conditioner.
Do not use in applications involving the storage of foods, plants or animals, precision
equipment, or art works.
Do not apply any heavy pressure to radiator fins.
Operate only with air filters installed.
Do not block or cover the intake grille and outlet port.
Ensure that any electronic equipment is at least one metre away from either the in-
door or outdoor units.
Avoid installing the air conditioner near a fireplace or other heating apparatus.
Whe
n installing the indoor and outdoor unit, take precautions to prevent access to infan
ts.
Do not use inflammable gases near the air conditioner.
CAUTION!
DANGER!
SAFETY PRECAUTIONS
Before using the appliance, read these “PRECAUTIONS” thoroughly and operate in the correct way.
The instructions in this section all relate to safety; be sure to maintain save operating conditions.
“DANGER”, “WARNING” and “CAUTION” have the following meanings in these instructions:
WARNING!
CAUTION!
This mark indicates procedures which, if improperly performed, are most likely to result in the death of or serious injury to the user or service personnel.
This mark indicates procedures which, if improperly performed, might lead to the death or serious injury of the user.
This mark indicates procedures which, if improperly performed, might possibly result in personal harm to the user, or damage to property.
DANGER!
SAFETY PRECAUTIONS ....................................... 1
NAME OF PARTS ................................................... 2
PREPARATION ....................................................... 3
OPERATION ........................................................... 3
TIMER OPERATION (OFF TIMER/ON TIMER) ...... 4
TIMER OPERATION (WEEKLY TIMER) ................. 5
ENERGY SAVE OPERATION ............................... 10
SYSTEM OPERATION ......................................... 11
CARE AND MAINTENANCE ............................... 11
OPERATION DETAILS .......................................... 12
ERRORS AND SELF DIAGNOSIS ....................... 13
TROUBLESHOOTING .......................................... 13
2
°C
NON STOP
CLOCK
TEMP
AUTO
TIMER MODE
SET
ZONE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
21
HIGH
COOL
DEFROST TEST
DAY OFF
ENERGY SAVE
°C
NON STOP
CLOCK
TIMER
NEXT DAY
DAY
TEMP.
OFFON TIMER WEEKLY
AUTO
OFF
ON
OFF
ON
DAY OFF
21
HIGH MED LOW
AUTO
HEAT FAN COOL
DEFROST TEST
*
DAB 80
C 9 7
G
F
J
E
H I
Q
R
L
K
MNOP
5
6
6
5
NAME OF PARTS
Fig. 1
Fig. 2
Fig. 3
For explanatory purposes, the figure showing the remote
controller display shows all possible displays. The actual display shows only that area that is being adjusted or used.
Fig. 4 Display
Fig. 1 Indoor Unit
1 Outlet Port
2 Intake Port
3 Drain Pipe (Main)
4 Drain Pipe (Safety)
Fig. 2 Outdoor Unit
5 Air intake
6 Air outlet
Fig. 3 Remote Controller
7 START/STOP Button
8 Operation Lamp
9 ENERGY SAVE Button
0 DAY OFF Button
A ENERGY SAVE Lamp
B ZONE Control Button
C SET Button
D ZONE Control Lamp
E CLOCK ADJUST Button
F TIMER MODE Button
G SET TIME Button
H SET TEMP./DAY Button
#I FAN CONTROL Button
J MASTER CONTROL Button
K Remote Controller Display
(Fig. 4)
L Timer Mode Display
M Clock Display (CLOCK/TIMER)
N Set Temperature Display
(TEMP.)
#O Fan Speed Display
P Operation Mode Display
Q DEFROST Display
R TEST Display
Instructions relating to heating (*) are applicable only to HEAT & COOL MODEL (Reverse Cycle).
Install this with the power sup-
ply chain during on-site instal­lation.
