FTI LBRA-10 Operation, Maintenance, And Repair Manual

401 Andover Park East
USA (206) 246-2010
UNCONTROLLED IF PRINTED
Seattle, Washington 98188-7605
FTI OPERATIONS, MAINTENANCE, AND REPAIR MANUAL
Little Brute Right Angle Puller (LBRA-10)
Part #2720-126, Log #36511
Original, March 30, 2018
NO REVISIONS WILL BE ISSUED
This manual should be used in conjunction with the FTI
“Little Brute Puller Unit Operations, Maintenance, and Repair Manual”
© Copyright 2018
Fatigue Technology
es
erved
UNCONTROLLED I
F PRINTED
ABOUT FATIGUE TECHNOLOGY
Fatigue Technology (FTI) is a world-leading aerospace engineering and manufacturing company. FTI pioneered cold expansion technology (which provides solutions to fatigue problems associated with holes in metal structures) back in 1969 and has advanced this science to develop innovative bushing and fastener products. These proprietary products and associated tooling may be covered by patents or agreements owned by or exclusively licensed to Fatigue Technology. Use of tooling procured from other than a licensed source may constitute patent infringement.
The detailed tooling information in this manual was compiled and written by FTI. The tooling was designed specifically for use with FTI’s Cold Expansion (Cx™) Systems. FTI cannot be held responsible for damage or injury as a result of operating this equipment if it is used for other than the process intended, with any other tooling not provided by FTI, or not used in accordance with the instructions contained in this manual. To avoid personal injury, please observe all safety precautions and instructions. FTI reserves the right to change specifications or configurations of equipment detailed in this manual as part of our ongoing technical and product improvement programs. If you have any questions about the use or serviceability of this equipment, please contact our Sales Department.
FTI’s systems and processes are the subject matter of one or more of the following patents: 4,809,420, 4,885,829, 4,934,170, 5,083,363, 5,096,349, 5,103,548, 5,127,254, 5,129,253, 5,218,854, 5,245,743, 5,305,627, 5,341,559, 5,380,136, 5,405,228, 5,433,100, 5,468,104, 6,077,010, 6,183,180, 6,487,767, 6,792,657, 6,990,722, 7,024,908, 7,100,264; 1,061,276, 513,898, 692015124, 581,385, 69310828, 468,598, 69105390, 643,231, 69414946, 696,686, 785,366, 1032769, and other patents pending. These systems and processes are tooling critical and must be performed in accordance with FTI’s specifications or controlling documents. To ensure proper results from FTI’s cold expansion systems and to be licensed to use FTI’s patented processes, it is essential that FTI’s complete integrated system of tooling be purchased and utilized. The use of tooling purchased from other than a licensed supplier could jeopardize fatigue life enhancement and may constitute patent infringement.
Fatigue Technology Inc. 401 Andover Park East Seattle, WA • USA 98188-7605 Tel: (206)246-2010 Fax: (206)244-9886 796945
ONTROLLED IF PRINTED
UNC
FTI reserves the right to change the specifications or configurations of tooling detailed in this manual as part of its ongoing technical and product information program. Should inconsistencies occur between your tooling and this manual, please contact our Sales Department.
atigue Technology (FTI) has provided innovative solutions to fatigue problems in metal structures since 1969. Complete
F systems of tooling are used worldwide to enhance the fatigue life of holes in airframes, turbine engines, and other critical structures.
T
he FTI staff of professionals provides a full range of support services including:
pplication engineering
A
D
etailed project planning, implementation, and management
On-s
T
he Sales Department is always available to assist with special fatigue enhancement requirements. Please contact FTI with
ite assistance, including training and tool room setup
questions at any time.
