TPS 270i C
Quick Guide
SAFETY
Before working with the device, ensure that you have read and understood all the documents provided in hard copy and online.
This document only describes the most important functions of the device. For a complete description of the device, refer to the Operating Instructions.
Set the filler metal and shielding gas
Set the welding power
select desired parameter
Open the material selection
Turn and press
to enable the
desired settings
Sheet thickness
Welding current
Wire speed
Special function F1
Set the welding process
Adjust the parameters for correction
select desired parameter
Press to select the desired welding process
Arc length correction
Welding voltage
Pulse/dynamic correction
Special function F2
Set the operating mode
Press to select the desired mode
Text display
Activate / deactivate = press left adjusting dial
Scroll through full text = turn left adjusting dial
Abbreviation Full text
Operating Instructions
i
set desired parameter
Status indicators (light up when the respective function is active)
Arc length stabilizer Spatter Free Ignition
Penetration stabilizer SynchroPulse
,,,EN
-
set desired parameter
https://manuals.fronius.com/
html/4204260206
Voltage Reduction Device

Entering/exiting the Setup menu
Process parameters
Start/End
I-S
AlS
t-S
SL1
SL2
I-E
AlE
t-E
SFI
SFI-HS
W-r
IgC
W-r (man.)
Gas Setup
Gpr Gas pre-flow (0.1)
GPo Gas post-flow (0.5)
Process control
PSt Penetration stabilizer (0.0)
AISt Arc length stabilizer (0.0)
Components
C-C Cooling unit operating mode (auto)
C-t Filter time flow sensor (10)
Fdi Feeder inching speed (10.0)
ito Ignition timeout (off)
STICK
I-S Starting current (150)
Hti Starting current time (0.5)
Eln Characteristic (I-constant)
Ast Anti-stick (on)
Uco Break voltage (90.0)
TIG
Uco Break voltage (14.0)
CSS Comfort-Stop sensitivity (0.8)
Synchropuls
Syn-Puls SynchroPulse (off)
vd Wire speed (5.0)
dFd Delta wire feed (2.0)
F Frequency (3.0)
DC Duty cycle (50)
Al-h Arc correction high (0.0)
Al-l Arc correction low (0.0)
Prozess-Mix
vd Wire speed (1.5)
AlC Arc length correction (0.0)
PDc Pulse/dynamic correction (0.0)
Hptc Upper power time correction (0)
Lptc Lower power time correction (0.0)
Lpc Lower power correction (0.0)
Starting current (135)
Start arc length correction (0)
Starting current time (off)
Slope 1 (1.0)
Slope 2 (1.0)
Final current (50)
End arc length correction (0.0)
Final current time (off)
SFI ignition (off)
SFI HotStart (off)
Wire retract (0.0)
Ignition current (manual), (450)
Wire retract (manual), (0.0)
Entering/exiting the Setup menu
R/L-check / alignment
Aligning welding circuit resistance
welding circuit inductivity
Settings
Display
Einh. Units
Norm Standards
UIBS Display brightness setting
F1/F2 Param.
Favorit Favourite key
IP System data
System
CLS Housing lighting setup
FAC Restore factory settings
Web-PW reset Reset website password
Information IM-V. / SWV / IP
Operating
mode setup
Language
cs, de, en, etc.
(Values/entries in brackets show the factory setting)
User-defined parameters for F1
and F2
S4T / iJob
Activating/deactivating the key lock
Text display
Abbreviation Full text
Favourite
The Favourite key can be assigned the Setup parameter or
Setup folder that is currently selected.
Retrieve:
Save:
Delete:
EasyJobs
The EasyJob keys allow up to
5 operating points to be saved.
Specifically, the current weldingrelevant settings are saved.
Retrieve:
Save:
Delete:
F1 / F2 special function parameters
F1 and F2 can be assigned the currently selected setup
parameters.
Retrieve:
Save:
Delete:
Use the
key for F2!