Europe Energy Efficiency Classification A achieved
Up and down twin fan operation
Up to every corner of the room especially around the feet is heated evenly
by two-direction up and down discharge.
Flexible & easy installation
Piping space is wide and connection work is easy.
CoolingHeating
Fan motor
Front view
Space is wide and
piping work is easy
Large piping
bend R
Beneath standard windowStandard concave portion
Wall
Half concealed (Optional parts necessary)
(unit:mm)
600
740
200
700
(unit:mm)
Min.
700
Min.
590
Min.940
)mm:tinu()mm:tinu(
Max. 150
Min. 730
Max.
80
Choice of 6-direction drain &
piping connection
Back view
Drain hose
Piping
1
6
52
3
4
Page 3
- (01 - 02) -
FLOOR TYPE
FLOOR TYPE
AGF09-14LA
AGF09-14LA
ALL DC
Super quiet operation
Air flow mode can be set in 4 steps and more detailed air flow setting is possible.
Inner drying operation
This model is equipped with an inner drying function. After the power is turned off, the dry operation
starts inside the air conditioner. This prevents the growth of mold and bacteria inside the air conditioner.
Air conditioner filter feature
Apple-catechin filter
Long-life ion deodorization filter
DC Fan motor
b
a
c
a
V-PAM control
b
DC rotary compressor
c
a
DC fan motor
Economy mode
Limits the maximum operation current, and performs operation with the power consumption suppressed.
10°C heating operation
Operates in the 10°C heating mode so that the room does not become too cold even
when you are absent during the winter, etc.
Low ambient outdoor temperature design
Low ambient outdoor temperature design
-10 to 43˚C
-15 to 24˚C
Cooling
Heating
Page 4
- (01 - 03) -
FLOOR TYPE
AGF09-14LA
FLOOR TYPE
AGF09-14LA
FEATURES
Four kinds of timer setup (ON / OFF / PROGRAM / SLEEP) are possible.
Four kinds of timers. Easy operation.
Select from four different timer programs (On/Off/Program/Sleep).
Built-in timers
The program timer operates the ON and OFF timer once within a 24 hour period.
Program timer
The sleep timer function automatically corrects the temperature thermostat setting according to the
time setting to prevent excessive cooling and heating while sleeping.
Sleep timer
2-1. WIRELESS REMOTE CONTROLLER
2.
REMOTE CONTROLLER
Cooling operation/dry operation
60min.
1 °C
2 °C
When the sleep timer is set, the set temperature
automatically rises 1 °C every hour. The set
temperature can rise up to a maximum of 2 °C.
Heating operation
When the sleep timer is set, the set temperature
automatically drops 1 °C every 30 minutes. The
set temperature can drop to a maximum of 4 °C.
1 °C
30min.
60min.
90min.
2 °C
3 °C
4 °C
Timer setting
Timer setting
ABCD
AB
C
D
Mixed-up
I.U. I.U. I.U. I.U.
I.U. I.U. I.U. I.U.
After code change
Switching remote controller signal code
Code selector switch eliminates unit
•
being wrongly switched.
(Up to 4 codes can be set.)
*I.U.=Indoor unit
Page 5
- (01 - 04) -
FLOOR TYPE
AGF09-14LA
FLOOR TYPE
AGF09-14LA
Display panel
FUNCTIONS
SPECIFICATION
SIZE (H x W x D mm)176 x 56 x 18
WEIGHT ( g )110
ACCESSORYHolder
12
10
11
9
6
13
14
8
15
7
1
5
4
3
2
16
17
20
21
25
26
18
24
23
27
22
19
SLEEP button
MODE button
10°C HEAT button
SET TEMP. button (
/)
COIL DRY button
Signal Transmitter
TIMER MODE button
TIMER SET (
/ ) button
FAN CONTROL button
ECONOMY button
START/STOP button
SET button
SWING button
RESET button
TEST RUN button
This button is used when installing the
conditioner, and should not be used under normal conditions, as it will cause the
air conditioner’s thermostat function to operate incorrectly.
If this button is pressed during normal operation, the unit will switch to test operation mode, and the Indoor Unit’s OPERATION Indicator Lamp and TIMER Indicator
Lamp will begin to flash simultaneously.
To stop the test operation mode, press the
START/STOP button to stop the air conditioner.
CLOCK ADJUST button
Remote Control Unit Display
Transmit Indicator
Clock Display
ECONOMY Display
Operating Mode Display
Timer Mode Display
Fan Speed Display
Temperature SET Display
COIL DRY Display
SLEEP Display
SWING Display
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
18
17
16
19
20
21
22
23
24
25
26
27
Page 6
- (01 - 05) -
FLOOR TYPE
AGF09-14LA
FLOOR TYPE
AGF09-14LA
3. SPECIFICATIONS
AGF09LACAGF12LACAGF14LAC
CoolingAAA
HeatingAAA
kW2.603.504.20
BTU/h8,90011,90014,300
kW0.9 - 3.50.9 - 4.00.9 - 5.0
BTU/h3,100 - 11,9003,100 - 13,6003,100 - 17,100
kW3.504.505.20
BTU/h11,90015,40017,700
kW0.9 - 5.50.9 - 6.60.9 - 8.0
BTU/h3,100 - 18,8003,100 - 22,5003,100 - 27,300
0.530.941.14
0.25 - 1.350.25 - 1.400.25 - 1.90
0.791.191.44
0.25 - 2.100.25 - 2.150.25 - 2.95
2.64.45.2
7.07.09.0
3.85.56.4
1010.013.5
4.913.723.68
4.433.783.61
kW2.332.663.15
909396
909498
l/h (pints/h)1.3 (2.7)
1.8 (3.8)2.1 (4.4)
High
570570650
Med
460460520
Low
360360400
Quiet
270270270
High
600600650
Med
480480520
Low
370370390
Quiet
270270270
W424242
High
404044
Med
353538
Low
292931
Quiet
222222
High
404043
Med
353537
Low
292929
Quiet
222222
12.70 ( 1/2 in.)
