Fuji Electric FSV Specifications

SERIES
ULTRASONIC FLOWMETER
<
DATA SHEET
This owmeter is a clamp-on type ultrasonic ow meter based on transit-time measuring method. Making full use of the latest electronics and digital signal processing technologies, we realized a compact and light­weight design, and improved the accuracy and easiness to use while keeping with anti-bubble performance. The communication function (MODBUS: Option) is also applicable.

FEATURES

The owmeter is designed for high accurary (better than ±1.0% of rate) by dynamic correction of fully-developed ow prole. Reynolds Number is calculated and a meter factor (K) is automatically applied for best accuracy at all ow velocities. Further, the adoption of new sound velocity measurement system permits measurements of uids of unknown sound velocity. Moreover, affection from uid temperature and pressure is negligible (Auto-Temp./ Press. compensation).
2.Excellentresistanceagainstaeratedow
Fuji’s unique ABM feature improves measurement reli­ability for different ow like slurries, sludge, raw sewage and bubble-contained ow (acceptable up to air bubble of 12% volume at 1m/s velocity).
3.Compactandlight-weight
Thanks to the adoption of the latest electronics the ow transmitter size and mass are 1/3 of our traditional in­strument.
4.Fullvarietyofsensors
The owmeter can be used with various types of sensors applicable for wide range of pipe size (ø13 to ø6000mm) and uid temperature (-40 to +200°C).
5.Quickresponse
With the use of high-speed micro-processor suited for digital signal processing, the fast response time is realized.
6.Multi-lingual
The following languages are supported for display: Japanes e (Katakana), English, German French, and Spanish.
7.Excellentperformanceandeasyoperation
LCD and function keys are allowing easy conguration and trouble shooting.
− LCD with back light
− Easy mounting of sensor
− Extendable rail type detector up to ø50 to ø1200mm
− Trouble shooting
− Easy operation with keypad on the front surface of the ow transmitter (FSV···S)
Flow transmitter
(FSV···S)
Detector (FSSA)
Detector (FSSC)