Fatigue Technology Inc. 401 Andover Park East Seattle, WA • USA 98188-7605 Tel: (206)246-2010 Fax: (206)244-9886 796945
UNCONTROLLED IF PRINTED
TABLE OF CONTENTS
SECTION DESCRIPTION PAGE
1.0 Introductory Information - Little Brute Right Angle Puller ..................................................................................................................... 1
2.0 Safety ....................................................................................................................................................................................................... 2
3.0 LBRA-10 Specifications and Dimensions ............................................................................................................................................... 5
4.0 Tooling Selection ..................................................................................................................................................................................... 6
5.0 Assembly of the LBRA-10 onto a Little Brute Puller .............................................................................................................................. 8
6.0 Optional Adapters .................................................................................................................................................................................. 12
7.0 Assembly and Maintenance ................................................................................................................................................................... 13
8.0 Illustrated Parts Breakdown ................................................................................................................................................................... 16
FIGURES
Figure 2.0-1 Safety Stickers ......................................................................................................................................................................................... 3
Figure 3.0-1 LBRA-10 Dimensions ............................................................................................................................................................................. 5
Figure 4.0-1 LBRA-10 Mandrel ................................................................................................................................................................................... 6
Figure 4.0-2 LBRA-10 Nosecap .................................................................................................................................................................................. 7
Figure 5.0-1 Little Brute Puller Unit, Tooling Removed .............................................................................................................................................. 8
Figure 5.0-2 Little Brute Puller Unit, Endcap Removed .............................................................................................................................................. 9
Figure 5.0-3 LBRA-10, Rod Threaded ....................................................................................................................................................................... 10
Fatigue Technology Inc. 401 Andover Park East Seattle, WA • USA 98188-7605 Tel: (206)246-2010 Fax: (206)244-9886 796945
UNCONTROLLED IF PRINTED
TABLE OF CONTENTS (CONTINUED)
SECTION DESCRIPTION PAGE
Figure 5.0-4 LBRA-10, Installation Completed ......................................................................................................................................................... 11
Figure 6.0-1 LBRA-D15 and LBRA-D10 Adapters ................................................................................................................................................... 12
Figure 7.1-1 Retaining Ring Removal ........................................................................................................................................................................ 13
Figure 7.2-1 Greased Internals ................................................................................................................................................................................... 14
Figure 8.0-1 LBRA-10 Illustrated Parts Breakdown................................................................................................................................................... 16
BLES
TA
Table 3.0-1 LBRA-10 Specifications .......................................................................................................................................................................... 5
Table 4.0-1 CB Mandrels ............................................................................................................................................................................................ 6
Table 4.0-2 CA Mandrels ............................................................................................................................................................................................ 6
Table 4.0-3 CB Nosecaps ............................................................................................................................................................................................ 7
Table 4.0-4 CA Nosecaps ........................................................................................................................................................................................... 7
Table 8.0-1 LBRA-10 Parts List ............................................................................................................................................................................... 17
Fatigue Technology Inc. 401 Andover Park East Seattle, WA • USA 98188-7605 Tel: (206)246-2010 Fax: (206)244-9886 796945
This page intentionally left blank for two-sided printing.
Fatigue Technology Inc. 401 Andover Park East Seattle, WA • USA 98188-7605 Tel: (206)246-2010 Fax: (206)244-9886 796945
UNCONTROLLED IF
PRINTED
SECTION 1.0: INTRODUCTORY INFORMATION—LITTLE BRUTE RIGHT ANGLE PULLER
This instruction manual contains information on the operation and maintenance of the Little Brute Right Angle Puller (LBRA-10) designed by Fatigue Technology Inc. (FTI) for use with the patented Split Sleeve Cold Expansion™ (SsCx™) process. To obtain optimum performance and many years of trouble­free service, carefully follow maintenance procedures and operate the LBRA properly.
R
ead this manual before operating the LBRA, and retain the manual for future reference. If requested, FTI will provide this manual in the language of the
end-user.
T
he Little Brute Right Angle Puller is a compact, durable tool that enables coldworking in restricted access areas that are difficult or impossible to get to with
conventional tools.