°C
%RH
°C
mm
Note :
Specifications are based on the following conditions.
Cooling : Indoor temperature of 27°CDB/19°CWB. and outdoor temperature of 35°CDB/24°CW B.
Heating : Indoor temperature of 20°CDB/15°CWB. and outdoor temperature of 7°CDB/6°CWB.
Pipe length : 5 m, Height difference : 0 m. (Outdoor unit - Indoor unit)
The maximum current is the maximum value when operated within the operation range (temperature).
AFR : Air Flow Rate (m3/min)
TC : Total Capacity (kW)
SHC : Sensible Heat Capacity (kW)
PI :PowerInput(kW)
PI
Page 10
- (01 - 09) -
FLOOR TYPE
AGF09-14LA
FLOOR TYPE
AGF09-14LA
6-2. HEATING CAPACITY
MODEL : AGF09LA
MODEL : AGF12LA
MODEL : AGF14LA
TCPITCPITCPITCPITCPI
3.531.443.451.473.371.503.281.533.201.56
3.671.543.581.573.501.603.411.633.321.67
4.181.614.081.643.981.683.881.713.781.74
4.841.724.721.754.611.794.491.824.381.86
5.351.725.231.765.101.804.971.834.841.87
5.461.385.331.415.201.445.071.474.941.50
5.141.395.021.424.891.454.771.484.651.51
5.421.165.291.195.161.215.031.244.901.26
AFR : Air Flow Rate (m3/min)
TC ::Total Capacity (kW)
PI
:
PowerInput(kW)
AFR
10.8
Indoor temperature
°CDB16182022
24
O
utdoor
tempera
t
ure
°CDB
°CWB
-15
-16
-10
-11
-5
-7
0
-2
5
3
7
6
10
8
15
10
TCPITCPITCPITCPITCPI
3.040.962.970.982.891.002.821.022.751.04
3.341.013.261.043.181.063.101.083.021.10
3.781.063.691.093.601.113.511.133.421.15
4.401.144.301.164.201.184.091.213.991.23
4.891.214.771.244.661.264.541.294.421.31
4.721.144.611.174.501.194.391.214.271.24
5.431.165.301.185.171.205.041.234.911.25
5.431.095.301.115.171.145.041.164.911.18
AFR
10.0
Indoor temperature
°CDB16182022
24
Outdoor temperature
°CDB
°CWB
-15
-16
-10
-11
-5
-7
0
-2
5
3
7
6
10
8
15
10
TCPITCPITCPITCPITCPI
2.360.642.310.652.250.662.190.682.140.69
2.600.672.540.692.480.702.410.722.350.73
2.940.712.870.722.800.742.730.752.660.77
3.430.753.340.773.260.793.180.803.100.82
3.800.803.710.823.620.843.530.853.440.87
3.670.763.590.773.500.793.410.813.320.82
4.220.774.120.784.020.803.920.823.820.83
4.220.724.120.744.020.753.920.773.820.79
AFR
10.0
Indoor temperature
°CDB16182022
24
Outdoor temperature
°CDB
°CWB
-15
-16
-10
-11
-5
-7
0
-2
5
3
7
6
10
8
15
10
Page 11
- (01 - 10) -
FLOOR TYPE
AGF09-14LA
FLOOR TYPE
AGF09-14LA
7. FAN PERFORMANCE
7-1. AIR VELOCITY DISTRIBUTION
MODEL : AGF09LA, AGF12LA, AGF14LA
Note :
Fan speed : H i
Operation : FAN
Voltage : 230V
Fan select : UPPER&LOWER
: UPPER FAN
: LOWER FAN
SIDE VIEW
FLOW CONTROL PANEL : Horiz.
LOUVER :Center
0
1
2
3
(m)
(m)
1.0
0.5
Unit: m/s
1234
SIDE VIEW
FLOW CONTROL PANEL : Vert
LOUVER :Center
Unit: m/s
0
1
2
3
(m)
1.0
0.5
1234
(m)
TOP VIEW
FLOW CONTROL PANEL : Horiz.
LOUVER :Right & Left
TOP VIEW
FLOW CONTROL PANEL : Horiz.
