Ultrasonic Flowmeter for Air
Type: FWD
Ideal for proper management for compressor etc…!
Abundant applicable pipe diameters
Applicable pipe diameter 25mm up to 200mm.
No energy loss due to no pressure loss
Measurement principle is ultrasonic method. There is no pressure loss without protrusion in the pipe.
No need of filter such as mist separator thanks to FWD has high resistance to oil mist
Accurate flow rate measurement including oil mist. Strong durable and reliable to use.
No need of power source installation work by means of battery driven
Lithium-battery build-in type (approx. 10 years operating) is provided without painful wiring work of the power.
Flow rate conversion available
Conversion from an actual flow rate to a flow rate at normal conditions (0°C, 1 atm) or user-defined conditions.
Capable of forward/reverse measurement and output
Nominal diameter
25 and 32mm
Nominal diameter
40 to 80mm
Nominal diameter
100 to 200mm
21A1-E-0019a
Airflow rate measurement supported by ultrasonic method!
"Visualization" is supported meeting customer's demands.
Nominal diameter 25 and 32mm
(screwed type)
Nominal diameter 40, 50, 65 and 80mm
wafer connection type)
(
Features
No energy loss due to no pressure loss.
Ultrasonic method is adopted as a measurement principle.
n
There is no pressure loss due to no protrusion in a pipe.
n
High durability thanks to it has strong resistance to oil
and mist.
Strong structure to oil ,mist and fluid containing dust due to no moving parts.
n
Capable of using even with old pipe and refueling type compressor.
n
Note) In case of a large amount of oil and mist contained, a vertical piping is
recommended to use.
Capable of forward/reverse measurement and output.
Capable of forward/reverse measurement and output according to
n
measurement setting.
Comprehending an using air rate where flows between factories, also
n
applicable to loop pipe.
Abundant output functions enables a system
management/control.
Not only unit pulse but also 4 to 20mA DC analog output and upper /lower
n
alarm output are provided.
Note) When 4 to 20mA DC analog output is selected, instantaneous flow rate,
pressure and temperature can be switched in the field.
Capable of detecting the air leakage.
Nominal diameter 100,150, and 200mm
(flange connection type)
No need of power source installation work by means
of battery driven.
Build-in battery type (10 years operating) is also provided which
n
eliminates painful power source installation work.
Note) Battery driven type is to indicate only.
1: 60 Wide range ability
Having wide range ability enables little amount of flow rate to be
n
measured accurately.
Furthermore, it realize that wide rage with 1:400 from sensitive flow rate
(beginning of the measuring flow rate) to maximum flow rate.
Easy to read display
LCD digital display with large size of characters allows to read easily and
n
capable of reading an accumulated flow rate and instantaneous flow rate
simultaneously.
Additionally, indication part can be rotated in 90 degrees in the field.
Display
Measurement error indicator
Flow rate type
Select among
Normal/Standard/
Blank (actual flow rate)
Blinker
tells you that flow is
detected
Flowmeter life indicator (for battery-powered type only)
Communication error
indicator
Gas type (Air or N2)
Main display:
Accumulated flow rate
Sub display:
Instantaneous flow rate
Principle
Excellent repeatability "Transit Time" Method.
Two ultrasonic sensors are installed on the side of flow entrance
and exit for flow meter.
When liquid flows in the direction of the arrow as shown on the
diagram, difference of transit time by flow velocity occurs between
sound waves generated from flow entrance and exit.
This time lag is using for detecting the flow velocity of the fluid and
calculating the volumetric flow according to cross-section area of the
flow meter and flow velocity.
Furthermore, capable of converting a flow rate into the one at
normal or standard conditions by means of built-in pressure sensor.