TS-400 INSTALLATION INSTRUCTIONS
FSR
1.
DETERMINE LOCATION OF TS-400 ASSEMBLY AND REMOVE APPROPRIATE KNOCK-OUT PANELS FOR WIRES/CONDUITS
ROUTED TO THE TS-400 UNIT. USE THE TS-400 CHASSIS AS A TEMPLATE TO TRANSFER THE .328 DIAMETER HOLE
PATTERN TO WALL AND CEILING. HOLES USED TO SECURE CHASSIS WILL BE DETEREMINED ON SITE BY INSTALLER.
INSTALLER TO PROVIDE HARDWARE OR USE SUPPLIED TOGGLE BOLTS.
SHEET ROCK (1/2" MIN) / METAL STUD APPLICATIONS - WALL ANCHOR LOCATIONS - 6 TOP ROW, 2
SHEET ROCK (1/2" MIN) / WOOD STUD APPLICATIONS - LAG BOLTS WITH WASHERS MAY BE USED TO INSTALL
244 Bergen Boulevard, Woodland Park, NJ 07424, Phone: 973.785.4347 - Fax: 973.785.4207
BOTTOM ROW, MINIMUM 16" SPAN
TO WOODEN STUDS. WALL ANCHOR LOCATIONS - 2
TOP ROW, 2 BOTTOM ROW, MINIMUM 16" SPAN
BLOCK CONSTRUCTION - USE APPROPRIATE ANCHORS OR PROVIDED TOGGLE
BOLTS. WALL ANCHOR LOCATIONS - 2 TOP ROW, 2
BOTTOM ROW, MINIMUM 16" SPAN.
TS-400 - MAXIMUM
EQUIPMENT
LOAD - 50 LBS
CEILING
WALL
CEILING
WALL
WALL
TS-400 WITH COVER
B
43218 LIT1422
CEILING
TS-400 WITHOUT COVER
B
WALL
CEILING
A
A
.328 DIA. HOLES
14 POSSIBLE WALL
MOUNTING HOLES
.328 DIA. HOLES
15 POSSIBLE CEILING
MOUNTING HOLES -
IF CEILING MOUNT
IN LIEU OF WALL
MOUNT, MUST
SECURE TO
STRUCTURAL
WALL
MEMBER
SECTION A-A
SECTION B-B
CEILING
WALL
TO CEILING
ELECTRICAL DEVICE
(SUPPLIED BY CUSTOMER)
TS-400 CHASSIS
(COVER REMOVED)
REMOVE THIS FEATURE
FOR ELECTRICAL BOX
INSTALLATION ONLY
OPENING FOR
WIRES AND CABLES
(2) 1" CONDUIT
KNOCKOUT
TO WALL
(3) 1/2" & 3/4" CONDUIT
KNOCK-OUT
LOW SIGNAL DETAIL
ADDITIONAL OUTLETS
OR ELECTRICAL
DEVICES (SUPPLIED
BY CUSTOMER)
2-GANG ELECTRICAL
BOX (SUPPLIED BY
CUSTOMER)
USE SCREWDRIVER
TO REMOVE PLATES
AS REQUIRED
REMOVE THIS PLATE FOR
LOW VOLTAGE SIGNAL USE
AND
ELECTRIC BOX
INSTALLATION
TIE-WRAP POINT
TO SECURE WIRES
AND CABLES
REMOVE THIS FEATURE
FOR ELECTRICAL BOX
INSTALLATION ONLY
ELECTRIC BOX INSTALLATION DETAIL