LOUVER :Center
Unit: m/s
2
1
0
1
2
(m)
(m)
0.5
1234
UPPER
LOWER
1.0
Unit: m/s
2
1
0
1
2
(m)
(m)
0.5
1234
1.0
0.5
1.0
Page 12
- (01 - 11) -
FLOOR TYPE
AGF09-14LA
FLOOR TYPE
AGF09-14LA
MODEL : AGF09LA, AGF12LA
COOLING
7-2. AIR FLOW
HEATING
570
m3/h
158l/s
335CFM
460
m3/h
128l/s
271CFM
360
m3/h
100l/s
212CFM
270
m3/h
75l/s
159CFM
1190/1000
1000/850
820/690
660/560
HIGH
MED
LOW
QUIET
Fan speed
Number of rotations
[r.p.m]
(UPPER/LOWER)
Air flow
600
m3/h
167l/s
353CFM
480
m3/h
133l/s
282CFM
370
m3/h
103l/s
218CFM
270
m3/h
75l/s
159CFM
QUIET
660/560
840/700
1040/880
HIGH
1240/1040
MED
LOW
Fan speed
Number of rotations
[r.p.m]
(UPPER/LOWER)
Air flow
Page 13
- (01 - 12) -
FLOOR TYPE
AGF09-14LA
FLOOR TYPE
AGF09-14LA
MODEL : AGF14LA
COOLING
HEATING
650
m3/h
181l/s
383CFM
520
m3/h
144l/s
306CFM
400
m3/h
111l/s
235CFM
270
m3/h
75l/s
159CFM
LOW
QUIET
660/560
890/750
HIGH
1330/1120
1100/930
MED
Fan speed
Number of rotations
[r.p.m]
(UPPER/LOWER)
Air flow
650
m3/h
181l/s
383CFM
520
m3/h
144l/s
306CFM
390
m3/h
108l/s
230CFM
270
m3/h
75l/s
159CFM
LOW
QUIET
860/730
660/560
HIGH
1330/1120
1100/930
MED
Fan speed
Number of rotations
[r.p.m]
(UPPER/LOWER)
Air flow
Page 14
- (01 - 13) -
FLOOR TYPE
AGF09-14LA
FLOOR TYPE
AGF09-14LA
8-1. NOISE LEVEL CURVE
8. OPERATION NOISE
COOLING
Octave band sound pressure level, dB:(0dB=0.0002µbar)
Octave band center frequency,Hz
0
10
20
30
40
50
60
70
80
631252505001,0002,0004,0008,000
COOLING
Octave band sound pressure level, dB:(0dB=0.0002µbar)
Octave band center frequency,Hz
0
10
20
30
40
50
60
70
80
631252505001,0002,0004,0008,000
HEATING
MODEL : AGF09LA
MODEL : AGF12LA
High
Quiet
High
Quiet
NC-20
NC-40
NC-50
NC-60
NC-30
NC-15
NC-25
NC-35
NC-45
NC-55
NC-65
Octave band sound pressure level, dB:(0dB=0.0002µbar)
0
10
20
30
40
50
60
70
80
Octave band center frequency,Hz
631252505001,0002,0004,0008,000
High
Quiet
NC-20
NC-40
NC-50
NC-60
NC-30
NC-15
NC-25
NC-35
NC-45
NC-55
NC-65
HEATING
Octave band sound pressure level, dB:(0dB=0.0002µbar)
Octave band center frequency,Hz
0
10
20
30
40
50
60
70
80
631252505001,0002,0004,0008,000
High
Quiet
NC-20
NC-40
NC-50
NC-60
NC-30
NC-15
NC-25
NC-35
NC-45
NC-55
NC-65
NC-20
NC-40
NC-50
NC-60
NC-30
NC-15
NC-25
NC-35
NC-45
NC-55
NC-65
Page 15
- (01 - 14) -
FLOOR TYPE
AGF09-14LA
FLOOR TYPE
AGF09-14LA
COOLING
MODEL : AGF14LA
Octave band sound pressure level, dB:(0dB=0.0002µbar)
Octave band center frequency,Hz
0
10
20
30
40
50
60
70
80
631252505001,0002,0004,0008,000
High
Quiet
NC-20
NC-40
NC-50
NC-60
NC-30
NC-15
NC-25
NC-35
NC-45
NC-55
NC-65
Octave band sound pressure level, dB:(0dB=0.0002µbar)
0
10
20
30
40
50
60
70
80
Octave band center frequency,Hz
631252505001,0002,0004,0008,000
High
Quiet
NC-20
NC-40
NC-50
NC-60
NC-30
NC-15
NC-25
NC-35
NC-45
NC-55
NC-65
HEATING
Page 16
8-2.
SOUND LEVEL CHECK POINT
MicrophoneMicrophone
●●Air Flow
1m
Air Flow
1m
- (01 - 15) -
FLOOR TYPE
AGF09-14LA
FLOOR TYPE
AGF09-14LA
Page 17
- (01 - 16) -
FLOOR TYPE
AGF09-14LA
FLOOR TYPE
AGF09-14LA
9. ELECTRIC CHARACTERISTICS
*1) Wiring Spec.
Selected Sample
(Selected based on Japan Electrotechnical Standard and Codes Committee E0005)
AGF09LAAGF12LAAGF14LA
VoltageV
FrequencyHz
A0.60.60.6
Circuit breakerA0.70.70.7
Connection Cable
mm
2
1.5 - 2.51.5 - 2.51.5 - 2.5
Limited wiring lengthm212121
Model Name
Max Operating Current
*1)Wiring Spec.