#NOTE: This model does not have a fan speed function. (I, O)
Electrical Breaker
2
1
3
4
3
°C
NON STOP
CLOCK
TEMP
AUTO
TIMER MODE
SET
ZONE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
21
HIGH
AUTO
COOL
DEFROST TEST
DAY OFF
ENERGY SAVE
°C
NON STOP
CLOCK
TEMP
AUTO
TIMER MODE
SET
ZONE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
21
HIGH
AUTO
COOL
DEFROST TEST
DAY OFF
ENERGY SAVE
1
2
CLOCK
21
Set the Current Time and Day
1
Press the CLOCK ADJUST button for more than three seconds.
2
Press the SET TEMP./DAY button and set the day.
: Use to advance the day forward.: Use to turn the day back.
The day is indicated by a code number from 1 to 7, as shown in the table below. Set to the number that corresponds to the current day.
DAY CODE 1 2 34567
DAY OF THE WEEK MON TUE WED THU FRI SAT SUN
3
Press the SET TIME button and set the time.
: Use to advance the time forward.: Use to turn the time back.
(Press once to move the time 1 minute; hold down and the time will move 10 minutes at a time.)
4
Press the CLOCK ADJUST button again.
This registers the new day and time values. The day display goes off, and the time display stops flashing.
PREPARATION
CLOCK
DAY
AUTO
TIMER MODE
SET
ZONE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
21
AUTO
DEFROST TEST
DAY OFF
ENERGY SAVE
3
2
1
Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL (Reverse Cycle).
To Select Mode Operation
1
Press the START/STOP button.
The unit will start and the remote controller’s operation lamp (green) will light up.
2
Press the MASTER CONTROL button to select the de­sired mode.
*HEAT FAN COOL
To Set the Thermostat
Press the SET TEMP./DAY button to the desired temperature.
▲ : Press to raise the thermostat setting. ▼ : Press to lower the thermostat setting.
Thermostat setting range:
* Heating ............................... 16 °C to 30 °C
Cooling ............................... 18 °C to 30 °C
The thermostat cannot be used to set room temperature during the FAN mode (the temperature will not appear on the remote controller’s display).
The thermostat setting should be considered a standard value, and may differ somewhat from the actual room temperature.
To Stop Operation
Press the START/STOP button.
The remote controller’s operation lamp (green) will go out. The display contents disappear and only the current time is displayed.
OPERATION
Example: Set the time to 9:31.
ccc
Example: When set to COOL
Example: When set to 26 °C
4
°C
CLOCK
TIMER
TEMP
OFF TIMER
AUTO
OFF
TIMER
MODE
SET
ZONE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
21
HIGH
AUTO
COOL
DEFROST TEST
DAY OFF
ENERGY SAVE
°C
CLOCK
TIMER
TEMP
OFF TIMER
AUTO
OFF
TIMER MODE
SET
ZONE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
21
HIGH
AUTO
COOL
DEFROST TEST
DAY OFF
ENERGY SAVE
1
2
TIMER OPERATION (OFF TIMER/ON TIMER)
Before using the timer function, be sure that the remote controller is set to the correct current time and Day. Press the START/STOP button; after the unit starts operation perform the following procedure:
cc
c
OFF Timer / ON Timer
1
Press the TIMER MODE button and display either OFF Timer or ON Timer.
The timer will start operating. (If you set the ON timer, the air conditioner will stop operating.)
Each time the button is pressed the timer function changes in the follow­ing order:
NON STOP (RESET) OFF ON WEEKLY
2
Press the SET TIME button and set the timer time.
▲ : Use to advance the time forward. ▼ : Use to turn the time back.
(Press once to move the time 1 minute; hold down and the time will move 10 minutes at a time.)
Example: Setting the OFF TIMER
to 23:35
c
To confirm or Change Settings Before Starting Operation
To confirm settings
Press the TIMER MODE button once. (The timer setting information will be displayed for 15 seconds after the TIMER MODE button is pressed.)
