FSP Technology Nano 400, Nano 600, Nano 800 Quick Manual

Na no UPS Qu ick Guide
V. 1. 0
Pa c k age Conten t s
You s hou l d have rec ei v ed th e fol l ow ing i t em s i n si d e of pa cka ge:
UP S Uni t Qu ick G uid e
-Pow e r cab le (o nly f or th e I EC- ty pe mo d el )
--
1
4
Ins tallatio n & I n itial Start u p
NO TE :
Plac eme n t & Sto ra g e Con d it ion s
Co nnect to U t il it y a nd Ch arg ing
Be f or e inst allat ion , p le a se in spe ct th e u nit . B e su r e tha t
no thi ng in sid e t he pa cka g e is da m ag e d.
In st a ll th e UPS in a p r ot ect e d are a tha t i s fr e e of ex ces siv e d us t a nd ha s a deq ua t e ai r flo w. P l ea s e pla ce th e U PS aw ay fr om ot her un its a t l ea s t 20 cm t o a vo i d in ter fe r enc e. Do NOT op e ra te th e U PS wh e re th e tem per atu re an d h um i dity is ou tsi de th e s pec ifi c lim its . (Pl eas e c hec k t he sp ecs f o r th e l im i tat ion s.)
Be for e ini ti a l use , p le a se pl ug in th e AC i np ut c ord to the
wall outle t an d tu rn on th e UP S for char gi ng . Fo r the be st result s, s ug gest to charg e the batter y at l ea st 8 hou rs before initi al use. The UPS ch arges its battery w hi le connec ti ng to th e ut ili ty wit h power on .
Plug i n the loads to out pu t re ce ptacles o n the rear panel of the UPS. Simply turn on the power swit ch o f UP S un it , then devices conn ec te d to the U PS w il l be protected by UPS unit .
connect a lase r pr in te r or s canne r to
the UPS unit . This may cause t he d amag e of t he unit.
Connect t he L oa ds
CAU TI ON: NE VER
Tu rn On /Of f t he U nit
In di c at o rs & Al arm T abl e for O per a ti on
Turn on th e UPS un it by p r es sin g t he po wer sw itc h. Tur n off t he UPS u nit b y pr ess ing a g ai n t he po wer s w it c h.
2
Front V iew :
Ba ck Vi ew:
AC input Output rec ep ta cle s Circui t brea ke r
Pow er switch UPS status indic ato r Fault /B atter y stat us ind icator (Check t he Indic ator & Ala rm Table f or t he det ai ls)
1 2 3
IEC Type
1
2
3
NEMA Type Univer sa l Type S ch uk o Type
Pr o duct Overvi e w
3
Pr o duct Intro d u ction
1
2
3
The Nan o UPS pr ov ide s compre he nsive protect ion in a sma ll a nd e co nomi c pa ckage . The UPS is mo re c ompact and offers greater com pr ehensive power prot ec tion against surges a nd spikes. T hi s UP S wi ll contin ue p ro vi di ng sta ble pow er to conn ec ted equipmen t an d en ab le to sh utdown PC safely during p ow er fai lu re. It s embedde d microp ro ce ssor cont ro ll er guarantees hig h reli ab ili ty and i t’s perfec t fo r any home or small offic e ap pl icati on .
1 2 3
2
31
8 ho ur s
20 cm
20 cm
Condit ions Vi su al Ind icat ions Ala rm
Off
Gree n LE D li gh ti ng Green LED fl as hi ng
eve ry 10 se conds
Green LED flashing eve ry
se co nd & Red LE D light in g
Sounding eve ry 1 0 second s
Sounding eve ry sec on d
AC mo de
Batter y mo de
Low bat ter y at batt er y mode
Fault Red LED lighti ng Con tinuo us ly s ou ndi ng
Alar m for over­temperatur e protec ti on
Red L ED f lashi ng e very 0.5
second s
Off
Tro u ble Shoot i n g
6
Us e the t a ble b e lo w t o sol ve mi n or prob l em s .
Important Saf ety W arning (SAV E TH ESE INSTRUCTI ONS)
5
CAU TI ON!
CAU TI ON!
CAU TI ON!
CAU TI ON! CAU TI ON!
CAU TI ON!
CAU TI ON!
Attention
To preven t the ri sk of fi re or el ect ri c sh ock, inst al l in a t em pe ra tu re and humidi ty c on trol led ind oo r ar ea f ree of c on du ctive contami na nts. (See the spec if icati ons fo r th e ac ce pt able temperatur e an d hu mi di ty r an ge .)
To reduce t he r is k of o ve rh eat in g the UP S, do not cover the UPS' coo li ng vents and avoid exposing t he uni t to d ir ec t su nli gh t or ins ta lling t he u ni t ne ar hea t emitti ng app li ances s uch as s pa ce hea te rs or fu rn aces.
Do not attac h non- co mputer-rela te d item s, such as med ica l eq ui pment,
life -s up po rt equi pmen t, mic rowa ve ove ns , or vac uu m cl ea ners to UPS.
Do no t pl ug the U PS inp ut int o its own output.
Do not all ow l iq ui ds or an y fore ig n ob je ct to en t er t he UPS. Do no t place
beverages or any other liquid- contain in g vessels on or near the unit.
In th e even t of an emer ge nc y, press the OFF button and di sco nn ec t the power co rd from th e AC po wer su ppl y to pro pe rly di sable the UPS.