SPECIFICATIONS

Operationalspecications
Systemconguration:
Single-path system of a ow transmitter
(Model FSV) and a detector (Model FSS)
Applicabledetector:
FSSA (2MHz), FSSC (1MHz)
Applicableuid:
Homogenous liquid where the ultrasonic
signal can be transmitted
Bubble quantity: 0 to 12vol% (for pipe size
50A, water, velocity 1m/s) Fluid turbidity: 10000mg/L max. Type of ow: Fully-developed turbulent or
laminar ow in a full-lled pipe
Flow velocityrange:
0 to ±0.3 ... ±32m/s
>
FSV-2, FSS, FLY
Flow transmitter
(FSV···H)
EDSX6-142g
Feb. 26, 2018Date
FSV-2, FSS, FLY
Powersupply: 100 to 240V AC +10%/-15%, 50/60Hz;
or 20 to 30V DC
Signalcable(betweendetectorandconverter):
Coaxial cable (150m max.) applicable up
to 300m depending on the condition.
Heat resistance: 80°C
Installationenvironment:
Non-explosive area without direct sunlight,
corrosive gas and heat radiation.
Ambienttemperature:
Flow transmitter: -20 to +55°C Detector: -20 to +60°C
Ambienthumidity:
Flow transmitter: 95%RH max. Detector: 90%RH max. Grounding: Class D (100 Ω) Arrester: Provided as standard at power supply Applicablepipinganduidtemperature: <table 1>
Detector Pipe size
(Inner diam­eter) ø mm
25 to 50 Plastic (PVC, Others)
FSSA
50 to 225 Plastic (PVC, Others)
50 to 600 V method
FSSC
200 to 1200 Z method
Note1) Please select the FSSC type if following condition.
• When pipe material is PP or PVDF, limit of pipe wall thick­ness is 15mm or more for PP, 9mm or more for PVDF
• When pipe material is hard to penetrate the ultrasonic wave such as cast-iron pipe, lining pipe and old carbon steel pipe etc..,
• Llining material is tar epoxy, mortar and rubber etc..
• In case lining is removed from the pipe, Measurement
Note2) When silicon grease is used as acoustic coupler, Fluid tem-
Note3) Heat-resistant shock temperature: for 30 minutes at 150°C Note4) Please refer to the item 9 for the specication of the special
Note5) For pipes with a diameter of 300 mm or larger, we recom-
can not be conducted
perature limit is 0 to 60°C no matter what detector is selected.
detector (for small diameter pipe,large diameter pipe and high temperature)
mend to use FSSE and mount it by Z method.
Appl icabl e pi pe materi al (Note1)
Metal pipe (Stainless steel, Carbon steel, Copper, Alu­minum, Others)
How to mount
V method -20 to +100
Flued temperatur range (°C) (Note2, 3)
-40 to +120
Digitaloutput: Forward total, reverse total, alarm,
acting range, ow switch, total switch assignable arbitrarily
Transistor contact (isolated, open collector)
• Outputs: 2 points
• Normal: ON/OFF selectable
• Contact capacity: 30V DC, 50mA
• Output frequency: 1000P/s max. (pulse width: 5, 10, 50, 100, 200, 500, 1000ms)
Serialcommunication(option):
RS-485 (MO DB US ), isolated, arrester
incorporated Connectable quantity: 31 units Baud rate: 9600, 19200, 38400bps Parity: None/Odd/Even selectable Stop bits: 1 or 2 bits selectable Cable length: 1km max. Data: Flow velocity, ow rate, forward
total, reverse total, status, etc. Displaydevice: 2-color LED (Normal: green, Extraordi-
nary: red) LCD with 2 lines of 16 characters and
back light
Indicationlanguage:
Japa nese (Katakana)/En glish /French/
German/Spanish (changeable)
Flow velocity/owrateindication:
Instantaneous ow velocity, instantaneous
ow rate indication (minus indication for
reverse ow) Numerals: 8 digits (decimal point is counted
as 1 digit) Unit: Metric/Inch system selectable
Metric system Inch system
Velocity m/s ft/s
Flow rate L/s, L/min, L/h, L/d, kL/d,
Note: The ”gal” means USgal.
3
ML/d, m km BBL/min, B BL/h, B BL/d, kBBL/d, MBBL/d
/s, m3/min, m3/d,
3
/d, M m3/d, B B L / s ,
gal/s, gal/min, gal/h, gal/d, kgal/ d, Mgal/d, ft
3
min, ft
/d, Kft3/d, Mft3/d, BBL /s, BBL/ min, BBL/h, BBL/d, kBBL/d, MBBL/d
3
/s, ft3/
Performancespecications
Rated accuracy: <table 2>
Detector Type
FSSA
FSSC
Note1) Please refer to the item 9 for the specication of the special
Pipe size (diameter) mm
ø25 to ø50
ø50 to ø225
ø50 to ø200
ø200 to ø1200
detector (for small diameter pipe, large diameter pipe and high temperature)
Flow velocity (m/s)
2 to 32 ±2.0% of rate –
0 to 2 ±0.04m/s
2 to 32 ±1.0% of rate ±2.0% of rate
0 to 2 ±0.02m/s ±0.04m/s
2 to 32 ±1.5% of rate
0 to 2 ±0.03m/s
2 to 32 ±1.0% of rate
0 to 2 ±0.02m/s
Accuracy
Plastic pipe Metal pipe
Responsetime: 1s (standard mode)
0.2s as selected (quic
k response mode)
Powerconsumption:
15VA max. (AC power supply) 6W max. (DC power supply)
Functionalspecications
Analogsignal: 4 to 20mA DC (1 point)
Load resistance: 600Ω max.
2
Totalindication:Forward or reverse total value indica-
tion (negative indication for reverse direction)
Numerals: 8 digits (decimal point is counted
as 1 digit)
Unit: Metric/Inch system selectable
Metric system Inch system
Total mL , L, m
mBBL, BBL, KBBL
3
, k m3, M m3,
ga l, k ga l , ft3, kft3, Mft3, mBBL, BBL, kBBL, ACRE-ft
Conguration: Fully congurable from the 4-key pad
(ESC,
, , ENT)
Zero adjustment:Set zero/Clear available Damping: 0 to 100s (every 0.1s) for analog output
and ow velocity/ow rate indication
Lowow ratecutoff:
0 to 5m/s in terms of ow velocity Alarm: Digital output available for Hardware
fault or Process fault
Burnout: Analog output: Hold/Overscale/Under-
scale/Zero selectable Flow rate total: Hold/Count selectable Burnout timer: 0 to 100s (every 1s)
Bi-directionalrange:
Forward and reverse ranges congurable
independently. Hysteresis: 0 to 10% of working range Working range applicable to digital output Auto-2range: 2 forward ranges congurable indepen-
dently Hysteresis: 0 to 10% of working range Working range applicable to digital output Flow switch: Lower limit, upper limit congurable
independently Digital output available for status at actu-
ated point Totalswitch: Forward total switching point congurable Digital output available when actuated
Externaltotalpreset:
Preset total settable upon contact input
setting
Backupofpower failure:
backup by non-volatile memory
Physicalspecications
Type of enclosure:
Flow transmitter: FSV···S: IP66 FSV···H: IP67 (With large LCD) Detector:
FSSA, FSSC:
IP65 (When waterproot BNC con-
nector is provided) FSSA,FSSC: IP65 (When water-proof type con-
nector is tting) FSSC (waterproong): IP68 (submerged resistant structure
for 5days)
Mountingmethod:
Flow transmitter: Mounted on wall or by
2B pipe
Detector: Clamped on pipe surface
Acousticcoupler:
Acoustic coupler is a lling between detec-
tor and pipe.
Type of acoustic coupler: <table 3>
Grease for high temperature (KS62M)
Type
Fluid temperature
Teon piping
Silicone rubber (KE-348W)
-40 to +150°C -30 to +150°C 0 to +60°C -30 to +250°C
Silicone grease (G40M)
Silicone-free grease (HIGH Z)
In case of Teon piping, use grease.
Material: Flow transmitter: Aluminum alloy Detector: <table 4>
Detector Type Sensor housing Guide rail
FSSA PBT SUS304
FSSC PBT Aluminum alloy
Please refer to the item 9 for the specication of the special detector
*
(for small diameter pipe, large diameter pipe and high temperature)
Signalcable: • Structure: Heat-resisting high-frequen-
cy coaxial cable
• Sheath: Flame-resisting PVC
• Outer diameter: ø7.3mm
Terminal treatment <table 5>
Cable type FLYD
Applicable detector FSSA, FSSC
Terminal of ow transmitter side
Terminal of detector side
Please refer to the item 9 for the specication of the special detector
*
(for small diameter pipe, large diameter pipe and high temperature)
Rod terminal ×2 Amplier terminal (M3) ×1
BNC connector × 1 Amplier terminal (M4) ×1
Dimension, Mass: <table 6>
Type Dimensions Mass.(kg)
Flow
transmitter
Detctor
Signal cable FLYD ø7.3mm 90g/m
Please refer to the item 9 for the specication of the special detector
*
(for small diameter pipe, large diameter pipe and high temperature)
FSV···S (IP66) H170 × W142 × D70mm 1.5
FSV···H (IP67) H277 × W244 × D96mm 4.5
FSSA H50 × W348 × D34mm 0.4
FSSC H88 × W480 × D53mm 1
Externalterminalofowtransmitter:
plug terminal
EUDirectiveCompliance
LVD(2014/35/EU)
EN 61010-1
EMC(2014/30/EU)
EN 61326-1 (Table 2) EN 55011 (Group 1 Class A) EN 61000-3-2 (Class A) EN 61000-3-3 EN 61326-2-3
RoHS (2011/65/EU)
EN 50581
PCLoadersoftware
Provided as standard
•Compatible model is PC/AT compatible instrument.
•Main functions: Software for Main unit parameter setting/ change on PC
•OS: Windows 2000/XP/Windows 7 (Home Premium, Profes-
sional) or Windows 8 (Professional)
•Memory requirement: 125MB min.
•Disk unit: CD-ROM drive compatible with Windows 2000/
XP/Windows 7 (Home Premium, Professional) or Windows 8 (Professional)
•Hard disk capacity: Minimum vacant cap acity of 52MB
or more
Note: Optional communication board (specied at the 5
digit of code symbols).
Note: Communication converter
For tne PC that supports RS-232C serial interface, RS-232C - RS-485 converter is needed for connecting the PC and main unit. For the PC that does not support RS-232C serial interface, additionally, USB - RS232C converter is also needed.
<Recommendation>
[RS-232C - RS-485 converter] RC-770X(manufactured by SYSMEX RA)
[USB - RS-232C converter] USB-CVRS9 (manufactured by SANWA SUPPLY)
th
3
FSV-2, FSS, FLY

