Contents
1 Release history ........................................................................................................................................ 3
2 General information ................................................................................................................................ 3
3 Preparing Stand Up HW10 for conversion .............................................................................................. 4
3.1 Overview of existing system before conversion: ...................................................................................... 4
3.2 Removing connection plate HW10 ........................................................................................................... 5
3.3 Preparing connection plate HW11 for later installation ........................................................................... 6
3.4 Lower connection plate - replacing the pin assignment LABEL: ............................................................... 8
3.5 Preparing the HP distributor mains cable 230 V for later installation ...................................................... 9
3.6 Removing the Power Cube Box/cable ..................................................................................................... 10
4 Converting Stand Up HW10 to HW11 ................................................................................................... 11
4.1 Power Cube Box mounting + earthing cable: .......................................................................................... 11
4.2 New connection plate for HW11 mounting: ........................................................................................... 11
4.3 HP power supply unit + 3D glasses power supply unit holder INSIDE: ................................................... 12
4.4 HP distributor mains cable 230 V wiring: ................................................................................................ 13
4.5 Power Cube Box installation: .................................................................................................................. 14
4.6 USB-A touchscreen monitor cable: ......................................................................................................... 15
4.7 Polhemus USB cable: .............................................................................................................................. 16
4.8 Display port to VGA adapter + VGA monitor cable: ................................................................................ 16
4.9 Display port cable to the connection plate for HW11: ........................................................................... 17
4.10 HDMI cable to the connection plate for HW11: ..................................................................................... 18
4.11 AUDIO cable: ........................................................................................................................................... 19
4.12 LocalNet cable: ........................................................................................................................................ 19
4.13 USB-A to USB-C cable from connection plate for HW11: ....................................................................... 20
4.14 RJ45 cable to the connection plate for HW11: ....................................................................................... 21
4.15 Transponder cable: ................................................................................................................................. 22
4.16 Y power distributor cable:....................................................................................................................... 23
4.17 USB DRM dongle extension: ................................................................................................................... 24
4.18 3D glasses adapter holder OUTSIDE: ...................................................................................................... 25
4.19 Applying the "Virtual Welding 2.0" LABEL: ............................................................................................. 25
4.20 Checking the cable + closing the cable conduit: ..................................................................................... 26
4.21 HP VR Reverb G2 glasses package: ......................................................................................................... 27
5 Overview of the system after the conversion: ...................................................................................... 29
6 Starting for the first time after conversion of the device: .................................................................... 30
6.1 Recalibrating the touchscreen device: .................................................................................................... 30
6.2 Function test of the "Left-Right" speaker device .................................................................................... 30
6.3 Function test/calibration of the HP VR Reverb G2 glasses ..................................................................... 31

Installation Instructions - FRONIUS conversion kit
Document: UpgradeKit VirtualWelding Win7_EN.docx
Document number: 42,0426,0428,EN
Version of the template: 7
Change / Description
change / description
Conversion instructions created
Completion and acceptance by Fronius
Amendments according to Fronius
Conversion to device version HW11
Hardware: HW10
System: VW
Glasses: HP Pro
Hardware: HW11
System: VW2.0
Glasses: HP Reverb G2
1 Conversion of Stand Up HW10
1.1 Release history
1.2 General information
Instructions for converting an existing and functioning Stand Up device with version HW10.
The corresponding conversion kit HW10 (FP0023168) must be used for the conversion.
This conversion kit contains all parts for the Stand Up device.
The following parts for the Mobile Case device remain:
MobileCase connection plate with USB-C (FR000338)
1x display port slot plate connector (FR000076)
The conversion must only be carried out by trained specialist personnel.
ATTENTION! The device must be voltage-free before and during the conversion.
It is IMPORTANT that the mains cable is unplugged.

Installation Instructions - FRONIUS conversion kit
Document: UpgradeKit VirtualWelding Win7_EN.docx
Document number: 42,0426,0428,EN
Version of the template: 7
1.3 Preparing Stand Up HW10 for conversion
1.3.1 Overview of existing system before conversion:

Installation Instructions - FRONIUS conversion kit
Document: UpgradeKit VirtualWelding Win7_EN.docx
Document number: 42,0426,0428,EN
Version of the template: 7
Disconnect all connection cables from connection plate
HW10.
With a screwdriver, unscrew the 4x oval-head screws
from connection plate HW10 and remove from the
device.
ATTENTION:
The 4x oval-head screws from connection plate HW10
are required for the later installation of the new
connection plate (FR000339).
1.3.2 Removing connection plate HW10