Do not attac h a power stri p or sur ge s up pr essor to the UP S.
hazard ous throug h el ec tri c shoc k. Als o wi th disc onne cti on o f this u ni t from the ma ins, haza rd ou s volt ag e sti ll m ay be access ib le thr ough supply f ro m batt er y. The bat tery supp ly sho ul d be t he re fo re d isc on ne cted i n th e pl us a nd min us pole at th e quic k co nn ec tors of the batt ery when main te na nc e or servic e work ins ide the UPS is neces sa ry.
CAU TI ON!
CAU TI ON!
If the UPS i s with m et al cha ss is, for safety purpos e, g roun di ng is a mu st
during U PS ins ta llati on i n or de r to r ed uc e le akage current b el ow 3 .5mA .
Internal bat te ry vol ta ge i s 12 Vd c. Seal ed , le ad -acid, 6-ce ll b at tery.
CA UTION!
CA UTION!
CA UTION!
CA UTION! CA UTION!
Servi c in g o f bat ter ie s s hou ld be pe rfo rme d o r sup erv ise d b y per son nel kn owl edg eab le of ba tte rie s and th e req u ir ed pr eca uti o ns . Kee p una u tho ri z ed pe rso nne l a wa y f ro m bat t er i es.
Wh e n re p la c ing t he ba t te r ie s , us e t he sa m e num ber an d typ e o f batte r ie s .
Do no t dis pos e o f bat ter ie s i n a f ir e . The b att e ry m ay exp lod e. Do no t op en or mu ti l at e t he ba t te r y or ba tte r ie s. Re lea sed e lec t ro lyt e i s har mfu l to th e s kin an d e ye s .
Un p lu g t he UP S p ri o r to cl ean ing an d d o no t u se li q ui d o r spr ay de tergen t.
A ba t te r y can pres e nt a ri sk of e l ec t ric s hoc k a nd hi gh sh ort ci rcuit cu rre nt. T he fo llo w in g p re c aut io n s hou l d be ob s er ved b e fo re re p la c in g b att er i es :
1) Rem ove w atc hes , rin gs, or o the r m et a l obj ect s.
2) U se t o ol s w ith i n su l at e d han dle s.
3) We ar rub ber g loves an d b oo t s.
4) Do not l ay to ols o r m et a l p ar ts on to p o f batte r ie s .
5) Dis con nec t c har gin g s ou rce pr io r t o c on n ec t in g o r dis c on n ec t ing b att eri es te rmi nal .
Sp e c ifications
7
Pro blem Prob ab le Cau se Solut io n
No LE D di splay on th e fr on t panel.
Alar m contin uousl y sounds when the mains is nor ma l.
Alar m so unds e ve ry 2 sec onds when t he mains is nor ma l. Whe n po wer fa ils, back up tim e is shor te n.
The mains is nor mal but green LE D is flashi ng.
Low bat ter y. Batter y faul t.
The UPS is no t tu rned on.
The UPS is ov er load.
UPS fau lt Batter y de fe ct
Chargi ng cir cu it is da maged. The UPS is ov er load. Batter y vo lt age is t oo low. Batter y de fe ct .
Pow er cord is loose.
Charge the UPS at leas t 8 hours. Rep lace the battery wi th t he same type of battery. Press the po we r swit ch again to t ur n on the UPS. Rem ov e so me l oa ds f irst. Before rec on ne cting equ ip me nt , please verif y th at t he loa d matche s the UP S capa bi lity spec if ie d in t he s pecs. Ret urn the unit to servi ce cen ter. Rep lace the battery wi th t he same type of battery. Ret urn the unit to servi ce cen ter. Rem ov e so me cri tic al l oa d. Charge the UPS at leas t 8 hours. Rep lace the battery wi th t he same type of battery. Rec on nec t th e powe r co rd prop erly.
Mod el Nan o 400 Nano 600 Nano 800
CA PA CI TY IN PU T
OU TP UT
BA TT ER Y
PR OT EC TIO N
PH YS IC A L
EN VI RO NME NT
Vol tag e Vol tag e Ra ng e Freq ue n cy
Ou tp ut Vol tag e (A C mod e) Ou tp ut Vol tag e (B at. m od e) Tran sfer Ti me Wav ef o rm
Typ e & Nu m be r Ch ar ging Ti me
Fu ll P ro t ec ti o n
Di me nsion ( DxW xH m m ) Ne t We ig ht (k gs )
Hu mi d ity Tempe ra tu re
40 0 VA / 2 40 W 60 0 VA / 36 0 W 8 00 V A / 480 W
12 V /4 .5 AH x 1 12 V / 7 AH x 1 1 2 V/ 9 A H x 1 8 h ou rs re co ve r to 90 % c ap ac i ty
Ov erc h ar ge , dis ch arge , sh or t ci rc ui t, a nd t he rm al p ro te ct io n
110/ 120 VAC o r 22 0 /2 30 /24 0 VA C
90 ~1 4 5 VAC or 1 80~ 27 0 VA C
50 H z or 60 H z
same as i np ut
12 0 VA C ± 1 0% / 23 0 VAC ± 10%
2-6 ms ( Typi ca l)
Si mu lat ed S i ne Wav e
0- 90 %
0-40 C (non -c o nd en si n g)
22 8 x 82 . 5 x 207
2.2 2 .7 3 .1
Loading...