Fujitsu AS*G24LFCC, AO*G24LFCC Design & Technical Manual

AIR CONDITIONER
Wall Mounted type
INDOOR
OUTDOOR
ASG18LFCA ASG24LFCC ASG30LFCA
AOG18LFC
AOG24LFCC
AOG30LFT
DESIGN & TECHNICAL MANUAL
1. INDOOR UNIT
WALL MOUNTED TYPE :
ASG18LFCA ASG24LFCC ASG30LFCA
DTR_AS075E_04
2016.04.22
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
CONTENTS
1. INDOOR UNIT
1. FEATURES
.............................................................................................................. 01 - 01
2. WIRELESS REMOTE CONTROLLER
............................................... 01 - 04
3. SPECIFICATIONS
..............................................................................................01 - 06
4. DIMENSIONS
........................................................................................................01 - 08
5. WIRING DIAGRAMS
........................................................................................01 - 10
6. CAPACITY TABLE
.............................................................................................01 - 11
6-1. COOLING CAPACITY
.......................................................................................01 - 11
6-2. HEATING CAPACITY
.......................................................................................01 - 12
7. FAN PERFORMANCE
.................................................................................... 01 - 13
7-1. AIR VELOCITY DISTRIBUTION
..................................................................... 01 - 13
7-2. AIRFLOW
........................................................................................................... 01 - 15
8. OPERATION NOISE (SOUND PRESSURE)
................................. 01 - 18
8-1. NOISE LEVEL CURVE
....................................................................................01 - 18
8-2. SOUND LEVEL CHECK POINT
..................................................................... 01 - 20
9. ELECTRICAL CHARACTERISTICS
................................................... 01 - 21
10. SAFETY DEVICES
............................................................................................ 01 - 22
11. EXTERNAL INPUT & OUTPUT
............................................................... 01 - 23
11-1. EXTERNAL INPUT
...........................................................................................01 - 23
11-2. EXTERNAL OUTPUT
.......................................................................................01 - 25
12. FUNCTION SETTINGS
.................................................................................. 01 - 26
12-1. INDOOR UNIT (Setting by remote controller)
...........................................01 - 26
13. OPTIONAL PARTS
...........................................................................................01 - 30
13-1. CONTROLLERS
............................................................................................... 01 - 30
13-2. OTHERS
............................................................................................................. 01 - 30
- (01 - 01) -
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
FEATURES1.
MODEL
AS
G18LFCA
AS
G24LFCC
AS
G30LFCA
FEATURES
Energy efciency class
z
MODEL
ASG18LFCA ASG24LFCC ASG30LFCA Cooling A++ A++ A+ Heating A A A
All DC
z
Large airflow and quiet operation by new airflow path
High efficiency layout
DC fan motor
DC compressor
Super quiet
z
Airow mode can be set in 4 steps and more detailed airow setting is possible.
Easy maintenance
z
Easy maintenance and always clean. Troublesome maintenance has been made easy.
Since the front panel is easy to remove, maintenance is also easy.
10°C HEAT Operation
z
The room temperature can be set to go no lower than 10 °C,
thus ensuring that the room does not get too cold when not occupied
Caution)
When the room temperature is higher than 10 °C, “10°C HEAT” operation will not start. Operation starts and maintains the room
temperature at 10 °C when the temperature drops below 10 °C.
10
°C
20
°C
“10°C HEAT”
Button ON
Indoor unit operation START
“10°C HEAT”
Button ON
AO
G18LFC
AOG24LFCC
AO
G30LFT
- (01 - 02) -
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
Power diffuser
z
Adoption of large power diffuser
16
Outside air conditions: 2
o
C
o
C
60%
( C)
Operation contents Operating mode: Heating Set temperature (Max. set temp): 30
o
2933 32 31 30
Airflow : Hi Vertical airflow direction louver: Downward Horizontal airflow direction louver: Center
2.1
1
0
3 6 9 12
(m)
(m)
Power diffuser
(full open)
46
o
“Strong vertical airow” provides powerful oor level heating.
“Healthy horizontal airow” does not blow cool air directly at the occupants in the room.
