GUARDE ESTE MMANUAL DE FUNCIONANENTO
PARA REFERÊNCIA FUTURA
P/N9317433037-03
Fig. 1
Fig. 5
0
F
A
B
C
1
1
2
8
9
Fig.2
1
3
3
OPERATION
TIMER
SUPER QUIET
5
6
7
DE
4
Fig.3
8
Fig. 6
G
H
J
I
Fig.4
C
C
Fig. 7
To facilitate explanation, the accompanying illustration
has been drawn to show all possible indicators; in actral
operation, however, the display will only show those
indicators appropriate to the current operation.
● Do not attempt to install this air conditioner by yourself.
● This air conditioner contains no user-serviceable parts. Always consult authorized
service personnel for repairs.
● When moving, consult authorized service personnel for disconnection and installation
of the air conditioner.
● Do not become excessively chilled by staying for many hours in the direct cooling
airfl ow.
● Do not insert fi ngers or objects into the outlet port or intake grille.
● Do not start and stop air conditioner operation by disconnecting the power supply
cord and so on.
● Take care not to damage the power supply cord.
● In the event of a malfunction (burning smell, etc.), immediately stop operation,
disconnect the power supply plug, and consult authorized service personnel.
● If the power supply cord of this appliance is damaged, it should only be replaced by
the authorized service personal, since special purpose tools and specifi ed cord are
required.
MANUAL AUTO OPERATION ...............................En-8
ADJUSTING THE DIRECTION OF
AIR CIRCULATION ...............................................En-9
● Do not direct airfl ow at fi replaces or heating apparatus.
● Do not climb on, or place objects on, the air conditioner.
● Do not hang objects from the indoor unit.
● Do not set fl ower vases or water containers on top of air conditioners.
● Do not expose the air conditioner directly to water.
● Do not operate the air conditioner with wet hands.
● Do not pull power supply cord.
● Turn off power supply when not using the indoor unit for extended periods.
● Check the condition of the installation stand for damage.
● Do not place animals or plants in the direct path of the airfl ow.
● Do not drink the water drained from the air conditioner.
● Do not use in applications involving the storage of foods, plants or animals, precision
equipment, or art works.
● Connection valves become hot during Heating; handle with care.
● Do not apply any heavy pressure to radiator fi ns.
● Operate only with air fi lters installed.
● Do not block or cover the intake grille and outlet port.
● Ensure that any electronic equipment is at least one meter away from either the indoor
or outdoor units.
● Avoid installing the air conditioner near a fi replace or other heating apparatus.
● When installing the indoor and outdoor unit, take precautions to prevent access to
infants.
● Do not use infl ammable gases near the air conditioner.
En-1
FEATURES AND FUNCTIONS
INVERTER
At the start of operation, a large power is used to bring the room
quickly to the desired temperature. Afterward, the air conditioner
automatically switches to a low power setting for economic and
comfortable operation.
AUTO CHANGEOVER
The operation mode (cooling, dry) is switched automatically
to maintain the set temperature, and the temperature is kept
constant at all times.
PROGRAM TIMER
The program timer allows you to integrate OFF timer and ON
timer operations in a single sequence. The sequence can involve
one transition from OFF timer to ON timer, or from ON timer to
OFF timer, within a twenty-four hour period.
SLEEP TIMER
When the SLEEP button is pressed during cooling mode, the
thermostat setting is gradually raised during the period of operation. When the set time is reached, the indoor unit automatically
turns off.
WIRELESS REMOTE CONTROL UNIT
The Wireless Remote Control Unit allows convenient control of
indoor unit operation.
SWING OPERATION
The Air Flow Direction Louvers swings automatically up and down
so that the air speeds to every nook and corner of your room.
REMOVABLE INTAKE GRILLE
The indoor unit’s Intake Grille can be removed for easy cleaning
and maintenance.
MILDEW-RESISTANT FILTER
The AIR FILTER has been treated to resist mildew growth, thus
allowing cleaner use and easier care.
SUPER QUIET OPERATION
When the FAN CONTROL button is used to select QUIET, the
indoor unit begins super-quiet operation; the indoor unit’s airfl ow
is reduced to produce quieter operation.
POLYPHENOL CATECHIN AIR CLEANING FILTER
The polyphenol catechin air cleaning fi lter uses static electricity
to clean fi ne particles and dust in the air such as tobacco smoke
and plant pollen that are too small to see.
The fi lter contains catechin, which is highly effective against
various bacteria by suppressing the growth of the bacteria adsorbed to the fi lter.
Note that when the air cleaning fi lter is installed, the amount of
air produced decreases, causing a slight decrease in the indoor
unit’s performance.
NEGATIVE AIR IONS DEODORIZING FILTER
It comprises pottery super micro particles which can produce
negative air ions having the effect of deodorizing and can absorb
and remit the peculiar smell at home.
