FSR PWB-270 User Manual

Page 1
FSR
PWB-270 / PWB-273-CRST-DM INSTALLATION INSTRUCTIONS
244 Bergen Boulevard, Woodland Park, NJ 07424, Phone: 973.785.4347 - Fax: 973.785.4207
COMPONENT MOUNTING DETAIL
WOOD STUD MOUNTING
WALL OPENING: 14-3/8" x 10-1/8" NOTE: BOX CAN BE ORIENTED IN ONE OF TWO POSITIONS
(4) #8 x 3/4" WOOD SCREW
UPPER COVER
CRESTRON DM SCALER (SOLD SEPARATELY)
(4) #6-32 x 1-1/4" LG PAN HEAD SCREW
BRACKET ASSEMBLY
(4) #6-32 x 1/4" LONG FLAT HEAD SCREW
LOWER COVER
(4) #6-32 x 3/4" OVAL HEAD SCREW
ENSURE REAR SURFACE OF BOX DOES NOT
EXTEND PAST SURFACE OF WALL STUD
16" STUD CENTERS
(2" x 4" WOOD STUDS SHOWN)
1/2" FROM STUD TO BOX EDGE
43219 LIT1425A
Page 2
STEEL STUD MOUNTING
WALL OPENING: 14-3/8" x 10-1/8" NOTE: BOX CAN BE ORIENTED IN ONE OF TWO POSITIONS
UPPER COVER
(2) #8 x 3/4" SELF-DRILLING SCREW
(FOR FLAT SIDE OF STUD)
(2) #8 x 2" SELF-DRILLING SCREW
(FOR OPEN SIDE OF STUD)
(4) 1" & 1-1/4" KNOCKOUT
(9) TIE WRAP POINT TO SECURE WIRES AND CABLES
SEE ELECTRIC BOX KNOCKOUT DETAIL
LOWER COVER
ENSURE REAR SURFACE OF BOX DOES NOT
EXTEND PAST SURFACE OF WALL STUD
1/2" - 5/8" WALL THICKNESS
1/2" FROM STUD TO BOX EDGE
(4) #6-32 x 3/4" LONG OVAL HEAD SCREW
16" STUD CENTERS
(2" x 4" STEEL STUDS SHOWN)
(UPPER COVER NOT SHOWN)
LOWER COVER
(5) TIE WRAP POINT
TO SECURE WIRES
AND CABLES
(2) ELECTRIC BOX KNOCKOUT
(2) 1" KNOCKOUT
REMOVE FOR INSTA LLATION OF ELECTRIC BOX
REMOVE FOR INSTALLATION
OF ELECTRIC DEVICE
ELECTRIC BOX KNOCKOUT DETAIL
Loading...