To change settings
Confirm the settings as noted above, then press the SET TIME button and TIMER MODE button as necessary to change the desired timer setting. (The timer settings will be displayed for 15 seconds after the button is pressed.)
After confirming or changing the set­tings, press the START/STOP button to start operation.
To Change the Timer Setting During Operation
Operate as noted in step 2.
To Change the Timer Mode During Operation
Press the TIMER MODE button and set the unit to the desired mode.
To Cancel the Timer Mode During Timer Operation
Press the TIMER MODE button and set the display to NON STOP (the unit will switch to non-stop operation).
To Stop Operation During Use of Timer Mode
Press the START/STOP button.
5
TIMER OPERATION (WEEKLY TIMER)
Use the weekly timer to set operating times for each day of the week.
Weekly Timer Features
Set different operating times for each day of the week.
Set one or two operating spans (one or two ON times and one or two OFF times) per day.
Set time to a resolution of 5 minutes.
OFF time can be carried over to the subsequent day.
Use the DAY OFF setting to cancel operation for any day of the coming week (one-time cancellation).
TIMER
DAY
WEEKLY
AUTO
ON
OFF
TIMER
MODE
SET
ZONE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
21
HIGH
AUTO
COOL
DEFROST TEST
DAY OFF
ENERGY SAVE
1
2
3
TIMER
DAY
WEEKLY
AUTO
ON
OFF
TIMER
MODE
SET
ZONE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
21
AUTO
DEFROST TEST
DAY OFF
ENERGY SAVE
4
5
Setting Up the Weekly Timer Operation
Press the START/STOP button to stop the air conditioner, and then proceed as fol­lows.
1
Press the TIMER MODE button so that “WEEKLY” ap­pears on the display.
The display now shows the current day (by DAY CODE), the first ON and OFF times for the day (the WEEKLY 1 times), the fan speed, and the operating mode. The top time value gives the ON time, and the bottom value gives the OFF time. If either time is not set, the corresponding time display is blank
.
2
Press the SET TEMP./DAY button to select the day that you want to set up.
: Use to advance the day forward. : Use to turn the day back.
DAY CODE 1 2 3 4 5 6 7
DAY OF THE WEEK MON TUE WED THU FRI SAT SUN
3
Hold the SET button down for 3 seconds.
The WEEKLY 1 ON time starts flashing, and the fan speed and operat­ing mode displays go off.
4
Press the SET TIME button to set the days first ON time.
: Use to advance the time forward. : Use to turn the time back.
(Press once to move the time 5 minute; hold down and the time will move 10 minutes at a time.)
5
Press the SET button.
This registers the first ON time setting for the selected day. The ON time display stops flashing, and the WEEKLY 1 OFF time starts flashing.
6
TIMER
DAY
WEEKLY
AUTO
ON
OFF
TIMER MODE
SET
ZONE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
21
AUTO
DEFROST TEST
DAY OFF
ENERGY SAVE
6
7
CLOCK
AUTO
TIMER
SET TIME TEMP./DAY FAN
21
AUTO
DEFROST TEST
NOTES:
(1) If no time values are flashing, the clock display will automatically reappear after 15 seconds if no buttons are pressed.
(2) A flashing time value indicates that the system is in time-setting mode. To return to the clock display you must hold
down the SET button for 3 seconds.
(3) You do not need to set values for both WEEKLY 1 and WEEKLY 2. If you wish, you can set values only for WEEKLY 1
or only for WEEKLY 2.
(4) The allowable range for the days time settings is shown below.
(5) If you set the OFF time to occur on the day following the ON time, the NEXT DAY caption appears on the display.
6
Press the SET TIME button to set the days first OFF time.
The earliest OFF time you can set is 5 minutes after the ON time. The latest OFF time is 23:55 on the subsequent day.
7
Press the SET button.
This registers the first OFF time for the day, completing the WEEKLY 1 settings for that day. The display switches to WEEKLY 2, and the day’s second ON time be- gins flashing.