En-2
NAME OF PARTS
Fig. 1 Indoor Unit
1 Operating Control Panel (Fig. 2)
2 MANUAL AUTO button
When kept on pressing the MANUAL AUTO
●
button for more than 10 seconds, the forced
cooling operation will start.
●The forced cooling operation is used at the
time of installation.
Only for authorized service personnel’s use.
●When the forced cooling operation starts by
any chance, press the START/STOP button
to stop the operation.
3 Indicator (Fig. 3)
4 Remote Control Signal Receiver
5 OPERATION Indicator Lamp (green)
6 TIMER Indicator Lamp (orange)
If the TIMER indicator lamp fl ashes when the
●
timer is operating, it indicates that a fault has
occurred with the timer setting (See Page 14
Auto Restart).
7 SUPER QUIET Indicator Lamp (yellow)
8 Intake Grille (Fig. 4)
9 Front Panel
0 Air Filter
A Air Flow Direction Louver
B Right-Left Louver
(behind Air Flow Direction Louver)
C Drain Hose
D Power Supply Plug
E Power Supply Cord
F Air Cleaning Filter
Fig. 5 Outdoor Unit
G Intake Port
H Outlet Port
I Pipe Unit
J Drain port (bottom)
Fig. 6 Remote Control Unit
K Signal Transmitter
L MASTER CONTROL button
M SLEEP button
N TIMER MODE button
O FAN CONTROL button
P START/STOP button
Q SET TEMP. button (
/ )
R SET button
S SWING button
T TIMER SET ( / ) button
U CLOCK ADJUST button
V TEST RUN button
● This button is used when installing the conditioner, and should not be used under normal
conditions, as it will cause the air conditioner’s
thermostat function to operate incorrectly.
● If this button is pressed during normal operation, the unit will switch to test operation mode,
and the Indoor Unit’s OPERATION Indicator
Lamp and TIMER Indicator Lamp will begin
to fl ash simultaneously.
● To stop the test operation mode, press the
START/STOP button to stop the air condi-
tioner.
W RESET button
X Remote Control Unit Display (Fig. 7)
Y Transmit Indicator
Z Temperature SET Display
[ Fan Speed Display
\ Operating Mode Display
] SWING Display
` SLEEP Display
a T imer Mode Display
b Clock Display
● Refer to the folded out page on the cover.
En-3
PREPARATION
Turn on the Power
Connect the Power Supply Plug (Fig. 1 D) to an electri-
1
cal outlet; in the case of a direct line connection, turn
on the circuit breaker.
Load Batteries (Size AAA R03/LR03 × 2) *
Press and slide the battery compartment lid on the
1
reverse side to open it.
Slide in the direction of the arrow while pressing the mark.
* Batteries are not included with this product.
Insert batteries.
2
Be sure to align the battery polarities () correctly.
Close the battery compartment lid.
3
Set the Current time
Press the CLOCK ADJUST button (Fig. 6 U).
1
Use the tip of a ball-point pen or other small object to press the button.
CAUTION!
● Take care to prevent infants from accidentally swallowing batteries.
● When not using the Remote Control Unit for
an extended period, remove the batteries to
avoid possible leakage and damage to the
unit.
● If leaking battery fl uid comes in contact
with your skin, eyes, or mouth, immediately
wash with copious amounts of water, and
consult your physician.
● Dead batteries should be removed immediately and disposed of properly, either
in a battery collection receptacle or to the
appropriate authority.
● Do not attem pt to recharge dry batteries.
Never mix new and used batteries, or batteries of different types.
Batteries should last about one year under
normal use. If the Remote Control Unit’s
operating range becomes appreciably
reduced, replace the batteries and press
the RESET button with the tip of a ballpoint
pen or other small object.
Use the TIMER SET ( / ) buttons (Fig. 6 T) to
2
adjust the clock to the current time.
button: Press to advance the time.
(Each time the buttons are pressed, the time will be advanced/reversed in one-
button: Press to reverse the time.
minute increments; hold the buttons depressed to change the time quickly in
ten-minute increments.)
Press the CLOCK ADJUST button (Fig. 6 U) again.
3
This completes the time setting and starts the clock.
To Use the Remote Control Unit
● The Remote Control Unit must be pointed at signal receiver (Fig. 3 4) to operate cor-
rectly.
● Operating Range: About 7 meters.
● When a signal is properly received by the air conditioner, a beeping sound will be
heard.
● If no beep is heard, press the Remote Control Unit button again.
Remote Control Unit Holder
Insert
Press in
Screws
Slide up
Pull out
1 Mount the Holder. 2 Set the Remote Control
Unit.
3 To remove the Remote Con-
trol Unit (when use at hand).
En-4
Loading...
+ 12 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.