ERROR CONTENTS
INDOOR UNIT
17
2008.04.23
Troubleshooting at the indoor unit display
(Troubleshooting at the display is available
either on the wired or wireless remote control.)
Troubleshooting at the wired remote control LCD
Self diagnosis
F ILT E R LAMP
T IME R L AMP
OP E R ATION LA MP
MAN UAL AU TO
If an error occurs, the following display will be shown.
("EE" will appear in the set room temperature display.)
Unit number
Error code
Ex. Self-diagnosis
Indoor signal error
Wired re mote controller a bnorma l
Indoor room temperature s ensor e rror
Indoor heat excha nger temperature
sens or (middle) error
Indoor heat excha nger temperature
sens or (inlet) error
F loa t switch ope rated
Outdoor dis charge pipe tempe rature
sens or error
Outdoor heat excha nger temperature
sens or (outlet) error
Outdoor tempe rature s ens or error
C ompress or temperature sens or error
2-wa y valve temperature s ensor error
3-wa y valve temperature s ensor error
Outdoor heat excha nger temperature
sens or (middle) error
Indoor manual auto s witc h abnorma l
P ower s upply freque ncy de tection error
IP M protection
C T error
C ompress or location error
Outdoor fa n error
C onnected indoor unit a bnorma l
Outdoor unit c omputer communication
error
Indoor fa n abnorma l
Dis charge temperature error
E xes sive high pres sure prote ction on
cooling
4-wa y valve abnorma l
P ress ure switch abnormal
C ompress or temperature error
Active filter a bnormal
P FC circ uit error
E rro r c onte nts
OP E R AT ION
la mp ( Green )
(2 times)
(2 times)
(2 times)
(2 times)
(3 times)
(3 times)
(3 times)
(3 times)
(3 times)
(3 times)
(3 times)
(4 times)
(4 times)
(5 times)
(5 times)
(5 times)
(5 times)
(5 times)
(5 times)
(6 times)
(7 times)
(7 times)
(7 times)
(7 times)
(7 times)
(8 times)
(8 times)
TIME R lamp
(O ran ge)
(8 times)
(2 times)
(3 times)
(4 times)
(6 times)
(2 times)
(3 times)
(4 times)
(8 times)
(2 times)
(4 times)
(2 times)
(3 times)
(5 times)
(6 times)
(7 times)
(8 times)
(2 or 3 times )
(2 times)
(3 times)
(4 times)
(5 times)
(6 times)
(2 or 3 times )
(4 times)
F ILT E R lamp
(R ed )
(2 times)
(3 times)
(4 times)
: 0.5s O N/0.5s O FF (F las h)
The OPERATION, TIMER and FILTER lamp operate as follows table
according to the error contents.
S UMOTUWETH F R
S A
E rro r c ode E rro r c onte nts
Indoor signal error
Wired re mote controller a bnorma l
Indoor room temperature s ensor e rror
Indoor heat excha nger temperature sens or (middle) e rror
Indoor heat excha nger temperature sens or (inle t) error
F loa t switch ope rated
Outdoor dis charge pipe tempe rature s ens or error
Outdoor heat excha nger temperature sens or (outlet) error
Outdoor tempe rature s ens or error
C ompress or temperature sens or error
2-wa y valve temperature s ensor error
3-wa y valve temperature s ensor error
Outdoor heat excha nger temperature sens or (middle) error
Indoor manual auto s witc h abnorma l
P ower s upply freque ncy de tection error
IP M protection
C T error
C ompress or location error
Outdoor fa n error
C onnected indoor unit a bnorma l
Outdoor unit c omputer communication error
Indoor fa n abnorma l
Dis charge temperature error
E xes sive high pres sure prote ction on cooling
01
13
26
27
00
02
04
28
09
0C
06
0A
15
1d
1E
29
20
2A
17
18
1A
1b
1F
1c
12
0F
24
2c
16
2b
19
25
If "C O" appea rs in the unit number dis play, there is a remote controller
error. R efer to the ins ta lla tion instruction sheet include d with the remote
controller.
: OF F
(R E D)
(O RANG E )
(G R E EN )