Outside air conditions: 35 oC 40%
( C)
Operation contents Operating mode: Cooling Set temperature (Min. set temp):
o
18oC
1815 16 17
2.1
1
0
3 6 9 12
(m)
(m)
Vertical airflow direction louver: Upward Horizontal airflow direction louver: Center
Power diffuser
Low outdoor air temperature cooling and heating correspondence
z
Corresponds to cooling operation at -10 °C and heating operation at -15 °C outdoor air temperature
Cooling
-10 °C
Heating
-15 °C
Corresponds to maximum 50m-long piping (30 type)
z
- (01 - 03) -
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
Air conditioner lter features
z
Organic coating fin used heat exchanger
Air Filter
Ion Deodorization Filter
Apple-catechin Filter
Apple-catechin Filter
Ion Deodorization Filter
Economy operation
z
Example: Cooling operation
Economy operation is energy saving, as
the set temperature of indoor unit is shifted by 1 °C and the maximum electric value of the outdoor unit is suppressed.
Temp.
Economy operation
Shift
setting
temp
Control maximum current
Normal operation
Time
Set temperature
Blue n heat exchanger (30 type)
z
Corrosion-resistance of the heat exchanger even in coastal areas has been improved by blue n treatment of the outdoor unit heat exchanger.
Blue n heat exchanger
Cobalt Blue protection
Standard chromate protection Aluminium base material
Hydrophilic coating
- (01 - 04) -
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
WIRELESS REMOTE CONTROLLER2.
FEATURES
Simple function setting
z
Setting of the air conditioner selection function is performed by remote controller.
Built-in timers
z
Select from 4 different timer programs (ON / OFF / PROGRAM / SLEEP).
Program timer
z
The program timer operates the on and off timer once within a 24-hour period.
Sleep timer
z
The sleep timer function automatically corrects the temperature thermostat setting according to the time setting to prevent excessive cooling and heating while sleeping.
60min.
1°C
2°C
Timer setting
1°C
2°C
3°C
4°C
30min.
60min.
90min.
Timer setting
Cooling operation / dry operation
When the sleep timer is set, the set temperature automatically rises 1 °C every hour. The set temperature can rise up to a maximum of 2 °C.
Heating operation
When the sleep timer is set, the set temperature automatically drops 1 °C every 30 minutes. The set temperature can drop to a maximum of 4 °C.
Switching remote controller custom code
z
Code selector switch eliminates unit
being wrongly switched.
(Up to 4 codes can be set.)
*I.U.=Indoor unit
A B C D
A B
C
D
Mixed-up
I.U. I.U. I.U. I.U.
I.U. I.U. I.U. I.U.
After code change
4 mode timer setup available (ON / OFF / PROGRAM / SLEEP). Can be used jointly with wired remote controllers . Easy to change custom code (max. 4 units) by button operation.
- (01 - 05) -
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
FUNCTIONS
MODE button1
Selects the operating mode (AUTO, COOL, DRY, FAN, HEAT). /Start / end R.C. custom code change. (Max 4 types)
10°C2
HEAT button
SET TEMP. button ( ▲ / ▼ )3
Set remote controller custom code buttons Sets the indoor temp./ Sets R.C. custom code.
ECONOMY button4 SLEEP button5
Pressed to select sleep timer.
FAN button6
Selects the fan speed (AUTO, HIGH, MED, LOW, QUIET).
START/STOP button7
Pressed to start and stop operation.
SET button (Vertical)8
Airow direction vertical set button.
SET button (Horizontal)9
Airow direction horizontal set button.
SWING button10
Airow direction swing button.
TIMER MODE button11
Pressed to select the timer mode. (OFF TIMER, ON TIMER, PROGRAM TIMER, TIMER RESET)
TIMER set ( / ) button12
Sets the current time and on-off time.
CLOCK ADJUST button13
Sets the current time.
RESET button14
Used when replacing batteries.
TEST RUN button15
Used when testing the air conditioner after installation.
Signal transmitter16 Temperature set indicator17 Operating mode indicator18 Sleep indicator19 Transmit indicator20 Fan speed indicator21 Swing indicator22 Timer mode indicator23 Clock indicator24
Display panel
NOTE:
Functions will be different due to type of indoor unit.
For details, refer to the operation manual.
+
-
SPECIFICATION
SIZE (H × W × D mm) 170 × 56 × 19 WEIGHT (g) 85 (w/o batteries)
ACCESSORY Holder
2
4
9
3
1
16
15
5
10
13
11
12
14
8
7
6
17
18
19
21
24
23
22
20
- (01 - 06) -
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
SPECIFICA TIONS3.