8
Repeat the operations described in Steps 4 to 7 to set the second ON and OFF times for the day (the WEEKLY 2 times).
When you press the SET button after setting the “WEEKLY 2 OFF time, the system registers the WEEKLY 2 settings for the day and returns you to the WEEKLY 1 ON time setup process. (The first ON setting reap­pears and begins flashing.)
You can review your settings by pressing the SET button. Each press moves you to the next setting, as follows.
WEEKLY 1 WEEKLY 1 WEEKLY 2 WEEKLY 2
ON OFF ON OFF
9
Press the SET TEMP./DAY button to select another day for setup. The repeat steps 4 to 8 above to set the ON and OFF times for that day.
10
When you have finished setting all of the times, hold down the SET button for 3 seconds.
The WEEKLY display flashes for 3 seconds while the new WEEKLY TIMER settings are registered, and then the clock display reappears.
ccc
c
Next days WEEKLY
settings
Cannot set
5 min.
Available range Cannot set
5 min.
ON OFF ON OFF
Previous day’s WEEKLY
settings
0:00 0:00
TIMER
NEXT DAY
DAY
WEEKLY
AUTO
ON
OFF
21
AUTO
DEFROST TEST
If the timer is not set, press the SET but­ton with the time display blank ”, and perform next operation.
7
°C
CLOCK
TIMER
TEMP
WEEKLY
AUTO
OFF
TIMER MODE
SET
ZONE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
21
HIGH
AUTO
COOL
DEFROST TEST
DAY OFF
ENERGY SAVE
1
2
Starting Weekly Timer Operation
1
Press the TIMER MODE button so that “WEEKLY” ap­pears on the display.
2
Press the START/STOP button to start operation.
(This step is not necessary if the air conditioner is already running.)
Weekly timer operation starts, and the operation lamp comes on. (If the current time is between the first or second ON and OFF time set­tings for the current day, the air conditioner will start. Otherwise the air conditioner will remain off.)
The day display is replaced by the temperature display. The upper time display now shows the current time, and the lower time display shows the next scheduled ON or OFF time.
To Stop Weekly Timer Operation
To stop weekly timer while leaving the air conditioner run­ning: Press the TIMER MODE button to select NONSTOP, OFF TIMER, or ON TIMER.
To stop weekly timer operation and the air conditioner also: Press the START/STOP button.
Reviewing the Time Settings
Press the START/STOP button to stop the air conditioner, and then proceed as follows.
1 Press the TIMER MODE button so that “WEEKLY” appears
on the display.
2 Press the SET TEMP./DAY button to select the day that you
want check.
3 Press the SET TIME button ( or ) to switch between the
WEEKLY 1 or WEEKLY 2 time displays.
Cancelling Selected Time Settings
Press the START/STOP button to stop the air conditioner, and then proceed as fol­lows.
1
Carry out steps 1 to 3 of the Setting Up the Weekly Timer Operation procedure to select the day you want to edit.
2
Press the SET button to select the ON time that you want to cancel.
Be sure to select an ON time (the upper time display).
3
Hold down the side of the SET TIME button until the time display becomes blank ”.
4
Press the SET button.
The first OFF time setting (WEEKLY 1 OFF time) is deleted and replaced by a flashing blank pattern
.
5
Press the SET button again.
This completes deletion of the WEEKLY 1 ON/OFF settings. The second ON time setting (WEEKLY 2 ON time) appears and flashes. If you wish to delete other time settings, repeat steps 2 through 5.
6
Once the setting has been canceled, hold down the SET button for 3 seconds.
The WEEKLY display flashes briefly, and then the clock display appears.
