FSH FEL990 Series Installation Instructions Manual

For left hand VESTIBULE
For right hand VESTIBULE
To set for C COMBINATION
Remove outer Face Plate1.
2. Pull & Rotate Latch Bolt 180 degrees clockwise
HANDING AND LOCKING FUNCTION SELECTION
TO REVERSE LATCH BOLT
If the handing and locking function selector is not visible through the view hole - the lock is set for Fail Secure (FSE). To make the handing and locking function selector visible, use the holdback clip
- see overleaf for Fail Safe (FSA) Fail Secure (FSE) selection.
FEL990 Series lectric Mortice Lock Installation Instructions
E
FSH is an Allegion™ Company
selector
HANDING AND LOCKING FUNCTION SELECTOR
selector
selector
FAIL SAFE (FSA) / FAIL SECURE (FSE) SELECTION
SECURING THE CYLINDER
Use only the Cylinder Retaining Screw supplied, ensuring the Retaining Screw Head is flush with the Inner Forend Face.
nip
1. Mark out for strike on door frame.
LOCK INSTALLATION
When installing the lock, leave the plastic cylinder dust covers covering the cylinder hole to prevent particles from entering the lock. Where a cylinder is required, extract the dust cover as shown in the illustration.
2. Door frame to be morticed out for strike and strike box.
3. Fix strike box and strike to door frame using 2 screws as supplied with the lock.
4.
MOUNTING STRIKE AND MAGNET
Drill 19mm DIA hole (depth to suit magnet),
62mm above centre line of strike. Magnet to be inserted into hole.
WARNING - Do not use instruments such as screw drivers to retract the latch bolt through the cylinder hole. Damage to the lock circuitry could occur.
(FSA)
(FSA)
FSA
FSA
FSA
FSA
FSA
FSA
FSA
FSA
FSA
FSA
20mm
FEL990
FEL990 SERIES
9PIN PLUG CONNECTION
(1.6m of cable supplied as standard)
LOCK INSTALLATION
(swapping LED wires)
SWAPPING WIRES
Gently lift plastic tag holding terminal & slide wire terminal from plug. To insert wire terminal, slide back into plug.
This product is the subject of any one or more of the following patents, NZ299577, AU717917, NZ529951, NZ535262, NZ534706, NZ534938, NZ537284, NZ534626.
N
*
*Hub monitoring is exit side only
FSH Australia Pty Ltd
Phone 1300 374 374 Website www.fshlocking.com.au
NOTES: Swaping LED wires over for Fail Secure (FSE) for both LH/RH sides of lock.
LED cables are supplied as standard to suit Fail Safe (FSA) for both LH/RH sides of the lock. On the occasion where Fail Secure is selected the red and green wires on the LED cable will have to be swapped over to suit LH/RH sides of the lock.
FEL990 Series Monitoring Functions
Door Position Monitoring by Reed Switch
Lock Status Monitoring by a combination of 3 locking perimeters
• Locking Bar (Hub/Handle/s locked)
• Deadlatching Bolt (suppressed)
• Latchbolt (out)
Dual Key Override Monitoring (KOM)
Request to Exit (REX) via Hub/Handle(s)
LED Indication
ON
OFF
FSH is an Allegion™ Company
Electrical Specications
Solenoid Activation
12-24V DC 350mA momentary, 100mA max operating Including LED if applicable
Lock Secure Status/Key Override Monitor
Microswitch max. rating 500mA @30V DC
Door Status Monitor
Magnetic Reed Switch 100mA operating
Plug arrangement
9 pin plug with 1.6m cable
Request to Exit (REX) Switches
Microswitches max. rating 1A @125VAC
1
Solenoid Off
Solenoid On
Solenoid
NC
NO
Right Hand Operation (RH)
DIP 3
DIP 4
Reed Switch
NC
NO
Left Hand Operation (LH)
DIP 6
DIP 5
Dead Latching Bolt
NC
NO
Key Override
DIP2
DIP 1
Regulator
LED Drive
2
Black
Red
0 VDC
Solenoid
Green LED (+) for Solenoid Off
Yellow
Reed Switch
Grey
Signals
Unused
Blue
Hub Monitor (Handle)
Violet
Key Overirde Monitor
Orange
Latch Bolt, Dead Latching
Red LED
Lock Status :
Green LED
FEL990(M) Wire Connection Diagram
12-24VDC
Common
12-24VDC
(RH/LH, NO/NC)
Bolt & Lock/Unlock
(Both Sides)
Door Open at Rest Unlocked (Fail Safe)
Door Locked Fail Safe (FS)
Door Unlocked
Fail Safe (FS)
Swap LED Leads for Fail Secure
(Secure Status)
(Door Closed Status)
9 Pin Plug
NC
NO
Latch Bolt Monitor
Brown
Monitored version (M)
5
4
3
6
7
8
9
Locking Bar, (Handle(s) Locked)
POWER
SWAPPING WIRES
Gently lift plastic tag holding terminal & slide wire terminal from plug. To insert wire terminal, slide back into plug.
N
Allegion (New Zealand) Limited
Phone 0800 477 869 Website www.allegion.co.nz
PIN Colour Function
1 Black O VDC
2 RedSolenoid black
3 Light Blue Solenoid, lath and deadbolt lock/unlock
4 Blue Hub monitor (handle) (RH/LH, NO/NC)
5 Grey Solenoid, lath and deadbolt common
6 Violet Key override monitor (both sides)
7 Brown Hub common
8 Pink Reed common
9 Orange Key override monitor
10 Yellow Reed switch (door closed status)
11 Green LED (+) for solenoid o 12-24VDC
12 White Lock/unlock (secure status) centre tap
1
Solenoid Off
Solenoid On
Solenoid
NC
NO
Right Hand Operation (RH)
DIP 3
DIP 4
Reed Switch
NC
NO
Left Hand Operation (LH)
DIP 6
DIP 5
Dead Latching Bolt
NC
NO
Key Override
DIP2
DIP 1
Regulator
LED Drive
2
Black
Red
0 VDC
Solenoid
Green
LED (+) for Solenoid Off
Yellow
Reed Switch
Grey
Solenoid, Latch & Deadbolt
Hub Common
Blue
Hub Monitor (Handle)
Violet Key Overirde Monitor
Light Blue
Lock/Unlock (Secure Status)
Red LED
Lock Status :
Green LED
FEL990M (12 Pin) Wire Connection Diagram
12-24VDC
Common
12-24VDC
(RH/LH, NO/NC)
Lock/Unlock (Secure Status)
(Both Sides)
Door Open at Rest Unlocked (Fail Safe)
Door Locked Fail Safe (FS)
Door Unlocked
Fail Safe (FS)
Swap LED Leads
for Fail Secure
(Door Closed Status)
12 Pin
Plug
NC
NO
Latch Bolt Monitor
www.fshlocking.com.au
Brown
11
10
5
7
4
6
3
Locking Bar, (Handle(s) Locked)
Pink
8
Reed Common
Orange
9
White
12
Key Overirde Monitor
Solenoid, Latch & Deadbolt
Centre tap
LOCK INSTALLATION
(swapping LED wires)
SWAPPING WIRES
Gently lift plastic tag holding terminal & slide wire terminal from plug. To insert wire terminal, slide back into plug.
N
*
*Hub monitoring is exit side only
SWAPPING WIRES
Gently lift plastic tag holding terminal & slide wire terminal from plug. To insert wire terminal, slide back into plug.
N
12
(3m of cable supplied as standard)
12 pin plug with 3m cable
VERSION ac.mob 09.16