Typ e
WALL MOU NTED
INVERT ER HEAT PUM P
Model na me AS
G18LFCA ASG24LFCC ASG30LFCA
Power source 230 V~ 50 Hz Available voltage range 198 –26 4V
Capacity
Cooling
Rated
kW 5.20 7.10 8.00
Btu/h 17,700 24,200 27, 3 00
Min.–Max.
kW 0.9–6.0 0.9– 8 .0 2.9–9.0
Btu/h 3,100–20,500 3,100–27,300 9,900–30,700
Heating
Rated
kW 6.30 8.00 8.80
Btu/h 21,500 27, 30 0 30,000
Min.–Max.
kW 0.9–9.1 0.9–10.6 2.2–11.0
Btu/h 3,100–31,000 3,100–36,200 7,5 00 – 37, 60 0
Input power
Cooling
Rated
kW
1.52 2.20 2.49
Min.–Max. 0.09–2.07 0.30–3.07 0.58–3.87
Heating
Rated 1.71 2.21 2.44 Min.–Max. 0.09–2.87 0.28–4.21 0.50–4.33
Current
Cooling
Rated A
6.8 9.7 10.9
Heating 7.6 9.7 10.7
EER Cooling
kW/kW
3.42 3.23 3.21
COP Heating 3.68 3.61 3.61 Sensibl e capac ity Cooling kW 3.45 5.25 6.00
Power fact or
Cooling
%
97 99 99
Heating 98 99 99
Moisture removal l/h (pints/h) 2.6(4.6) 2.7(4.8) 3.2(5.6) Maximum operat ing
current *
Cooling
Max. A
9.0 13.5 17.0
Heating 12.5 18.5 19.0
Fan
Airow rate
Cooling
High
m
3
/h
900 1120 1100
Med 740 900 900
Low 620 740 740
Quiet 550 580 620
Heating
High 900 1120 1150 Med 740 900 900
Low 620 740 740
Quiet 550 580 620
Type × Q'ty Cross ow fan × 1 Motor out put W 42 65 42
Sound pressure level
Cooling
High
dB (A)
43 49 48
Med 37 42 42
Low 33 37 37
Quiet 26 32 33
Heating
High 42 48 49 Med 37 42 42
Low 33 37 37
Quiet 25 32 33
Heat exchanger type
Dimensions
(H × W × D)
mm
Main : 378 × 832 × 26.6
Sub : 84 × 832 × 13.3
Main : 378 × 832 × 26.6
Sub1 : 84 × 832 × 13.3,
Sub2 : 84 × 83 2 × 13.3
Fin pitch Main :1.2, Sub :1.4 Main : 1.2, Sub1 : 1.4, Sub2 : 1.4 Rows × stag es Main : 2 × 18, Sub :1 × 4 Main : 2 × 18, Sub1 : 1 × 4, Sub2 : 1 × 4 Pipe typ e Copper Fin type Aluminium
Enclosure
Material Polystyrene
Colour
White
Approximate colour of MU NSELL N 9.25/
Dimensions
(H × W × D)
Net
mm
320 × 998 × 238
Gross 329 × 1090 × 420
Weight
Net
kg
14
Gross 18
Connec tion pipe
Size
Liquid
mm
Ø 6.35 (Ø 1/4 in.) Ø 6.35 (Ø 1/4 in.) Ø 9.52 (Ø 3/8 in.)
Gas Ø 12.70 (Ø 1/2 in.) Ø 15.88 (Ø 5/8 in.) Ø 15.88 (Ø 5/8 in.)
Method Flare
Operat ion rang e
Cooling
°C 18 to 32
%RH 80 or less
Heating °C 30 or less
Remote co ntroller type Wireless
Drain ho se
Material PVC Size mm Ø 12 (I.D.), Ø 16 (O.D.)
NOTES:
l
Specications are based on the following conditions: Cooling : Indoor temperature of 27 °CDB/19 °CW B and outdoor temperature of 35 °CDB/24 °CWB Heating : Indoor temperature of 20 °CDB/15 °CWB and outdoor temperature of 7 °CDB/6 °CWB Pipe length : 5 m, Height difference : 0 m (Outdo or unit–Indoor unit)
l
The protective function might work when using it in environment out of the temperature range mentioned above. * : The maximum current is the ma ximum value when operated within the operation range.
