Fuego Pro-s, Pro-c User Manual

FPANG1: LP TO NG CONVERSION KIT INSTRUCTION MANUAL
Models PRO-C & PRO-S
FPANG1 includes the following components: 1 - 10 foot 3/8” ID gas hose with quick connect 1 - 1.80mm natural gas orifice for Outer Burner 1 - 1.24mm natural gas orifice for Inner Burner
Connection: Operating pressure: 7.0” W.C.
Assembly Instructions:
A. Assemble as shown above (FIG. 01). Remove
the front door. Use a pipe wrench to hold the grill inlet pipe to avoid shifting any internal gas lines of the grill. Remove the pre-attached LP gas hose pipe from the inlet fitting of the grill. Attach the 3/8" ID gas hose on.
B. Assemble as shown above (FIG. 02) Use
screwdriver to remove screws holding burner to grill body by unscrewing counter-clockwise to remove the burner kit.
C. Use a wrench to unscrew the LP gas orifice by
turning counter-clockwise and replace with natural gas orifice. Use the 1.80mm orifice (Silver) for the Outer Burner ring and the
1.24mm orifice (Brass) for the Inner Burner ring. Note: The natural gas orifice has a larger hole in the center to keep the flow of natural gas consistent.
D. After the replacement, properly locate and re
attach the burner kit with respect to the orifices. Adjust the igniter tip located near the burner edge. (FIG. 03)
(Brass) ORIFICE 1.24MM FOR INNER BURNER
(Brass) ORIFICE 1.80MM FOR OUTER BURNER
(Brass) ORIFICE 1.80MM FOR OUTER BURNER
(Brass) ORIFICE 1.24MM FOR INNER BURNER
FIG 01.
FIG 02.
FIG 03.
Fuego Living LLC 147 Standard St El Segundo CA 90245 888-88-FUEGO info@fuegoliving.com
NOTE: Do not use natural gas orifices with an LP gas tank or LP gas orifices with natural gas. Do gas leakage testing after per conversion. Please note the Gas Hook-Up, Danger, and Warnings pages in the manual for more information.
E. Connect the NG hose assembly to fixed NG
piping system. (FIG. 04) Turn on gas supply and do the leak testing as the procedures shown on page 26 of main manual. Read all lighting instructions on main manual prior to lighting.
F. Remove the control knob, knob bezel and
control valve. FIG 05.
G. Turn the valve adjusting screw counter
clockwise 100%. FIG 06.
H. Re-install the control knob bezel, valve and
knob using the same Phillips head screws. FIG 07.
I. After the conversion is done, apply the rating
plate on the unit.
1. The outdoor cooking gas appliance and its individual shutoff valve must be disconnected from the gas supply system during any pressure testing of that system at test pressures in excess of
0.5psi(3.5kpa)
2. The outdoor cooking gas appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than
0.5psi(3.5kpa).
FIG 04.
FIG 05.
FIG 06.
FIG 07.
Loading...