Fronius F Series, Robacta-USC-150 Series, Robacta-USC Series Operating Instructions Manual

Page 1
EN
/ Perfect Charging / Perfect Welding / Solar Energy
F series Robacta-USC-X
F series
Page 2
Page 3
Operating instructions
Ultrasonic tray
F series
English
Page 4
General
2 / 37
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
© KKS Ultraschall AG
Contents
1 General ........................................................................... 3
2 Important safety notices .................................................. 3
2.1 Notes on using this manual ............................................. 3
2.2 Safety instructions on using the unit ................................ 3
3 Process-specific notes ..................................................... 5
3.1 Water quality ................................................................... 5
3.2 Permitted cleaning media ................................................ 5
4 Product description .......................................................... 6
4.1 Product features .............................................................. 6
4.2 Function .......................................................................... 6
4.3 Scope of supply ................................ ............................... 6
4.4 Optional accessories ....................................................... 6
4.5 Technical data ................................................................. 6
4.6 Type code ....................................................................... 7
4.7 Structure overview ........................................................... 7
4.8 Components .................................................................... 8
4.9 Control panel ................................................................. 10
4.10 LOGO controller ............................................................ 11
5 Before using for the first time ......................................... 14
5.1 Unpacking and packaging ............................................. 14
5.2 Transport ....................................................................... 14
5.3 Set-up ........................................................................... 14
5.4 Installation ..................................................................... 15
6 Starting up / Starting for the first time ............................ 16
6.1 Inserting the settling tank ............................................... 16
6.2 Switch on at the main switch ......................................... 16
7 Operator input and operation ......................................... 17
7.1 Cleaning workflow ......................................................... 17
7.2 Flow diagram ................................................................. 17
7.3 Changing the settling tank ............................................. 20
8 Maintenance .................................................................. 22
8.1 Maintenance schedule ................................................... 22
8.2 Maintenance and care ................................................... 22
8.3 Service life of the ultrasonic tray .................................... 23
8.4 Repairs and returns ....................................................... 23
8.5 Faults ............................................................................ 24
9 Decommissioning and disposal ..................................... 24
10 Contact .......................................................................... 25
10.1 Fronius International GmbH........................................... 25
10.2 Manufacturer's address ................................................. 25
11 Spare parts .................................................................... 26
11.1 Housing ......................................................................... 26
11.2 Tray insert ................................................................ ..... 27
11.3 Settling tank .................................................................. 28
11.4 Control cabinet .............................................................. 29
11.5 Pneumatic module ......................................................... 30
12 Notes ............................................................................. 31
12.1 Remarks ........................................................................ 31
12.2 Process parameters ...................................................... 32
13 Index ............................................................................. 33
Page 5
General
© KKS Ultraschall AG
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
3 / 37
Before starting for
the first time
Disclaimer
Danger
Warning
Caution
Attention
Proper use
User
14 Declaration of conformity ............................................... 34
1 General
These operating instructions are supplied as standard with the unit. They should be kept within easy reach and remain with the unit if it is sold.
We reserve the right to amend the information in these operating in­structions to take account of technical developments.
2 Important safety notices
Read these operating instructions thoroughly before using, and use this electrical device only as described in the instructions. This manual must be accessible to the operator at all times.
The safety rules applicable in your country must be followed in addi­tion to the instructions in this manual.
The manufacturer accepts no liability for any injury to people or dam­age to the unit or items to be cleaned caused by improper use con­trary to these operating instructions. The owner is responsible for instructing the operators.
2.1 Notes on using this manual
Symbols used in this manual This symbol warns of the risk of injury by electricity.
This symbol warns of the risk of injury by explosion and/or deflagra­tion.
This symbol warns of injury by hot surfaces and liquids. This symbol warns of minor injury and damage to equip-
ment/property.
This indicates supplementary information.
Signal words in this manual
The signal word "Danger" warns of severe injuries with a risk of fatal injury.
The signal word "Warning" warns of severe injuries and damage to the unit and equipment.
