5.2.5 Stopping CA-dryer
during operation
1. Compressor’s internal overload protection (klixon) is tripped
⇒
⇒⇒
⇒ eliminate cause of trouble (see 3.4) or contact service.
CA-dryer will restart automatically after compressor has
cooled down.
Note: the immediate restarting of the unit is not possible
because the compressor’s overload protection requires a
minimum time to cool down to an acceptable operating
temperature.
2. Compressor or starting device is defective ⇒⇒⇒⇒ contact
service.
3. CA-dryer volume flow too high ⇒⇒⇒⇒ reduce volume flow; ⇒⇒⇒⇒
check whether CA-dryer’s capacity is properly selected,
increase CA-dryer’s capacity.
4. CA-inlet temperature too high ⇒⇒⇒⇒ restore normal conditions.
5. Ambient temperature too high or the room aeration is
insufficient ⇒⇒⇒⇒ Reduce temperature or provide proper
ventilation.
6. Refrigerant condenser fan is never running ⇒⇒⇒⇒ see 5.2.6.
7. Refrigerant condenser is polluted ⇒⇒⇒⇒ clean condenser.
8. CA-operating pressure too low ⇒⇒⇒⇒ increase operating
pressure; ⇒⇒⇒⇒ check whether CA-dryer’s capacity is properly
selected, increase CA-dryer’s capacity.
9. (type 1142A-1146A) Safety thermo-switch FTS is tripped ⇒⇒⇒⇒
see 5.2.8.
10. (type 1143A-1146A) Safety high pressure-switch FPA is
tripped ⇒⇒⇒⇒ see 5.2.9.
5.2.6 Refrigerant
condenser fan is
never running
1. Check and ensure electric wiring.
2. Fan’s internal overload protection is tripped ⇒⇒⇒⇒ eliminate
cause of trouble (see 3.4) or contact service. Fan will restart
automatically after it has cooled down.
3. (type 1130A-1138A) Electronic regulator is defective ⇒⇒⇒⇒
contact service.
4. (type 1139A-1146A) Fan control pressure switch SPV is
defective ⇒⇒⇒⇒ contact service.
5. Leak in the refrigerating fluid circuit ⇒⇒⇒⇒ contact service.
5.2.7 High differential
pressure at CA-side
1. CA-dryer volume flow too high ⇒⇒⇒⇒ reduce volume flow; ⇒⇒⇒⇒
check whether CA-dryer’s capacity is properly selected,
increase CA-dryer’s capacity.
2. CA-operating pressure too low ⇒⇒⇒⇒ increase operating
pressure; ⇒⇒⇒⇒ check whether CA-dryer’s capacity is properly
selected, increase CA-dryer’s capacity.
3. Pressure dew point too low ⇒⇒⇒⇒ see 5.2.3.
4. Condensate drain is not drained sufficiently ⇒⇒⇒⇒ see 5.2.12.
5. Heat exchanger polluted ⇒⇒⇒⇒ contact service.