Installation, Operation, Service, and Parts Manual
FBCR18 & FBKR18 Series
Gas Rethermalizers
Frymaster, a member of the Commercial Food Equipment Service Association, recommends
using CFESA Certified Technicians.
24-Hour Service Hotline 1-800-551-8633
819-5686
March 2005
NOTICE
IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS ENODIS
EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED
DIRECTLY FROM FRYMASTER/DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS,
AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS
WARRANTY WILL BE VOID. FURTHER, FRYMASTER/DEAN AND ITS AFFILIATES WILL NOT BE
LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH
ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF
ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER.
NOTICE
This appliance is intended for professional use only and is to be operated by qualified
personnel only. A Frymaster/DEAN Factory Authorized Service Center (FASC) or other qualified
professional should perform installation, maintenance, and repairs. Installation, maintenance,
or repairs by unqualified personnel may void the manufacturer’s warranty. See Chapter 1 of
this manual for definitions of qualified personnel.
NOTICE
This equipment must be installed in accordance with the appropriate national and local codes of
the country and/or region in which the appliance is installed. See NATIONAL CODE
REQUIREMENTS in Chapter 2 of this manual for specifics.
NOTICE TO U.S. CUSTOMERS
This equipment is to be installed in compliance with the basic plumbing code of the Building
Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation
Manual of the U.S. Food and Drug Administration.
NOTICE
Drawings and photos used in this manual are intended to illustrate operational, cleaning and
technical procedures and may not conform to onsite management operational procedures.
NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS
U.S.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: 1) This device may not cause harmful interference, and 2) This device must accept
any interference received, including interference that may cause undesired operation. While
this device is a verified Class A device, it has been shown to meet the Class B limits.
CANADA
This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set
out by the ICES-003 standard of the Canadian Department of Communications.
Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A
et B prescrites dans la norme NMB-003 edictee par le Ministre des Communcations du Canada.
DANGER
Improper installation, adjustment, maintenance or service, and unauthorized alterations or
modifications can cause property damage, injury, or death. Read the installation, operating,
and service instructions thoroughly before installing or servicing this equipment. Only qualified
service personnel may convert this appliance to use a gas other than that for which it was
originally configured. See Chapter 1 of this manual for definition of qualified service personnel.
FBCR18 & FBKR18 SERIES GAS RETHERMALIZERS
TABLE OF CONTENTS
CHAPTER 1: General Information
1.1 Parts Ordering and Service Information ............................................................................1-1
1.2 Safety Information .............................................................................................................1-1
This manual is applicable to and valid for all FBCR18 and FBKR18 units sold in Englishspeaking countries. Where conflicts exist between instructions and information in this manual
and local or national codes of the country in which the equipment is installed, installation and
operation shall comply with those codes.
This appliance is only for professional use and shall be used by qualified personnel only, as
defined in Section 1.6.
1.2 Parts Ordering and Service Information
In order to assist you as quickly as possible, the Frymaster Factory Authorized Service Center
(FASC) or Service Department representative requires certain information about your equipment.
Most of this information is printed on a data plate affixed to the inside of the door.
Parts orders may be placed directly with your local FASC or distributor. Included with the unit
when shipped from the factory is a list of FASCs. If you do not have access to this list, contact the
Frymaster Technical Service Department at 1-800-551-8633 or 1-318-865-1711.
When ordering parts, the following information is required:
Model Number:
Serial Number:
Gas Type:
Item Part Number:
Quantity Needed:
Service information may be obtained by contacting your local FASC/Distributor. Information may
also be obtained by calling the Frymaster Technical Service Department at 1-800-551-8633 or
1-318-865-1711. When requesting service, please have the following information ready:
Model Number:
Serial Number:
Gas Type:
In addition to the model number, serial number, and gas type, please be prepared to describe the nature of the problem and have ready any other information that you think may be helpful in solving
your problem.
RETAIN AND STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE USE.
1-1
1.3 Safety Information
Before attempting to operate your unit, read the instructions in this manual thoroughly.
Throughout this manual, you will find safety notations enclosed in double-bordered boxes similar to
the one below.
DANGER
DANGER boxes contain information about actions or conditions that may cause or result in injury to personnel, and which may cause damage to your system and/or
cause your system to malfunction.
CAUTION boxes contain information about actions or conditions that may cause or result in a
malfunction of your system.
