FSR SPC-20 User Manual

Owner’s Manual
SPC-20
SEQUENCING POWER CONDITIONER
FSR
Please be sure to read this manual before using this FSR electronic product. Additionally, to be sure of obtaining full protection under the terms of the Limited W arranty in the event that your original owner­ship documents are lost, fi ll out and return the W arranty Registration Card immediately . Also verify that the serial number on the Warranty Card matches the serial number on your unit.
POWER PRODUCT GROUP
Phone: 973-785-4347 Fax: 973-785-3318 Web: www.fsrinc.com E-Mail: sales@fsrinc.com
LIT1039B 82010
INTRODUCTION
Thank you for your purchase of an FSR SEQUENCING POWER CONDITIONER (SPC-20) and congratulations on your choice.
This equipment, not only sequences the power turn on, it also provides maximum protection form the types of hazards faced by delicate analog and digital pro audio and video equipment.
Your SPC-20 provides the most complete and comprehensive protection form power line­related transient voltages, noise and wiring faults available. It combines a high voltage surge and transient suppressor with an RFI/EMI interference fi lter. The fast-acting suppression circuit responds in less than a nanosecond, clamping transient voltages to safe levels, the lter works to prevent noise from fl uorescent lights, certain dimmers, radio transmitters, and similar sources of “electronic pollution” from contaminating the AC line and from there, leaking into sensitive audio, video, or computer circuits.
What sets the FSR SPC Series apart from other sequencers and conditioners is the use of TRIACS as the switching element instead of relays, which are prone to failure.
Also another distinguishing feature is the quantity, quality, and confi guration of its suppression devices. These include MOV’s,
gas discharge tubes, fast-blow fuses, and high voltage inductors and capacitors. This unique combination can safely absorb and dissipate large spikes from nearby lightning strikes and other sources as well as highly attenuate audible high frequency noise.
NOTE: SPC-20 requires that a safety ground be present for proper operation. Any attempt to operate the SPC-20 without a safety ground is considered improper operation and could invalidate the warranty.
Effects of Lightning
Lightning is a natural phenomenon of overwhelming force that represents the most diffi cult circumstance faced by a power protection product. The degree of protection a SPC-20 can offer depends on the intensity of the strike. If lightning strikes a distant power line and causes a relatively small disturbance to reach your location, the spike suppressors in the SPC-20 will absorb the excess voltage invisibly and harmlessly. H owever, if lightning strik es the actual building where the SPC-20 is installed (or somewhere very nearby) some damage may be unavoidable due to the extremely high voltage and current present. If this does occur, most likely damage will be limited to the SPC-20 itself and will affect only certain spike suppression components (called varistors or MOV’s.) In this “suicide” mode, the SPC-
20 may sustain minor damage but generally will protect all equipment plugged into it from much more serious and costly damage as long as the equipment is properly grounded. Proper grounding requires the use of three-prong AC cords, and that the building’s outlets are actually grounded to earth as specifi ed by local building codes.
Any SPC-20 known to have taken a direct lightning hit should be checked by a qualifi ed technician or the FSR factory to determine whether the MOV’s need replacement. If
the surge circuits indicator is not lit, there is defi nitely some damage. Some spike suppression capability may still be available, but there is no guarantee of this.
For optimum protection, you should not rely exclusively on the SPC-20 to protect against a direct lightning hit. The fi rst line of defense against lightning should be a lightning arrestor installed on your building’s electrical service entrance. If your building does not have one, contact your local power company or a contractor to have one installed.
FSR
POWER PRODUCT GROUP
Phone: 973-785-4347 Fax: 973-785-3318 Web: www.fsrinc.com E-Mail: sales@fsrinc.com