- (01 - 07) -
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
Model na me ASG18LFCA ASG24LFCC ASG30LFCA
Energy ef cie ncy clas s
Cooling A++ A++ A+
Heating (Average) A A A
Pdesign
Cooling
kW
5.2 (35 °C) 7.1 (35 °C) 8.0 (35 °C)
Heating (Average) 5.9 (-10 °C) 7.1 (-10 °C) 8.0 (-10 °C)
SEER Cooling
kWh/kWh
6.94 6.11 5.69
SCOP Heating (Average) 3.87 3.80 3.80
Annual energy co nsumpti on
QCE
kWh/a
262 406 492
QHE (Average) 2130 2610 2941
Sound power level
Cooling
High dB (A)
58 64 64
Heating 58 64 64
- (01 - 08) -
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
DIMENSIONS4.
MODEL : ASG18LFCA, ASG24LFCC, ASG30LFCA
(Unit : mm)
AS
G18LF ASG24LF ASG30LF
Refrigerant pipe are
connection
Liquid ø 6.35 mm (1/4 in.) ø 9.52 mm (3/8 in.)
Gas ø 12.7 mm (1/2 in.) ø 15.88 mm (5/8 in.)
Drain hose connection Drain hose
Ø12 (I.D.), Ø16 (O.D.)
Drain hose : L=670 mm
998
439
438
397
320: Unit size
269
20
37
26 x 11 hole
5 x 18: 14holes
21 x 5: 14holes
5 x 50: 3holes
13 x 5: 4holes
ø 80 hole
ø 5: 65holes
998: Unit size
Piping inlet
for tapping screw
18 x 11 hole
18 x 11 hole
122
172
75
387
170
16
400
Unit center
126
133
130
113
75
243
238
320
520
520
590
721
ø 80 hole
Piping inlet
30
30
149
197
272
44
12
13
26 x 11 hole
25
ø 32
ø 16
ø 12
- (01 - 09) -
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
INSTALLATION PLACE
(Unit : mm)
63 or more
80 or more
53 or more
52 or more
80 or more
Outline of unit
120 or more
1500 or more
1800 or more
- (01 - 10) -
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
WIRING DIAGRAMS5.
MODEL : ASG18LFCA, ASG24LFCC, ASG30LFCA
TO OUTDOOR UNIT
CONTROOL BOARD
TEST
CN13
CN14
2 1
CN16
EX.OUT (OPTION)
EX.IN (OPTION)
1
2
3
BLACK WHITE
RED
REMOTE CONTROL
UNIT (OPTION)
3 2 1
- (01 - 11) -
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
CAPACITY TABLE6.
COOLING CAPACITY6-1.
MODEL : ASG18LFCA
MODEL
: ASG24LFCC
MODEL
: ASG30LFCA
AFR : Air ow Rate (m3/min) TC : Total Capaci ty (kW) SHC : Sens ible Hea t Capacit y (kW) IP : Input Pow er (kW)
AFR 15.0
Indoor temperature
°CDB 18 21 23 25 27 29 32
°CWB 12 15 16 18 19 21 23
Outdoor temperature
°CDB TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP
20 4.62 3.14 1.03 5.15 3.15 1.05 5.33 3.43 1.05 5.68 3.44 1.06 5.85 3.71 1.07 6.20 3.70 1.08 6.56 3.94 1.09 25 4.63 3.14 1.17 5.16 3.16 1.19 5.34 3.43 1.20 5.69 3.45 1.21 5.86 3.72 1.22 6.21 3.71 1.23 6.57 3.95 1.24 30 4.38 2.97 1.32 4.88 2.99 1.34 5.04 3.25 1.35 5.38 3.26 1.36 5.54 3.52 1.37 5.87 3.50 1.38 6.21 3.73 1.39 35 4.11 2.91 1.47 4.58 2.93 1.49 4.73 3.18 1.50 5.04 3.19 1.51 5.20 3.45 1.52 5.51 3.44 1.54 5.82 3.66 1.55 40 3.56 2.41 1.35 3.96 2.43 1.38 4.10 2.64 1.38 4.37 2.65 1.40 4.50 2.86 1.40 4.78 2.85 1.42 5.05 3.03 1.43 46 3.08 2.09 1.65 3.43 2.10 1.68 3.55 2.28 1.68 3.78 2.29 1.70 3.90 2.48 1.71 4.13 2.47 1.73 4.37 2.63 1.74
