Fujitsu ABT30RG, ABT36RG3, ABT36RG, ABT36AG, ABT36AG3 Operating Manual

...
KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE
P/N9361092013-02
OPERATING MANUAL
Indoor Unit
ABT30AG ABT30RG ABT36AG(3) ABT36RG(3) ABT45AG(3) ABT45RG(3) ABT54AG(3) ABT54RG(3)
Outdoor Unit
AOT30AB AOT30RB AOT36AC(3) AOT36RC(3) AOT45AC(3) AOT45RC(3) AOT54AB(3) AOT54RB(3)
AIR CONDITIONER
CEILING SUSPENSION TYPE
2
CONTENTS
SAFETY PRECAUTIONS ....................................... 2
FEATURES AND FUNCTIONS .............................. 3
NAME OF PARTS ................................................... 4
PREPARATION ....................................................... 6
OPERATION ........................................................... 7
TIMER OPERATION ............................................... 9
SLEEP TIMER OPERATION ................................. 10
ADJUSTING THE DIRECTION OF
AIR CIRCULATION ............................................... 11
SWING OPERATION ............................................ 12
ENERGY SAVE OPERATION ............................... 13
MANUAL AUTO OPERATION ............................. 13
CLEANING AND CARE ........................................ 14
TROUBLESHOOTING .......................................... 15
OPERATING TIPS................................................. 16
DANGER!
Do not attempt to install this air conditioner by yourself.
This unit contains no user-serviceable parts. Always consult authorized service per-
sonnel for repairs.
When moving, consult authorized service personnel for disconnection and installa­tion of the unit.
Do not become over-exposed to cold air by staying in the direct path of the airflow of the air conditioner for extended periods of time.
Do not insert fingers or objects into the outlet port or intake grilles.
Do not start and stop air conditioner operation by turning off the electrical breaker
and so on.
In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical breaker, and consult authorized service personnel.
Provide occasional ventilation during use.
Do not direct air flow at fireplaces or heating apparatus.
Do not climb on, or place objects on, the air conditioner.
Do not hang objects from the indoor unit.
Do not set flower vases or water containers on top of air conditioners.
Do not expose the air conditioner directly to water.
Do not operate the air conditioner with wet hands.
Turn off power source when not using the unit for extended periods.
Always turn off the electrical breaker whenever cleaning the air conditioner or chang-
ing the air filter.
Connection valves become hot during Heating; handle with care.
Check the condition of the installation stand for damage.
Do not place animals or plants in the direct path of the air flow.
When restarting after a long period of disuse in the winter, do:
Turn the power switch on at least 12 hours before starting the unit.
Do not drink the water drained from the air conditioner.
Do not use in applications involving the storage of foods, plants or animals, precision
equipment, or art works.
Do not apply any heavy pressure to radiator fins.
Operate only with air filters installed.
Do not block or cover the intake grille and outlet port.
Ensure that any electronic equipment is at least one metre away from either the in-
door or outdoor units.
Avoid installing the air conditioner near a fireplace or other heating apparatus.
Whe
n installing the indoor and outdoor unit, take precautions to prevent access to infan
ts.
Do not use inflammable gases near the air conditioner.
CAUTION!
SAFETY PRECAUTIONS
Before using the appliance, read these “PRECAUTIONS” thoroughly and operate in the correct way.
The instructions in this section all relate to safety; be sure to maintain save operating conditions.
“CAUTION” and “DANGER” have the following meanings in these instructions:
DANGER!
CAUTION!
This mark indicates procedures which, if improperly performed, might lead to the death or serious injury of the user.
This mark indicates procedures which , if improperly performed, might possibly result in personal harm to the user, or damage to property.
3
FEATURES AND FUNCTIONS
AUTOMATIC OPERATION
COOLING MODEL
Merely press the START/STOP button, and the unit will begin automatic operation in the Cooling or Dry mode as appropriate, in accordance with the thermostat setting and the actual temperature of the room.
HEAT & COOL MODEL (REVERSE CYCLE)
Merely press the START/STOP button, and the unit will begin automatic operation in either the Heating, Cooling or Monitor modes as appropriate, in accordance with the thermostat setting and the actual temperature of the room.
SLEEP TIMER
COOLING MODEL
When the SLEEP timer button is pressed during Cooling or Dry mode, the thermostat setting is gradually raised during the period of operation. When the set time is reached, the unit automatically turns off.
HEAT & COOL MODEL (REVERSE CYCLE)
When the SLEEP timer button is pressed during Heating mode, the air conditioner’s thermostat setting is gradu­ally lowered during the period of operation; during Cool­ing or Dry mode, the thermostat setting is gradually raised during the period of operation. When the set time is reached, the unit automatically turns off.
WIRELESS REMOTE CONTROL UNIT
The WIRELESS REMOTE CONTROL UNIT allows convenient control of air conditioner operation.
OMNI-DIRECTIONAL AIR FLOW (SWING OPERATION)
Three-dimensional control over air direction swing is possi­ble through dual use of both an UP/DOWN air direction swing and RIGHT/LEFT air direction swing. Since UP/DOWN air direction flaps operate automatically according to the oper­ating mode of the unit, it is possible to set air direction based on the operating mode.
MILDEW-RESISTANT FILTER
The AIR FILTER has been treated to resist mildew growth, thus allowing cleaner use and easier care.