Is capable of cold expanding holes in restricted access areas up to 0.50-inch (12.7mm) in diameter in aluminum and mild steel, or 0.375-inch (9.5mm) in diameter in titanium and high strength steel.
Attaches to the Little Brute (LB) series of puller units. See the Little Brute Puller Unit Operations, Maintenance, and Repair Manual for additional safety information.
The Right Angle Puller alone weighs approximately 2.6 pounds (1.18 kg); with the Little Brute Puller Unit, it weighs approximately 12.6 pounds (5.72 kg).
equires only 0.375-inch (9.53mm) lateral clearance (see Figure 3.0-1)
R
Head can rotate 360 degrees on the puller unit.
Has a maximum pull force of 8,000 pounds (maximum generated by the Little Brute Puller Unit).
T
he LBRA-10 is capable of much more pull force than the LBRA-7 and is physically larger. For low-force applications an LBRA-7 may be better suited.
This manual only covers the LBRA-10 and does NOT apply to the LBRA-7.
.
Fatigue Technology Inc. 401 Andover Park East Seattle, WA • USA 98188-7605 Tel: (206)246-2010 Fax: (206)244-9886 796945 1
UNCONTROLLED IF PRINTED
SECTION 2.0: SAFETY
afe operation of the LBRA is of paramount concern. Along with standard shop safety practices (eye protection, safe handling of high-pressure equipment,
S etc.), the following items are peculiar to the LBRA/puller unit assembly:
1
. Wear eye protection when operating the puller unit.
. Disconnect the air supply when:
2
Maintenance is to be performed Hydraulic hose is disconnected PowerPak is not in use
. Disconnect the LB Puller Unit from the PowerPak before attaching the LBRA.
3
. In the event of a ruptured or leaking hydraulic hose, IMMEDIATELY RELEASE THE TRIGGER AND DISCONNECT THE AIR LINE at the air
4
coupler from the PowerPak. Never use your hands to grasp a leaking hose under pressure. The force of escaping hydraulic fluid could cause serious injury.
5
. Keep hands away from the nosecap assembly while holding the nosecap against the workpiece.
6
. Release the puller unit trigger when the mandrel clears the workpiece or becomes stuck.
. The Little Brute end cap must always be in place while in use. Injury may occur if the end cap is removed during operation.
7
. Before operating the pump, tighten all hose connections using the proper tools. Do not over-tighten the connections. Connections need only be tightened
8
securely and leak-free. Over-tightening may cause premature thread failure or high-pressure fittings to split at pressures lower than their rated capacities.
. Operators must read this manual in its entirety before using the Little Brute Right Angle Puller. Eye and ear protection must be worn while operating
9
the Little Brute. Three safety stickers on the Little Brute Puller Unit series act as a reminder to these instructions. The symbols are shown in Figure
2.0-1.
10. Do not use in potentially explosive atmospheres.
Fatigue Technology Inc. 401 Andover Park East Seattle, WA • USA 98188-7605 Tel: (206)246-2010 Fax: (206)244-9886 796945 2
UNCONTROLLED IF PRINTED
ead manual before using Always wear eye protection Always wear ear protection
R
Fi
gure 2.0-1
Safety Stickers
Fatigue Technology Inc. 401 Andover Park East Seattle, WA • USA 98188-7605 Tel: (206)246-2010 Fax: (206)244-9886 796945 3
UNCONTROLLED IF PRI
NTED
Hydraulic Hose Safety
1. Inspect the hydraulic hose for signs of wear (cuts, abrasions, or kinks) to the outer shell material. Pump clean oil through the entire length. Pressurize the hose and check for leaks at the crimped connectors, between the hose material and the fitting, and between the fitting and the coupler.
. DO NOT attempt to disconnect the hydraulic hose while it is under pressure.
