FRÄNKISCHE profi-air 180/300 Remote Control Manual

Wireless remote control for profi-air
®
180 / 300 sensor
DRAINAGE SYSTEMS ELECTRICAL SYSTEMS
BUILDING TECHNOLOGY
INDUSTRIAL PRODUCTS
Table of contents
1 General
1.1 Introduction 3
1.2 Safety 3
1.3 Symbols used 3
1.4 Intended use 4
1.5 Transport and unpacking 4
1.6 Checking the scope of delivery 4
1.7 Overview of functions 4
2 Layout of the wireless remote control
2.1 Front 5
2.2 Back 5
3 Putting the wireless remote control into operation
3.1 Synchronisation 6
3.2 Multiple wireless remote controls 6
4 Display overview 7
5 Navigation button and keystroke combinations
5.1 Navigation button 8
5.2 Keystroke combinations 8
6 User menu
6.1 “Operating modes” display field 9
6.2 “Operating data” display field 11
6.3 “Info line” display field 12
6.4 “Ventilation mode” display field 13
7 Fitter menu 14
7.1 SW menu item 15
7.2 Automatic mode menu item 15
7.3 Fan menu item 16
7.4 Summer bypass menu item (only with profi-air 300 sensor) 17
7.5 Target values and setting ranges 18
7.6 Reset to factory settings 18
8 Error codes 19
9 Weekly programs 20
Weekly program P1 20 Weekly program P2 20 Weekly program P3 20 Weekly program P4 21 Weekly program P5 21 Weekly program P6 21 Weekly program P7 22 Weekly program P8 22 Weekly program P9 22 Weekly program P10 23 Weekly program P11 23 Weekly program P12 23
2
OI profi-air FB 180 / 300 sensor
FRÄNKISCHE
1 General
The wireless remote control has been developed specifically for demanding operators of profi-air 180 / 300 sensor ventilation units who emphasise innovative opera­tion.
1.1 Introduction
The operating instructions will help you to operate the wireless remote control ideally. We therefore recom­mend reading these operating instructions carefully. Keep these operating instructions during the entire live of the ventilation unit
1.2 Safety
When used as intended, the device is safe and reliable to operate. Its construction and design are state of the art and comply with all the rele-
Non-authorised changes or modifications of the wireless remote control are forbidden.
The remote control has a wireless connection to the control board of the ventilation unit. The range of this control unit inside a building (through walls and light ceiling structures) is up to 30 m.
since they also serve as reference for ser vice and maintenance work and thus guarantee smooth and efficient operation. Considerable care was taken when preparing these instructions. How­ever, no legal claim whatsoever can
vant DIN / VDE regulations and safe­ty provisions. All safety regulations, warnings and notes of these operat­ing instructions have to be
be derived therefrom. We also reserve the right to make alterations to these instructions at any time and without notice.
observed; non-observance might result in personal injury or damage to profi-air 180 / 300 sensor.
1.3 Symbols used
Risk of personal injury
Risk of:
n damage to equipment n errors while operating the device if the instructions are not followed n other material damage
Additional notes
Reference to other sections and/or guidelines of the manufacturer.
Disposal instructions
OI profi-air FB 180 / 300 sensor
3FRÄNKISCHE
1 General
1.4 Intended use
The wireless remote control must only be used to operate profi-air 180 / 300 sensor ventilation
units and is only suited for domestic use inside closed and frost-protected rooms.
1.5 Transport and unpacking
Please handle the profi-air wireless remote control with utmost care during transport and unpacking.
1.6 Checking the scope of delivery
If the delivered wireless remote control has any damage or incom­pleteness, please get in touch with
The scope of delivery includes:
the supplier immediately.
n wireless remote control n 2 x batteries 1.5 V AAA n USB cable for optional power supply n operating instructions
1.7 Overview of functions
The wireless remote control features the following functions:
n automatic demand control depending on relative humidity n manual operation n weekly autotimer according to stored weekly programs (P1 to P12) n holiday mode n night setback n temperature control – summer bypass (only with profi-air 300 sensor) n setting of the time interval for filter exchange
The following can be displayed on the remote control:
n ventilation mode n fresh air, supply air, extract air and room temperature n humidity in the extract air channel n time left until filter replacement n error code and alarm signal
4
OI profi-air FB 180 / 300 sensor
FRÄNKISCHE
2 Layout of the wireless remote control
2.1 Fr ont
2.2 Back
Display
Fastening points
Open battery compartment
Navigation button
Optional USB connection
OI profi-air FB 180 / 300 sensor
5FRÄNKISCHE
3 Putting the wireless remote control into operation
3.1 Synchronisation
The remote control and the ventilation unit must be synchronised in order to be able to communicate. This requires the following steps:
Step Procedure
Inter rupt power supply o f the ventilat ion unit.