4
SLEEP
TIMER
SET TIME
SET TEMP
MASTER
CONTROL
FAN
CONTROL
START
STOP
.
SET
ENERGY
SAVE
TIME
ADJUST
TEST RUN ACL
SET
SWING
SWING
CLOCK
OFF ON
TIMER RESET
TIMER
SLEEP
HM
OFF
AUTO
COOL DRY FAN
ENERGY SAVE
HEAT
ON
A
AUTO
HIGH MED LOW
C
F
G
H
I
J
R
U
V
W
X
Y
S
T
K L
M
N O P
D
E
Q
CLOCK
COOL
AUTO
*
Instructions relating to heating(*) are applicable only to HEAT & COOL MODEL (Reverse Cycle).
NAME OF PARTS
Fig. 5
Fig. 1
Fig. 4
Fig. 3
Fig. 6
Fig. 7
This breaker is installed during the electrical installation.
SWING SWING TIMER
OPERATION
MANUAL
AUTO
3
4567
2
1
A
A
B
9
8
0
A
A
B
Electrical Breaker
Fig. 2
5
Fig. 5 Remote Control Unit
C SLEEP Button D MASTER CONTROL Button E SET TEMP./SET TIME Buttons ( ) F Signal Transmitter G TIMER Button H FAN CONTROL Button I START/STOP Button J Battery compartment lid
Inside of the battery compartment lid (Fig. 6)
K AIR FLOW DIRECTION Button L ENERGY SAVE Button M CODE CHANGE (Slide Switch)
Switching the remote control unit code. (Max. 4 units)
N TIME ADJUST Button O TEST RUN Button
This button is used when installing the air conditioner and should not be used under normal conditions as it will cause the air conditioner’s thermostat function to oper- ate incorrectly.
If this button is pressed during normal op­eration, the unit will switch to test opera­tion mode, and the indoor unit’s OPERA- TION indicator lamp and TIMER indicator lamp will begin to flash simultaneously.
To stop the test operation mode, either press the TEST RUN button once again, or press the START/STOP button to stop the air conditioner.
P ACL Button
Q Remote Control Unit Display (Fig. 7) R Transmit Indicator S Clock Display T Operating Mode Display U Timer Mode Display V Fan Speed Display W Temperature Set Display X Timer Set Indicator Y Temperature Set Indicator
Fig. 1 Indoor Unit
1 Operating Control Panel (Fig. 2) 2 MANUAL AUTO button 3 Remote Control Signal Receiver 4 OPERATION Indicator Lamp (red) 5 TIMER Indicator Lamp (green) 6 SWING Indicator Lamp (orange)
(HORIZONTAL SWING)
7 SWING Indicator Lamp (orange)
(VERTICAL SWING)
If the TIMER indicator lamp flashes when
the timer is operating, it indicates that a fault has occurred with the timer setting
(See Page 17 Auto Restart).
8 Intake Grille 9 UP/DOWN Air Direction Flap 0 RIGHT/LEFT Air Direction Louvers
(behind UP/DOWN Air Direction Flap)
Fig. 4 Outdoor Unit
A Intake Port B Outlet Port
6
PREPARATION
Load Batteries (R03/LR03
××
××
× 4)
1
Press and slide the battery compartment lid to open it.
2
Insert batteries.
Be sure to align the battery polarities ( ) correctly.
3
Close the battery compartment lid.
Set the Current time
1
Press the TIME ADJUST button.
Use the tip of a ball-point pen or other small object to press the button.
2
Use the ( )SET TIME buttons to adjust the clock to the current time.
button: Press to advance the time. button: Press to reverse the time.
(Each time the buttons are pressed, the time will be advanced/reversed in one-minute increments; hold the buttons depressed to change the time quickly in ten-minute increments.)
3
Press the TIME ADJUST button again.
This completes the time setting and starts the clock.
To Use the Remote Control Unit
The remote control unit must be pointed at signal receiver to operate correctly.
Operating range: About 7 meters.
When a signal is properly received by the air conditioner, a beeping sound will
be heard.
If no beep is heard, press the remote control unit button again.
Remote Control Unit Holder
For use as Handy Type
CAUTION!
Take care to prevent infants from accidentally swallowing batteries.
When not using the remote control unit for an extended period, remove the batteries to avoid possible leakage and damage to the unit.
If leaking battery fluid comes in contact with your skin, eyes, or mouth, immedi­ately wash with copious amounts of water, and consult your physician.
Dead batteries should be removed immediately and disposed of properly, either in a battery collection receptacle or to the appropriate authority.
Do not attempt to recharge dry batteries.
Never mix new and used batteries, or batteries of different types. Batteries should last about one year under normal use. If the remote control units operating range becomes appre­ciably reduced, replace the batteries and press the ACL button with the tip of a ballpoint pen or other small object.
SET
ENERGY
SAVE
TIME
ADJUST
TEST
RUN ACL
SET
SWING
SWING
1 Mount the Holder.
Screws
2 Set the Remote
Control Unit.
Insert
Slide up
3 To remove the Remote
Control Unit (when use at hand).
Screws
1 Mount the Holder.
For use as Wall Fixing Type
Slide
3 Attach the unit to the
holder as shown.
Screw
Insert
2 Set the Remote
Control Unit.
Loading...
+ 11 hidden pages