– 1 –
SPECIFICATIONS
TYPE COOLING
INDOOR UNIT ABY24AGB-W
OUTDOOR UNIT AOY24ANA
COOLING CAPACITY (W) 6,550 - 6,750
POWER SOURCE (V) 220 - 240
FREQUENCY (Hz) 50
RUNNING CURRENT (A) 13.2 -13.4
INPUT (W) 2,670 - 2,780
EER (W/W) 2.45 - 2.42
MOISTURE REMOVAL (r/hr) 3.4
AIR CIRCULATION-Hi (m
3
/hr) 900
ELECTRICAL DATA
COMPRESSOR
DIMENSIONS
TYPE
Hermetic type, Permanent split condenser,
2 pole, Single phase, Induction motor
CODE 2JS438D5AA02
REFRIGERANT R-22 (g) 1,870
POWER SOURCE (V) 240
TYPE MFA-24CTA
INDOOR UNIT
HI-SPEED (r.p.m.) 1,180
MED-SPEED (r.p.m.) 1,040
LO-SPEED (r.p.m.) 900
OUTDOOR UNIT
TYPE MFB-247FB
FAN SPEED (r.p.m.) 735
INDOOR UNIT
H x W x D (mm)
199 x 990 x 655
OUTDOOR UNIT 643 x 840 x 336
FAN MOTOR
WEIGHTS
ADDITIONAL REFRIGERANT CHARGE
INDOOR UNIT
GROSS / NET (kg)
39 / 30
OUTDOOR UNIT 68 / 60
PIPE LENGTH 5 m ( 16 ft. ) 7 m ( 23 ft. ) 10 m ( 33 ft. ) 15 m ( 49 ft. ) 20 m ( 66 ft. )
FULL CHARGE AMOUNT 1,870 g (66.0 oz.) 1,902 g (67.1 oz.) 1,950 g (68.8 oz.) 2,030 g (71.6 oz.) 2,110 g (74.4 oz.)
Note : In the case that 5 m are exceeded, when using a connection pipe other than that in the table,
charge additional refrigerant with 16 g (0.56 oz.) / 1 m (3.3 ft.) as the criteria.