This document describes the Fujitsu 3.2 TB Flash Accelerator Card for product models 7119601 and
7119603, which may be mounted on the Oracle or Fujitsu SPARC M12/M10 system.
Before you read this document, we recommend reading the
M10/SPARC M10 Systems Quick Guide
Fujitsu SPARC
Fujitsu SPARC M12 and SPARC M12 are identical products.
Fujitsu M10 is sold as SPARC M10 by Fujitsu in Japan.
Fujitsu M10 and SPARC M10 are identical products.
The preface includes the following sections:
-Using the Product Safely
-Organization and Contents of This
-Related Manuals
-Text Conventions
-Warning/Importance Indications
-Document Feedback
-Revision History
M12 is sold as SPARC M12 by Fujitsu in Japan.
.
Manual
Fujitsu SPARC M12 Quick Guide
or
Fujitsu
Using the Product Safely
Handling of This Manual
This manual contains important information necessary for using this product safely. Read this manual and
the manuals described in "Related Manuals" thoroughly before using the product. In particular, before
attempting to use the product, carefully read and understand the safety precautions described in these
various manuals.
Keep this manual in
Fujitsu makes every effort to prevent injury to users and bystanders as well as property damage. Be sure to
use the product in accordance with the instructions in this manual.
Product Notice
This product is designed and manufactured for use in standard applications such as office work, personal
devices, and general industrial use. This product is not intended for special uses (nuclear-reactor control in
atomic energy facilities, aeronautic and space systems, air traffic control, operation control in mass transit
systems, life support, or
where the pertinent levels of safety are not guaranteed, or where a failure, an operational error, or some
other factor could be life-threatening or cause a physical injury (referred to below as "high-risk" use).
Customers considering the use of this product
measures in place beforehand. Moreover, they are requested to consult our sales representative before
embarking on such specialized use.
Security Export Control
Exportation/release of this document may require necessary procedures in accordance with the regulations
the Foreign Exchange and Foreign Trade Control Law of Japan and/or US export control laws.
of
a safe and convenient location for quick reference.
missile launch controls) where particularly high reliability requirements exist,
for high-risk applications must have safety-assurance
C120-0067-02ENi
Page 3
Preface
FCC Class B Notice
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1.This device may not cause harmful interference.
2.This device must accept any interference received, including interference that may cause undesired
operation.
This equipment has been tested and found to comply with the
Note
-
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions,
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try
interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/television technician for
FCC WARNING
could void the user's authority to operate the equipment.
Changes or modification not expressly approved by the party responsible for compliance
-
ICES-003 Class B Notice - Avis NMB-003, Classe B
CAN ICES-3 (B) / NMB-3 (B)
Korean Class B Notice
This equipment is home use electromagnetic wave suitability equipment and to be used mainly at home
and it can be used in all areas.
이기기는가정용전자파적합기기로서주로가정에서사용하는것을목적으로하며, 모든지역에서사용할수있습
.
니다
limits for a Class B digital device,
may cause harmful
to correct the
help.
Trademarks
-Oracle is a registered trademark of Oracle Corporation and/or its subsidiaries and affiliates in the
United States and other countries.
-SAMSUNG, PM1725a, and PM1725b are trademarks of SAMSUNG ELECTRONICS.
-Other company names and product names are the trademarks or registered trademarks of their
respective owners.
-Trademark indications (TM, (R)) are omitted for
This document shall not be reproduced or copied without the permission of Fujitsu Limited.
All Rights Reserved, Copyright (C) Fujitsu Limited 2018, 2019
some system and product names in this document.
Organization and Contents of This Manual
This document consists of the following chapters and appendixes.
Chapter 1 Overview
This chapter provides an overview of the Fujitsu 3.2 TB Flash Accelerator Card.
Oracle Solaris may be abbreviated as "OS" in this document.
■
Prompts in command examples
In command examples, the environment or privilege for the operation is distinguished by the
displayed prompt. The following table shows the relationship between prompts and environments/
privileges for operations.
PromptEnvironment/Privilege for Operation
{0} okOpenBoot PROM
XSCF>XSCF shell
$General user shell for OS
#Superuser shell for OS
Warning/Importance Indications
This manual uses the following indications to provide warnings and indicate useful information to the user
prevent personal injury and property damage.
to
C120-0067-02ENiii
Page 5
Preface
Warning – Indicates a hazardous situation that could result in death or injury if the product is not used
properly (a potentially dangerous situation).
Caution – Indicates a hazardous situation that could result in minor or moderate personal injury
and/or property damage, such as to the product itself or the user's property, if the product is not used
properly.
