Fujitsu AG*F09LAC, AG*F14LAC, AG*F12LAC Instruction Manual

Page 1
R410A
D1D_AG003E/03
2011.04.20
1. FLOOR
TYPE :
AGF09LAC AGF12LAC AGF14LAC
INDOOR UNIT
Page 2
MODEL : AGF09LAC AGF12LAC AGF14LAC
FEATURES
1. FEATURE
Energy Efficiency Classification A
AOV09/12LA
AOV14LA
Europe Energy Efficiency Classification A achieved
Up and down twin fan operation
Up to every corner of the room especially around the feet is heated evenly by two-direction up and down discharge.
Flexible & easy installation
Piping space is wide and connection work is easy.
Cooling Heating
Fan motor
Front view
Space is wide and piping work is easy
Large piping bend R
Beneath standard window Standard concave portion
Wall
Half concealed (Optional parts necessary)
(unit:mm)
600
740
200
700
(unit:mm)
Min. 700
Min. 590
Min.940
)mm:tinu()mm:tinu(
Max. 150
Min. 730
Max. 80
Choice of 6-direction drain & piping connection
Back view
Drain hose Piping
1
6
52
3
4
Page 3
ALL DC
Super quiet operation
Air flow mode can be set in 4 steps and more detailed air flow setting is possible.
Inner drying operation
This model is equipped with an inner drying function. After the power is turned off, the dry operation starts inside the air conditioner. This prevents the growth of mold and bacteria inside the air conditioner.
Air conditioner filter feature
Apple-catechin filter
Long-life ion deodorization filter
DC Fan motor
b
a
c
a
V-PAM control
b
DC rotary compressor
c
a
DC fan motor
Economy mode
Limits the maximum operation current, and performs operation with the power consumption suppressed.
10°C heating operation
Operates in the 10°C heating mode so that the room does not become too cold even when you are absent during the winter, etc.
Low ambient outdoor temperature design
Low ambient outdoor temperature design
-10 to 43˚C
-15 to 24˚C
Cooling
Heating
Page 4
FEATURES
Four kinds of timer setup (ON / OFF / PROGRAM / SLEEP) are possible.
Four kinds of timers. Easy operation.
Select from four different timer programs (On/Off/Program/Sleep).
Built-in timers
The program timer operates the ON and OFF timer once within a 24 hour period.
Program timer
The sleep timer function automatically corrects the temperature thermostat setting according to the time setting to prevent excessive cooling and heating while sleeping.
Sleep timer
2-1. WIRELESS REMOTE CONTROLLER
2.
REMOTE CONTROLLER
Cooling operation/dry operation
60min.
1 °C
2 °C
When the sleep timer is set, the set temperature automatically rises 1 °C every hour. The set temperature can rise up to a maximum of 2 °C.
Heating operation
When the sleep timer is set, the set temperature automatically drops 1 °C every 30 minutes. The set temperature can drop to a maximum of 4 °C.
1 °C
30min.
60min.
90min.
2 °C
3 °C
4 °C
Timer setting
Timer setting
A B C D
A B
C
D
Mixed-up
I.U. I.U. I.U. I.U.
I.U. I.U. I.U. I.U.
After code change
Switching remote controller signal code
Code selector switch eliminates unit
• being wrongly switched. (Up to 4 codes can be set.)
*I.U.=Indoor unit
Page 5
Display panel
FUNCTIONS
SPECIFICATION
SIZE (H x W x D mm) 176 x 56 x 18
WEIGHT ( g ) 110
ACCESSORY Holder
12
10
11
9
6
13
14
8
15
7
1
5
4
3
2
16
17
20
21
25
26
18
24
23
27
22
19
SLEEP button
MODE button
10°C HEAT button
SET TEMP. button (
/ )
COIL DRY button
Signal Transmitter
TIMER MODE button
TIMER SET (
/ ) button
FAN CONTROL button
ECONOMY button
START/STOP button
SET button
SWING button
RESET button
TEST RUN button
This button is used when installing the conditioner, and should not be used un­der normal conditions, as it will cause the air conditioner’s thermostat function to op­erate incorrectly. If this button is pressed during normal op­eration, the unit will switch to test opera­tion mode, and the Indoor Unit’s OPERA­TION Indicator Lamp and TIMER Indicator Lamp will begin to flash simultaneously. To stop the test operation mode, press the START/STOP button to stop the air condi­tioner.
CLOCK ADJUST button
Remote Control Unit Display
Transmit Indicator
Clock Display
ECONOMY Display
Operating Mode Display
Timer Mode Display
Fan Speed Display
Temperature SET Display
COIL DRY Display
SLEEP Display
SWING Display
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
18
17
16
19
20
21
22
23
24
25
26
27
Page 6
- (01 - 05) -
FLOOR TYPE
AGF09-14LA
FLOOR TYPE
AGF09-14LA
3. SPECIFICATIONS
AGF09LAC AGF12LAC AGF14LAC
Cooling A A A
Heating A A A
kW 2.60 3.50 4.20
BTU/h 8,900 11,900 14,300
kW 0.9 - 3.5 0.9 - 4.0 0.9 - 5.0
BTU/h 3,100 - 11,900 3,100 - 13,600 3,100 - 17,100
kW 3.50 4.50 5.20
BTU/h 11,900 15,400 17,700
kW 0.9 - 5.5 0.9 - 6.6 0.9 - 8.0
BTU/h 3,100 - 18,800 3,100 - 22,500 3,100 - 27,300
0.53 0.94 1.14
0.25 - 1.35 0.25 - 1.40 0.25 - 1.90
0.79 1.19 1.44
0.25 - 2.10 0.25 - 2.15 0.25 - 2.95
2.6 4.4 5.2
7.0 7.0 9.0
3.8 5.5 6.4
10 10.0 13.5
4.91 3.72 3.68
4.43 3.78 3.61
kW 2.33 2.66 3.15
90 93 96
90 94 98
l/h (pints/h) 1.3 (2.7)
1.8 (3.8) 2.1 (4.4)
High
570 570 650
Med
460 460 520
Low
360 360 400
Quiet
270 270 270
High
600 600 650
Med
480 480 520
Low
370 370 390
Quiet
270 270 270
W 42 42 42
High
40 40 44
Med
35 35 38
Low
29 29 31
Quiet
22 22 22
High
40 40 43
Med
35 35 37
Low
29 29 29
Quiet
22 22 22
12.70 ( 1/2 in.)