The signal word "Caution" warns of minor injuries or damage.
2.2 Safety instructions on using the unit
The signal word "Attention" warns of damage to equipment/property.
This ultrasonic cleaning unit is intended solely for treating objects immersed in cleaning fluids with ultrasound. It is not intended for use in areas with explosive atmospheres caused in any other manner.
The unit must only be operated by trained personnel who must follow these operating instructions.
Page 6
Important safety notices
4 / 37
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
© KKS Ultraschall AG
Checking for damage
Mains connection
Set-up
Avoiding
electrical accidents
Cleaning fluid
Hot surfaces and
liquid
Unit must be empty
when moved
Noise emissions
Sound transmission
by contact
Check the unit and mains cable for damage in transit. Do not start up if you identify any damage.
For safety reasons, only connect the unit to a socket that is correctly earthed. The technical details on the rating plate must be compatible with the local conditions for connection, particularly mains voltage and connected load.
The unit must be set up in a dry location with sufficient ventilation to ensure the removal of cleaning fluid vapours. Keep the set-up area, housing and controls dry. Protect against the ingress of moisture. Do not cover ventilation slots.
Always remove the mains plug when filling, maintaining and servicing the unit, if water in the unit is suspected, in the event of a fault and after use. The unit must only be opened by a qualified electrician.
Only water, osmosis water or deionised water may be used in this unit, otherwise there is a risk of fire and explosion. Combustible liq­uids must never be poured into the tray and used for ultrasound treatment.
Risk of burns and scalds. The unit surfaces, cleaning fluid, cleaning basket and items to be cleaned can become very hot, depending on how long the unit is in use.
Do not move the unit when full - risk of tipping if it encounters an ob­stacle. The cleaning fluid can spill out.
Under certain circumstances, ultrasonic devices can trigger unpleas­ant auditory sensations. Always wear ear defenders if you have to stand in the vicinity of an ultrasonic device that is operated without a cover. We strongly rec­ommend that you wear ear defenders if the unit is operated at 27 kHz with the tray cover open at the same time.
During operation, do not reach into the cleaning fluid or touch parts conducting ultrasound (tray, basket, items to be cleaned, etc.).
Page 7
Process-specific notes
© KKS Ultraschall AG
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
5 / 37
Quality
Description
Utilisation
Untreated water or mains water
Drinking water with a minimum content of minerals such as calcium, magnesium, carbonates, etc.
for general cleaning processes, very good rinsing effect, risk of staining after clean­ing and limescale build-up in the unit
Softened or soft wa­ter
Mains water without calcium and magne­sium ions, but with a large proportion of sodium ions
for general cleaning processes, reduced limescale build-up in the unit
Osmosis water
Softened water from which most of the salts and residual ions have been re­moved
for general cleaning processes, for parts with little staining after drying
Distilled water
Largely free of salts, organic substances and microorganisms. It may, however, still contain small quanti­ties of highly volatile compounds.
for general cleaning processes, for parts with little staining after drying
Deionised water
Osmosis water, in which the residual ions have been fur­ther minimised.
for stain-free parts after drying
3 Process-specific notes
3.1 Water quality
The quality of the water is a significant factor in the cleaning process. We distinguish between the following:
3.2 Permitted cleaning media
Osmosis water  Deionised water  Distilled water
Page 8
Product description
6 / 37
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
© KKS Ultraschall AG
Basic data
Robacta-USC-150-XXXV
Tray filling volume
3.5 litres
Settling tank filling volume
20 litres
External dimensions W/D/H [mm]
600 / 400 / 1300
Mains connection
230 VAC +PE
Ultrasound frequency
Single:
27 kHz
Power consumption
300W
Ultrasound power
150W
Sound density [W/L]
20
Max. air consumption
3500 l/min
Degree of protection
IP 42
4 Product description
4.1 Product features
Ultrasonic tray made from special, highly cavitation-resistant
stainless steel
Housing made from V2A (EN 1.4301, ASTM/AISI 304)
stainless steel
Tray base slopes to improve drainage of the cleaning fluid  Set values and actual values in the switch cabinet are dis-
played on the controller
Level monitoring with visual display to protect against running
dry
4.2 Function
The F series units are cleaning systems that can only be operated in conjunction with a higher-level controller. The ultrasonic cleaning and air shower are started via a communication interface, which also for­wards a Ready signal to the controller. The unit has a settling tank that acts as a water reservoir and dirt trap. When the system is in use, the tray is filled and refilled auto­matically.