Power Supply
230
50
Page 18
10. SAFETY DEVICES
AGF09LAAGF12LAAGF14LA
Circuit protectionCurrent fuse (PCB)
Terminal protectionCurrent fuse
Fan motor protectionThermal protection program
100
+15
-10
°C OFF
95
+5
-10
°C ON
Protection form
3.15A 250V
Model
3A 250V
- (01 - 17) -
FLOOR TYPE
AGF09-14LA
FLOOR TYPE
AGF09-14LA
Page 19
11.
Function number
Setting value
FUNCTION SETTING
F09-14LA
FLOOR TYPE
AG
INDOOR UNIT (Setting by remote controller)11 -1.
• The function settings of the control of the indoor unit can be changed by this procedure according
F09-14LA
FLOOR TYPE
AG
to the installation conditions. Incorrect settings can cause the indoor unit malfunction.
• After the power is turned on, perform the “FUNCTION SETTING” according to the installation
conditions using the remote controller.
• The settings may be selected between the following two: Function Number or Setting Value.
•Settings will not be changed if invalid numbers or setting values are selected.
PREPARATION
•Turn on the power.
* By turning on the power indoor units, so make sure the piping air-tight test and vacuuming have
been conducted before turning on the power.
* Also check again to make sure no wiring mistakes were made before turning on the power.
FUNCTION SETTING METHOD (for Wireless remote controller)
Entering the Function Setting Mode
While pressing the FAN button and SET TEMP. (
•
setting mode.
STEP 1
Setting the Remote controller Signal Code
Use the following steps to select the signal code of the remote controller. (Note
that the air conditioner cannot receive a signal code if the air conditioner has not
been set for the signal code.) The signal codes that are set through this process are
applicable only to the signals in the FUNCTION SETTING. For details on how to set
the signal codes through the normal process, refer to SELECTING THE REMOTE
CONTROLLER SIGNAL CODE.
Press the SET TEMP. (1.
→
→ Match the code on the display to the air conditioner signal code. (initially
set to
(If the signal code does not need to be selected, press the MODE button and
proceed to STEP 2.)
Press the TIMER MODE button and check that the indoor unit can receive signals 2.
at the displayed signal code.
Press the MODE button to accept the signal code, and proceed to STEP 2.3.
)
) ( ) button to change the signal code between →
) simultaneously, press the RESET button to enter the function
The air conditioner signal code is set to A prior to shipment.
The remote controller resets to signal code A when the batteries in the remote controller are replaced. If you use a
signal code other than signal code A, reset the signal code after replacing the batteries.
If you do not know the air conditioner signal code setting, try each of the signal codes (
find the code which operates the air conditioner.
STEP 2
Selecting the Function Number and Setting Value
Press the SET TEMP. (1.
number.
(Press the MODE button to switch between the left and right
digits.)
Press the FAN button to proceed to setting the value.2.
Press the FAN button again to return to the function number
selection.)
Press the SET TEMP. (3.
value.
(Press the MODE button to switch between the left and right
digits.)
Press the TIMER MODE button, and START/STOP button, 4.
in the order listed to confirm the settings.
Press the RESET button to cancel the function setting 5.
mode.
After completing the FUNCTION SETTING, be sure to turn 6.
off the power and turn it on again.
) ( ) buttons to select the function
) ( ) buttons to select the setting
→ → → ) until you
CAUTION
After turning off the power, wait 10 seconds or more before turning on it again.
The FUNCTION SETTING doesn’t become effective if it doesn’t do so.
- (01 - 18) -
Page 20
FUNCTION DETAILS
(... Factory setting)
Setting descriptionFunction numberSetting value
Standard
31
00
Lower control01
Slightly warmer control02
Warmer control03
3) Embedding the indoor unit in a wall
(... Factory setting)
Setting descriptionFunction numberSetting value
Standard
In a wall
23
00
01
02
F09-14LA
FLOOR TYPE
AG
Functions Floor
1)
Cooler room temperature correction
F09-14LA
FLOOR TYPE
AG
Heater room temperature correction
2)
3)
Embedding the indoor unit in a wail
4) Auto restart
Indoor room temperature sensor
5)
switching function
6) Remote controller signal code
1) Cooler room temperature correction
Depending on the installed environment, the room temperature sensor may require a
correction.
The settings may be selected as shown in the table below.
(... Factory setting)
Setting descriptionFunction numberSetting value
Standard
Slightly lower control01
Lower control02
Warmer control03
30
00
2) Heater room temperature correction
Depending on the installed environment, the room temperature sensor may require a
correction.
The settings may be changed as shown in the table below.
-
- (01 - 19) -
Page 21
F09-14LA
FLOOR TYPE
AG
4) Auto restart
F09-14LA
FLOOR TYPE
AG
Enable or disable automatic system restart after a power outage.
(... Factory setting)
Setting descriptionFunction numberSetting value
Yes
No01
40
00
* Auto restart is an emergency function such as for power failure etc.
Do not start and stop the indoor unit by this function in normal operation.
Be sure to operate by the control unit, or external input device.
5) Indoor room temperature sensor switching function
(Only for Wired remote controller)
The following settings are needed when use the control by Wired remote controller
temperature sensor.