Example: Clearing the “WEEKLY 1 ON/
OFF times for day 4 (Thursday)
TIMER
DAY
WEEKLY
AUTO
ON
OFF
TIMER MODE
SET
ZONE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
21
AUTO
DEFROST TEST
DAY OFF
ENERGY SAVE
2
3
TIMER
DAY
WEEKLY
AUTO
ON
OFF
21
AUTO
DEFROST TEST
TIMER
DAY
WEEKLY
AUTO
ON
OFF
21
AUTO
DEFROST TEST
TIMER OPERATION (WEEKLY TIMER)
8
To Change Selected Time Settings
Press the START/STOP button to stop the air conditioner, and then proceed as fol­lows.
1
Carry out steps 1 to 3 of the Setting Up the Weekly Timer Operation procedure to select the day you want to edit.
2
Press the SET button to select the time that you want to change.
The selected setting flashes on the display. Each press moves you to the next setting for the selected day, as follows.
WEEKLY 1 WEEKLY 1 WEEKLY 2 WEEKLY 2
ON OFF ON OFF
3
Press the SET TIME button to change the time setting.
4
Press the SET button.
The new setting overwrites the previous setting.
5
Once the setting has been canceled, hold down the SET button for 3 seconds.
The WEEKLY display flashes briefly, and then the clock display appears.
ccc
c
Example: Changing the “WEEKLY 2
ON setting for day 5 (Friday) from 14:00 to 15:30
TIMER
DAY
WEEKLY
AUTO
ON
OFF
TIMER MODE
SET
ZONE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
21
AUTO
DEFROST TEST
DAY OFF
ENERGY SAVE
2
TIMER
DAY
WEEKLY
AUTO
ON
OFF
TIMER MODE
SET
ZONE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
21
AUTO
DEFROST TEST
DAY OFF
ENERGY SAVE
4
3
NOTES:
In the following cases, cancel the set time prior to making the required amendments.
(1) If you want to change the ON time to a time that is later than the currently set OFF time.
(2) If the change would cause a temporary overlap between the first and second ON/OFF time spans.
Temporary overlap
ON OFF
ON
OFF
WEEKLY 1
WEEKLY 1
Change
Change
ON OFF
WEEKLY 1
ON OFF
WEEKLY 2
ON
OFF
WEEKLY 1 WEEKLY 2
Time
Time
Time
Time
ON OFF
9
About the DAY OFF
Use the DAY OFF setting to switch off timed operation for a selected day in the coming week.
This is a temporary, one-time setting. The DAY OFF setting is automatically cleared as soon as the specified day passes.
Next day
Example: To switch off timed operation
for day 2 (Tuesday)
NOTES:
(1) The DAY OFF setting is only available for days for which weekly time settings already exist.
(2) You can make this setting for any of the next seven days (counting from the current day).
(3) The DAY OFF setting is effective over the range illustrated below. The Weekly setting for which an ON time has been
set is eligible for the day in which the DAY OFF has been set.
(4) The display on the clocks lower line will usually be for the DAY OFF set day during Weekly operations.
CLOCK
TIMER
DAY
WEEKLY
AUTO
ON
OFF
DAY OFF
TIMER MODE
SET
ZONE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
21
HIGH
AUTO
COOL
DEFROST TEST
DAY OFF
ENERGY SAVE
2
ON OFF
0:00 0:00
Effective range of DAY OFF setting
WEEKLY setting for preceding
day
WEEKLY setting
Preceding day DAY OFF day
°C
CLOCK
TIMER
TEMP
WEEKLY
AUTO
DAY OFF
21
HIGH
AUTO
COOL
DEFROST TEST
Using the DAY OFF Setting
Press the START/STOP button to stop the air conditioner, and then proceed as fol­lows.
1
Carry out steps 1 to 2 of the Setting Up the Weekly Timer Operation procedure to select the day that you want to set as the DAY OFF.
2
Press the DAY OFF button.
The DAY OFF setting is registered, and the DAY OFF caption appears on the display.
To cancel the DAY OFF setting: You can cancel the setting by pressing the DAY OFF button again.
ON OFF
Precautions during setup
Setup is not possible in the following cases, so amend the time.