WARNING boxes contain information about actions or conditions that may cause or result in
damage to your system, and which may cause your system to malfunction.
DANGER boxes contain information about actions or conditions that may cause or result in
injury to personnel, and which may cause damage to your system and/or cause your system to
malfunction.
1.4 Equipment Description
The FBCR18 and FBKR18 Series Gas Rethermalizers are specifically designed to rethermalize
meats, sauces, and other vacuum packaged foods at a safe temperature range that prevents overcooking. They can be configured for either natural or LP (Propane) gas, and their efficient infrared burners deliver 90,000 BTUs (94.9 MJ – 26.4 kW).
The systems feature programmable computer controls and an easy to clean automatically filled
cookpots. The FBKR18 also has a manual-fill switch. Each unit can rethermalize up to 15 lbs. (7kg)
of food an hour.
The rethermalizers are safeguarded against boil-over by a standpipe overflow drain, and come with a
1¼” cookpot drain for fast, clog-free emptying. The unit has a rethermalizing area of 18” x 24”
(457mm x 609mm) and holds 25 gallons (94.6 liters) of water.
1.5 Installation, Operating, and Service Personnel
Operating information for Frymaster equipment has been prepared for use by qualified and/or authorized personnel only, as defined in Section 1.5.
All installation and service on Frymaster equipment must be performed by qualified, certified,
licensed, and or/authorized installation or service personnel, as defined in Section 1.6.
1-2
1.6 Definitions
QUALIFIED AND/OR AUTHORIZED OPERATING PERSONNEL
Qualified/authorized operating personnel are those who have carefully read the information in this
manual and have familiarized themselves with the equipment functions, or who have had previous
experience with the operation of the equipment covered in this manual.
QUALIFIED INSTALLATION PERSONNEL
Qualified installation personnel are individuals, or firms, corporations, or companies which, either in
person or through a representative, are engaged in and are responsible for the installation of electrical and gas appliances. Qualified personnel must be experienced in such work, be familiar with all
electrical precautions involved, and have complied with all requirements of applicable national and
local codes.
QUALIFIED SERVICE PERSONNEL
Qualified service personnel are those that are familiar with Frymaster equipment and who have been
authorized by Frymaster to perform service on Frymaster equipment. All authorized service personnel are required to be equipped with a complete set of service and parts manuals, and to stock a prescribed minimum amount of Frymaster equipment parts.
A list of Frymaster Factory Authorized Service Centers (FASC) was included with the unit when it
was shipped from the factory. Failure to use qualified service personnel will void the Frymaster Warranty on your equipment.
1.7 Shipping Damage Claim Procedure
Your Frymaster equipment was carefully inspected and packed before leaving the factory. The
transportation company assumes full responsibility for safe delivery upon acceptance of the equipment for transport.
What to do if your equipment arrives damaged:
1. File a claim for damages immediately, regardless of the extent of damages.
2. Inspect for and record all visible loss or damage and ensure that this information is noted on
the freight bill or express receipt and is signed by the person making the delivery.
3. Concealed loss or damage that was unnoticed until the equipment was unpacked should be recorded and reported to the freight company or carrier immediately upon discovery. A concealed
damage claim must be submitted within 15 days of the date of delivery. Ensure that the shipping
container is retained for inspection.
FRYMASTER DOES NOT ASSUME RESPONSIBILITY
FOR DAMAGE OR LOSS INCURRED IN TRANSIT.
1-3
FBCR18 & FBKR18 SERIES GAS RETHERMALIZERS
CHAPTER 2: INSTALLATION INSTRUCTIONS
2.1 General Installation Requirements
Qualified, licensed, and/or authorized installation or service personnel, as defined in Section
1.6 of this manual, should perform all installation and service on Frymaster equipment.
Conversion of this appliance from one type of gas to another should only be performed by
qualified, licensed, and/or authorized installation or service personnel as defined in Section 1.6
of this manual.
Failure to use qualified, licensed, and/or authorized installation or service personnel (as
defined in Section 1.6 of this manual) to install, convert to another gas type or otherwise
service this equipment will void the Frymaster warranty and may result in damage to the
equipment or injury to personnel.
Where conflicts exist between instructions and information in this manual and local or
national codes or regulations, installation and operation shall comply with the codes or
regulations in force in the country in which the equipment is installed.