(... Factory setting)
Setting descriptionFunction numberSetting value
No
Yes01
42
00
* If setting value is “00” :
Room temperature is controlled by the indoor unit temperature sensor.
* If setting value is “01” :
Room temperature is controlled by either indoor unit temperature sensor or remote controller
unit sensor.
6) Remote controller signal code
Change the indoor unit Signal Code, depending on the remote controllers.
(... Factory setting)
Setting descriptionFunction numberSetting value
A
B01
C02
D03
44
00
- (01 - 20) -
Page 22
F09-14LA
FLOOR TYPE
AG
REMOTE CONTROLLER SIGNAL CODE SETTING
Use the following steps to select the signal code of the remote controller.
(Note that the air conditioner cannot receive a signal code if the air conditioner has
not been set for the signal code.)
Press the START/STOP button until only the clock is displayed on the remote 1.
controller display.
Press the MODE button for at least five seconds to display the current signal code 2.
(initially set to
Press the SET TEMP. (3.
→
→ .
Match the code on the display to the air conditioner signal code.
Press the MODE button again to return to the clock display. The signal code will 4.
be changed.
If no buttons are pressed within 30 seconds after the signal code is displayed, the system returns to the original
clock display. In this case, start again from step 1.
The air conditioner signal code is set to A prior to shipment.
Contact your retailer to change the signal code.
The remote controller resets to signal code A when the batteries in the remote controller are replaced. If you use
a signal code other than signal code A, reset the signal code after replacing the batteries. If you do not know the
air conditioner signal code setting, try each of the signal codes (
operates the air conditioner.
).
) ( ) button to change the signal code between →
→ → → ) until you find the code which
F09-14LA
FLOOR TYPE
AG
- (01 - 21) -
Page 23
- (01 - 22) -
FLOOR TYPE
AGF09-14LA
FLOOR TYPE
AGF09-14LA
12. OPTIONAL PARTS
ExteriorSummary
Parts name
Wired remote
controller
Apple-catechin
filter
Ion deodorisation
filter
Half concealed
External
connect kit
kit
Model No.
UTB-UD
UTR-FC03-2
UTR-FC03-3
UTR-STA
UTY-XWZX
Unit control is performed by
wired remote controller.
Fine dust, invisible mold spores,
and harmful microorganisms
are absorbed onto the filter by
static electricity, and further
growth is inhibited and
deactivated by the polyphenol
ingredient extracted from
apples.
The filter deodorizes by
powerfully decomposing
absorbed odors using the
oxidizing and reducing effects
of ions generated by the ultra
fine-particle ceramic.
Use to connect with various
peripheral devices and air
conditioner PC board.
Using the Unit installing of half
concealed.
SUMOTUWETHFR
SA
AM
PM
3 6 9
12 15 18 21
Page 24
- (01 - 23) -
FLOOR TYPE
AGF09-14LA
FLOOR TYPE
AGF09-14LA
12-1. WIRED REMOTE CONTROLLER
FEATURES
Simple function setting
Setting of the air conditioner selection function is performed by remote controller.
High performance and compact size
Various timer setup (ON / OFF / WEEKLY) are possible.
Equipped with weekly timer as standard function.
(2 times Start / Stop per day for a week)
When setting up a timer, operation mode and a temperature
setup can be changed.
When a failure occurs,the error code is displayed.
Error indication.
Economy operation are possible.
Easy installation with a slim shape with no bulge in the back.
Three functions are combined in
one unit.
Wired
remote
controller
Built-in timers
Possible to set ON/OFF time to operate twice each day
of the week.
SUMOTUWETH FR SA
7
Setup screen example
(Set to Wednesday: 8:00 to 20:00.)
3126 9
15 18 21
036912151821 Time
At "Weekly timer" + "Set back timer" setup
Easy-to-understand time bar display
SUMOTUWETH FR SA
7
3126 9
15 18 21
24°C
24°C28°C24°C
Weekly
timer
Setback
timer
Setback timerWeekly timer
Possible to set temperature for two time spans and
for each day of the week.
SUMOTUWETH FR SA
Screen
after setup
Setup screen example
(Set from Sunday to Saturday: 12:00 to 15:00, 28 °C.)
036912151821 Time
24°C
036912151821 Time
28°C
3126 9
15 18 21
28°C
Easy-to-understand operationSimple installation
Components are compatible with standard
switch boxes. Flat back construction allows
equipment to be installed wherever it is
needed.
Timer
area
[
Variable timer control
]
The operation/display sections are zoned according to time and operation, enabling variable programming to match application.
Operation
area
European
switch box
JIS box
Page 25
- (01 - 24) -
FLOOR TYPE
AGF09-14LA
FLOOR TYPE
AGF09-14LA
FUNCTIONS
Display panel
10
11
1
START/STOP button
Pressed to start and stop operation.
2
Set temperature button
Selects the setting temperature.
3
Master control button
15
2
6
7
8
9
19
20
16
18
1
3
4
13
12
5
14
17
Selects the operating mode(AUTO, HEAT, FAN, COOL, DRY).
4
Fan control button
Selects the fan speed (AUTO, QUIET, LOW, MED, HIGH).
5
Economy button
Turns the economy efficient mode on and off.
6
Timer mode (CLOCK ADJUST) button
Selects the timer mode (OFF TIMER, ON TIMER, WEEKLY TIMER)
Set the current time.