If you set an ON time while leaving the OFF time setting blank: Nothing will happen when you press the SET button. To proceed, press the SET TIME button and enter an appropriate setting.
When an attempt is made to set only the OFF time. Nothing will happen when you press the SET TIME button. Press the SET button and amend the entry for the ON time.
ON and OFF times cannot be set to the same value.
The OFF time cannot be set earlier than the ON time.
The WEEKLY 2 settings cannot be set earlier than the WEEKLY 1 settings.
The WEEKLY 1 and WEEKLY 2 time spans cannot overlap.
TIMER OPERATION (WEEKLY TIMER)
10
°C
NON STOP
CLOCK
TEMP
AUTO
TIMER MODE
SET
ZONE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
21
HIGH
AUTO
COOL
DEFROST TEST
DAY OFF
ENERGY SAVE
ENERGY SAVE OPERATION
To Use the ENERGY SAVE
Press the ENERGY SAVE button.
The unit will run in the ENERGY SAVE mode.
The ENERGY SAVE lamp (green) will light.
To Stop the ENERGY SAVE
Press the ENERGY SAVE button one more time.
The ENERGY SAVE mode will be turned off.
The ENERGY SAVE lamp goes off, and the unit will return to the former operat­ing conditions.
About the ENERGY SAVE
The energy conservation mode (ENERGY SAVE) raises the set temperature slightly in the cooling mode and lowers the set temperature in the heating mode, using a computer program to economically control the operation of the unit.
If you press the ENERGY SAVE button while the air conditioner is on, it will change to the conservation mode. If you press the ENERGY SAVE button while the unit is in the timer mode (ON timer, WEEKLY timer), the unit will go into the conserva­tion mode when the unit starts with the timer.
If you turn off the air conditioner while in the conservation mode, the mode will be shut off.
The temperature set on the remote controller will not change if the energy save mode is used.
* When Heating
After the ENERGY SAVE button is pressed, the set tempera­ture will be lowered about 1 °C every 30 minutes. When it has lowered a total of 2 °C, then it will hold that tempera­ture.
When Cooling
After the ENERGY SAVE button is pressed, the set tempera­ture will be raised about 0.5 °C every 30 minutes. When it has gone up a total of 1 °C, then it will hold that tempera­ture.
30 min.
0.5 °C
1 °C
Set to the ENERGY SAVE mode.
1 °C
2 °C
30 min.
Set to the ENERGY SAVE mode.
Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL (Reverse Cycle).
11
°C
NON STOP
CLOCK
TEMP
AUTO
TIMER MODE
SET
ZONE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
21
HIGH
AUTO
COOL
DEFROST TEST
DAY OFF
ENERGY SAVE
SYSTEM OPERATION
<Control Several Units with just one Remote Controller>
One remote controller can control up to 16 air conditioners. All the air conditioners can be operated with the same set­ting.
To Use the ZONE CONTROL
When the ZONE control button is pressed while multiple air conditioners are being centralized controlled, only the preset air conditioners stop.
Press the ZONE control button.
Preset units will stop.
The ZONE lamp (green) will light.
To Stop the ZONE CONTROL
Press the ZONE control button one more time.
Those units that were stopped will start again.
The ZONE lamp will go out.
Unit No.1
Unit No.2 Unit No.16
Remote controller
Outdoor
unit
Indoor unit
Before cleaning the unit, be sure to stop the unit and disconnect the power supply.
Turn off the electrical breaker.
A fan operates at high speed inside the unit, and personal injury could result.
CARE AND MAINTENANCE
CAUTION!
Installing the Air Filter
Be sure the filter is always installed in the inlet air grille of the indoor unit.
Filters can be purchased through your local dealer.
Cleaning the Air Filter
If dirt is allowed to collect in the air filter, the airflow will be reduced, leading to reduced performance, and increased operation noise. Be sure to clean the filters regularly.
How to Cleaning
Use a vacuum cleaner to remove dust and dirt from the air filter, or wash in a synthetic detergent. After washing, dry in a shaded place, then reinstall.