Upon arrival, inspect the rethermalizer carefully for visible or concealed damage. (See Shipping
Damage Claim Procedure in Chapter 1.)
WARNING
Frymaster appliances equipped with legs are for stationary installations. Appliances
fitted with legs must be lifted during movement to avoid damage to the appliance
and bodily injury. For movable installations, optional equipment casters must be
used. Questions? Call 1-800-551-8633.
CLEARANCE AND VENTILATION
DANGER
No structural material on this appliance should be altered or removed to accommodate placement of the appliance under a hood. Questions? Call the Frymaster/Dean
Service Hotline at 1-800-551-8633.
DANGER
This appliance must be installed with sufficient ventilation to prevent the occurrence
of unacceptable concentrations of substances harmful to the health of personnel in
the room in which it is installed.
This equipment must be installed with a 6” (150mm) clearance at both sides and back when installed
adjacent to combustible construction. No clearance is required when installed adjacent to noncombustible construction. A minimum of 24” (600mm) clearance should be provided at the front of the
unit.
2-1
One of the most important considerations of efficient operation is ventilation. Make sure the equipment is installed so that products of combustion are removed efficiently, and that the kitchen ventilation system does not produce drafts that interfere with proper burner operation.
The equipment flue opening must not be placed close to the intake of the exhaust fan, and the flue
must never be extended in a “chimney” fashion. An extended flue will change the combustion characteristics of the equipment, causing longer recovery times. It also frequently causes delayed ignition. To provide the airflow necessary for good combustion and burner operation, the areas surrounding the front, sides, and rear of the unit must be kept clear and unobstructed.
This equipment must be installed in an area with an adequate air supply and adequate ventilation.
For U.S installations, information on construction and installation of ventilating hoods can be found
in NFPA Standard 96. This document can be ordered from the National Fire Protection Association,
Battery March Park, Quincy, MA 02269. For installations in countries other than the U.S., the appropriate regulating authority should be contacted for information related to hood construction and
installation.
DANGER
Do not attach an apron drain to a single rethermalizer. The rethermalizer may
become unstable, tip over, and cause injury to personnel.
NATIONAL CODE REQUIREMENTS
This equipment is to be installed in compliance with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual
of the U.S. Food and Drug Administration.
This equipment is manufactured to use the type of gas specified on the rating plate attached to the
door. Connect equipment stamped “NAT” only to natural gas and that stamped “PRO” only to LP
(Propane) gas.
Installation shall be made with a gas connector that complies with national and local codes. Quick
disconnect devices, if used, shall likewise comply with national and local codes.
ELECTRICAL GROUNDING REQUIREMENTS
DANGER
This appliance is equipped with a three-prong (grounding) plug for your protection
against electrical shock, and must be plugged directly into a properly grounded
three-prong receptacle. Do not cut, remove, or otherwise bypass the grounding
prong on this plug!
DANGER
This appliance requires electrical power for operation. Place the gas control valve in
the OFF position in case of a prolonged power outage. Do not attempt to operate
this appliance during a power outage.
2-2
All electrically operated appliances must be grounded in accordance with all applicable national and
local codes. A wiring diagram is located on the inside of the door. In the United States and Canada,
the electrical supply must be 120VAC, 60 Hz. In other countries, refer to the rating plate on the
inside of the door for proper voltages.
FCC COMPLIANCE
The user is cautioned that any changes or modifications to Frymaster computers not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Frymaster computers have been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. While these devices are verified as Class A devices,
they have been shown to meet the Class B limits. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of the equipment in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his own expense. If necessary,
the user should consult the dealer or an experienced radio and television technician for additional
suggestions.
The user may find the booklet “How to Identify and Resolve Radio-TV Interference Problems” helpful. It is prepared by the Federal Communications Commission and is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4.
2.2 Caster/Leg Installation
Depending upon the specific configuration ordered, your unit may have been shipped without installed casters or legs. If casters or legs are installed, you may skip this section and proceed to Section 2.3, Pre-Connection Preparations.
If your unit requires the installation of casters/legs, install them in accordance with the instructions included in your accessory package.
2.3 Pre-Connection Preparations
DANGER
Do not connect this equipment to the gas supply before completing each step in this
section.