2
DO NOT expose hoses to potential hazards, such as extreme heat or cold, sharp surfaces, or heavy impact.
D
O NOT allow hoses to kink, twist, curl, or bend so tightly that the oil flow within the hose is blocked or reduced. Periodically inspect the hose for
wear or damage that could cause premature failure of the hose and possibly result in injury. Damaged hoses must be replaced immediately.
DO NOT use the hose to move attached equipment.
D
O NOT remove the strain reliever from hoses.
3
. Hose strain relievers must be placed around hose fittings during use. Hoses with damaged strain relievers must be replaced immediately.
. Hose material and coupler seals must be compatible with hydraulic fluid that meets the requirements of MIL-PRF-5606.
4
. Hoses must not come in contact with toxic materials, such as creosote-impregnated objects and some paints. Keep couplers and hoses clean and fr
5
o
f paint. Hose deterioration due to chemical degradation may cause the hose to fail under pressure. Damaged hoses must be replaced immediately.
. Before operating the PowerPak, make sure all hose connections are tightened securely. DO NOT over-tighten.
6
. If hoses require replacement, contact the FTI Sales Department.
7
ee
MPORTANT: FTI completed a risk assessment on this unit at our factory. Any modifications done by a third party or the final user are excluded from that
I
risk assessment.
Fatigue Technology Inc. 401 Andover Park East Seattle, WA • USA 98188-7605 Tel: (206)246-2010 Fax: (206)244-9886 796945 4
Model Number
LBRA-10
Mandrel
Attachment
3/8”-24
Thread
Nosecap
Attachment
11/16”-24
Thread
Maximum Pull
Force
8,000
Pounds
Mini mum Edge
Distance
UNCONTROLLED IF
PRINTED
SECTION 3.0: LBRA-10 SPECIFICATIONS AND DIMENSIONS
Weight
Stroke
2.6 Pounds
1.92”
0.375”
Table 3.0-1
LBRA-10 Specifications
Figure 3.0-1
LBRA-10 Dimensions
Fatigue Technology Inc. 401 Andover Park East Seattle, WA • USA 98188-7605 Tel: (206)246-2010 Fax: (206)244-9886 796945 5
Table 4.0-2
CA Mandrels
Figure 4.0-1
LBRA-10 Mandrel
SECTION 4.0: TOOLING SELECTION
STDN Size
Maximum Mandrel Length
Maximum Sleeve Length
STDN Size
Maximum Mandrel Length
Maximum Sleeve Length
4-0-N
CBM-4-0-N-10RA-16.4-V1
1.64”
20
CAM-20-10RA-16.4-V2
1.64”
4-1-N
CBM-4-1-N-10RA-16.2-V1
1.62”
21
CAM-21-10RA-16.4-V2
1.64”
4-2-N
CBM-4-2-N-10RA-15.8-V1
1.58”
22
CAM-22-10RA-16.3-V2
1.63”
4-3-N
CBM-4-3-N-10RA-15.8-V1
1.58”
23
CAM-23-10RA-16.1-V2
1.61”
4-4-N
CBM-4-4-N-10RA-15.9-V1
1.59”
30
CAM-30-10RA-16-V2
1.60”
6-0-N
CBM-6-0-N-10RA-16-V1
1.60”
31
CAM-31-10RA-15.9-V2
1.59”
6-1-N
CBM-6-1-N-10RA-16-V1
1.60”
32
CAM-32-10RA-15.9-V2
1.59”
6-2-N
CBM-6-2-N-10RA-15.7-V1
1.57”
33
CAM-33-10RA-15.7-V2
1.57”
6-3-N
CBM-6-3-N-10RA-15.7-V1