When used for extended periods, the unit may accumulate dirt inside, reducing its performance. We recommend that the unit be inspected regularly, in addition to your own cleaning and care. For more information, consult authorized service personnel.
When cleaning the unit’s body, do not use water hotter than 40 °C, harsh abrasive cleansers, or volatile agents like benzene or thinner.
Do not expose the unit body to liquid insecticides or hairsprays.
If the unit will not be operated for a period of one month or more, be sure to allow the inner parts of the unit to dry
thoroughly, in advance, by operating the unit in fan mode for half a day.
12
OPERATION DETAILS
Temperature and Humidity Range
Permissible range of temprature and humidity are as follows:
Operation and Performance
* Heating Performance
This air conditioner uses a heat pump which absorbs heat from outside air and brings it indoors. As a result, its heat­ing performance is reduced as the temperature of out­side air drops. If you find that insufficient room heat is produced, we recommend that you use the air conditioner together with other heating appliances.
Heat-pump type air conditioners use warm-air recirculation to warm your entire room. As a result, some time will be required after starting operation until your entire room becomes warm.
*
Microcomputer-controlled Automatic Defrosting
When the outside temperature is low and the humidity high, frost will collect on the outside unit, reducing heater effi­ciency. When this happens, the computer will automatically start the defrost cycle. During the defrost cycle, the indoor fan will shutdown and DEFROST will be displayed on the remote controller. It will take anywhere from 4 to 15 min­utes before the air conditioner starts up again.
*
When Indoor and Outdoor Temperatures are High
When both indoor and outdoor temperatures are high dur­ing use of the heating mode, the outdoor units fan may stop at times.
Instructions relating to heating (*) are applicable only to HEAT & COOL MODEL (Reverse Cycle).
Please read and understand the following details regarding this air conditioner.
Low Ambient Cooling
When the outdoor temperature drops, the outdoor unit’s fans may switch to Low Speed, or one of the fans may stop inter­mittently.
Should the power supply to the air conditioner be inter­rupted by a power failure, the air conditioner will restart automatically in the previously selected mode once the power is restored.
AUTO Restart
In Event of Power Interruption
Use of other electrical appliances (electric shaver, etc.) or nearby use of a wireless radio transmitter may cause the air conditioner to malfunction. In this event, temporarily turn off the circuit breaker turn it on again and then use the remote controller to resume operation.
Cooling Mode
About 0 to 46 °C
About 0 to 46 °C
About 18 °C to 30 °C
About 80 % or less
If the unit is used for long pe­riods under high-humidity conditions, condensation may form on the surface of the indoor unit, and drip onto the floor or other objects un­derneath.
*Heating Mode
About –10 to 21 °C
About below 30 °C
Outdoor temperature
Indoor temperature
Indoor humidity
COOLING MODEL
HEAT & COOL MODEL
(Reverse Cycle)
If the air conditioner is operated under higher temperature conditions than those listed, the built-in protection circuit may operate to prevent internal circuit damage. Also, during Cooling mode, if the unit is used under conditions of lower tem­peratures than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.
Do not use this unit for any purposes other than the Cooling, (*)Heating, Dehumidifying, and air-circulation of rooms in ordinary dwellings.
13
AUTO
TIMER MODE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
21
AUTO
DEFROST TEST
SET
ZONE
DAY OFF
ENERGY SAVE
If there is a problem with the air conditioner, it will stop run­ning and EE: EE will be displayed instead of the clock.
(1) If the operation lamp is on then press the START/
STOP button to turn it off.
(2) Press the SET TIME (▼) and the SET TEMP./DAY (▼)
buttons at the same time for more than three seconds to start the self diagnosis check. An error code will be displayed in the clock display area.
(3) Press the SET TIME (▼) and the SET TEMP./DAY (▼)
buttons again for more than three seconds to end the self diagnosis check.