AFR 18.7
Indoor temperature
°CDB 18 21 23 25 27 29 32
°CWB 12 15 16 18 19 21 23
Outdoor temperature
°CDB TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP
20 5.72 4.53 1.17 6.37 4.56 1.19 6.59 4.96 1.19 7.02 4.97 1.20 7.24 5.37 1.21 7.67 5.35 1.22 8.11 5.70 1.23 25 6.41 4.90 1.84 7.15 4.93 1.87 7.39 5.36 1.88 7.88 5.38 1.90 8.12 5.81 1.91 8.61 5.79 1.93 9.09 6.16 1.95 30 6.19 4.71 2.02 6.90 4.74 2.05 7.13 5.15 2.06 7.60 5.17 2.08 7.84 5.58 2.09 8.31 5.56 2.11 8.78 5.92 2.13 35 5.61 4.43 2.09 6.25 4.46 2.13 6.46 4.85 2.14 6.89 4.86 2.16 7.10 5.25 2.21 7.53 5.23 2.19 7.95 5.57 2.21 40 5.08 4.11 2.08 5.66 4.13 2.12 5.85 4.50 2.13 6.24 4.51 2.15 6.43 4.87 2.16 6.82 4.85 2.18 7.20 5.17 2.20 46 4.62 3.88 2.24 5.15 3.91 2.27 5.32 4.25 2.29 5.68 4.26 2.31 5.85 4.60 2.32 6.20 4.58 2.34 6.55 4.88 2.37
AFR 18.3
Indoor temperature
°CDB 18 21 23 25 27 29 32
°CWB 12 15 16 18 19 21 23
Outdoor temperature
°CDB TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP
20 6.31 5.01 1.29 7.03 5.04 1.31 7.27 5.48 1.32 7.75 5.50 1.33 7.99 5.94 1.34 8.47 5.92 1.35 8.95 6.30 1.37 25 6.99 5.45 2.03 7.79 5.48 2.06 8.05 5.96 2.07 8.58 5.98 2.09 8.85 6.46 2.10 9.38 6.43 2.12 9.91 6.85 2.14 30 6.66 5.23 2.26 7.42 5.26 2.29 7.67 5.72 2.30 8.18 5.74 2.33 8.43 6.20 2.34 8.94 6.18 2.36 9.44 6.58 2.39 35 6.32 5.06 2.40 7.04 5.09 2.44 7.28 5.54 2.45 7.76 5.56 2.48 8.00 6.00 2.49 8.48 5.98 2.51 8.96 6.37 2.54 40 5.68 4.63 2.68 6.33 4.66 2.72 6.54 5.07 2.74 6.97 5.08 2.77 7.19 5.49 2.78 7.62 5.47 2.81 8.05 5.82 2.84 46 5.17 4.22 2.89 5.76 4.25 2.93 5.96 4.62 2.95 6.35 4.63 2.98 6.55 5.00 2.99 6.94 4.98 3.02 7.34 5.31 3.05
- (01 - 12) -
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
HEATING CAPACITY6-2.
MODEL : ASG18LFCA
MODEL
: ASG24LFCC
MODEL
: ASG30LFCA
AFR: Air ow Rate (m3/min) TC : Total Capaci ty (kW) IP : Input Pow er (kW)
AFR 15.0
Indoor t empera ture
16 18 20 22 24
Outdoo r temper ature
(°CD B) (°CWB) TC IP TC IP TC IP TC IP TC IP
-15 -16 5.08 2.19 4.96 2.24 4.84 2.30 4.72 2.33 4.60 2.37
-10 -11 6.04 2.36 5.89 2.42 5.75 2.47 5.61 2.52 5.47 2.57
-5 -7 6.81 2.48 6.64 2.54 6.48 2.59 6.32 2.64 6.16 2.69 0 -2 7.86 2.65 7.67 2.72 7.48 2.77 7.29 2.83 7.11 2.89 5 3 8.94 2.83 8.72 2.90 8.51 2.96 8.30 3.01 8.09 3.08 7 6 9.56 2.75 9.33 2.82 9.10 2.87 8.87 2.92 8.65 2.99
10 8 9.91 2.75 9.66 2.82 9.43 2.87 9.19 2.92 8.97 2.99 15 10 9.59 2.38 9.36 2.44 9.13 2.49 8.90 2.54 8.68 2.59
AFR 18.7
Indoor t empera ture
16 18 20 22 24
Outdoo r temper ature
(°CD B) (°CWB) TC IP TC IP TC IP TC IP TC IP
-15 -16 6.41 2.81 6.26 2.87 6.11 2.93 5.95 2.99 5.80 3.05
