CB-12P INSTALLATION INSTRUCTIONS
FSR
1.
PRIOR TO CEILING INSTALLATION, DETERMINE MOUNTING LOCATION
OF THE FLANGE FOR THE PROJECTOR MOUNT. IF DEFAULT FACTORY
LOCATION WILL BE USED, PROCEED TO STEP 2. IF CHANGING TO
ALTERNATE LOCATION, FOLLOW STEPS 1a THRU 1b.
NOTE: FLANGE LOCATION CAN BE CHANGED AFTER
CEILING INSTALLATION.
1a. 1b.
REMOVE POLE MOUNT PLATE COVER (COVER
SCREWS LOCATED IN INTERIOR OF CEILING BOX).
PART OF
POLE MOUNT
PLATE COVER
244 Bergen Boulevard, Woodland Park, NJ 07424, Phone: 973.785.4347 - Fax: 973.785.4207
COVER SCREWS LOCATED IN
INTERIOR OF CEILING BOX
(2) PLUG
MAKE SURE PROJECTOR
MOUNT SET SCREW IS
ORIENTED TOWARDS THE
ACCESS HOLE IN THE POLE
SET SCREW ACCESS HOLE
POLE MOUNT
PLATE COVER
REMOVE FLANGE AND MOVE TO ALTERNATE
LOCATION. CHANGE PLUG LOCATION ON THE POLE
MOUNT PLATE COVER AS REQUIRED, AND
RE-INSTALL THE PLATE COVER WITH THE (2)
ORIGINAL SCREWS.
(4) #10-32 x 3/4" LONG
HEX SCREW
(4) #10 LOCK WASHERS
MOUNT PLATE
POLE MOUNT FLANGE
POLE MOUNT PLATE
2.
INSTALL CB-12P TO A STRUCTURAL CEILING ABLE TO
SUPPORT FIVE TIMES THE NOTED GROSS WEIGHT. USE
APPROPRIATE MOUNTING METHODS BASED ON LOCAL
BUILDING CODES. INSTALL SAFETY CABLE AS REQUIRED BY
LOCAL BUILDING CODES. ROUTE CONDUITS TO BOX AS
REQUIRED.
NOTE: MAXIMUM GROSS WEIGHT - 110 LBS
NOTE: THREADED ROD IS THE
RECOMMENDED CEILING BOX
MOUNTING SUSPENSION
(SHOWN), TO MINIMIZE
FIXTURE TILTING DUE
TO THE WEIGHT OF ANY
SUSPENDED EQUIPMENT.
14 GA. STEEL TIE WIRE MAY BE USED
(SUPPLIED BY CUSTOMER OR USE FSR KIT)
AT 70,000 PSI TENSILE STRENGT H OR
BETTER AS REQUIRED BY BUILDING CODES.
AVAILABLE KITS (SOLD SEPARATELY):
CB-MNT1 - CABLE INSTALLATION KIT
CB-THRD - THREADED ROD INSTALLATION KIT
NOTE: WIRES SUPPORT CEILING
BOX, AND ARE NOT
THREADED ROD OR CABLE TO
BE PLUMB WITH CEILING AND FLOOR
SAFETY CABLES
ROUTE CONDUIT
(SUPPLIED BY
CUSTOMER) TO
KNOCKOUTS
AS REQUIRED
STRUCTURAL
MEMBER
ALL MOUNTING HARDWARE
SUPPLIED BY CUSTOMER
STRUCTURAL
CHANNEL
BRACKET - FSR'S
THREADED ROD
INSTALLATION KIT
(HARDWARE SUPPLIED
BY CUSTOMER)
43189 LIT1317B

3.
INSTALL 10-3/4" x 15-1/4" DROP CEILING PANEL MATERIAL
INTO DOOR OF CB-12P. BEND CAPTURE TABS OVER
PANEL TO HOLD PANEL IN PLACE.
4.
REMOVE SHELF AND MOUNT ELECTRONICS TO SHELF.
USE HOLE/SLOT PATTERN ON SHELF TO MOUNT
EQUIPMENT. ADDITIONAL HOLES MAY BE REQUIRED.
RE-INSTALL SHELF INTO CB-12P. MAKE ELECTRICAL
CONNECTIONS AS REQUIRED.
NOTE: MAXIMUM LOAD PER SHELF - 20 LBS EACH
LOOSEN SCREWS (4 PER SHELF)
TO REMOVE SHELVES
10-3/4" x 15-1/4"
DROP CEILING
PANEL MATERIAL
(SUPPLIED BY
CUSTOMER)
(4) CAPTURE TAB
TO OPEN CB-12P DOOR
LOOSEN SCREWS
NOTE: MAXIMUM PROJECTOR LOAD INCUDING MOUNTED ACCESSORIES - 50 LBS
b
a
DISCONNECT
SAFETY CABLE
TO COMPLETELY
REMOVE DOOR
5.
INSTALL PROJECTOR MOUNT PIPE INTO CB-12P. SECURE
PIPE WITH SET SCREW. FINISH INSTALLATION PER
MANUFACTURER'S PROJECTOR MOUNT INSTRUCTIONS.
DOOR IS
REMOVABLE.
(a) PUSH DOOR
UP TOWARDS
CEILING AND
(b) PUSH AWAY
FROM
PROJECTOR
PANEL MOUNT -
REVERSE
PROCEDURE
TO INSTALL
LOOSEN SHELF
SCREWS. (a) PUSH
SHELF TOWARDS
PROJECTOR
MOUNT AND (b) SHELF
WILL DROP DOWN OUT
OF CB-12P
(2) SHELF
a
b
NOTE: THE CENTER OF MASS
OF SUSPENDED EQUIP MENT MUST BE WITHIN
A 2.5" RADIUS OF THE
CENTER LINE OF THE
FLANGE MOUNT OF THE
CEILING BOX.
PROJECTOR MOUNT PIPE
(SUPPLIED BY CUSTOMER)
PROJECTOR MOUNT SET
SCREW ACCESS HOLE
FSR Inc.
244 Bergen Boulevard, Woodland Park, NJ 07424
Phone: 973.785.4347 - Fax: 973.785.4207
Web: www.fsrinc.com - E-mail: sales@fsrinc.com