MEASURING PRINCIPLE

With ultrasonic pulses propagated diagonally between the upstream and downstream sensors, ow rate is measured by detecting the time difference obtained by the ow of uid.
Detector
Upstream sensor
θ
Flow velocity
Downstream sensor
t
2
t
1
D
Output signal
Flow transmitter

MOUNTING OF DETECTOR

Ultra sonic oscillator
Plastic wedge
Pipe
Lining

CONFIGURATION DIAGRAM

(1)Single-pathsystem(Vmethod)
Signal Cable
Detector
Flow transmitter
(2)Singlepath system(Zmethod)
Signal Cable
Detector
Flow transmitter
DC 4 to 20mA
Digital signal (Up to 2 point)
DC 4 to 20mA
Digital signal (Up to 2 point)
Conditionsonstraightpipe
( D : Inside diameter of pipe)
Classification Upstream side Downstream side
L 5D
1.5D
L 10D
Detector
L 50D
L 30D
D
L 10D
L 10D
L 5D
L 50D
90 bend
Tee
Diffuser
Reducer
10D or more
10D or more
0.5D or more
10D or more
Various Valve
Pump
(Note) The source : JEMIS-032
4
L 30D
In case that flow control valve exists on upstream side.
Stop valve
Check valve
P
L 10D
In case that flow control valve exists on downstream side.
L 50D
Loading...