Seasonal Energy Efciency Ratio (SEER)26.022.720.3
Heating Seasonal Performance Factor (HSPF)12.611.611.2
MEASUREMENT CONDITIONS
ANSI/ASHRAE STANDARD 37-1988
2-Fan & Wide airow
z
Low outdoor air temperature correspondence
z
Corresponds to heating operation at -5 °F(-21°C) outdoor air temperature
Heating
-5 to 75 °F
(-21 to 24°C)
Powerful heating
z
Heating capacity was improved at low outdoor temperature. This new model can operate even at
-5°F (-21°C) low outdoor temperature.
Powerful operation
z
Continuous operation by maximum air ow and maximum compressor speed after a certain
period of time allows the temperature to reach the setting temp. quickly.
Air ow mode can be set in 4 steps and more detailed air ow setting is possible.
MIN. HEAT Operation
z
The room temperature can be set to go no lower than 50°F (10°C),
thus ensuring that the room does not get too cold when not occupied
Caution)
When the room temperature is higher than 50°F (10°C), “ •MIN. HEAT” operation does not start. Operation star ts and maintains the room
temperature at 50°F (10°C) when the temperature drops below 50°F (10°C).
•MIN. HEAT” operation stops, the room set temperature quickly returns to the preset temperature.
When “
Economy operation
z
Limits the maximum operation current, and the power consumption is cut down and the maximum
load is suppressed.
*Only available with Wireless RC.
- (01 - 02) -
Air conditioner lter feature
z
FLOOR TYPE
AGU9-15RLF
Apple-catechin lter Long-life ion deodorization lter
FLOOR TYPE
AGU9-15RLF
- (01 - 03) -
WIRELESS REMOTE CONTROLLER2.
60min.
2°F (1°C)
4°F (2°C)
Timer setting
30min.
60min.
90min.
8°F
(4°C)
Timer setting
6°F
(3°C)
4°F
(2°C)
2°F
(1°C)
ABCD
AB
C
D
Mixed-up
I.U. I.U. I.U. I.U.
I.U. I.U. I.U. I.U.
After code change
REG1U
FEATURES
FLOOR TYPE
AGU9-15RLF
Simple function setting
z
4 mode timer setup available (ON / OFF / PROGRAM / SLEEP).
Easy operation.
Easy to change custom code (max. 4 custom codes) by button operation.
FLOOR TYPE
AGU9-15RLF
Setting of the air conditioner selection function is performed by remote controller.
Built-in timers
z
Select from four different timer programs (On / Off / Program / Sleep).
Program timer
z
The program timer operates the on and off timer once within a 24-hour period.
Sleep timer
z
The sleep timer function automatically corrects the temperature thermostat setting according to
the timer setting to prevent excessive cooling and heating while sleeping.
Cooling operation/dry operation
When the sleep timer is set, the set temperature
automatically rises 2°F (1°C) every hour. The set
temperature can rise up to a maximum of 4°F (2°C).
Simple function setting
z
Heating operation
When the sleep timer is set, the set temperature
automatically drops 2°F (1°C) every 30 minutes. The
set temperature can drop to a maximum of 8°F (4°C).
Setting of the air conditioner selection function is performed by remote controller.
Switching remote controller custom code
z
Code selector switch eliminates unit
•
being wrongly switched.
(Up to 4 custom codes can be set.)
*I.U.=Indoor unit
To change the temperature unit
z
Easy to change the temperature unit (
°F ↔ °C) by button operation.
- (01 - 04) -
FUNCTIONS
REG1U
REG1U
Signal
FLOOR TYPE
AGU9-15RLF
transmitter
FLOOR TYPE
AGU9-15RLF
MIN. HEAT
button
TEMP.
button
POWERFUL
button
Start/Stop
button
ECONOMY button
TIMER ON button
TIMER OFF button
TIMER SELECT button
TIMER SLEEP button
TIMER CANCEL button
MODE button
CLOCK ADJUST button
FAN button
SWING button
SET button
RESET button
°C / °F switching button
Display panel
Mode indicator
Temperature indicator
Send indicator
To facilitate explanation, the accompanying illustration has been drawn to show all possible indicators; in actual operation,
however, the display will only show those indicators appropriate to the current operation.
SPECIFIC ATION
DIMENSIONS [H × W × D]: in. (mm)8-1/16 (205) × 2-3/8 (61) × 11/16 (17)
WEIGHT oz. (g)4.3 (122)
ACCESSORYHolder
Transmit indicator
Fan Speed indicator
Swing indicator
Clock & Timer
indicator
NOTE: Some button operations may
not be available for all units
or systems.
For details, refer to the
operation manual.
- (01 - 05) -
SPECIFICA TIONS3.
Type
FLOOR TYPE
AGU9-15RLF
Model na meAGU9RLFAGU12RLFAGU15RLF
Power sour ce208 / 230 V ~ 60Hz
Availabl e boltag e range187 - 253V ~ 60 Hz
Cooling
Capacity
Heating
Input pow er
Current
EERCooling
COPHeating
SEERCoolingBtu/hW26.022.720.3
HSPFHeatingBtu/hW12.611.611.2
Power fac tor
Moistu re removalpints/ h (l/h)2.7 (1.3)3.8 (1.8)4.4 (2.1)
Maximum operating current *1
Fan
Sound pr essure lev el
Heat excha nger ty pe
Enclosure
Dimensions
(H × W × D)
Weight
Connec tion pip e
Operat ion rang e
Remote co ntroll er typeWireless
Drain ho se
Cooling
Heating
Cooling
Heating4.16.77.0
Air ow rate
Type × Q'tyCross o w fan × 2
Motor ou tputW16 × 2
Net
Gross
Net
Gross37 (17)
Size
MethodFlare
MaterialPP + LLDPE
Sizein.( mm)Ø 9/16(Ø13.8) (I. D.), Ø5/8 to Ø11/16(Ø15.8 to Ø16.7) (O.D.)
Rated
Min. - Ma x.
Rated
Min. - Ma x.
Rated
Min. - Ma x.0.20 - 2.050.20 - 2.050.18 - 2.16
Rated0.881.441.58
Min. - Ma x.0.20 - 2.620.20 - 2.620.18 - 3.30
RatedA
Cooling
Heating939398
Cooling
Heating
Cooling
Heating
Cooling
Heating
Dimensions
(H × W × D)
Fin pitchFPI21
Rows × Stag es2 × 18
Pipe typ eCopper
Note :
Specications are based on the following conditions.
Cooling : Indoor temperature of 80°F (26.67°C) DB / 67°F (19.44°C) WB, and outdoor temperature of 95°F (35°C) DB / 75°F (23.9°C) WB.
Heating : Indoor temperature of 70°F (21.11°C) DB / 59°F (15°C) WB, and outdoor temperature of 47°F (8.33°C) DB / 43°F (6.11°C) WB.
Pipe length : 24ft.(7.5m), Height difference:0 m. (Outdoor unit-Indoor unit)
The protective function might work when using it outside the operation range.
*1: The maxim um curre nt is the ma ximum valu e when the o perated w ithin th e operat ion rang e.