Transpocket 150/180 TIG
Quick Guide
Safety
Before carrying out any work with the device, ensure that you have read and understood all the documents provided as well as those
available online! This document does not describe all the functions of the device. For a complete description of the device, refer to the
Operating Instructions.
Welding settings
Available welding processes:
MMA welding
Setting values:
Dynamic: 0 - 100 | Factory setting = 20
Welding current: TP 150 = 10 - 150 A /
TP 180 = 10 - 180 A (STICK), 10 - 220 A (TIG)
SoftStart / HotStart function: 30 - 200 % | Factory setting = 130 %
Pulse welding: OFF / 0.5 - 990 Hz | Factory setting = OFF
Operating Instructions
i
MMA welding with Cel electrode
TIG welding
42,0426,0216,EN
https://manuals.fronius.com/
html/4204260207
011-23032022

Accessing the setup menu Changing welding parameters
Setup menu
MMA welding
Parameters for MMA welding
Starting current duration: 0.1 - 1.5 seconds | 0.5 seconds*
Anti-stick: On* / OFF
Start ramp: On* / OFF
Break voltage: 25 - 90 V | 45 V*
Factory setting
Level 2 Setup menu
Welding parameters in the level 2 Setup menu
Software version
Automatic switch-off: 5 - 60 minutes / OFF*
Fuse: 230 V = 10 A, 13 A, 16 A* /
120 V = 15 A, 16 A, 20 A*
Operating time: hours, minutes, seconds
Welding time: hours, minutes, seconds
Setup menu
Cel electrodes
Setup menu
TIG
Parameters for TIG welding
Operating mode: OFF / 2-step* / 4-step
Starting current: 1 - 200 % | 50 %*
Reduced current: 1 - 200 % | 50 %*
Final current: 1 - 100 % | 50%*
Gas post-flow time: 0.2 - 25* seconds
Comfort Stop sensitivity:
TP150 = OFF / 0.6 - 3.5 V | 1.5 V*
TP180 = OFF / 0.6 - 3.5 V | 1.5 V*
Break voltage: 10 - 45 V | 35 V*
Tacking function: OFF* / 0.1 - 5.0 seconds
Factory setting
Level 2 Setup menu
Turn and press the adjusting dial to
select and change parameters.
*factory setting