Warning Indications in the Text
Warning markings are followed by warning messages. A warning message is indented on the left and right
sides to distinguish it from regular text. Furthermore, the lines immediately before and after a warning
indication are left blank.
Ask a certified service engineer or our sales representative to perform the following tasks for this
product and the optional products provided by Fujitsu. The work must not be done by the customer
under any circumstances. Otherwise, electric shock, injury, or fire may result.
- New installation/relocation of the device
- Device
inspection/repair
Document Feedback
Please inform us of any comments or requests you may have about this document by contacting us at the
following URL with the manual number, manual title, page numbers, and specific details:
*1 The number/title of a changed chapter/section is the one in the latest version. However, the number/title
chapter/section with an asterisk is the one in the old version.
of a
Classification) (*1)
Whole manual (added/changed)Added "PM1725b" to types of flash cards
Appendix A (added)Added "A.9 Precaution on the nvmeadm list -s Command"
Description of Change
Changed card firmware version to "GPNA5B3Q" or "GPJA0B3Q"
C120-0067-02ENiv
Page 6
Product Handling Precautions
Product Handling Precautions
Maintenance
Ask a certified service engineer or our sales representative to perform the following tasks for this
product and the optional products provided by Fujitsu. The work must not be done by the customer
under any circumstances. Otherwise, electric shock, injury, or fire may result.
- New installation/relocation of the device
- Device
Modifying or Recycling the Product
inspection/repair
Modifying this product or recycling and using a secondhand product may result in personal injury to
users and/or bystanders or damage to the product and/or other property.
Disposal or Recycling of Products at the End of Their Life Cycles
Waste must be disposed of in a professional and responsible manner in accordance with environmental
regulations. For details, please contact your nearest environmental authority or our sales representative.
Replacement Work Personnel
Only certified service engineers should perform replacement work. The work must not be done by the
customer under any circumstances.
Otherwise, electric shock, injury, or fire may result.
For details on how to install the Fujitsu 3.2 TB Flash Accelerator Card, see "Maintaining the PCI Express
Cards" or "Maintaining PCIe Cards" in the following service manuals for the respective models of the
SPARC M12/SPARC M10 and the PCI expansion unit:
■
Fujitsu SPARC M12-1 Service Manual
■
Fujitsu SPARC M12-2/M12-2S Service Manual
■
Fujitsu M10-1/SPARC M10-1 Service Manual
■
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
■
PCI Expansion Unit for Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Service Manual
3.2 Optimizing the Fujitsu 3.2 TB Flash Accelerator Card
Chapter 3
This chapter describes how to configure the Fujitsu 3.2 TB Flash Accelerator Card.
Fujitsu 3.2 TB Flash Accelerator
Card Settings
3.1Checking the Fujitsu 3.2 TB Flash Accelerator
Card
You can check the Fujitsu 3.2 TB Flash Accelerator Card in the same way as detecting a hard disk drive.
The command shown below is an example.
# /usr/sbin/format
Searching for disks...done
AVAILABLE DISK SELECTIONS:
2.
Specify disk (enter its number):
:
c9t1d0 <SAMSUNG-MZPLL3T2HMLS-000-GPNA-2.91TB>
/pci@8300/pci@4/pci@0/pci@1/nvme@0/disk@1
/dev/chassis/SYS/PCI#2/NVME/disk
3.2Optimizing the Fujitsu 3.2 TB Flash Accelerator
Card
To obtain optimal performance, arrange all partitions to start on a 4 KB boundary.
In the following command example, the first sector of the partition is not aligned on a 4 KB boundary (1
sector = 512 bytes).
partition> print
Current partition table (original):
Total disk sectors available: 6251217517 + 16384 (reserved sectors)
3.3 Checking Various Information on the Fujitsu 3.2 TB Flash Accelerator Card
Number of Media Errors: 0x0
Number of Error Info Log Entries: 0x0
8
C120-0067-02EN
Page 19
Appendix A Precautions and Restrictions
A.5 Precaution on OS Boot From FCode
Appendix A
Precautions and Restrictions
A.1Restrictions on Oracle VM Server for SPARC
Do not use the following functions to assign the Fujitsu 3.2 TB Flash Accelerator Card to a guest domain.
■
Dynamic PCIe buses assignment function
■
Dynamic reconfiguration function for PCIe endpoint devices
■
Direct I/O function (function that assigns direct I/Os, DIOs, or PCle endpoints to domains)
A.2Restrictions on PHP/PPAR DR and Active
Replacement
Active replacement and active addition/removal with the PCI Hot Plug (PHP) and physical partition dynamic
reconfiguration (PPAR DR) functions cannot be used.