1.57”
40
CAM-40-10RA-15.2-V2
1.52”
8-0-N
CBM-8-0-N-10RA-15.7-V1
1.57”
41
CAM-41-10RA-15.1-V2
1.51”
8-1-N
CBM-8-1-N-10RA-15.7-V1
1.57”
42
CAM-42-10RA-15-V2
1.50”
8-2-N
CBM-8-2-N-10RA-15.4-V1
1.54”
43
CAM-43-10RA-14.9-V2
1.49”
8-3-N
CBM-8-3-N-10RA-15.4-V1
1.54”
50
CAM-50-10RA-14.6-V2
1.46”
10-0-N
CBM-10-0-N-10RA-15.2-V1
1.52”
51
CAM-51-10RA-14.5-V2
1.45”
10-1-N
CBM-10-1-N-10RA-15.2-V1
1.52”
52
CAM-52-10RA-14.5-V2
1.45”
10-2-N
CBM-10-2-N-10RA-15.1-V1
1.51”
53
CAM-53-10RA-14.4-V2
1.45”
10-3-N
CBM-10-3-N-10RA-15.1-V1
1.51”
12-0-N
CBM-12-0-N-10RA-15-V1
1.50”
12-1-N
CBM-12-1-N-10RA-15-V1
1.50”
12-2-N
CBM-12-2-N-10RA-14.8-V1
1.48”
12-3-N
CBM-12-3-N-10RA-14.8-V1
1.48”
14-0-N
CBM-14-0-N-10RA-14.6-V1
1.46”
14-1-N
CBM-14-1-N-10RA-14.7-V1
1.47”
14-2-N
CBM-14-2-N-10RA-14.5-V1
1.45”
14-3-N
CBM-14-3-N-10RA-14.5-V1
1.45”
16-0-N
CBM-16-0-N-10RA-14.4-V1
1.44”
16-1-N
CBM-16-1-N-10RA-14.4-V1
1.44”
16-2-N
CBM-16-2-N-10RA-14.2-V1
1.42”
16-3-N
CBM-16-3-N-10RA-14.2-V1
1.42”
Table 4.0-1
CB Mandrels
The LBRA-10 uses special mandrels and nosecaps that are not
UNCONTROLLED I
F PRINTED
Fatigue Technology Inc. 401 Andover Park East Seattle, WA • USA 98188-7605 Tel: (206)246-2010 Fax: (206)244-9886 796945 6
compatible with other FTI puller units.
Table 4.0-3
CB Nosecaps
Table 4.0-4
CA Nosecaps
Figure 4.0-2
LBRA-10 Nosecap
CB Nosecaps
CA Nosecaps
STDN Size
Model Number
STDN Size
Model Number
4-0-N
CBC-10RA-040F
20
CAC-10RA-20F
4-1-N
CBC-10RA-041F
21
CAC-10RA-21F
4-2-N
CBC-10RA-042F
22
CAC-10RA-22F
4-3-N
CBC-10RA-043F
23
CAC-10RA-23F
4-4-N
CBC-10RA-044F
30
CAC-10RA-30F
6-0-N
CBC-10RA-060F
31
CAC-10RA-31F
6-1-N
CBC-10RA-061F
32
CAC-10RA-32F
6-2-N
CBC-10RA-062F
33
CAC-10RA-33F
6-3-N
CBC-10RA-063F
40
CAC-10RA-40F
8-0-N
CBC-10RA-080F
41
CAC-10RA-41F
8-1-N
CBC-10RA-081F
42
CAC-10RA-42F
8-2-N
CBC-10RA-082F
43
CAC-10RA-43F
8-3-N
CBC-10RA-083F
50
CAC-10RA-50F
10-0-N
CBC-10RA-100F
51
CAC-10RA-51F
10-1-N
CBC-10RA-101F
52
CAC-10RA-52F
10-2-N
CBC-10RA-102F
53
CAC-10RA-53F
10-3-N
CBC-10RA-103F
12-0-N
CBC-10RA-120F
12-1-N
CBC-10RA-121F
12-2-N
CBC-10RA-122F
12-3-N
CBC-10RA-123F
14-0-N
CBC-10RA-140F
14-1-N
CBC-10RA-141F
14-2-N
CBC-10RA-142F
14-3-N
CBC-10RA-143F
16-0-N
CBC-10RA-160F
16-1-N
CBC-10RA-161F
16-2-N
CBC-10RA-162F
16-3-N
CBC-10RA-163F
UNCONTROLLED IF
PRINTED
Fatigue Technology Inc. 401 Andover Park East Seattle, WA • USA 98188-7605 Tel: (206)246-2010 Fax: (206)244-9886 796945 7
UNCONTROLLED IF
PRINTED
SECTION 5.0: ASSEMBLY OF THE LBRA-10 ONTO A LITTLE BRUTE PULLER
o install the LBRA-10 onto the Little Brute puller:
T
CAUTION: Before attempting any maintenance operations on the puller unit, disconnect the PowerPak from the air supply or disconnect the puller
from the PowerPak or hand pump.
