IMPORTANT
Must use this wiring diagram for installation. Do not use Thermador wiring diagram.
WARNING
Electrical wiring should be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. An unqualified person doing the work could result in fire, electric shock or injury.
This switch uses 120 V AC, Max 16 Amp. Do not connect to other voltage or over current rate since fire, electric shock or damage could result.
Be sure to switch power OFF at service panel before wiring.
< CONNECTING POWER SUPPLY WIRES >
A 2-1/2" deep Wall Box must be used to allow space for
1. wire connections between switch and 120 volt Power Input Leads.
Switch: Red
Switch: Yellow
Switch: Black
High speed
BLACK /120V AC
Low speed
WS06
Top
Blue
No Use
Neutral
Red
Ground
GE Switch: ASR-4173-500 (UL Recognized Component)
OFF
WHITE /NEUTRAL
Black
LO
MED
HI
Switch: Blue Medium speed
2.
Connect the electrical wires in accordance with wiring diagram (figure 1). Connect wires tightly and securely using wire connectors (not supplied).
3.
Attach the wall plate, and secure with 2 screws.
Turn on the electrical circuit to the power unit. Check
4. the ventilating functions at each speed control positions. Make sure that the range hood has no abnormal noises and/or vibration.
Your installation is now complete. If you should require service or replacement parts on your ventilation system. contact:
Fuji Industrial USA,Inc.
16300 Christensen Rd, #212 Seattle, WA 98188
1-888-547-9880
READ AND SAVE THESE INSTRUCTIONS.
Keep this manual in a convenient place for future reference.
FIG 1
< Connection Diagram >
2-1/2" Deep Wall Box (must be grounded)
Bowers #52 or Equivalent
FIG 2
From Blower Moter
Motor Green or Bare Ground Wire
- Grounded to Wall Box