°C
%RH
°C
mm
Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27°CDB/19°CWB. and outdoor temperature of 35°CDB/24°CW B. Heating : Indoor temperature of 20°CDB/15°CWB. and outdoor temperature of 7°CDB/6°CWB. Pipe length : 5 m, Height difference : 0 m. (Outdoor unit - Indoor unit) The maximum current is the maximum value when operated within the operation range (temperature).
Method
Cooling
Heating
Size
Net
Gross
Liquid
Gas
Material
Colour
Net
Gross
Type × Q'ty
Motor output
Dimensions (H × W × D)
Fin pitch
Model name
EER
COP
Moisture removal
Cross flow fan × 2
30 or less
Wireless
PP+LLDPE
700 × 820 × 310
14 (31)
17 (37)
6.35 ( 1/4 in.)
Outer diameter : 29 / Inner diameter : 13.6
9.52 ( 3/8 in.)
Flare
18 to 32
80 or less
230V 50Hz
198 - 264V 50Hz
White
600 × 740 × 200
378 × 550 × 26.6
1.2
2 × 18
Copper
Aluminium
Polystyrene
Cooling
Heating
Sound pressure level dB(A)
Type
mm
Rated
Min-Max
Rated
Min-Max
Rated
Min-Max
Power source
Available voltage range
Capacity
Cooling
Heating
European energy label
Input power
Cooling
kW
Heating
Rated
Min-Max
Current
Cooling
SENSIBLE CAPACITY
POWER FACTOR
Heating
%
Cooling
Heating
Cooling
Operation range
kg(lb.)
Heat exchanger type
Enclosure
mm
mm
Rows × Stages
Pipe type
Fin type
Remote controller type
Drain pipe
Material
FLOOR TYPE
INVERTER HEAT PUMP
Cooling (UPPER : LOWER)
Heating (UPPER : LOWER)
m3/h
A
Rated
kW/kW
Max
Rated
Max
Connection pipe
Size
Dimensions (H × W × D)
Weight
Cooling
Heating
Fan
Airflow rate
Page 7
4. DIMENSIONS
(Unit : mm)
INSTALLATION PLACE
MODEL : AGF09LA, AGF12LA, AGF14LA
200
600
740
Front view
Side view
10 cm or more
8 cm or more
8 cm or more
5 cm or more
15 cm or below from the floor
Page 8
5. WIRING DIAGRAMS
MODEL : AGF09LA, AGF12LA, AGF14LA
PIPE THERMISTOR
ROOM THERMISTOR
INDICATOR PCB ASSY
CN203
2
3
4
6
1
CN202
SWITCH PCB ASSY
5
2
3
CN201
4
9 8
7 6 5 4 3 2 1
GRAY
GRAY
BLACK
BLACK
5
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
RED
1
6
2
2
1
1
2 1
1 2 3 4 5 6 7 8 9
1
2
3 4 5 6 7
8
9
CN3
CN1CN13
6
6
5
5
4
4
3
3
CN10
2
2
1
1
7 6 5 4
CN17
3
2 1
7 6 5 4 3
2 1
CN11
CONTROLLER PCB ASSY ( MAIN PCB )
BLUE
5
5
PINK
4
4
YELLOW
3
3
ORANGE
CN12
2
2
RED
1
1
RED
BLACK
WHITE
YELLOW
BLUE
RED
BLACK
WHITE
YELLOW
BLUE
F M
FAN MOTOR ( UPPER )
F M
FAN MOTOR ( LOWER )
M
STEP MOTOR ( DAMPER LOCK LEFT )
SWITCH
SWITCH
REMOTE
CONTROL
UNIT
(OPTION)
3 2 1
BLACK
TEST
BLUE
BLACK
BLUE
BLACK
BLACK
WHITE
RED
(OPTION)
EX.IN
7 6 5 4 3 2 1
4
4
3
3
2
2
1
5 4 3 2 1
CN18
1
5 4 3
CN6
2 1
3 2
CN14
1
TM5
TM2TM1
565 4 3
CN8CN5
2 1
6 5 4 3 2 1
5 4 3
CN2
2 1
2 1
CN16
BLUE
6
PINK
4
YELLOW
3
ORANGE
2
RED
1
BLUE
6
PINK
5
YELLOW
4
ORANGE
3 2
RED
1
BLUE
5
PINK
4
YELLOW
3
ORANGE
2
RED
1
EX.OUT
(OPTION)
M
STEP MOTOR ( DAMPER LOCK RIGHT )
M
STEP MOTOR ( UP / DOWN )
M
STEP MOTOR ( DAMPER )
THERMAL FUSE 102
TERMINAL
RED
WHITE
2
1
3
TO OUTDOOR UNIT
Page 9
6. CAPACITY TABLE
6-1. COOLING CAPACITY
MODEL : AGF09LA
MODEL : AGF12LA
MODEL : AGF14LA
°CDB
°CWB
TC SHC TC SHCPI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
1.99 1.88 0.25 2.21 1.89 0.25 2.29 2.05 0.26 2.44 2.06 0.26 2.51 2.23 0.26 2.67 2.22 0.26 2.82 2.36 0.27
2.27 2.15 0.41 2.53 2.16 0.42 2.61 2.35 0.42 2.79 2.35 0.43 2.87 2.54 0.43 3.04 2.53 0.43 3.22 2.70 0.44
2.16 2.05 0.46 2.41 2.06 0.47 2.49 2.24 0.47 2.66 2.24 0.48 2.74 2.42 0.48 2.90 2.41 0.48 3.07 2.57 0.49
2.05 1.94 0.51 2.29 1.95 0.52 2.37 2.12 0.52 2.52 2.13 0.53 2.60 2.30 0.53 2.76 2.29 0.54 2.91 2.44 0.54
1.90 1.80 0.53 2.12 1.81 0.54 2.19 1.97 0.55 2.34 1.98 0.55 2.41 2.13 0.55 2.56 2.13 0.56 2.70 2.26 0.57
1.87 1.77 0.54 2.08 1.78 0.55 2.15 1.93 0.55 2.30 1.94 0.56 2.37 2.10 0.56 2.51 2.09 0.57 2.65 2.22 0.57
AFR
9.5
Indoor temperature
18212325272932
Outdoor temperature