After the unit has been positioned in the area where it will be used, ensure the following has been
accomplished before connecting the unit to the gas supply:
1. Adequate means must be provided to limit the movement of this equipment without depending
upon the gas line connections. If a flexible gas hose is used, a restraining cable must be
connected at all times when the equipment is in use. The restraining cable and installation
instructions are packed with the flexible hose in the accessories box that was shipped with your
unit.
2-3
2. The rethermalizer must be stabilized by installing restraining chains on units equipped with
casters or anchor straps on units equipped with legs. Follow the instructions shipped with the
casters/legs to properly install the chains or straps.
3. Level rethermalizers equipped with legs by screwing out the legs approximately 1 inch then
adjusting them so that the rethermalizer is level.
4. For rethermalizers equipped with casters, there are no built-in leveling devices. The floor where
the rethermalizer is to be installed must be level.
DANGER
Do not attach an apron drain board to this unit. The appliance may become
unstable, tip over, and cause injury. The appliance area must be free and clear of
combustible material at all times.
5. Connect the water hose to the fitting at the rear of the unit.
NOTE 1: The hose comes with a quick-disconnect coupling. The quick disconnect may be attached to the rethermalizer or to the water supply line, or it may be left off entirely, whichever
you prefer. Whichever of the options is chosen, Teflon thread-seal tape or Loctite™ PST56765
or equivalent thread sealer must be used when installing the fittings.
NOTE 2: Either hot or cold water may be connected to the unit. Connecting to hot water will
minimize the amount of time required to bring the unit to boil when filling with fresh water.
However, on FBCR18 units, connecting to hot water will lower the efficiency of the chill feature.
NOTE 3: In order for the water level sensors to work properly, a certain amount of mineral content in necessary in the water. For that reason, purified, deionized, or highly filtered water
should not be used.
4. Connect the desired drain plumbing to the 1¼” drain valve.
5. Test the equipment electrical system by plugging the power cord into a grounded 120VAC outlet
°
and pressing the computer’s ON/OFF button.
-Lo or cycl should appear in the display.
6. Turn the computer off. Verify that the display is blank.
7. Verify that the minimum and maximum incoming gas pressures for the type of gas to be used are
in accordance with the accompanying table.
Incoming Gas Pressures
GasMinimumMaximum
Natural
LP
6" W.C.
1.49 kPa
14.93 mbar
11" W.C.
2.74 kPa
27.37 mbar
14" W.C.
3.48 kPa
34.84 mbar
14" W.C.
3.48 kPa
34.84 mbar
2-4
2.4 Connecting to the Gas Supply
DANGER
Before connecting new pipe to this appliance, the pipe must be blown out thoroughly to remove all foreign material. Foreign material in the burner and gas controls will cause improper and dangerous operation.
DANGER
When pressure-testing incoming gas supply lines, disconnect the appliance from the
gas line if the test pressure will be ½ PSIG (3.45 kPa, 13.84 inches W.C.) or greater to
avoid damage to the appliance’s gas tubes and gas valve(s).
DANGER
All connections must be sealed with a joint compound suitable for the gas being
used and all connections must be tested with a solution of soapy water before lighting any pilots.
Never use matches, candles, or any other ignition source to check for leaks. If gas
odors are detected, shut off the gas supply to the appliance at the main shut-off
valve and immediately contact the local gas company or an authorized service
agency for service.
DANGER
“Dry-firing” your unit will cause damage to the cookpot. Always ensure that water
is in the cookpot before firing the unit.
GAS CONNECTIONS AND PIPE SIZES
The size of the gas supply pipe is very important. If the pipe is too small, the gas pressure at the
burner manifold will be low. This will cause slow recovery and delayed ignition. The incoming gas
supply line should be a minimum of 1½ inches (38mm) ID.
When configured for natural gas, this equipment requires a standard gas pipe size of ¾ inch (19mm)
ID for connections within 20 feet (6m) of the supply line, provided no more than 4 fittings or elbows
are used in the run. For a pipe run over 20 feet (6m), increase the pipe size to 1 inch (25.4mm). For
use with LP (Propane) gas, the next smaller pipe size may be used.
IF IN DOUBT ABOUT THE PIPE SIZE TO BE USED, CONSULT YOUR LOCAL GAS
COMPANY.