ERRORS AND SELF DIAGNOSIS
Room temperature sensor shortcircuited
Indoor heat exchanger temperature sensor open
Indoor heat exchanger temperature sensor shortcircuited
Outdoor heat exchanger temperature sensor open
Outdoor heat exchanger temperature sensor shortcircuited
Power source connection error
Float switch operated
Outdoor temperature sensor open
Outdoor temperature sensor shortcircuited
Discharge pipe temperature sensor open
Discharge pipe temperature sensor shortcircuited
Outdoor high pressure abnormal
Discharge pipe temperature abnormal
Model abnormal
Indoor fan abnormal
Outdoor signal abnormal
Outdoor EEPROM abnormal
Error Code
Error Code
s
t
s
t
Error contents
Communication error (indoor unit remote controller)
Communication error (indoor unit outdoor unit)
Room temperature sensor open
TROUBLESHOOTING
Instructions relating to heating (*) are applicable only to HEAT & COOL MODEL (Reverse Cycle).
In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the elec­trical breaker, and consult authorized service personnel. Merely turning off the units power switch will not completely disconnect the unit from the power source. Always be sure to turn off the electrical breaker to ensure that power is completely off.
Before requesting service, perform the following checks:
WARNING!
Symptom
Doesnt operate immedi­ately:
Problem
If the unit is stopped and then immediately started again, the com­pressor will not operate for about 3 minutes, in order to prevent fuse blowouts.
Whenever the electrical breaker is turned off then on again, the protection circuit will operate for about 3 minutes, preventing unit operation during that period.
See Page
NORMAL
FUNCTION
14
Noise is heard:
Smells:
Mist or steam are emitted:
Air flow is stops:
Water is produced from the outdoor unit:
During operation and immediately after stopping the unit, the sound of water flowing in the air conditioners piping may be heard. Also, noise may be particularly noticeable for about 2 to 3 minutes after starting operation (sound of coolant flowing).
*During Heating operation, a sizzling sound may be heard occa-
sional. This sound is produced by the Automatic Defrosting op­eration.
Some smell may be emitted from the indoor unit. This smell is the result of room smells (furniture, tobacco, etc.) which have been taken into the air conditioner.
During Cooling, a thin mist may be seen emitted from the indoor unit. This results from the sudden Cooling of room air by the air emitted from the air conditioner, resulting in condensation and misting.
*During Heating operation, the outdoor units fan may stop, and
steam may be seen rising from the unit. This is due to Automatic Defrosting operation.
*When Heating operation is started, fan is temporarily stop, to al-
low internal parts to warm up.
*During Heating operation, if the room temperature rises above
the thermostat setting, the indoor and the outdoor unit will stop. If you wish to warm the room further, set the thermostat for a higher setting.
*During Heating operation, the unit will temporarily stop opera-
tion (between 2 and 16 minutes) as the Automatic Defrosting mode operates. During Automatic Defrosting operation, DEFROST will be shown on the remote controller display.
The fan may stop when the unit is monitoring the room’s tem- perature.
*During Heating operation, water may be produced from the out-
door unit due to Automatic Defrosting operation.
12
12
12
12
NORMAL
FUNCTION
Symptom
Doesnt operate at all:
Poor Cooling (or *Heating) performance:
See Page
4
CHECK ONCE
MORE
Items to check
Has there been a power failure?
Has a fuse blown out, or a circuit breaker been tripped?
Is the timer operating?
Is the air filter dirty?
Are the air conditioners intake grille or outlet port blocked?
Did you adjust the room temperature settings (thermostat) cor-
rectly?
Is there a window or door open?
In the case of Cooling operation, is a window allowing bright sun-
light to enter? (Close the curtains.)
In the case of Cooling operation, are there heating apparatus and computers inside the room, or are there too many people in the room?
If the problem persists after performing these checks, or if you notice burning smells, stop operation immediately, turn off the electrical breaker, and consult with authorized service personnel.