°CDB
20
25
30
35
40
43
19212312151618
°CDB
°CWB
TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
2.67 2.17 0.45 2.98 2.19 0.45 3.08 2.38 0.45 3.28 2.39 0.46 3.38 2.58 0.46 3.59 2.57 0.47 3.79 2.73 0.47
3.05 2.48 0.74 3.40 2.50 0.75 3.52 2.72 0.75 3.75 2.73 0.76 3.87 2.94 0.76 4.10 2.93 0.77 4.33 3.12 0.78
2.91 2.37 0.82 3.24 2.38 0.83 3.36 2.59 0.84 3.58 2.60 0.85 3.69 2.81 0.85 3.91 2.79 0.86 4.13 2.98 0.87
2.76 2.25 0.91 3.08 2.26 0.92 3.18 2.46 0.93 3.39 2.47 0.94 3.50 2.66 0.94 3.71 2.65 0.95 3.92 2.83 0.96
2.56 2.08 0.95 2.86 2.10 0.96 2.95 2.28 0.97 3.15 2.29 0.98 3.25 2.47 0.98 3.44 2.46 0.99 3.63 2.62 1.00
2.52 2.05 0.96 2.80 2.06 0.97 2.90 2.24 0.98 3.09 2.25 0.99 3.19 2.43 0.99 3.38 2.42 1.00 3.57 2.57 1.01
AFR
9.5
20
192116
18
Indoor temperature
182123
23
Outdoor temperature
30
35
40
43
°CDB
25
12
15
252729
32
°CDB
°CWB
TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
3.42 2.61 0.62 3.81 2.63 0.63 3.94 2.86 0.63 4.20 2.87 0.64 4.33 3.10 0.64 4.59 3.08 0.65 4.85 3.28 0.66
3.66 2.80 0.91 4.08 2.81 0.92 4.22 3.06 0.93 4.50 3.07 0.93 4.64 3.31 0.94 4.91 3.30 0.95 5.19 3.51 0.96
3.50 2.67 1.00 3.90 2.69 1.02 4.03 2.92 1.02 4.30 2.93 1.03 4.43 3.16 1.04 4.69 3.15 1.05 4.96 3.36 1.06
3.32 2.53 1.10 3.70 2.55 1.12 3.82 2.77 1.12 4.07 2.78 1.13 4.20 3.00 1.14 4.45 2.99 1.15 4.70 3.18 1.16
2.94 2.25 1.14 3.28 2.26 1.16 3.39 2.46 1.17 3.61 2.47 1.18 3.73 2.66 1.19 3.95 2.65 1.20 4.17 2.82 1.21
2.78 2.12 1.16 3.10 2.13 1.17 3.20 2.32 1.18 3.41 2.33 1.19 3.52 2.51 1.20 3.73 2.50 1.21 3.94 2.67 1.22
AFR
10.8
°CDB
20
Outdoor temperature
12351819212315
16
25
30
40
43
Indoor temperature
18212325272932
AFR : Air Flow Rate (m3/min) TC : Total Capacity (kW) SHC : Sensible Heat Capacity (kW)
PI : PowerInput (kW)
PI
Page 10
6-2. HEATING CAPACITY
MODEL : AGF09LA
MODEL : AGF12LA
MODEL : AGF14LA
TC PI TC PI TC PI TC PI TC PI
3.53 1.44 3.45 1.47 3.37 1.50 3.28 1.53 3.20 1.56
3.67 1.54 3.58 1.57 3.50 1.60 3.41 1.63 3.32 1.67
4.18 1.61 4.08 1.64 3.98 1.68 3.88 1.71 3.78 1.74
4.84 1.72 4.72 1.75 4.61 1.79 4.49 1.82 4.38 1.86
5.35 1.72 5.23 1.76 5.10 1.80 4.97 1.83 4.84 1.87
5.46 1.38 5.33 1.41 5.20 1.44 5.07 1.47 4.94 1.50
5.14 1.39 5.02 1.42 4.89 1.45 4.77 1.48 4.65 1.51
5.42 1.16 5.29 1.19 5.16 1.21 5.03 1.24 4.90 1.26
AFR : Air Flow Rate (m3/min) TC ::Total Capacity (kW)
PI
:
PowerInput (kW)
AFR
10.8
Indoor temperature
°CDB16182022
24
O
utdoor
tempera
t
ure
°CDB
°CWB
-15
-16
-10
-11
-5
-7
0
-2
5
3
7
6
10
8
15
10
TC PI TC PI TC PI TC PI TC PI
3.04 0.96 2.97 0.98 2.89 1.00 2.82 1.02 2.75 1.04
3.34 1.01 3.26 1.04 3.18 1.06 3.10 1.08 3.02 1.10
3.78 1.06 3.69 1.09 3.60 1.11 3.51 1.13 3.42 1.15
4.40 1.14 4.30 1.16 4.20 1.18 4.09 1.21 3.99 1.23
4.89 1.21 4.77 1.24 4.66 1.26 4.54 1.29 4.42 1.31
4.72 1.14 4.61 1.17 4.50 1.19 4.39 1.21 4.27 1.24
5.43 1.16 5.30 1.18 5.17 1.20 5.04 1.23 4.91 1.25
5.43 1.09 5.30 1.11 5.17 1.14 5.04 1.16 4.91 1.18
AFR
10.0
Indoor temperature
°CDB16182022
24
Outdoor temperature
°CDB
°CWB
-15
-16
-10
-11
-5
-7
0
-2
5
3
7
6
10
8
15
10
TC PI TC PI TC PI TC PI TC PI
2.36 0.64 2.31 0.65 2.25 0.66 2.19 0.68 2.14 0.69
2.60 0.67 2.54 0.69 2.48 0.70 2.41 0.72 2.35 0.73
2.94 0.71 2.87 0.72 2.80 0.74 2.73 0.75 2.66 0.77
3.43 0.75 3.34 0.77 3.26 0.79 3.18 0.80 3.10 0.82
3.80 0.80 3.71 0.82 3.62 0.84 3.53 0.85 3.44 0.87
3.67 0.76 3.59 0.77 3.50 0.79 3.41 0.81 3.32 0.82
4.22 0.77 4.12 0.78 4.02 0.80 3.92 0.82 3.82 0.83
4.22 0.72 4.12 0.74 4.02 0.75 3.92 0.77 3.82 0.79
AFR
10.0
Indoor temperature
°CDB16182022
24
Outdoor temperature
°CDB
°CWB
-15
-16
-10
-11
-5
-7
0
-2
5
3
7
6
10
8
15
10
Page 11
7. FAN PERFORMANCE
7-1. AIR VELOCITY DISTRIBUTION
MODEL : AGF09LA, AGF12LA, AGF14LA
Note :