A.3Disk Label Precaution
Only the EFI disk label is supported because the size of the Fujitsu 3.2 TB Flash Accelerator Card is a disk
volume exceeding 2 TB.
A.4LBA Format Precaution
The Fujitsu 3.2 TB Flash Accelerator Card supports only LBA formats with a block size of 512 bytes.
A.5Precaution on OS Boot From FCode
On the SPARC M10, if you try to boot/reboot a logical domain after a certain amount of time has elapsed(*)
since physical partition (PPAR) power-on, the boot/reboot may fail.
This phenomenon does not occur on the SPARC M12.
9
C120-0067-02EN
Page 20
Appendix A Precautions and Restrictions
A.6 Precaution on Installing an OS on the Fujitsu 3.2 TB Flash Accelerator Card
The phrase "after a certain amount of time has elapsed" has the following meaning:
Note
-
(1) The 15-minute period after the elapse of "24 days, 20 hours, 16 minutes, and 23.648
seconds" (25th day) from physical partition (PPAR) power-on
(2) The 15-minute period after the elapse of above time (1) and
"24 days, 20 hours, 31 minutes, and 23.648 seconds" (50th day, 75th day, and so on)
the elapse of a multiple of time of
A.5.1Workaround
Apply XCP 2330 or later.
A.5.2Corrective Action After Occurrence
If the system does not stop at the ok prompt, apply break to the target domain to stop at an ok prompt. After
minutes have passed, execute the boot command again.
15
A.6Precaution on Installing an OS on the Fujitsu 3.2
TB Flash Accelerator Card
Installation of an OS on the Fujitsu 3.2 TB Flash Accelerator Card may cause the following message to be
output, and the card may not appear as an OS possible installation destination.
WARNING: Fail to attach: 8192 page size is not supported by the controller.
A.6.1Workaround
To install an OS on the Fujitsu 3.2 TB Flash Accelerator Card, use an OS installation image with Oracle
Solaris 11.3 SRU 28.4 or later already applied.
You can create the OS installation image by using distro_const.
For details on creating a custom Oracle Solaris 11 installation image for Oracle Solaris 11.3,
Creating a Custom Oracle Solaris 11.3 Installation Image
A.6.2Corrective Action After Occurrence
None
.
see the
10
C120-0067-02EN
Page 21
Appendix A Precautions and Restrictions
A.9 Precaution on the nvmeadm list -s Command
A.7Precaution on the nvmeadm namespace -v
Command
Not "1" but rather "32" appears as the namespace ID.
# nvmeadm namespace -v
SUNW-NVME-1-NAMESPACE-1
#
Namespace: 32
Block Size: 512
Capacity: 3200631791616
Metadata Size: 0
Block Device Name: /dev/rdsk/c11t1d0s2
Status: online
Nac Name: /dev/chassis/SYS/PCI#2/NVME/disk
A.8Restriction on the -n Option of the nvmeadm
Command
When specifying each namespace individually with the nvmeadm namespace, online, or other command,
specify and execute the -a option + namespace, not the -n option + namespace ID.
The following example shows execution of nvmeadm online.
# nvmeadm online -a SUNW-NVME-1-NAMESPACE-1
A.9Precaution on the nvmeadm list -s Command
The command displays incorrect PCIe IDs.
# nvmeadm list -s
SUNW-NVME-1
#
PCI Vendor ID:
PCI Device ID:
PCI Subsystem Vendor ID:
PCI Subsystem ID:
Oracle Part Number:
Oracle Model Number:
0x3052
0x3130
0x0405
0x1620
11
C120-0067-02EN
Page 22
Appendix A Precautions and Restrictions
A.11 fwupdate Command Precaution
The actual PCIe IDs are as follows.
PCI Vendor ID:
PCI Device ID:
PCI Subsystem Vendor ID:
PCI Subsystem ID:
0x144d
0xa822
0x144d
0xa814
A.10Restriction on probe-nvme-all
The probe-nvme-all command cannot be used.
To confirm that the Fujitsu 3.2 TB Flash Accelerator Card is recognized on the OpenBoot PROM
environment, use the show-devs command.
A.11fwupdate Command Precaution
The fwupdate list controller command does not display "NVMe" but rather "SAS" for Type. The command
shown below is an example.