1. Connect the equipment to the gas supply line.
When making connections, apply a small amount of Loctitite® PST 56765 or equivalent thread
compound to the male threads only. DO NOT apply the compound to the first two threads. This
will prevent clogging of the burner orifices and control valve.
2-5
2. Open the gas supply to the fryer and check all piping, fittings, and gas connections for leaks. A
soap and water solution should be used for this purpose.
3. Close the drain valve and fill the cookpot with water and boil-out solution to the overflow. Light
the burners and perform the boil-out procedures that are described in the “Start-Up Procedure”
and “Boiling Out the Cookpot” sections in Chapter 3 of this manual.
4. It is suggested that the burner manifold pressure be checked at this time by the local gas company or an authorized service agent. Refer to “Check Burner Manifold Pressure” in Chapter 4 of
this manual for the proper procedure.
2.5 Converting to Another Gas Type
This equipment is configured at the factory for either natural gas or LP (Propane) gas.
If you desire to switch from one type of gas to the other, a gas conversion kit must be installed by a
Factory Authorized Service Center technician.
DANGER
This appliance was configured at the factory for a specific type of gas. Converting
from one type of gas to another requires the installation of specific gas-conversion
components.
Switching to a different type of gas without installing the proper conversion kit may
result in fire or explosion! NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY
FOR WHICH IT IS NOT CONFIGURED.
Conversion of this appliance from one type of gas to another should only be
performed by qualified, licensed, and authorized installation or service personnel, as
defined in Section 1.6 of this manual.
2-6
FBCR18 & FBKR18 SERIES GAS RETHERMALIZERS
CHAPTER 3: OPERATING INSTRUCTIONS
3.1 Introduction
WARNING
The on-site supervisor is responsible for ensuring that operators are made aware of
the inherent hazards of operating a gas-fired heated water system, particularly the
aspects of draining and cleaning procedures.
Mechanically, the FBCR18 and FBKR18 rethermalizers are virtually identical. The FBKR18 units
have a manual fill switch in addition to the AutoFill feature.
The primary difference between the two rethermalizers is the controller. Both units use modified
Computer Magic III (CM III) computers. Although the computers are very similar in appearance
(and to standard CM III computers), they are not interchangeable.
3.2 FBCR18 Series Computer
This computer has 12 programmable product buttons and a “chill” switch. The chill switch shuts
off the burners, but does not turn off the computer. This allows unused product to be quickly
cooled before being returned to a refrigerator or freezer.
The product buttons are multi-functional. In the programming mode, each button can be
programmed for a distinct rethermalizing time. In the rethermalizing mode, pressing a button
initiates a specific timed countdown.
1
556
324
1
1 LED Displays 4 Power Switch
2 Chill Switch 5 Product Buttons
3 Temperature Check/Program Lock 6 Program Mode Switch
FBCR18 Series Computer
3-1
PROGRAMMING THE FBCR18 SERIES COMPUTER
1. Turn the computer on by pressing the Power switch.
2. Press the Program Mode switch. CodE appears in the left display. Press, in sequence,
product buttons 1, 6, 5, and 10. (Press switch again to exit the programming mode.)
NOTE 1: The programming mode is not available while the computer is rethermalizing; the
display will flash BUSY.
NOTE 2: To toggle between Fahrenheit and Celsius temperature display, press the Program
Mode switch, then enter the code 1 6 5 8 by pressing the corresponding product buttons.
Next, press the Temperature Check/Program Lock switch to lock in the new display option.
3. SP- is displayed in the left window and the setpoint in the right. Use the product buttons to
change the temperature up to 205°F (96°C). For example, pressing 1, 9, and 5 programs the
setpoint for 195°. When the correct setpoint is displayed, press the Program Mode switch.
4. SELP (Select Product) appears in the display and the LEDs in the product buttons blink. Press
any of the product buttons to select it for programming.
5. PULL appears in the display. Press the product buttons to enter the desired heating time in
minutes and seconds. Press the Program Mode switch to lock it in.
6. SELP again appears in the display. To program the heating time for another product, press the
product button to be associated with it and repeat Step 5.
7. Press the Program Lock switch to exit the programming mode.
PERATING THE FBCR18 SERIES RETHERMALIZER
O
1. Press the Power
switch. The AutoFill feature will activate if the water level is below the
upper water level sensor.