Fan speed : H i Operation : FAN Voltage : 230V Fan select : UPPER&LOWER
: UPPER FAN : LOWER FAN
SIDE VIEW FLOW CONTROL PANEL : Horiz. LOUVER :Center
0
1
2
3
(m)
(m)
1.0
0.5
Unit: m/s
1 2 3 4
SIDE VIEW FLOW CONTROL PANEL : Vert LOUVER :Center
Unit: m/s
0
1
2
3
(m)
1.0
0.5
1 2 3 4
(m)
TOP VIEW FLOW CONTROL PANEL : Horiz. LOUVER :Right & Left
TOP VIEW FLOW CONTROL PANEL : Horiz. LOUVER :Center
Unit: m/s
2
1
0
1
2
(m)
(m)
0.5
1 2 3 4
UPPER
LOWER
1.0
Unit: m/s
2
1
0
1
2
(m)
(m)
0.5
1 2 3 4
1.0
0.5
1.0
Page 12
MODEL : AGF09LA, AGF12LA
COOLING
7-2. AIR FLOW
HEATING
570
m3/h
158 l/s
335 CFM
460
m3/h
128 l/s
271 CFM
360
m3/h
100 l/s
212 CFM
270
m3/h
75 l/s
159 CFM
1190/1000
1000/850
820/690
660/560
HIGH
MED
LOW
QUIET
Fan speed
Number of rotations
[r.p.m]
(UPPER/LOWER)
Air flow
600
m3/h
167 l/s
353 CFM
480
m3/h
133 l/s
282 CFM
370
m3/h
103 l/s
218 CFM
270
m3/h
75 l/s
159 CFM
QUIET
660/560
840/700
1040/880
HIGH
1240/1040
MED
LOW
Fan speed
Number of rotations
[r.p.m]
(UPPER/LOWER)
Air flow
Page 13
MODEL : AGF14LA
COOLING
HEATING
650
m3/h
181 l/s
383 CFM
520
m3/h
144 l/s
306 CFM
400
m3/h
111 l/s
235 CFM
270
m3/h
75 l/s
159 CFM
LOW
QUIET
660/560
890/750
HIGH
1330/1120
1100/930
MED
Fan speed
Number of rotations
[r.p.m]
(UPPER/LOWER)
Air flow
650
m3/h
181 l/s
383 CFM
520
m3/h
144 l/s
306 CFM
390
m3/h
108 l/s
230 CFM
270
m3/h
75 l/s
159 CFM
LOW
QUIET
860/730
660/560
HIGH
1330/1120
1100/930
MED
Fan speed
Number of rotations
[r.p.m]
(UPPER/LOWER)
Air flow
Page 14
8-1. NOISE LEVEL CURVE
8. OPERATION NOISE
COOLING
Octave band sound pressure level, dB:(0dB=0.0002µbar)
Octave band center frequency,Hz
0
10
20
30
40
50
60
70
80
63 125 250 500 1,000 2,000 4,000 8,000
COOLING
Octave band sound pressure level, dB:(0dB=0.0002µbar)
Octave band center frequency,Hz
0
10
20
30
40
50
60
70
80
63 125 250 500 1,000 2,000 4,000 8,000
HEATING
MODEL : AGF09LA
MODEL : AGF12LA
High
Quiet
High
Quiet
NC-20
NC-40
NC-50
NC-60
NC-30
NC-15
NC-25
NC-35
NC-45
NC-55
NC-65
Octave band sound pressure level, dB:(0dB=0.0002µbar)
0
10
20
30
40
50
60
70
80
Octave band center frequency,Hz
63 125 250 500 1,000 2,000 4,000 8,000
High
Quiet
NC-20
NC-40
NC-50
NC-60
NC-30
NC-15
NC-25
NC-35
NC-45
NC-55
NC-65
HEATING
Octave band sound pressure level, dB:(0dB=0.0002µbar)
Octave band center frequency,Hz
0
10
20
30
40
50
60
70
80
63 125 250 500 1,000 2,000 4,000 8,000
High
Quiet
NC-20
NC-40
NC-50
NC-60
NC-30
NC-15
NC-25
NC-35
NC-45
NC-55
NC-65
NC-20
NC-40
NC-50
NC-60
NC-30
NC-15
NC-25
NC-35
NC-45
NC-55
NC-65
Page 15
COOLING
MODEL : AGF14LA
Octave band sound pressure level, dB:(0dB=0.0002µbar)
Octave band center frequency,Hz
0
10
20
30
40
50
60
70
80
63 125 250 500 1,000 2,000 4,000 8,000
High
Quiet
NC-20
NC-40
NC-50
NC-60
NC-30
NC-15
NC-25
NC-35
NC-45
NC-55
NC-65
Octave band sound pressure level, dB:(0dB=0.0002µbar)
0
10
20
30
40
50
60
70
80
Octave band center frequency,Hz
63 125 250 500 1,000 2,000 4,000 8,000
High
Quiet
NC-20
NC-40
NC-50
NC-60
NC-30
NC-15
NC-25
NC-35
NC-45
NC-55
NC-65
HEATING
Page 16
8-2.
SOUND LEVEL CHECK POINT
Microphone Microphone
Air Flow
1m
Air Flow
1m
Page 17
9. ELECTRIC CHARACTERISTICS
*1) Wiring Spec.
Selected Sample (Selected based on Japan Electrotechnical Standard and Codes Committee E0005)
AGF09LA AGF12LA AGF14LA
Voltage V
Frequency Hz
A 0.6 0.6 0.6
Circuit breaker A 0.7 0.7 0.7
Connection Cable
mm
2
1.5 - 2.5 1.5 - 2.5 1.5 - 2.5
Limited wiring length m 21 21 21
Model Name
Max Operating Current
*1)Wiring Spec.
Power Supply
230
50
Page 18
10. SAFETY DEVICES
AGF09LA AGF12LA AGF14LA
Circuit protection Current fuse (PCB)
Terminal protection Current fuse
Fan motor protection Thermal protection program
100
+15
-10
°C OFF
95
+5
-10
°C ON
Protection form
3.15A 250V
Model
3A 250V
Page 19
11.