7
Day (DAY OFF) button
Temporarily cancels of one day timer.
8
Set back button
Pressed to select the set back timer.
9
Set time button
Pressed to set time.
10
Delete button
The schedule of a weekly timer is deleted.
11
Set button
Sets the date, hour, minute and on-off time.
12
Vertical airflow direction and swing button
Push for two seconds to change the swing mode.
13
Horizontal airflow direction and swing button
Push for two seconds to change the swing mode.
DIMENSION
120
Front View
SPECIFICATION
21
[ Unit : mm ]
120
14
Filter button
15
Operation lamp
Lights during operation and when the timer is on.
16
Timer and clock display
17
17
Operation mode display
18
Fan speed display
19
Operation lock display
20
Temperature display
21
Function display
Defrost display
Thermo sensor display
Economy display
Vertical swing display
Horizontal sw
ing display
Filter display
SIZE(H x W x D mm)120 x 120 x 17
WEIGHT( g )160
CABLE LENGTH( m )
POWER( V )
10
12
Button number 13 and
can not be operated.
14
Page 26
- (01 - 25) -
FLOOR TYPE
AGF09-14LA
FLOOR TYPE
AGF09-14LA
12-2. EXTERNAL CONNECT KIT
Orange
External
input
External
output
1
3
Yellow
Indoor unitExternal device
( Field supply )
Print circuit
board
Orange
External
input
External
1
3
Yellow
Indoor unitExternal device
( Field supply )
Print circuit
board
This kit allows to operate the air conditioner, such as stopping and starting, using an external
device, and output the operation status of the air conditioner.
• Only operation and stop signals will be output.
Use the remote control to check the operation mode, temperature, and airflow.
Check the error information on the display area of the main unit.
• Operation mode, temperature, and airflow cannot be set by external input. Use the remote
controller to set.
• If the air-conditioner is activated by external input, it will operate in the settings before stop.
To change the settings, use the remote controller.
12-2-1. CONTROL INPUT SETTING
• You can control air conditioner ON / OFF operation by external input.
Signal specification
• No voltage ON/OFF continuous signal.
• Contact capacity : DC12V 10mA
External input signal
ON
OFF
Remote controller signal
OPERATION
Indoor unit status
Installation example
• For remote operation
• For external timer operation
ONONOFFOFF
STOP
Page 27
- (01 - 26) -
FLOOR TYPE
AGF09-14LA
FLOOR TYPE
AGF09-14LA
12-2-2. Operating output setting
• You can display air conditioner ON / OFF operation by external output.
Signal specification
• No voltage contact.
• Contact capacity : Max. DC24V 10mA to 1A or less
OPERATION
Indoor unit status
STOP
SHORT
External output signal
OPEN
Installation example
For operation display
Indoor unit
Print circuit
board
External
input
External
output
1
2
Blue
Purple
External device
( Field supply )
Ic
Vc
Page 28
R410A
D1D_AO006E/03
2009.03.04
2.
SINGLE TYPE :
AO V09LAC
AO V12LAC
AO V14LAC
OUTDOOR UNIT
Page 29
- (02 - 01) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
1. SPECIFICATIONS
AO V09LACAO V12LACAO V14LAC
A3.85.56.4
1,6801,6801,910
1,4901,6801,750
Propeller fan × 1Propeller fan × 1Propeller fan × 1
W56
474850
484950
504 × 850 × 36.4504 × 850 × 36.4546 × 876 × 36.4
1.401.401.30
2 × 242 × 242 × 26
CopperCopperCopper
Aluminium Aluminium Aluminium
Rotary × 1Rotary × 1Rotary × 1
W7507501,100
R410AR410AR410A
g1,0501,0501,150
ESTER OILESTER OILESTER OIL
SteelSteelSteel
Beige Beige Beige
540 × 790 × 290540 × 790 × 290578 × 790 × 300
648 × 910 × 380648 × 910 × 380648 × 910 × 380
36 (79)36 (79)40 (88)
40 (88)40 (88)44 (97)
12.70 ( 1/2 in.)
Note :
Specifications are based on the following conditions.
Cooling : Indoor temperature of 27°CDB/19 °CWB. and outdoor temperature of 35°CDB/24°CWB.
Heating : Indoor temperature of 20°CDB/15°CWB. and outdoor temperature of 7°CDB/6°CWB.
Pipe length : 5 m, Height difference : 0 m. (Outdoor unit - Indoor unit)
Material
Colour
Net
Gross
Motor output
Type
Charge
Type
Rows × Stages
Pipe type
Fin type
Type × Q'ty
Motor output
Cooling
Heating
Dimensions (H × W × D)
Type
Model name
Power source
Available voltage range
-15 to 24
Flare
20 (chargeless : 15)
15
-10 to 43
230V 50Hz
198 - 264V 50Hz
9.52 ( 3/8 in.)
6.35 ( 1/4 in.)
m
Connection pipe
Size
mm
Liquid
Gas
Method
Max. length
Max. height difference
Compressor
Refrigerant
Sound pressure level
Starting current
Cooling
Heating
Type × Q'ty
mm
mm
Weight
kg(lb.)