4.3 Scope of supply
Ultrasonic cleaning unit  Removable cover  Operating instructions  Settling tank
4.4 Optional accessories
Additional settling tank  Filter cover
4.5 Technical data
Page 9
Product description
© KKS Ultraschall AG
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
7 / 37
Weight [kg]
92
Sound level Lp [dB(A)]
< 80
Types (V)
115 V-T
230V
440 V-T
Mains connection [VAC + PE]
115
230
440
Transformer
Yes
No
Yes
Voltage tolerance [%]
±10
±10
±10
Minimum voltage [V]
104
207
396
Maximum voltage [V]
127
253
484
1
Incoming supply
2
Settling tank
3
Control panel
6 4 7 2 3 8 9 1 10 5 11
4.6 Type code
Robacta-USC-150-230V-T
Robacta-USC = Type  150 = Ultrasound power in W 230 V = Input voltage in VAC T = With transformer (optional)
4.7 Structure overview
Page 10
Product description
8 / 37
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
© KKS Ultraschall AG
4
Ultrasonic tray
5
Instructions: Changing the settling tank
6
Handles
7
Air shower and collecting drawer
8
Circuit diagram
9
Main switch
10
Break-through panels for incoming supply from the side
11
Switch cabinet
1
Incoming voltage as shown on rating plate
2
Communication:
Pin 1 = Enable cleaning Pin 2 = Air shower ON Pin 3 = 0VDC Pin 4 = +24VDC continuous volt­age Pin 5 = Ultrasonic cleaning OK Pin 6 = Earth
3
Incoming air supply:
G ¼, 6 bar, min. Ø 10 mm
1
Settling tank with cascade
2
Quick-release coupling for suction in the settling tank
1 2 3 3 2
1
4.8 Components
4.8.1 Incoming supply
4.8.2 Settling tank
Page 11
Product description
© KKS Ultraschall AG
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
9 / 37
3
Quick-release coupling for drain into settling tank
1
Tray empty level
2
Tray full level
3
Pinch valve
4
Ultrasound elements
5
Ultrasound connector
6
Blow-off station
1
Compressed air connection
2
Drawer with filter
1 2 3 5 6 1 2
4
59
4.8.3 Ultrasonic tray
4.8.4 Blow-off station
Page 12
Product description
10 / 37
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
© KKS Ultraschall AG
1
Ultrasound generator
2
Main switch
3
Fuse
4
24 V DC power supply
5
Controls
6
Controller
7
9-pin D-sub adapter
8
Transformer
9
Transformer circuit breaker
10
Overvoltage protection
1 2 3
4 5 1
2 3 4
5
6
7 8 9
10
4.8.5 Switch cabinet
Items 8 & 9 are only present on types with XXXV-T. Item 10 is only present on type 440 V-T.
4.9 Control panel
Page 13
Product description
© KKS Ultraschall AG
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
11 / 37
1
Changing the settling tank
Illuminated pushbutton for changing the set­tling tank.
When the button is pressed, it starts to flash. The unit opens the pinch valve and drains the tray.
When the button lights up continuously, the process has ended. The door can now be opened and the settling tank can be changed by opening the quick-release couplings.
After changing the settling tank and closing the quick-release couplings, press the button for >3 seconds.
The unit will then pump water back into the tray. Once the level is reached, the DEGAS process starts, and production can be started.
The duration of the DEGAS process is set using LOGO.
2
Settling tank level
The indicator lamp lights up when the level in the settling tank is too low.