2. CYCL appears in the display and the unit enters a burner on/off cycle until the water in the
cookpot reaches 180°F (82°C). At that time, the display changes to -Lo- and the burners fire
continuously. When the water in the cookpot is within 3°F of setpoint, the display changes to
four dashes (- - - -), indicating that the unit is ready for use. NOTE: To view the water
temperature, press the Temperature Check
button once. Press the button twice to display the
setpoint.
3. After the four dashes appear in the display, place the product basket in the cookpot and press
the corresponding product button. The display counts down the heating time. The display
changes to PULL. The small LED in the product button blinks and an alarm sounds to alert you
to remove the product. Press the button to silence the alarm.
SING THE FBCR18 CHILL FEATURE
U
3-2
If you rethermalize more food than you use, use the chill feature to quickly reduce the temperature
of the food before refrigerating or freezing.
1. Press the Chill Mode switch to de-energize the heating elements.
2. Open the drain valve and drain most of the hot water. The AutoFill will refill the cookpot with
cold water. If desired, add ice to the cookpot to accelerate the cooling process.
3. Remove the product bags when cooled and return them to the refrigerator or freezer.
FBCR18 TEMPERATURE DISPLAY OPTIONS
NOTE: To enter the prgramming mode, press the Program Mode switch. When the display
reads CodE:
Enter 1, 6, 5, 1 to toggle constant temperature display on and off. NOTE: When in
constant temperature display mode, the countdown time will not be displayed.
Enter 1, 6, 5, 8 to toggle between Fahrenheit and Celsius temperature display.
FBCR18 COMPUTER DISPLAY MESSAGES
SELP – Prompts you to select a product button for programming.
CodE – Prompts you to enter a sequence of numbers to change functions.
CYCL – Indicates the rethermalizer is in the burner on/off cycle mode.
-HI- – Indicates the water temperature is more than 3°F above setpoint.
-Lo- – Indicates that the water temperature is more than 3°F below setpoint.
- - - - (four dashes) – Indicates the water temperature is within the proper rethermalizing
range (i.e., within ±3°F of setpoint).
HELP – Indicates a heating problem. Call your local Frymaster Factory Authorized Service
Center or the 24-Hour Hotline (1-800-551-8633).
Prob - Indicates a problem in the temperature control circuits. Call your local Frymaster
Factory Authorized Service Center or the 24-Hour Hotline (1-800-551-8633).
3.3 FBKR18 Series Computer
This computer has 10 programmable product buttons, a Simmer Mode switch, and a Boil Mode
switch. The computer also has two Power switches; press either switch to turn the unit on and off.
The product buttons are multi-functional. In the programming mode, each button can be
programmed for a distinct rethermalizing time. In the rethermalizing mode, pressing a button
initiates a timed countdown of a specific product.
3-3
Pressing the Boil Mode (L) switch overrides the programmed setpoint and the cookpot temperature
rises to boiling at 212°F (100°C). When the unit is in boil mode, boiL appears in both LED
displays. The unit remains in boil mode until the Simmer Mode switch is pressed or the unit is
turned off.
Pressing the Simmer Mode (R) switch causes the cookpot temperature to be maintained at the
programmed setpoint. If the cookpot temperature is above the setpoint, °-HI is displayed in both
LED widows. If the cookpot temperature is below the setpoint, °-Lo is displayed. Four dashes
(- - - -) are displayed if the temperature is within 11°F (6°C) of setpoint.
1
54
67
FBKR18 Series Computer
1 LED Displays 5 Boil Mode Switch
2 Power Switches 6 Product Buttons 1 through 5
3 Temperature Check/Program Lock 7 Product Buttons 6 through 10
4 Program Mode Switch 8 Simmer Mode Switch
PROGRAMMING THE FBKR18 SERIES COMPUTER
322
1
8
CAUTION
It is recommended that the simmer setpoint and the heat/stir times for all 10
products be programmed before the unit is first used in a rethermalizing cycle.
The simmer setpoint and product rethermalizing times are programmed at the factory. These are
test settings not default settings. You must program the unit for your own particular products.
Program the setpoint
and all product rethermalizing times as follows:
1. Turn the computer on by pressing the Power
switch.
2. Enter the programming mode by pressing the Program Mode
switch. CodE appears in the
left display. Press the switch again to exit the programming mode.
3-4