Installation Instructions - FRONIUS conversion kit
Document: UpgradeKit VirtualWelding Win7_EN.docx
Document number: 42,0426,0428,EN
Version of the template: 7
Remove the following connections from
connection plate HW10:
1x RJ45 Switchcraft coupling
NEW:
1x StandUp connection plate with USB-C
(FR000339)
1x HDMI port (FR000292)
1x DP port cable (FR000293)
1x CABLE USB3.1-C Keystone 0.5 m
(FR000356)
Install all removed connections and new
connections:
1x StandUp connection plate with USB-C
(FR000339)
1x RJ45 Switchcraft coupling
1x HDMI port (FR000292)
1x CABLE USB3.1-C Keystone 0.5 m
(FR000356)
1x DP port cable (FR000293)
ATTENTION:
The DP port cable connector must be
screwed on with the narrow-slanted side at
the bottom.
Otherwise there will not be enough space
for the HP display port connector!
IMPORTANT:
All lettering on the
connecting plugs
should face uniformly
in one direction.
1.3.3 Preparing connection plate HW11 for later installation

Installation Instructions - FRONIUS conversion kit
Document: UpgradeKit VirtualWelding Win7_EN.docx
Document number: 42,0426,0428,EN
Version of the template: 7

Installation Instructions - FRONIUS conversion kit
Document: UpgradeKit VirtualWelding Win7_EN.docx
Document number: 42,0426,0428,EN
Version of the template: 7
Remove the OLD pin assignment LABEL and stick
on the new pin assignment LABEL (FR000121).
1.3.4 Lower connection plate - replacing the pin assignment LABEL:

Installation Instructions - FRONIUS conversion kit
Document: UpgradeKit VirtualWelding Win7_EN.docx
Document number: 42,0426,0428,EN
Version of the template: 7
1x HP mains cable 230 V enclosed in the HP VR Reverb
G2 glasses package!
Remove the earthed plug and strip approx. 10 cm of
insulation.
1x CRIMP RING TERMINAL M4 Q=0.5-1.5 mm
(FR000348)
Strip the insulation from the yellow-green wire cable
and crimp on the CRIMP RING TERMINAL M4.
2x INSULATION SLEEVES RT ISOL. Q=4.75x0.8MM
(FR000353)
Cut 8 cm of blue and brown wire cable and strip the
insulation off all ends for later crimping.
Connect the same colours to one another again with an
insulation sleeve and crimp.
2x INSULATION SLEEVES RT ISOL. Q=4.75x0.81MM
(FR000354)
Attach an insulation sleeve terminal to each of the blue
and brown wire cables and crimp them together.
1.3.5 Preparing the HP distributor mains cable 230 V for later installation
This cable is already included in the conversion kit, just for your information.

Installation Instructions - FRONIUS conversion kit
Document: UpgradeKit VirtualWelding Win7_EN.docx
Document number: 42,0426,0428,EN
Version of the template: 7
Remove the old components:
1x Power Cube Box including C-Box
holder and cables
End result:
Components and cables that remain:
1x all three monitor cables
1x Polhemus power supply unit +
cable
1x LocalNet RS232 converter + cable
1x all three earthing cables
1x mains filter with cable
1x DC 12 V/5 V distributor board
+ VOLTAGE SUPPLY C-Box distributor board cable
2x fans with grid and cable
1x Polhemus Tracking Unit with cable
1x DC/DC converter, complete
1x AUDIO PC board + cable
1x TRANSPONDER + cable
1x complete connection plate, lower
ATTENTION:
Other cables from the HW10 setup
that are reinstalled are listed in the
steps below.
1x short earthing cable
1x old mains filter cable
1x USB-A touchscreen monitor cable
1x USB cable, 1.1 m (Polhemus)
1x VGA monitor cable
1x AUDIO cable
1x null modem cable, 400 mm
1x RJ45 cable Cat6 1.3 m
1x TRANSPONDER cable
1x USB DRM dongle extension
1.3.6 Removing the Power Cube Box/cable

Installation Instructions - FRONIUS conversion kit
Document: UpgradeKit VirtualWelding Win7_EN.docx
Document number: 42,0426,0428,EN
Version of the template: 7
Place 1x C-BOX holder (FR000213) on the fixing
plate and secure in place with 2x countersunk
screws M3x10
Secure + 1x short earthing cable with 1x oval-head
screw 3.5x9.5 to the sheet-metal parts and fix the
other end to the mains filter sheet.
Secure the prepared new connection plate for
HW11 (see point 3.3) with the 4x oval-head
screws from connection plate HW10.
1.4 Converting Stand Up HW10 to HW11
1.4.1 Power Cube Box mounting + earthing cable:
1.4.2 New connection plate for HW11 mounting:

