FRÄNKISCHE profi-air 180 flat Installation And Operating Instructions Manual

profi-air® 180 flat connection box
Installation and operating instructions
DRAINAGE SYSTEMS
ELECTRICAL SYSTEMS
BUILDING TECHNOLOGY
INDUSTRIAL PRODUCTS
Table of contents
1 General
1.1 Introduction 3
1.2 Safety 3-4
2 Intended use 4
3 Structure 4
4 Scope of delivery 4
5 Technical data
5.1 Connection options 5
5.2 Dimensional drawing 5
5.3 Schematic wiring diagram 6
6 Wiring diagrams 6
6.1 Modbus (connection to the ventilation unit) 7
6.2 Fire/smoke alarm input 7
6.3 Humidistat input 8
6.4 Standby input 9
6.5 External fan activation input 10
6.6 Error message output 10
7 Warranty 11
8 Liability 11
9 Disposal 11
All infor mation in this p ublicatio n generally reflects the st ate of the art at th e time of printin g. Further more, consid erable care w as taken when pre paring this publication. Neverthe less, typ esetting and trans lation error s cannot be entirely excluded . We also reser ve the right to make c hanges to our products, sp ecificati ons and other da ta. Changes may also beco me necessar y as a result of legal, materia l-relate d or other techn ological re quirements, which cannot o r can no longe r be considered in this publi cation. For t his reason, we c annot assume a ny liability which is base d solely on the d ata provide d in this publication. The d ecisive role w ith regard to the data on produ cts and ser vices is alway s played by the or der placed , the product a ctually purc hased and the d ocumentat ion in connec ­tion wit h it, or the information provid ed by our spec ialist staf f in each spec ific indivi dual case.
MBA profi-air 180 flat connection box
FRÄNKISCHE
1 General
The profi-air 180 flat connection box extends the range of electric wiring
1.1 Introduction
These installation and operating instruc­tions are intended to help you install a fully functional profi-air 180 flat connec­tion box and properly operate it. We rec­ommend that you read these instructions carefully before you com-
1.2 Safety
If used for its intended purpose, the device is safe and reliable to operate. The construction and design are state of the art and comply with all relevant
options of the profi-air 180 flat ventila­tion unit.
mence installation. These installation and operating instructions can also serve as a reference for service and maintenance work and guarantee smooth and efficient operation.
DIN / VDE regulations and safety provi­sions. All safety regulations, warnings and notices of these installation and operating instructions have to be com-
plied with; non-compliance may result in personal injury and/or damage to the profi-air 180 flat connection box.
1.2.1 Safety regulations
n
Installation, connection and taking
into operation of the profi-air 180 flat connection box must be performed by authorised and qualified person­nel only.
n
Installation of the profi-air 180 flat
connection box must be carried out according to applicable local con­struction, safety and installation reg­ulations.
n
Unauthorised changes or modifica-
tions of the profi-air 180 flat connec­tion box are not permitted.
n
Keep these installation and operating
instructions near the device during the entire life of the profi-air 180 flat connection box.
MBA profi-air 180 flat connection box
3FRÄNKISCHE
1 General
1.2.3 Symbols used
Risk of personal injury
Risk of:
n
damage to equipment

n
errors while operating the device if the instructions are not complied with correctly
n
other material damage
Additional notices
Reference to other sections and/or guidelines of the manufacturer.
Disposal instructions
2 Intended use
The profi-air 180 flat connection box is an extension of electric connection options for the profi-air 180 flat ventila-
3 Structure
The profi-air connection box consists of a control board with various inputs and outputs. The control board is incorporat-
4 Scope of delivery
n Connection box incl. 4 PG threaded
connectors
n Approx. 2.5 m of connection cable
wired / with RJ25 connector plug to connect to the mainboard of the profi-air 180 flat ventilation unit.
tion unit. It is connected directly to the mainboard of the ventilation unit.
ed into a plastic housing which is installed near the ventilation unit.
n USB cable (exclusively for the fac-
tory customer service for firmware updates)
n Installation and operating instruc-
tions
MBA profi-air 180 flat connection box
FRÄNKISCHE