FSR TS-400 User Manual

Page 1
TS-400 INSTALLATION INSTRUCTIONS
FSR
1.
DETERMINE LOCATION OF TS-400 ASSEMBLY AND REMOVE APPROPRIATE KNOCK-OUT PANELS FOR WIRES/CONDUITS ROUTED TO THE TS-400 UNIT. USE THE TS-400 CHASSIS AS A TEMPLATE TO TRANSFER THE .328 DIAMETER HOLE PATTERN TO WALL AND CEILING. HOLES USED TO SECURE CHASSIS WILL BE DETEREMINED ON SITE BY INSTALLER. INSTALLER TO PROVIDE HARDWARE OR USE SUPPLIED TOGGLE BOLTS.
SHEET ROCK (1/2" MIN) / METAL STUD APPLICATIONS - WALL ANCHOR LOCATIONS - 6 TOP ROW, 2
SHEET ROCK (1/2" MIN) / WOOD STUD APPLICATIONS - LAG BOLTS WITH WASHERS MAY BE USED TO INSTALL
244 Bergen Boulevard, Woodland Park, NJ 07424, Phone: 973.785.4347 - Fax: 973.785.4207
BOTTOM ROW, MINIMUM 16" SPAN
TO WOODEN STUDS. WALL ANCHOR LOCATIONS - 2 TOP ROW, 2 BOTTOM ROW, MINIMUM 16" SPAN
BLOCK CONSTRUCTION - USE APPROPRIATE ANCHORS OR PROVIDED TOGGLE
BOLTS. WALL ANCHOR LOCATIONS - 2 TOP ROW, 2 BOTTOM ROW, MINIMUM 16" SPAN.
TS-400 - MAXIMUM
EQUIPMENT
LOAD - 50 LBS
CEILING
WALL
CEILING
WALL
WALL
TS-400 WITH COVER
B
43218 LIT1422
CEILING
B
WALL
CEILING
A
A
.328 DIA. HOLES
14 POSSIBLE WALL
MOUNTING HOLES
.328 DIA. HOLES
15 POSSIBLE CEILING
MOUNTING HOLES -
IF CEILING MOUNT
IN LIEU OF WALL
MOUNT, MUST
SECURE TO
STRUCTURAL
WALL
MEMBER
SECTION A-A
SECTION B-B
CEILING
WALL
Page 2
TO CEILING
ELECTRICAL DEVICE (SUPPLIED BY CUSTOMER)
TS-400 CHASSIS
(COVER REMOVED)
REMOVE THIS FEATURE
FOR ELECTRICAL BOX
INSTALLATION ONLY
OPENING FOR WIRES AND CABLES
(2) 1" CONDUIT KNOCKOUT
TO WALL
(3) 1/2" & 3/4" CONDUIT KNOCK-OUT
LOW SIGNAL DETAIL
ADDITIONAL OUTLETS OR ELECTRICAL DEVICES (SUPPLIED BY CUSTOMER)
2-GANG ELECTRICAL BOX (SUPPLIED BY CUSTOMER)
USE SCREWDRIVER
TO REMOVE PLATES
AS REQUIRED
REMOVE THIS PLATE FOR
LOW VOLTAGE SIGNAL USE
AND
ELECTRIC BOX
INSTALLATION
TIE-WRAP POINT TO SECURE WIRES AND CABLES
REMOVE THIS FEATURE FOR ELECTRICAL BOX INSTALLATION ONLY
ELECTRIC BOX INSTALLATION DETAIL
Page 3
CEILING
#6-32 x .375 PAN HEAD SCREW
CABLE CLAMP
RACK MOUNT
BRACKETS
ALTERNATE
RACK MOUNT
HOLES
IPS MOUNTING PLATE
#6-32 KEP NUT
SEE WIRE SADDLE DETAIL
.188 DIA HOLE
CABLE CLAMP DETAIL
AFTER INSTALLATION OF ELECTRONIC
DEVICES, SECURE CABLE CLAMPS AS
REQUIRED TO THE VARIOUS .188 DIAMETER
HOLES TO ROUTE CABLES THRU THE TS-400
CHASSIS.
.188 DIA. HOLE
WIRE
SADDLE
WIRE SADDLE DETAIL
AFTER INSTALLATION OF
ELECTRONIC DEVI C E S,
SECURE WIRE SADDLES AS
REQUIRED TO THE VARIOUS
.188 DIAMETER HOLES TO
ROUTE CABLES THRU THE
TS-400 CHASSIS.
SEE CABLE CLAMP DETAIL
WALL
Page 4
1/4" TOGGLE BOLT INSTALLATION (8 PROVIDED)
1a. 1b.
STRAP
DRILL 1/2" DIA. HOLE
CAP
DRYWALL
CHANNEL
1c. 1d.
HOLD CHANNEL FLAT ALONG STRAP AND SLIDE CHANNEL THRU HOLE
PULL STRAPS UNTIL CHANNEL RESTS FLUSH BEHIND WALL, THEN SLIDE CAP UNTIL FLANGE OF CAP IS FLUSH WITH WALL
1e.
SNAP STRAPS AT WALL BY PUSHING SIDE TO SIDE, SNAPPING OFF STRAPS LEVEL WITH FLANGE OF CAP
1f.
SECURE TS-400 CHASSIS WITH 1/4"-20 HARDWARE (8 PROVIDED)
Page 5
2.
AFTER CHASSIS IS MOUNTED TO WALL, INSTALL COVER'S SAFETY CABLE TO CHASSIS.
TS-400 CHASSIS
CAPTURE TAB
SEE SAFETY CABLE DETAIL
CAPTURE TAB
a.
b.
SAFETY CABLE
PIN
CAPTURE TAB - OPEN POSITION
c.
(2) SAFETY CABLE
TS-400 COVER
SAFETY CABLE
CAPTURE TAB - CLOSED POSITION
(a.) ROTATE CABLE CAPTURE TAB AWAY FROM PIN. (b.) INSTALL COVER SAFETY CABLE ONTO PIN. (c.) ROTATE CABLE CAPTURE TAB BACK TO PIN
SAFETY CABLE DETAIL
Page 6
3.
INSTALL COVER ONTO CHASSIS. MAINTAIN TENSION ON SAFETY CABLE WHILE POSITIONING COVER TO CHASSIS. REVERSE STEPS TO REMOVE COVER FROM CHASSIS.
SEE LOCK DETAIL
UNLOCKED POSITION LOCKED POSITION
LOCK DETAIL
SUPPORT COVER AT THESE LOCATIONS
MAINTAIN TENSION ON
SAFETY CABLE WHILE
MOVING COVER UP
TO CHASSIS
TOP OF CHASSIS
BOTTOM OF COVER
WHILE KEEPING TENSION
ON SAFETY CABLE, ENSURE
BOTTOM SURFACE OF COVER
IS PARALLEL WITH TOP
OF CHASSIS
a.
b.
ONCE COVER STOPS AGAINST CHASSIS,
WHILE PUSHING UP, (a.) SLIDE COVER TOWARDS WALL UNTIL IT STOPS AND
(b.) ALLOW COVER TO DROP DOWN
APPROXIMATELY 1/8" TO INTERLOCK
WITH CHASSIS.