Function number
Setting value
FUNCTION SETTING
F09-14LA
FLOOR TYPE
AG
INDOOR UNIT (Setting by remote controller)11 -1.
• The function settings of the control of the indoor unit can be changed by this procedure according
F09-14LA
FLOOR TYPE
AG
to the installation conditions. Incorrect settings can cause the indoor unit malfunction.
• After the power is turned on, perform the “FUNCTION SETTING” according to the installation conditions using the remote controller.
• The settings may be selected between the following two: Function Number or Setting Value.
•Settings will not be changed if invalid numbers or setting values are selected.
PREPARATION
•Turn on the power. * By turning on the power indoor units, so make sure the piping air-tight test and vacuuming have been conducted before turning on the power. * Also check again to make sure no wiring mistakes were made before turning on the power.
FUNCTION SETTING METHOD (for Wireless remote controller)
Entering the Function Setting Mode
While pressing the FAN button and SET TEMP. (
• setting mode.
STEP 1 Setting the Remote controller Signal Code
Use the following steps to select the signal code of the remote controller. (Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code.) The signal codes that are set through this process are applicable only to the signals in the FUNCTION SETTING. For details on how to set the signal codes through the normal process, refer to SELECTING THE REMOTE CONTROLLER SIGNAL CODE.
Press the SET TEMP. (1.
Match the code on the display to the air conditioner signal code. (initially
set to (If the signal code does not need to be selected, press the MODE button and proceed to STEP 2.)
Press the TIMER MODE button and check that the indoor unit can receive signals 2. at the displayed signal code.
Press the MODE button to accept the signal code, and proceed to STEP 2.3.
)
) ( ) button to change the signal code between
) simultaneously, press the RESET button to enter the function
The air conditioner signal code is set to A prior to shipment.
The remote controller resets to signal code A when the batteries in the remote controller are replaced. If you use a signal code other than signal code A, reset the signal code after replacing the batteries. If you do not know the air conditioner signal code setting, try each of the signal codes ( nd the code which operates the air conditioner.
STEP 2 Selecting the Function Number and Setting Value
Press the SET TEMP. (1. number. (Press the MODE button to switch between the left and right digits.)
Press the FAN button to proceed to setting the value.2. Press the FAN button again to return to the function number selection.)
Press the SET TEMP. (3. value. (Press the MODE button to switch between the left and right digits.)
Press the TIMER MODE button, and START/STOP button, 4. in the order listed to conrm the settings.
Press the RESET button to cancel the function setting 5. mode.
After completing the FUNCTION SETTING, be sure to turn 6. off the power and turn it on again.
) ( ) buttons to select the function
) ( ) buttons to select the setting
→ → → ) until you
CAUTION
After turning off the power, wait 10 seconds or more before turning on it again. The FUNCTION SETTING doesn’t become effective if it doesn’t do so.
- (01 - 18) -
Page 20
FUNCTION DETAILS
(... Factory setting)
Setting description Function number Setting value
Standard
31
00
Lower control 01
Slightly warmer control 02
Warmer control 03
3) Embedding the indoor unit in a wall
(... Factory setting)
Setting description Function number Setting value
Standard
In a wall
23
00 01 02
F09-14LA
FLOOR TYPE
AG
Functions Floor
1)
Cooler room temperature correction
F09-14LA
FLOOR TYPE
AG
Heater room temperature correction
2)
3)
Embedding the indoor unit in a wail
4) Auto restart
Indoor room temperature sensor
5) switching function
6) Remote controller signal code
1) Cooler room temperature correction
Depending on the installed environment, the room temperature sensor may require a correction. The settings may be selected as shown in the table below.
(... Factory setting)
Setting description Function number Setting value
Standard
Slightly lower control 01
Lower control 02
Warmer control 03
30
00
2) Heater room temperature correction
Depending on the installed environment, the room temperature sensor may require a correction. The settings may be changed as shown in the table below.
-
- (01 - 19) -
Page 21
F09-14LA
FLOOR TYPE
AG
4) Auto restart
F09-14LA
FLOOR TYPE
AG
Enable or disable automatic system restart after a power outage.
(... Factory setting)
Setting description Function number Setting value
Yes
No 01
40
00
* Auto restart is an emergency function such as for power failure etc.
Do not start and stop the indoor unit by this function in normal operation. Be sure to operate by the control unit, or external input device.
5) Indoor room temperature sensor switching function
(Only for Wired remote controller)
The following settings are needed when use the control by Wired remote controller temperature sensor.
(... Factory setting)
Setting description Function number Setting value
No
Yes 01
42
00
* If setting value is “00” :
Room temperature is controlled by the indoor unit temperature sensor.
* If setting value is “01” :
Room temperature is controlled by either indoor unit temperature sensor or remote controller unit sensor.
6) Remote controller signal code
Change the indoor unit Signal Code, depending on the remote controllers.
(... Factory setting)
Setting description Function number Setting value
A
B 01 C 02 D 03
44
00
- (01 - 20) -
Page 22
F09-14LA
FLOOR TYPE
AG
REMOTE CONTROLLER SIGNAL CODE SETTING
Use the following steps to select the signal code of the remote controller. (Note that the air conditioner cannot receive a signal code if the air conditioner has
not been set for the signal code.)
Press the START/STOP button until only the clock is displayed on the remote 1. controller display.
Press the MODE button for at least ve seconds to display the current signal code 2. (initially set to
Press the SET TEMP. (3.
→ .
Match the code on the display to the air conditioner signal code.
Press the MODE button again to return to the clock display. The signal code will 4. be changed.
If no buttons are pressed within 30 seconds after the signal code is displayed, the system returns to the original clock display. In this case, start again from step 1.
The air conditioner signal code is set to A prior to shipment. Contact your retailer to change the signal code.
The remote controller resets to signal code A when the batteries in the remote controller are replaced. If you use a signal code other than signal code A, reset the signal code after replacing the batteries. If you do not know the air conditioner signal code setting, try each of the signal codes ( operates the air conditioner.
).
) ( ) button to change the signal code between
→ → → ) until you nd the code which
F09-14LA
FLOOR TYPE
AG
- (01 - 21) -
Page 23
12. OPTIONAL PARTS
Exterior Summary
Parts name
Wired remote
controller
Apple-catechin
filter
Ion deodorisation
filter
Half concealed
External
connect kit
kit
Model No.