1
Open the bat tery comp artment on t he back of the remote c ontrol and in sert the inc luded bat teries 2 x 1.5 V AAA) .
2
If you wan t to establi sh permanent powe r supply, conne ct the inclu ded USB cable .
3
The port for t he mini USB connector is on the back of the wir eless remo te control un der the battery cover.
Re- connect power supply of the ventilation unit. Wit hin the next 6 0 seconds, t he wireless remote control an d the
4
ventil ation unit tr y to establish a connec tion, afte r which the unit's dat a is displaye d on the display.
If synchronisation does not work at the first attempt (error code E13), either the distance to the control board of the ventilation unit is too big or the wireless remote control has been synchronised with another ventilation unit before. You must reset the wireless remote control in this case. Push and hold the “LEF T” button for approx. 10 seconds until all symbols on the display are flashing. The wireless remote control can now be synchronised again.
3.2 Multiple wireless remote controls
Up to five wireless remote controls can be connected to a ventilation unit. All connected wireless remote
6
OI profi-air FB 180 / 300 sensor
controls are equal, meaning that always the latest respective change is applied.
FRÄNKISCHE
4 Display overview
Operating modes
Operating data
Info line Ventilation mode Navigation buttonTime/day
The following table provides a short description of the different symbols and buttons of the wireless remote control.
The wireless remote control features a power saving func tion which switches the display off between 11:00 pm and 07: 00 am. You can activate the illumination by pushing any but ton.
Display fields Function
Automatic mode / demand co ntrol
Manual operation
Operating mode
Weekly autotimer
Holiday mode
Night setback
Time/day Use the c lock to set th e weekly aut otimer and night setback .
Alarm (error code)
Info lin e
Ventilation mode The four oval fi elds displa y the ventilat ion mode. The m ore fields are fill ed, the higher t he ventilation mode.
Navigation button
Operating data
Use this button to se lect indiv idual menu items from the us er menu and to increase or reduce t arget value s.
The followin g information can be displ ayed:
n filter replacement n room temperature n temperature of supply/extract air n fresh air temperature n relative ex tract air hu midity n heat recovery / summer bypas s
Infor mation on various fun ctions or programs
Low battery status
OI profi-air FB 180 / 300 sensor
7FRÄNKISCHE
5 Navigation button and keystroke combinations
The following table provides an overview of the functions of the navigation button and the keystroke combinations.
5.1 Navigation button
Button Function
Push th e “CENTER” but ton to star t the user menu, sele ct a menu item o r confirm a se tting.
Push th e “LEFT” and “RIGHT” bu ttons to switch b etween the different menu items o r to switch the ventilation mode in to manual mode .
Push th e “UP” and “DOWN” buttons to s witch bet ween
5.2 Keystroke combinations
Button Function
Push an d hold the “CENTER” but ton for approx. 3 sec onds.
Takes you back to the star t page from any menu item.
Push an d hold the “DOWN” but ton for approx . 5 seconds.
Acti vates/ deactiva tes manual summer by pass (only w ith profi- air 300 sens or) for 6 hours .
Push an d hold the “RIGHT” but ton for approx. 10 sec onds.
Activates/deactivate s the installation mode.
Push an d hold the “CENTER” and “UP ” buttons for appr ox. 10 seconds.
Resets all settings and target values to fa ctory set tings (onl y possible in acti vated installation mod e).
Push an d hold the “LEFT” but ton for approx . 10 seconds.
Resets the w ireless re mote contro l / ventilatio n unit synchronisa tion.
8
OI profi-air FB 180 / 300 sensor
FRÄNKISCHE
Loading...