. Remove all tooling from the barrel end of the Little Brute, including the threaded adapter (Figure 5.0-1).
1
Figure 5.0-1
Little Brute Puller Unit, Tooling Removed
Fatigue Technology Inc. 401 Andover Park East Seattle, WA • USA 98188-7605 Tel: (206)246-2010 Fax: (206)244-9886 796945 8
UNCONTROLLED IF PRINTED
2. Using a spanner wrench, loosen the lock ring on the back of the Little Brute and remove the endcap (Figure 5.0-2). A large flat screwdriver fits into the slot on the back of the piston to keep it from rotating.
Little Brute Puller Unit, Endcap Removed
Figure 5.0-2
Fatigue Technology Inc. 401 Andover Park East Seattle, WA • USA 98188-7605 Tel: (206)246-2010 Fax: (206)244-9886 796945 9
UNC
ONTROLLED IF PRINTED
3. Extend the inner rod from the back of the LBRA-10 and thread it onto the piston rod (Figure 5.0-3). Tighten securely while using a large flat screwdriver on the back of the Little Brute to keep the piston from rotating.
Figure 5.0-3
LBRA-10, Rod Threaded
Fatigue Technology Inc. 401 Andover Park East Seattle, WA • USA 98188-7605 Tel: (206)246-2010 Fax: (206)244-9886 796945 10
UNCONTROLLED IF PRINTEDUNCONTROLLED IF PRINTED
4. Re-install the Little Brute endcap and tighten the lock ring securely with a pinwrench. THE ENDCAP MUST BE IN PLACE DURING OPERATION. Thread the outer collar of the LBRA-10 onto the barrel of the Little Brute (Figure 5.0-4). The installation is now complete.
LBRA-10, Installation Completed
Figure 5.0-4
Fatigue Technology Inc. 401 Andover Park East Seattle, WA • USA 98188-7605 Tel: (206)246-2010 Fax: (206)244-9886 796945 11
UNCONTROLLED IF PR
INTED
SECTION 6.0: OPTIONAL ADAPTERS
ooling specifically designed for the LBRA-10 is optimized to be as compact as possible. However, adapters may be used to allow the attachment of
T conventional tools. Note that although all Little Brute tooling will thread onto the adapters shown, some mandrels may be too long for the limited stroke of the LBRA-10.
LBRA-D15 and LBRA-D10 Adapters
Figure 6.0-1
Fatigue Technology Inc. 401 Andover Park East Seattle, WA • USA 98188-7605 Tel: (206)246-2010 Fax: (206)244-9886 796945 12
UNCONTROLLED IF PRINTED
SECTION 7.0: ASSEMBLY AND MAINTENANCE
CAUTION: Before attempting any maintenance operations on the puller unit, disconnect the PowerPak from the air supply or disconnect the puller
er to Figure 8.0-1 for identification of the components.
Ref
from the PowerPak or hand pump.
