Standard Features
Optional Wired Remote
p Weekly Timer p Full Function Wired Remote p Child Lock Capable
UTY-RNBYU
l Wireless Remote Control l Sleep Timer l Coil Dry Mode
l
Dry Mode
l
Auto Louver: 4-Way
l
Auto Mode
l
Quiet Mode
Wall Mounted 9 and 12,000 BTU Systems
SYSTEMS 9R2, 12R2
Up to 14.3-SEER
l Economy Mode l Auto Restart/Reset l Auto Changeover
l
Low Ambient
l
Cold Prevention
l
Minimum Heat
l
Basic Third Party Interface*
Stylish, slim and elegant, these popular wall mounted units are designed for single rooms. Indoor units have a clean, aesthetic design and are small but mighty and shorter in length than competing units, helping them blend into any room. 13 and 14-SEER heat pump systems have over a 30% increase in efficiency over conventional 10-SEER models and feature environmentally friendly R410A refrigerant, both heating and cooling operation, quiet mode and easy maintenance.
Function
Applications
This category of equipment is ideal for smaller spaces where spot cooling or heating is required. Residential applications including sunrooms and additions are made easier with these 115 volt air conditioners and heat pumps. Do you have a warm or cool spot in your home? Our mini-splits can provide extra cooling or heating capacity for those hard to cool areas. Commercially, their small size makes them ideal for small offices, providing individual temperature control.
FRONT & SIDES OF AOU9R2, AOU12R2
FRONT & SIDES OF ASU9R2, ASU12R2
Indoor
ASU9R2
Outdoor
AOU9R2
Indoor
ASU12R2
Outdoor
AOU12R2
FOR MORE INFORMATION:
Note: Figures are based on 115 Volts.
FUJITSU GENERAL AMERICA, INC.
353 Route 46 West Fairfield, NJ 07004
Tel: (973) 575-0380 Fax: (973) 836-0448
www.fujitsugeneral.com
Rev. 11/10
The Fujitsu logo is a registered trademark of Fujitsu Limited. The Halcyon logo and name is a trademark of Fujitsu General America, Inc. Copyright 2010 Fujitsu General America, Inc.
Fujitsu’s products are subject to continuous improvements.  Fujitsu reserves the right to modify product design, specifications and information without notice and without incurring any obligations.
31-1/8
10-13/16
8-7/16
11-1/2
11-5/16
2-3/16
31-1/8
11/16
21-3/8
14
Easy Maintenance
Front panel is easily removed for cleaning.
9R2
Heat Pump
12R2
Heat Pump
9,700 12,300
9,600 12,800
8.2
14.3
8.2
13.7
11.8/13.9 11.5/12.9
32~115 (0~46)
17~75 (-8~24)
2.1 (1.0)
32~115 (0~46)
17~75 (-8~24)
3.2 (1.5)
115/60/1 115/60/1
15 20
324 (550) 383 (650)
271 (460) 324 (550)
241 (410) 265 (450)
200 (340) 206 (350)
40/38 45/42
36/34 40/37
31/29 34/32
26/25 29/27
640 770
43/45 (Clg/Htg) 45/46 (Clg/Htg)
7.6 9.9
6.5 9.2
0.82 1.07
0.69 0.99
4 + Auto 4 + Auto
Manual Manual
Automatic Automatic
Washable Washable
Flare Flare
49 (15) 49 (15)
26 (8) 26 (8)
Suc. 3/8 Dis. 1/4 Suc. 3/8 Dis. 1/4
21 (9.5) 71 (32) 21 (9.5) 79 (36)
10-13/16
21-3/8
10-13/16
21-3/8
275 540 275 540
31-1/8 31-1/8 31-1/8 31-1/8
790 790 790 790
8-1/2 11-1/2 8-1/2 11-1/2
215 290 215 290
R410A R410A
Nominal Cooling BTU/h
Nominal Heating BTU/h
HSPF BTU/hW
SEER BTU/hW
EER Clg/Htg
Clg. Operating Range °F(°C)
Htg. Operating Range °F(°C)
Moisture Removal
Pt./h(l/h)
Voltage/Frequency/Phase
Recommended Fuse Size
(A)
Air Circ. C.F.M. (m
3
/h): Hi
Medium
Low
Quiet
Noise Level
dB(A): Hi
Medium
Low
Quiet
Outdoor Fan Speed
RPM
Outdoor Noise Level dB(A)
Current (A): Cooling
Heating
Power Use
(kw): Cooling
Heating
Fan Speeds Stage
Air Direction: Horizontal
Vertical
Air Filter
Connection Method
Combined Max. Lgth
Ft (m)
Max. Vertical Diff. Ft (m)
Conn. Pipe Diameter Inch
Net Weight lbs. (kg)
Dimensions: Height Inch
mm
Width Inch
mm
Depth Inch
mm
Refrigerant
Loading...