Dimensions
(H × W × D)
Refrigerant oil
Enclosure
Heat exchanger type
Fin pitch
Net
INVERTER HEAT PUMP
°C
Operation range
Fan
Airflow
rate
m3/h
dB(A)
Gross
Cooling
Heating
3333
Page 30
- (02 - 02) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
2. DIMENSIONS
MODEL : AO V09LA, AO V12LA
(Unit : mm)
INSTALLATION PLACE
347
578
48
10
320
508
540
20
300
125
60
790
540
790
56
290
353
17
MODEL : AO V14LA
100 mm or more
600 mm or more
100 mm or more
200 mm or more
250 mm or
more
50 mm or more
540125
Page 31
- (02 - 03) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
MODEL : AO V09LA, AO V12LA, AO V14LA
3. REFRIGERANT CIRCUIT
2-Way
valve
Strainer
Strainer
3-Way
valve
Muffler
4-Way valve
Expansion valve
Indoor unit
Heat exchanger
Outdoor unit
Heat exchanger
Compressor
Refrigerant direction
Heating
Cooling
Page 32
- (02 - 04) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
MODEL : AO V09LA, AO V12LA, AO V14LA
4. WIRING DIAGRAMS
WHITE
RED
YELLOW
YELLOW
BLACK
BLACK
BROWN
BROWN
BLACK
BLACK
RED
WHITE
BLACK
GREEN
BLACK
BLACK
BLACK
WHITE
BLACK
BLACK
WHITE
YELLOW
ORANGE
BLUE
BROWN
RED
BLUE
YELLOW
WHITE
BLACK
RED
BLACK
WHITE
RED
BLACK
WHITE
RED
1
2
3
4
5
6
1
2
3
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
1
2
3
1
2
3
4
1
2
3
4
1
2
3
1
2
3
221
1
1
2
3
CN71
CN70
W10
W11
W4
W2
W1
W3
CN30
CN40
CN800
W7
W8
W9
FUSE
250V
20A
FUSE
250V 15A
TERMINAL
TO INDOOR UNIT POWER SOURCE
L N32
1
4-WAY VALVE
EXPANSION VALVE
FAN MOTOR
COMPRESSOR
PIPE THERMISTOR
DISCHARGE PIPE THERMISTOR
OUTDOOR THERMISTOR
CM
FM
PMV
S ( S )
R ( R )
C ( T )
4WV
WHITE
RED
REACTOR
AO V09, 12L
AO V14L
Page 33
- (02 - 05) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
5. CAPACITY COMPENSATION RATE FOR PIPE LENGTH
AND HEIGHT DIFFERENCE
MODEL : AO V09LA, AO V12LA
Indoor unit
Height difference H
Connection pipe
H
Outdoor unit
Indoor unit
Connection pipe
H
Outdoor unit
Indoor unit is upper than outdoor unit.
1
Indoor unit is under than outdoor unit.
2
57.5101520
15---0.9150.905
10--0.9550.9220.912
7.5-0.9740.9590.9260.916
50.9920.9780.9630.9300.920
01.0000.9860.9710.9370.927
-51.0000.9860.9710.9370.927
-7.5-0.9860.9710.9370.927
-10--0.9710.9370.927
-15---0.9370.927
57.5101520
15---0.8630.846
10--0.9440.8630.846
7.5-0.9780.9440.8630.846
51.0000.9780.9440.8630.846
01.0000.9780.9440.8630.846
-50.9950.9730.9390.8580.842
-7.5-0.9710.9370.8560.840
-10--0.9340.8540.838
-15---0.7940.778
HEATING
COOLING
1
Indoor unit is upper
than outdoor unit.
2
Indoor unit is under
than outdoor unit
Height
difference H
(m)
Pipe length (m)
Pipe length (m)
Height
difference H
(m)
1
Indoor unit is upper
than outdoor unit.
2
Indoor unit is under
than outdoor unit
Page 34
- (02 - 06) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
MODEL : AO V14LA
Indoor unit
Height difference H
Connection pipe
H
Outdoor unit
Indoor unit
Connection pipe
H
Outdoor unit
Indoor unit is upper than outdoor unit.1Indoor unit is under than outdoor unit.2
57.5101520
15---0.9500.946
10--0.9760.9580.954
7.5-0.9840.9800.9620.958
50.9920.9880.9840.9660.962
01.0000.9960.9920.9740.969
-51.0000.9960.9920.9740.969
-7.5-0.9960.9920.9740.969
-10--0.9920.9740.969
-15---0.9740.969
57.5101520
15---0.8530.824
10--0.9430.8530.824
7.5-0.9820.9430.8530.824
51.0000.9820.9430.8530.824
01.0000.9820.9430.8530.824
-50.9950.9770.9380.8480.820
-7.5-0.9750.9360.8460.818
-10--0.9330.8440.816
-15---0.7850.758
Height
difference H
(m)
1
Indoor unit is upper
than outdoor unit.
2
Indoor unit is under
than outdoor unit
Pipe length (m)
Pipe length (m)
HEATING
COOLING
1
Indoor unit is upper
than outdoor unit.