7. 1 Di
Fatigue Technology Inc. 401 Andover Park East Seattle, WA • USA 98188-7605 Tel: (206)246-2010 Fax: (206)244-9886 796945 13
sassembly
o disassemble the LBRA-10, first remove it from the Little Brute. If a nosecap is mounted, take it off as well.
1. T
emove the retaining ring (8) using retaining ring pliers (Figure 7.1-1). The knurled collar (6) can now be removed along with the o-ring (10)
2. R
and washer (9).
Figure 7.1-1
Retaining Ring Removal
3. R
emove the four screws in the left half of the housing. The left housing can now be removed and the internal parts accessed for maintenance.
Grease
UNCONTROLLED IF PRINTED
7.2 Cleaning and Lubrication
The puller requires routine checking and periodic preventative maintenance to ensure safe, trouble-free operation. No special maintenance is required. The following maintenance actions are suggested.
. Periodically clean the outer surfaces of the unit.
1
2. The internal moving parts should be periodically lubricated with Mobil-HP or equivalent grease to ensure smooth operation and extend the life of the unit (Figure 7.2-1).
Fi
gure 7.2-1
Greased Internals
. Whenever the puller unit is to be stored for any length of time, maintain a thin coat of 10-weight oil on the outside surfaces to prevent rusting.
3
Fatigue Technology Inc. 401 Andover Park East Seattle, WA • USA 98188-7605 Tel: (206)246-2010 Fax: (206)244-9886 796945 14
UNCONTROLLED IF PRINTED
7.3 Replacing Parts/Repair
If parts need replacing or the unit needs repair, please contact FTI’s Sales Department. FTI will work with the operator to try to troubleshoot over the phone, but a return of the LBRA unit may be required.
7.4 Reassembly
eplace all internal components into the right half housing.
1. R
ttach the left housing half using the four screws.
2. A
3. Install the knurled collar (6), followed by the o-ring (10) and washer (9). Ensure that the o-ring and washer are fully seated all the way down.
4. I
nstall the retaining ring (8) using retaining ring pliers. The o-ring must be compressed to fit the retaining ring on, so it may be necessary to tap
the retaining ring with a blunt pin until the ring is fully snapped into the groove.
Fatigue Technology Inc. 401 Andover Park East Seattle, WA • USA 98188-7605 Tel: (206)246-2010 Fax: (206)244-9886 796945 15
UNCONTROLLED IF
SECTION 8.0: ILLUSTRATED PARTS BREAKDOWN
PRINTED
Fi
gure 8.0-1
LBRA-10 Illustrated Parts Breakdown
Fatigue Technology Inc. 401 Andover Park East Seattle, WA • USA 98188-7605 Tel: (206)246-2010 Fax: (206)244-9886 796945 16
Part
Number
UNCONTROLLED IF PRINTED
Item Number Quantity
Description
1 1 6908-001 Housing Sub-Assembly
2 1 6912-001 Puller Clevis
3 1 5305-002 Chain
4 1 6911-001 Mandrel Clevis
5 1 6917-001 Roller
6 1 6918-001 Knurled Collar
7 1 6916-001 Roller Pin
8 1 1199-450 External Retaining Ring
9 1 5301-002 Washer
10 1 1046-120 O-Ring
11 2 6915-001 Clevis Pin
12 1 1009-185 Caution Sticker
13 1 1199-452 Case
14 1 1009-293 FTI Sticker
15 1 1009-294 LBRA Sticker
Table 8.0-1
LBRA-10 Parts List
Fatigue Technology Inc. 401 Andover Park East Seattle, WA • USA 98188-7605 Tel: (206)246-2010 Fax: (206)244-9886 796945 17
UNCONTR
OLLED IF PRINTED
This page intentionally left blank for two-sided printing.
Fatigue Technology Inc. 401 Andover Park East Seattle, WA • USA 98188-7605 Tel: (206)246-2010 Fax: (206)244-9886 796945 18
Loading...