Appendix B Specifications
B.6 Reliability Specifications
Table B-5 Performance Specifications (continued)
ItemSpecifications
Quality of serviceRead/Write (99%): 160/100 µs
Performance consistencyRead/Write (99.9%): 98/84%
B.6Reliability Specifications
Table B-6 Reliability Specifications
ItemSpecifications
17
Uncorrectable bit error rate1 sector per 10
MTBF2,000,000 hours
Life5 years
Endurance5 DWPD
Data retention period3 months
Data protection at power
outage
Available
bits read
15
C120-0067-02EN
Page 26
Appendix C Environmental Information
C.1 Taiwan RoHS Declarations
Appendix C
Environmental Information
C.1Taiwan RoHS Declarations
Table C-1 Taiwan RoHS Declarations
設備名稱:固態硬碟, 型號(型式):
Equipment name
Restricted substances and its chemical symbols
單元
Unit
電子零組件
Component
電路板
PCB
錫膏
Solder Paste
主動及被動零
組件
Passive &
Active Device
次要零組件
Subsidiary parts
備考1. 〝超出
Note 1: "Exceeding 0.1 wt %" and "exceeding 0.01 wt %" indicate that the percentage content of the restricted
substance exceeds the reference percentage value of presence condition.
備考2. 〝○〞係指該項限用物質之百分比含量未超出百分比含量基準值。
Note 2: "○" indicates that the percentage content of the
reference value of presence.
備考3. 〝-〞係指該項限用物質為排除項目。
Note 3: The "-" indicated that the restricted substance corresponds to the exemption.
0.1 wt %
鉛
Lead
(Pb)
○○○○○ ○
○○○○○ ○
○○○○○ ○
-○○○○ ○
○○○○○ ○
〞及〝超出
汞
Mercury
(Hg)
0.01 wt %
〞係指限用物質之百分比含量超出百分比含量基準值。
Type designation (Type)
限用物質及其化學符號
鎘
Cadmium
(Cd)
restricted substance does not exceed the percentage of
3.2TB Flash Accelerator Card
六價鉻
Hexavalent
chromium
(Cr+6)
多溴聯苯
Polybrominated
biphenyls
(PBB)
多溴二苯
Polybrominated
diphenyl ethers
醚
(PBDE)
16
C120-0067-02EN
Page 27
Appendix C Environmental Information
C.3 For Indian e-waste Rules
C.2China RoHS Declarations
该标
志是不是按照国际惯例
限制性使用不当管理办法办法]以及
国销售的电器电子产品环保使用期限的标识。常遵守关于该产品的安全及使用上的注意事
该
期限内(从生产日期起算不了
境污染以及对岸人体或
财产产
报
2016
年
SJ/T11364[
该产
)
品不会因产品中的有害物质泄露或突然发生的异
生重大影响。
报
1
21
月
日报公布于的确
电子电气产
电器电子产
[
品有害物质限制使用标识要求]在案中
品有害无益物质财富
变
,
而引起
Table C-2 China RoHS Declarations
有毒有害物质或元素
铬
铅
部件名称
元器件
Component
印刷电路板
PCB
锡
膏
Solder Paste
主被动元器件
Passive &
Active Device
附属品
Subsidiary parts
○: 表示该有毒有害物质在该部件所有均质在该部件所有均质材料中的含量均在
Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is below the
relevant threshold of the GB/T26572.
×:
表示该有毒有害物质至少在该部件的某一均质材料中的含量超出
Indicates that the concentration of the hazardous substance of at least
above the relevant threshold of the GB/T26572.
Lead
(Pb)
○○○○○ ○
○○○○○ ○
○○○○○ ○
×
○○○○○ ○
汞
Mercury
(Hg)
○○○○ ○
镉
Cadmium
(Cd)
六价
Hexavalent
chromium
(Cr6+)
GB/26572
GB/26572
规
定的限量要求。
one of all homogeneous materials in the parts is
多溴联苯
Polybrominated
biphenyls
(PBB)
规
定的限量要求以下。
多溴二苯
Polybrominated
diphenyl ethers
(PBDE)
项
醚
,
在
环
C.3For Indian e-waste Rules
■
This product does not contain 6 hazardous substances in accordance with article 16(1) in "The
e-waste (Management) Rules, 2016."
■
This symbol means that used electrical and electronic products should not be dropped in garbage bin
containing waste destined for disposal. Please dispose of this product appropriately by handling over
authorized collection center or registered dismantler or recycler. Disposing correctly will help to
to
protect human health and the environment.
17
C120-0067-02EN
Page 28
Appendix C Environmental Information
C.3 For Indian e-waste Rules
18
C120-0067-02EN
Page 29
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.