2
Indoor unit is under
than outdoor unit
Height
difference H
(m)
Page 35
- (02 - 07) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
6. ADDITIONAL CHARGE CALCULATION
MODEL : AO V09LA, AO V12LA, AO V14LA
REFRIGERANT CHARGE
Refrigerant amountg
Pipe lengthm 1520
Additional chargeg0 (Chargeless)+100
MODEL
Refrigerant type
20g/m
AO V09LA
AO V12LA
AO V14LA
R410A
1,050
R410A
1,150
R410A
1,050
Page 36
- (02 - 08) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
MODEL : AO V09LA, AO V12LA, AO V14LA
COOLING
7. AIR FLOW
HEATING
MODEL
Number of rotationsr.p.m.760r.p.m.760r.p.m.820
m3/h
1680
m3/h
1680
m3/h
1910
l/s467l/s467l/s531
CFM989CFM989CFM1124
MODEL
Number of rotationsr.p.m.680r.p.m.760r.p.m.750
m3/h
1490
m3/h
1680
m3/h
1750
l/s414l/s467l/s486
CFM877CFM989CFM1030
Air flow
Air flow
AO V14LA
AO V14LA
AO V09LA
AO V09LA
AO V12LA
AO V12LA
Page 37
- (02 - 09) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
8-1. NOISE LEVEL CURVE
8. OPERATION NOISE
MODEL : AO V09LA
MODEL : AO V09LAMODEL : AO V12LA
COOLING
HEATING
MODEL : AO V12LA
Octave band sound pressure level, dB:(0dB=0.0002µbar)
Octave band center frequency,Hz
0
10
20
30
40
50
60
70
80
631252505001,0002,0004,0008,000
NC-20
NC-40
NC-50
NC-60
NC-30
NC-15
NC-25
NC-35
NC-45
NC-55
NC-65
Octave band sound pressure level, dB:(0dB=0.0002µbar)
0
10
20
30
40
50
60
70
80
Octave band center frequency,Hz
631252505001,0002,0004,0008,000
NC-20
NC-40
NC-50
NC-60
NC-30
NC-15
NC-25
NC-35
NC-45
NC-55
NC-65
Octave band sound pressure level, dB:(0dB=0.0002µbar)
Octave band center frequency,Hz
0
10
20
30
40
50
60
70
80
631252505001,0002,0004,0008,000
NC-20
NC-40
NC-50
NC-60
NC-30
NC-15
NC-25
NC-35
NC-45
NC-55
NC-65
Octave band sound pressure level, dB:(0dB=0.0002µbar)
Octave band center frequency,Hz
0
10
20
30
40
50
60
70
80
631252505001,0002,0004,0008,000
NC-20
NC-40
NC-50
NC-60
NC-30
NC-15
NC-25
NC-35
NC-45
NC-55
NC-65
Page 38
- (02 - 10) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
MODEL : AO V14LA
MODEL : AO V14LA
COOLING
HEATING
Octave band sound pressure level, dB:(0dB=0.0002µbar)
Octave band center frequency,Hz
0
10
20
30
40
50
60
70
80
631252505001,0002,0004,0008,000
NC-20
NC-40
NC-50
NC-60
NC-30
NC-15
NC-25
NC-35
NC-45
NC-55
NC-65
Octave band sound pressure level, dB:(0dB=0.0002µbar)
0
10
20
30
40
50
60
70
80
Octave band center frequency,Hz
631252505001,0002,0004,0008,000
NC-20
NC-40
NC-50
NC-60
NC-30
NC-15
NC-25
NC-35
NC-45
NC-55
NC-65
Page 39
- (02 - 11) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
8-2. SOUND LEVEL CHECK POINT
Page 40
- (02 - 12) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
9. ELECTRIC CHARACTERISTICS
AO V09LAAO V12LAAO V14LA
VoltageV
FrequencyHz
A10.010.013.5
A3.85.56.4
Main Fuse (Circuit breaker)
Current
A202020
Power Cable
mm
2
1.5 - 2.51.5 - 2.51.5 - 2.5
*2)Limited wiring lengthm151511
*1) Wiring Spec.
Selected Sample
(Selected based on Japan Electrotechnical Standard and Codes Committee E0005)
*2) Limited Wiring length :
This is the wiring length in case voltage descent is less than 2%.
When the wiring length becomes long, please select the wiring of a more larger diameter.
Model Name
Power Supply
*1) Wiring Spec.
230
50
Max Operating Current
Starting Current
Page 41
- (02 - 13) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
10. SAFETY DEVICES
Fan motor protectionThermal protection program
Compressor protection
Thermal protection program
(DISCHARGE TEMP.)
OFF : 100
+15
-10
°C
ON : 95
+15
-10
°C
OFF : 110°C
ON : After 7 minutes
20A 250V
5A 250V
15A 250V
3.15A 250V
15A 250V
3.15A 250V
OFF : 100
+15
-10
°C
ON : 95
+15
-10
°C
OFF : 110°C
ON : After 7 minutes
Protection form
20A 250V
5A 250V
AO V09LA
Model
AO V14LA
20A 250V
5A 250V
AO V12LA
15A 250V
3.15A 250V
Circuit protection
OFF : 110°C
ON : After 7 minutes
Current fuse
(NEAR THE TERMINAL)
Current fuse
(MAIN PRINTED CIRCUIT BOARD)
OFF : 100
+15
-10
°C
ON : 95
+15
-10
°C
Loading...
+ hidden pages