-10 -11 7.30 3.00 7.13 3.06 6.96 3.12 6.78 3.18 6.61 3.25
-5 -7 8.23 3.23 8.04 3.29 7.84 3.36 7.64 3.43 7.45 3.49 0 -2 9.05 3.50 8.84 3.58 8.62 3.65 8.40 3.72 8.19 3.80 5 3 10.05 3.82 9.81 3.90 9.57 3.98 9.33 4.06 9.09 4.14 7 6 11.13 3.89 10.87 3.97 10.60 4.06 10.34 4.14 10.07 4.22
10 8 11.19 3.38 10.93 3.45 10.66 3.52 10.39 3.59 10.13 3.66 15 10 10.71 2.90 10.46 2.96 10.20 3.02 9.95 3.08 9.69 3.13
AFR 19.2
Indoor t empera ture
16 18 20 22 24
Outdoo r temper ature
(°CD B) (°CWB) TC IP TC IP TC IP TC IP TC IP
-15 -16 7.75 4.07 7.56 4.16 7.38 4.24 7.20 4.32 7.01 4.41
-10 -11 8.34 4.06 8.14 4.15 7.94 4.23 7.74 4.31 7.54 4.40
-5 -7 9.61 4.08 9.38 4.17 9.15 4.25 8.92 4.34 8.69 4.42 0 -2 10.54 4.04 10.29 4.13 10.04 4.21 9.79 4.29 9.54 4.38 5 3 11.53 4.09 11.25 4.17 10.98 4.26 10.71 4.35 10.43 4.43 7 6 11.55 3.39 11.28 3.46 11.00 3.53 10.73 3.60 10.45 3.67
10 8 11.90 3.38 11.61 3.45 11.33 3.52 11.05 3.59 10.76 3.66 15 10 11.48 2.95 11.20 3.01 10.93 3.07 10.66 3.13 10.38 3.19
- (01 - 13) -
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
FAN PERFORMANCE7.
AIR VELOCITY DISTRIBUTION7-1.
MODEL : ASG18LFCA
Conditions:
Fan speed : HIGH
Operation mode : FAN
Voltage : 230 V
2
1
0
1
2
(m)
(m)
Unit : m/s
0 1 2 3 4 5 6 7 8
3
2
1
0
1
2
3
(m)
(m)
Unit : m/s
0 1 2 3 4 5 6 7 8
3
2
1
0
(m)
(m)
Unit : m/s
0 1 2 3 4 5 6 7 8
3
2
1
0
(m)
(m)
Unit : m/s
0 1 2 3 4 5 6 7 8
Side view Vertic al air ow direction lou ver : Down Horizo ntal air ow direction l ouver : Cent er
2.0
1.0
0.5
Side view Vertic al air ow direction lou ver : Up Horizo ntal air ow direction l ouver : Cent er
2.0
1.0
0.5
Top view Vertic al air ow direction lou ver : Up Horizo ntal air ow direction l ouver : Rig ht & Left
1.0
1.0
0.5
0.5
2.0
Top view Vertic al air ow direction lou ver : Up Horizo ntal air ow direction l ouver : Cent er
2.0 1.0 0.5
- (01 - 14) -
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
WALL MOUNTED TYPE
AS
G18-30LFC(C)A
MODEL : ASG24LFCC, ASG30LFCA
Conditions:
Fan speed : HIGH
Operation mode : FAN
Voltage : 230 V
2
1
0
1
2
(m)
(m)
Unit : m/s
0 1 2 3 4 5 6 7 8
3
2
1
0
1
2
3
(m)
(m)
Unit : m/s
0 1 2 3 4 5 6 7 8
3
2
1
0
(m)
(m)
Unit : m/s
0 1 2 3 4 5 6 7 8
3
2
1
0
(m)
(m)
Unit : m/s
0 1 2 3 4 5 6 7 8
Side view Vertic al air ow direction lou ver : Down Horizo ntal air ow direction l ouver : Cent er
2.0
1.0
0.5
Side view Vertic al air ow direction lou ver : Up Horizo ntal air ow direction l ouver : Cent er
2.0
1.0
0.5
Top view Vertic al air ow direction lou ver : Up Horizo ntal air ow direction l ouver : Rig ht & Left
1.0
1.0
0.5
0.5
2.0
Top view Vertic al air ow direction lou ver : Up Horizo ntal air ow direction l ouver : Cent er
2.0 1.0 0.5