UTB-UD
UTR-FC03-2
UTR-FC03-3
UTR-STA
UTY-XWZX
Unit control is performed by
wired remote controller.
Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol ingredient extracted from apples.
The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra fine-particle ceramic.
Use to connect with various peripheral devices and air conditioner PC board.
Using the Unit installing of half concealed.
SUMOTUWETH FR
SA
AM
PM
3 6 9
12 15 18 21
Page 24
12-1. WIRED REMOTE CONTROLLER
FEATURES
Simple function setting
Setting of the air conditioner selection function is performed by remote controller.
High performance and compact size
Various timer setup (ON / OFF / WEEKLY) are possible. Equipped with weekly timer as standard function.
(2 times Start / Stop per day for a week) When setting up a timer, operation mode and a temperature
setup can be changed. When a failure occurs,the error code is displayed. Error indication. Economy operation are possible. Easy installation with a slim shape with no bulge in the back.
Three functions are combined in one unit.
Wired
remote
controller
Built-in timers
Possible to set ON/OFF time to operate twice each day of the week.
SUMOTUWETH FR SA
7
Setup screen example (Set to Wednesday: 8:00 to 20:00.)
3126 9
15 18 21
0 3 6 9 12 15 18 21 Time
At "Weekly timer" + "Set back timer" setup
Easy-to-understand time bar display
SUMOTUWETH FR SA
7
3126 9
15 18 21
24°C
24°C 28°C 24°C
Weekly
timer
Setback
timer
Setback timerWeekly timer
Possible to set temperature for two time spans and for each day of the week.
SUMOTUWETH FR SA
Screen after setup
Setup screen example (Set from Sunday to Saturday: 12:00 to 15:00, 28 °C.)
0 3 6 9 12 15 18 21 Time
24°C
0 3 6 9 12 15 18 21 Time
28°C
3126 9
15 18 21
28°C
Easy-to-understand operation Simple installation
Components are compatible with standard switch boxes. Flat back construction allows equipment to be installed wherever it is needed.
Timer area
[
Variable timer control
]
The operation/display sections are zoned accord­ing to time and operation, enabling variable pro­gramming to match application.
Operation area
European switch box
JIS box
Page 25
FUNCTIONS
Display panel
10
11
1
START/STOP button
Pressed to start and stop operation.
2
Set temperature button
Selects the setting temperature.
3
Master control button
15
2 6 7 8 9
19
20
16
18
1 3
4
13
12
5
14
17
Selects the operating mode(AUTO, HEAT, FAN, COOL, DRY).
4
Fan control button
Selects the fan speed (AUTO, QUIET, LOW, MED, HIGH).
5
Economy button
Turns the economy efficient mode on and off.
6
Timer mode (CLOCK ADJUST) button
Selects the timer mode (OFF TIMER, ON TIMER, WEEKLY TIMER) Set the current time.
7
Day (DAY OFF) button
Temporarily cancels of one day timer.
8
Set back button
Pressed to select the set back timer.
9
Set time button
Pressed to set time.
10
Delete button
The schedule of a weekly timer is deleted.
11
Set button
Sets the date, hour, minute and on-off time.
12
Vertical airflow direction and swing button
Push for two seconds to change the swing mode.
13
Horizontal airflow direction and swing button
Push for two seconds to change the swing mode.
DIMENSION
120
Front View
SPECIFICATION
21
[ Unit : mm ]
120
14
Filter button
15
Operation lamp
Lights during operation and when the timer is on.
16
Timer and clock display
17
17
Operation mode display
18
Fan speed display
19
Operation lock display
20
Temperature display
21
Function display
Defrost display
Thermo sensor display
Economy display
Vertical swing display
Horizontal sw
ing display
Filter display
SIZE (H x W x D mm) 120 x 120 x 17
WEIGHT ( g ) 160
CABLE LENGTH ( m )
POWER ( V )
10
12
Button number 13 and can not be operated.
14
Page 26
12-2. EXTERNAL CONNECT KIT
Orange
External
input
External
output
1
3
Yellow
Indoor unit External device
( Field supply )
Print circuit
board
Orange
External
input
External
1
3
Yellow
Indoor unit External device
( Field supply )
Print circuit
board
This kit allows to operate the air conditioner, such as stopping and starting, using an external device, and output the operation status of the air conditioner.
• Only operation and stop signals will be output. Use the remote control to check the operation mode, temperature, and airflow. Check the error information on the display area of the main unit.
• Operation mode, temperature, and airflow cannot be set by external input. Use the remote controller to set.
• If the air-conditioner is activated by external input, it will operate in the settings before stop. To change the settings, use the remote controller.
12-2-1. CONTROL INPUT SETTING
• You can control air conditioner ON / OFF operation by external input.
Signal specification
• No voltage ON/OFF continuous signal.
• Contact capacity : DC12V 10mA
External input signal
ON
OFF
Remote controller signal
OPERATION
Indoor unit status
Installation example
• For remote operation
For external timer operation
ON ONOFF OFF
STOP
Page 27
12-2-2. Operating output setting
• You can display air conditioner ON / OFF operation by external output.
Signal specification
• No voltage contact.
• Contact capacity : Max. DC24V 10mA to 1A or less
OPERATION
Indoor unit status
STOP
SHORT
External output signal
OPEN
Installation example
For operation display
Indoor unit
Print circuit
board
External
input
External
output
1 2
Blue
Purple
External device
( Field supply )
Ic
Vc
Page 28
R410A
D1D_AO006E/03
2009.03.04
2.
SINGLE TYPE :
AO V09LAC
AO V12LAC
AO V14LAC
OUTDOOR UNIT
Page 29
- (02 - 01) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
1. SPECIFICATIONS
AO V09LAC AO V12LAC AO V14LAC
A 3.8 5.5 6.4
1,680 1,680 1,910
1,490 1,680 1,750
Propeller fan × 1 Propeller fan × 1 Propeller fan × 1
W 56
47 48 50
48 49 50
504 × 850 × 36.4 504 × 850 × 36.4 546 × 876 × 36.4
1.40 1.40 1.30
2 × 24 2 × 24 2 × 26
Copper Copper Copper
Aluminium Aluminium Aluminium
Rotary × 1 Rotary × 1 Rotary × 1
W 750 750 1,100
R410A R410A R410A
g 1,050 1,050 1,150
ESTER OIL ESTER OIL ESTER OIL
Steel Steel Steel
Beige Beige Beige
540 × 790 × 290 540 × 790 × 290 578 × 790 × 300
648 × 910 × 380 648 × 910 × 380 648 × 910 × 380
36 (79) 36 (79) 40 (88)
40 (88) 40 (88) 44 (97)
12.70 ( 1/2 in.)
Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27°CDB/19 °CWB. and outdoor temperature of 35°CDB/24°CWB. Heating : Indoor temperature of 20°CDB/15°CWB. and outdoor temperature of 7°CDB/6°CWB. Pipe length : 5 m, Height difference : 0 m. (Outdoor unit - Indoor unit)
Material
Colour
Net
Gross
Motor output
Type
Charge
Type
Rows × Stages
Pipe type
Fin type
Type × Q'ty
Motor output
Cooling
Heating
Dimensions (H × W × D)
Type
Model name
Power source
Available voltage range
-15 to 24
Flare
20 (chargeless : 15)
15
-10 to 43
230V 50Hz
198 - 264V 50Hz
9.52 ( 3/8 in.)
6.35 ( 1/4 in.)
m
Connection pipe
Size
mm
Liquid
Gas
Method
Max. length
Max. height difference
Compressor
Refrigerant
Sound pressure level Starting current
Cooling
Heating
Type × Q'ty
mm
mm
Weight
kg(lb.)
Dimensions (H × W × D)
Refrigerant oil
Enclosure
Heat exchanger type
Fin pitch
Net
INVERTER HEAT PUMP
°C
Operation range
Fan Airflow
rate
m3/h
dB(A)
Gross
Cooling
Heating
33 33
Page 30
- (02 - 02) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
2. DIMENSIONS
MODEL : AO V09LA, AO V12LA
(Unit : mm)
INSTALLATION PLACE
347
578
48
10
320
508
540
20
300
125
60
790
540
790
56
290
353
17
MODEL : AO V14LA
100 mm or more
600 mm or more
100 mm or more
200 mm or more
250 mm or more
50 mm or more
540 125
Page 31
- (02 - 03) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
MODEL : AO V09LA, AO V12LA, AO V14LA
3. REFRIGERANT CIRCUIT
2-Way
valve
Strainer
Strainer
3-Way
valve
Muffler
4-Way valve
Expansion valve
Indoor unit Heat exchanger
Outdoor unit Heat exchanger
Compressor
Refrigerant direction
Heating
Cooling
Page 32
- (02 - 04) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
MODEL : AO V09LA, AO V12LA, AO V14LA
4. WIRING DIAGRAMS
WHITE
RED
YELLOW
YELLOW
BLACK BLACK
BROWN
BROWN
BLACK
BLACK
RED
WHITE
BLACK
GREEN
BLACK
BLACK
BLACK
WHITE
BLACK
BLACK
WHITE
YELLOW
ORANGE
BLUE
BROWN
RED
BLUE
YELLOW
WHITE
BLACK
RED
BLACK
WHITE
RED
BLACK
WHITE
RED
1 2 3
4
5
6
1
2
3
1 2 3
4
5
6
1 2 3 4 5 6
1
2 3 4 5 6
1 2 3
1
2
3
1 2 3 4
1 2 3 4
1 2 3
1 2 3
221
1
1 2 3
CN71
CN70
W10 W11
W4
W2
W1
W3
CN30
CN40
CN800
W7 W8 W9
FUSE
250V
20A
FUSE
250V 15A
TERMINAL
TO INDOOR UNIT POWER SOURCE
L N32
1
4-WAY VALVE
EXPANSION VALVE
FAN MOTOR
COMPRESSOR
PIPE THERMISTOR
DISCHARGE PIPE THERMISTOR
OUTDOOR THERMISTOR
CM
FM
PMV
S ( S )
R ( R )
C ( T )
4WV
WHITE
RED
REACTOR
AO V09, 12L
AO V14L
Page 33
- (02 - 05) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
5. CAPACITY COMPENSATION RATE FOR PIPE LENGTH AND HEIGHT DIFFERENCE
MODEL : AO V09LA, AO V12LA
Indoor unit
Height difference H
Connection pipe
H
Outdoor unit
Indoor unit
Connection pipe
H
Outdoor unit
Indoor unit is upper than outdoor unit.
1
Indoor unit is under than outdoor unit.
2
5 7.5 10 15 20
15 - - - 0.915 0.905
10 - - 0.955 0.922 0.912
7.5 - 0.974 0.959 0.926 0.916
5 0.992 0.978 0.963 0.930 0.920
0 1.000 0.986 0.971 0.937 0.927
-5 1.000 0.986 0.971 0.937 0.927
-7.5 - 0.986 0.971 0.937 0.927
-10 - - 0.971 0.937 0.927
-15 - - - 0.937 0.927
5 7.5 10 15 20
15 - - - 0.863 0.846
10 - - 0.944 0.863 0.846
7.5 - 0.978 0.944 0.863 0.846
5 1.000 0.978 0.944 0.863 0.846
0 1.000 0.978 0.944 0.863 0.846
-5 0.995 0.973 0.939 0.858 0.842
-7.5 - 0.971 0.937 0.856 0.840
-10 - - 0.934 0.854 0.838
-15 - - - 0.794 0.778
HEATING
COOLING
1
Indoor unit is upper
than outdoor unit.
2
Indoor unit is under
than outdoor unit
Height
difference H
(m)
Pipe length (m)
Pipe length (m)
Height
difference H
(m)
1
Indoor unit is upper
than outdoor unit.
2
Indoor unit is under
than outdoor unit
Page 34
- (02 - 06) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
MODEL : AO V14LA
Indoor unit
Height difference H
Connection pipe
H
Outdoor unit
Indoor unit
Connection pipe
H
Outdoor unit
Indoor unit is upper than outdoor unit.1 Indoor unit is under than outdoor unit.2
5 7.5 10 15 20
15 - - - 0.950 0.946
10 - - 0.976 0.958 0.954
7.5 - 0.984 0.980 0.962 0.958
5 0.992 0.988 0.984 0.966 0.962
0 1.000 0.996 0.992 0.974 0.969
-5 1.000 0.996 0.992 0.974 0.969
-7.5 - 0.996 0.992 0.974 0.969
-10 - - 0.992 0.974 0.969
-15 - - - 0.974 0.969
5 7.5 10 15 20
15 - - - 0.853 0.824
10 - - 0.943 0.853 0.824
7.5 - 0.982 0.943 0.853 0.824
5 1.000 0.982 0.943 0.853 0.824
0 1.000 0.982 0.943 0.853 0.824
-5 0.995 0.977 0.938 0.848 0.820
-7.5 - 0.975 0.936 0.846 0.818
-10 - - 0.933 0.844 0.816
-15 - - - 0.785 0.758
Height
difference H
(m)
1
Indoor unit is upper
than outdoor unit.