Installation Instructions - FRONIUS conversion kit
Document: UpgradeKit VirtualWelding Win7_EN.docx
Document number: 42,0426,0428,EN
Version of the template: 7
1x 3D glasses power supply unit holder INSIDE
(FR000332)
+1x HP power supply unit enclosed in the HP VR
Reverb G2 glasses package!
Connect the HP power supply unit with the HP
distributor mains cable 230 V, align it and secure
the 3D glasses power supply unit holder INSIDE
(FR000332) over it with 3x oval-head screws
3.5x9.5.
Thread the fixed cable of the HP power supply
unit in curves, sometimes left sometimes right,
along the cable conduit to the strain-relief device.
At the connection plate for HW11, guide the cable
through the hole provided for this purpose.
Will be connected to the 3D glasses adapter later.
1.4.3 HP power supply unit + 3D glasses power supply unit holder INSIDE:

Installation Instructions - FRONIUS conversion kit
Document: UpgradeKit VirtualWelding Win7_EN.docx
Document number: 42,0426,0428,EN
Version of the template: 7
Route 1x HP distributor mains cable 230 V from
the HP power supply unit to the mains filter.
Suspend the earthing cable to the others on the
mains filter plate and fix it in place.
Connect 1x old mains filter cable to the new HP
distributor mains cable 230 V:
Disconnect the insulation sleeves of the old mains
filter cable from the mains filter and connect the
new insulation sleeves instead.
The old insulation sleeves are connected to the
new insulation sleeve terminals of the HP
distributor mains cable 230 V.
Connect the old mains filter cable to the Power
Cube Box (FP0023499).
1.4.4 HP distributor mains cable 230 V wiring:

Installation Instructions - FRONIUS conversion kit
Document: UpgradeKit VirtualWelding Win7_EN.docx
Document number: 42,0426,0428,EN
Version of the template: 7
Place 1x Power Cube Box (FP0023499) on the CBox holder (FR000213) and fix it in place.
1.4.5 Power Cube Box installation:

Installation Instructions - FRONIUS conversion kit
Document: UpgradeKit VirtualWelding Win7_EN.docx
Document number: 42,0426,0428,EN
Version of the template: 7
1x USB-A touchscreen monitor cable
Route the cable from the monitor to the Power
Cube Box (FP0023499) and connect it to the lower
USB-A 2.0 port.
1.4.6 USB-A touchscreen monitor cable:

Installation Instructions - FRONIUS conversion kit
Document: UpgradeKit VirtualWelding Win7_EN.docx
Document number: 42,0426,0428,EN
Version of the template: 7
1x USB cable, 1.1 m
One end is connected to the Polhemus Tracking
Unit, routed to the Power Cube Box (FP0023499)
and plugged into the upper USB-A 2.0 port.
Connect 1x VGA monitor cable with 1x display
port to VGA adapter (FR000345), route to the
Power Cube Box (FP0023499) and connect to the
lower DP connection.
1.4.7 Polhemus USB cable:
1.4.8 Display port to VGA adapter + VGA monitor cable:

Installation Instructions - FRONIUS conversion kit
Document: UpgradeKit VirtualWelding Win7_EN.docx
Document number: 42,0426,0428,EN
Version of the template: 7
1x DP port cable (FR000293)
Route the DP port cable from the already
prepared connection plate for HW11 to the Power
Cube Box (FP0023499) and connect it to the
middle DP connection.
1.4.9 Display port cable to the connection plate for HW11:

Installation Instructions - FRONIUS conversion kit
Document: UpgradeKit VirtualWelding Win7_EN.docx
Document number: 42,0426,0428,EN
Version of the template: 7
1x HDMI CABLE 2 m Black (FR000347)
Connect one end to the Power Cube Box
(FP0023499) at the HDMI connection, route to the
connection plate for HW11 and connect.
1.4.10 HDMI cable to the connection plate for HW11:

Installation Instructions - FRONIUS conversion kit
Document: UpgradeKit VirtualWelding Win7_EN.docx
Document number: 42,0426,0428,EN
Version of the template: 7
1x AUDIO cable
The AUDIO cable leads away from the AUDIO PC
board and is connected to the Power Cube Box
(FP0023499) at the middle AUDIO-IN connection.
1x null modem cable, 400 mm
One end is connected to the LocalNet RS232
converter and the other is connected to the
Power Cube Box (FP0023499) at the COM2
connection.
1.4.11 AUDIO cable:
1.4.12 LocalNet cable: