Technical data
Acctiva Easy 1202 1204 1206 2403 6/12 12/24
Selectiva 1002 1004 1006 2003 6/12 1002/2003
Mains voltage [V AC] 100-240 V 100-240 V 100-240 V 100-240 V 240 V 240 V
Mains voltage tolerance +/-15 % +/-15 % +/-15 % +/-15 % +/-15 % +/-15 %
Mains frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Max. open circuit power consumption 1,5 W 1,5 W 1,5 W 1,5 W 1,5 W 1,5 W
Nominal output 18 W 36 W 48 W 48 W 18/24 W 36/43 W
Charging voltage / Test voltage [V DC] 12 V 12 V 12 V 24 V 6/12 V 12/24 V
Arithmetic charging current [A DC]
bei 230 V 1,5 A 3,0 A 4,0 A 2,0 A 3,0/2,0 A 3,0/1,8 A
bei 110 V 0,95 A 1,9 A 2,5 A 1,25 A
R.M.S. current [Aeff. DC] *) 2,0 A 4,0 A 6,0 A 3,0 A 4,0/3,0 A 4,0/2,5 A
Battery capacity Acctiva Easy 1-85 Ah 2-150 Ah 3-200 Ah 1,5-100 Ah 2-135 Ah/ 2-135 Ah/
1,5-100 Ah 1,5-90 Ah
Selectiva 1-85 Ah 2-135 Ah 3-180 Ah 2-100 Ah 2-100 Ah/
1,5-85 Ah
Chargeable cells 6 6 6 12 3/6 6/12
On-time 100 % 100 % 100 % 100 % 100 % 100 %
Charging characteristic IUoU IUoU IUoU IUoU IUoU IUoU
EMV Class EN 61000-6-3 (Class B)
EN 61000-6-1
FCC 15 Class B
Degree of protection **) IP30 IP30 IP30 IP30 IP30 IP30
Operating temperature ***) -20°C to +50°C (-4°F to 122°F)
Storage temperature -25°C to +80°C (-13°F to 176°F)
Length of time before the safety cut-out trips
Acctiva Easy 75 h 75 h 56 h 75 h 29 h 44 h
Selectiva 75 h 75 h 75 h 75 h 75 h
Length of time before the safety cut-out trips: 10 min 10 min
*) R.M.S. current corresponds to the specifications for conventional battery chargers
**)
***) at higher temperatures a drop in performance may occur (derating)
The proper functioning of the charger is tested at 5-85% humidity
Component specification: Climate class B
NOTE! For indoor use only, do not expose the charger to rain or snow
8