2
Indoor unit is under
than outdoor unit
Pipe length (m)
Pipe length (m)
HEATING
COOLING
1
Indoor unit is upper
than outdoor unit.
2
Indoor unit is under
than outdoor unit
Height
difference H
(m)
Page 35
- (02 - 07) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
6. ADDITIONAL CHARGE CALCULATION
MODEL : AO V09LA, AO V12LA, AO V14LA
REFRIGERANT CHARGE
Refrigerant amount g
Pipe length m 15 20
Additional charge g 0 (Chargeless) +100
MODEL
Refrigerant type
20g/m
AO V09LA
AO V12LA
AO V14LA
R410A
1,050
R410A
1,150
R410A
1,050
Page 36
- (02 - 08) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
MODEL : AO V09LA, AO V12LA, AO V14LA
COOLING
7. AIR FLOW
HEATING
MODEL
Number of rotations r.p.m. 760 r.p.m. 760 r.p.m. 820
m3/h
1680
m3/h
1680
m3/h
1910
l/s 467 l/s 467 l/s 531
CFM 989 CFM 989 CFM 1124
MODEL
Number of rotations r.p.m. 680 r.p.m. 760 r.p.m. 750
m3/h
1490
m3/h
1680
m3/h
1750
l/s 414 l/s 467 l/s 486
CFM 877 CFM 989 CFM 1030
Air flow
Air flow
AO V14LA
AO V14LA
AO V09LA
AO V09LA
AO V12LA
AO V12LA
Page 37
- (02 - 09) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
8-1. NOISE LEVEL CURVE
8. OPERATION NOISE
MODEL : AO V09LA
MODEL : AO V09LA MODEL : AO V12LA
COOLING
HEATING
MODEL : AO V12LA
Octave band sound pressure level, dB:(0dB=0.0002µbar)
Octave band center frequency,Hz
0
10
20
30
40
50
60
70
80
63 125 250 500 1,000 2,000 4,000 8,000
NC-20
NC-40
NC-50
NC-60
NC-30
NC-15
NC-25
NC-35
NC-45
NC-55
NC-65
Octave band sound pressure level, dB:(0dB=0.0002µbar)
0
10
20
30
40
50
60
70
80
Octave band center frequency,Hz
63 125 250 500 1,000 2,000 4,000 8,000
NC-20
NC-40
NC-50
NC-60
NC-30
NC-15
NC-25
NC-35
NC-45
NC-55
NC-65
Octave band sound pressure level, dB:(0dB=0.0002µbar)
Octave band center frequency,Hz
0
10
20
30
40
50
60
70
80
63 125 250 500 1,000 2,000 4,000 8,000
NC-20
NC-40
NC-50
NC-60
NC-30
NC-15
NC-25
NC-35
NC-45
NC-55
NC-65
Octave band sound pressure level, dB:(0dB=0.0002µbar)
Octave band center frequency,Hz
0
10
20
30
40
50
60
70
80
63 125 250 500 1,000 2,000 4,000 8,000
NC-20
NC-40
NC-50
NC-60
NC-30
NC-15
NC-25
NC-35
NC-45
NC-55
NC-65
Page 38
- (02 - 10) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
MODEL : AO V14LA
MODEL : AO V14LA
COOLING
HEATING
Octave band sound pressure level, dB:(0dB=0.0002µbar)
Octave band center frequency,Hz
0
10
20
30
40
50
60
70
80
63 125 250 500 1,000 2,000 4,000 8,000
NC-20
NC-40
NC-50
NC-60
NC-30
NC-15
NC-25
NC-35
NC-45
NC-55
NC-65
Octave band sound pressure level, dB:(0dB=0.0002µbar)
0
10
20
30
40
50
60
70
80
Octave band center frequency,Hz
63 125 250 500 1,000 2,000 4,000 8,000
NC-20
NC-40
NC-50
NC-60
NC-30
NC-15
NC-25
NC-35
NC-45
NC-55
NC-65
Page 39
- (02 - 11) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
8-2. SOUND LEVEL CHECK POINT
Page 40
- (02 - 12) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
9. ELECTRIC CHARACTERISTICS
AO V09LA AO V12LA AO V14LA
Voltage V
Frequency Hz
A 10.0 10.0 13.5
A 3.8 5.5 6.4
Main Fuse (Circuit breaker) Current
A 20 20 20
Power Cable
mm
2
1.5 - 2.5 1.5 - 2.5 1.5 - 2.5
*2)Limited wiring length m 15 15 11
*1) Wiring Spec. Selected Sample (Selected based on Japan Electrotechnical Standard and Codes Committee E0005)
*2) Limited Wiring length : This is the wiring length in case voltage descent is less than 2%. When the wiring length becomes long, please select the wiring of a more larger diameter.
Model Name
Power Supply
*1) Wiring Spec.
230
50
Max Operating Current
Starting Current
Page 41
- (02 - 13) -
OUTDOOR UNIT
AO V09-12-14LA
OUTDOOR UNIT
AO V09-12-14LA
10. SAFETY DEVICES
Fan motor protection Thermal protection program
Compressor protection
Thermal protection program (DISCHARGE TEMP.)
OFF : 100
+15
-10
°C
ON : 95
+15
-10
°C
OFF : 110°C
ON : After 7 minutes
20A 250V
5A 250V
15A 250V
3.15A 250V
15A 250V
3.15A 250V
OFF : 100
+15
-10
°C
ON : 95
+15
-10
°C
OFF : 110°C
ON : After 7 minutes
Protection form
20A 250V
5A 250V
AO V09LA
Model
AO V14LA
20A 250V
5A 250V
AO V12LA
15A 250V
3.15A 250V
Circuit protection
OFF : 110°C
ON : After 7 minutes
Current fuse (NEAR THE TERMINAL)
Current fuse (MAIN PRINTED CIRCUIT BOARD)
OFF : 100
+15
-10
°C
ON : 95
+15
-10
°C