Fronius TS 4000, TS 5000, TPS 2700, TPS 3200, TPS 4000, TPS 5000 Quick Guide [EN]

TransPuls Synergic TransSynergic Comfort
Setting the wire diameter
Special diameter
2
Specifying the filler metal and shielding gas
Special setting
6
Correcting parameters
- select desired parameter
- correct desired parameter
Arc length correction
Arc-force dynamic correction / pulse correc­tion / arc-force dynamic
Arc voltage
Quick Reference: English
5
Setting the welding power
- select desired parameter
- set desired parameter
Specify sheet thickness
Specify welding current
Specify wire feed speed
Important! In synergic mode, all the remaining parameters are set automatically.
Note! If external system components are connec­ted, some parameters can be modified on those components. The power source control panel is only for display purposes.
3
Setting the mode
2-step mode 4-step mode Special 4-step mode (Aluminium welding start-up) Spot welding Special function
42,0426,0038,EN 01/2022
-
1 6
Text and illustrations were accurate at the time of printing. We reserve the right to make amendments.
Commissioning sequence
Follow operating instructions
Feeder inching
Gas test
Setup/store
Fronius International GmbH, www.fronius.com
4
Selecting the process
MIG/MAG pulse synergic MIG/MAG standard synergic MIG/MAG standard manual Job mode TIG Rod electrode (MMA)
TransPuls Synergic TransSynergic Comfort
MIG/MAG - setup
2-step mode
Starting current Slope final current time - starting current time - end current
MIG/MAG - setup
Special 4-step mode
Starting current Slope final current
MIG/MAG - setup
Spot welding
MIG/MAG - setup WIG - setup
Procedure
or
Gas pre-flow time Gas post-flow time Wire feeder creep Feeder inching speed Burn back correction Hotstart current * Hotstart time * Frequency ** Wirefeed deviation ** Arc length correction Return to factory setting
2nd menu level
Select push-pull unit Cooling unit control Cooling unit watchdog Ignition timeout Arc-break watchdog Wire-end settings Country setting Special 2-step variants Special 4-step variants JobMaster mode select. Welding cct resistance Welding cct inductivity Gas correction ***
Gas - setup
2nd menu level
Cooling unit control Cooling unit watchdog Comfort stop sensitivity Welding cct resistance Welding cct inductivity
Gas pre-flow time Gas post-flow time Gas flushing Gas flow rate ***
Job correction
For details of Job mode
and Job correction, see
operating instructions
Quick Reference: English
Electrode - setup
Hotstart current Hotstart time
2nd menu level
Welding cct resistance Welding cct inductivity Charactaristic selection Anti-stick Break voltage
Exit setup
Exit setup Save job
Spot-welding time
* only for standard synergic process ** only with SynchroPuls option *** only with digital gas control option
Display firmware versions
Power source firmware Wirefeeder firmware Welding database Total welding time
e.g. e.g. e.g. e.g.
Loading...