3
Tray level
The indicator lamp lights up when the level in the tray is too low.
4
Compressed air fault
The indicator lamp lights up when there is no compressed air available.
5
Ultrasound fault
The indicator lamp lights up when the ultra­sound generator signals a fault.
K K S - R o b a c t a - U S C
W e 0 5 : 4 7 T o t a l 0 h 0 m U S 0 h 0
m
Display: Welcome screen
Use the arrow buttons () to change the screen
P a s s w o r t 0
V
1
.
0
Degas
Start screen
Setting the process
parameters
Degassing of the water in the unit
4.10 LOGO controller
Page 14
Product description
12 / 37
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
© KKS Ultraschall AG
M o 1 0 : 2 9 2 0 0 9 - 0 2 - 1 6
Move the cursor down several times until the date appears, then press <ESC>.
S t o p P a r a m S e t z e
n
M e l d g K o n f i
g
E i n s t e l l u n
g
Move cursor down to Einstellungen (Set- tings) <OK>
U h r . .
L C D . .
M e n ü s p r a c h e
Cursor on Uhr.. (Time..) <OK>
U h r s t e l l e
n
S / W - Z e i t
S y n c h
Move the cursor to Uhr stellen (Set time). <OK>
U h r S t e l l e n
M 0 1 1 : 4 5
Y Y Y Y - M M - D D 2 0 0 9 - 0 2 - 1 6
U h r s t e l l e
n
S / W - Z e i t
S y n c h
Move the cursor to S/W-Zeit (S/W time). <OK>
E i n
A u s S / W - Z e i t E i n → E U
Move the cursor to Ein (ON) or Aus (OFF). <OK>, <Esc>to exit the menu.
4.10.1 Setting the time
Page 15
Product description
© KKS Ultraschall AG
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
13 / 37
Set the time and date. <OK>, <Esc>to exit the menu.
Page 16
Before using for the first time
14 / 37
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
© KKS Ultraschall AG
Danger of electric shock caused by the ingress of liquid. Protect the unit to prevent the ingress of moisture. The inside of this unit is protected against dripping water from outside, but the set-up area and the housing should be kept dry to prevent electrical accidents and damage to the unit.
Checking for damage
in transit
Set-up area
DANGER
Ambient conditions
Important!
5 Before using for the first time
5.1 Unpacking and packaging
If possible, retain the packaging for servicing purposes. Disposal must be carried out in accordance with the applicable disposal direc­tives.
Before using for the first time, check the unit for possible damage in transit. If any damage is identified, the unit must not be started up. Contact your supplier and the carrier.
To operate the unit, place it on a solid, flat and dry surface.
The following requirements must be met in order to operate this unit safely:
Permitted ambient temperature during operation:
+5°C to +45°C
Permitted relative humidity during operation: max. 80% Permitted change in temperature between the area around the
unit and the liquid in the bath: Non-dewing, i.e. no condensate forming on the unit surfaces.
For internal operation only
5.2 Transport
The tray may be suspended from a crane with 2 belts, as shown be­low. The safe working load for each handle is at least 500 N.
Do not transport the unit while filled.
5.3 Set-up
1. Removing the screws Remove the 4 screws on the side of the unit.
Page 17
Before using for the first time
© KKS Ultraschall AG
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
15 / 37
2. Detaching the base plate
Lift the unit and detach the base plate from the unit.
Note
Connecting the
mains cable
3. Fitting the base plate
The base plate must be fixed to a level, firm and vibration-free surface using 4 bolts.
Different fixings may be required to connect the installation stand to the underlying surface depending on the nature of this surface. The fixings required to connect the base plate to the surface are not sup­plied with the unit. The installer is responsible for selecting the right type of fixing.
4. Fitting the unit
Place the unit on the firmly bolted base plate and screw to­gether with the 4 screws from step 1.
5.4 Installation
5.4.1 Electrical connection
The connection conditions must be as indicated on the rating plate. See also Technical data (sect.4.5, p. 6).
The incoming supply line must be fused with a 30 mA RCD (Residual Current Device) and a 10 A line circuit breaker. Up to 4 units may be connected to the same RCD. RCD = Residual Current Device (FI)
5.4.2 Communication interface
Attach connector X1 as shown in the wiring diagram.
5.4.3 Connecting the compressed air
Connect a 6 bar compressed air line with an external diameter of at least 10 mm to the unit.
For the air consumption, see Technical data (sect.4.5 (page 6)
Page 18
Starting up / Starting for the first time
16 / 37
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
© KKS Ultraschall AG
CAUTION
Checking for leaks
IMPORTANT!
INFORMATION
Checking for leaks
6 Starting up / Starting for the first time
To start up successfully, every step under point 5.4 in section Installa­tion(p.15) must be completed successfully.
Do not switch the unit on unless the settling tank is correctly inserted.
6.1 Inserting the settling tank
The settling tank should be filled with an approved cleaning fluid (sect.2.2, p.3 Cleaning fluid) and then inserted in the unit. You will find information on inserting the settling tank under points 6-9 in sec­tion7.3 Changing the settling tank (page 20).
Check all of the unit's connections for leaks.
6.2 Switch on at the main switch
Turn the main switch to position 1 to switch the unit on.
If all the components are connected correctly and the main switch is switched on, the unit will start to fill the tray.
It is not necessary to press the "Change settling tank" button to fill the tray. This has the advantage that the unit will automatically fill and make itself ready for use after a power failure.
Once the indicator lamps go out, the system is ready for clean­ing.
Check all of the unit's connections for leaks.
Page 19
Operator input and operation
© KKS Ultraschall AG
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
17 / 37
Danger from hot surfaces and cleaning fluid! Ultrasound energy is physically converted into heat. The unit and fluid heat up during ultrasonic operation. Temperatures over 60°C can be reached in continuous operation with the cover in place. Do not reach into the bath. Wear gloves, if necessary, to hold the unit.
Under certain circumstances, ultrasonic devices can trigger unpleas­ant auditory sensations. Always wear ear defenders if you have to stand in the vicinity of an ultrasonic device that is operated without a cover.
After long periods, ultrasound can damage sensitive surfaces, par­ticularly at low cleaning frequency. Make sure you set a suitable treatment time and ultrasound output, particularly with sensitive surfaces. If you are in any doubt, check the progress of the cleaning and con­dition of the material surface in good time.
1
Ultrasound
The ultrasound is switched on and off via the interface by the higher-level controller. +24VDC = ON 0VDC = OFF
2
Ultrasonic cleaning
The robot moves the shielding gas nozzle into the tray and moves the nozzle up and down.
3
Blowing off
The robot moves the shielding gas nozzle into the blow-off station.
4
Blow-off station
The blow-off station is switched on and off via the interface by the higher-level controller. +24VDC = ON 0VDC = OFF
5
Cleaning process is complete
The protective gas nozzle is cleaned and ready for use.
Enable cleaning
Air shower ON
Blow-off
CAUTION
CAUTION
CAUTION
7 Operator input and operation
Please note the following points before starting ultrasonic cleaning:
The user is responsible for checking the cleaning result and checking in good time whether the parts to be cleaned have been damaged during the cleaning process.
7.1 Cleaning workflow
7.2 Flow diagram
Page 20
Operator input and operation
18 / 37
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
© KKS Ultraschall AG
Nozzle position
0 0 1 2 3 2 1 0 4 5 5 4 4 0
Step
1 2 3 4 5 6 7 8 9
10
11
12
13
14
Position 0
Position 1
Position 2
Position 3
Position 4
64
54
7.2.1 Positions
The nozzle is moving The nozzle is over the tray
The nozzle is in the lower tray position
The nozzle is in the upper tray position
The nozzle is over the air shower
Page 21
Operator input and operation
© KKS Ultraschall AG
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
19 / 37
Page 22
Operator input and operation
20 / 37
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
© KKS Ultraschall AG
Moving into the tray
100 mm/s
Movements during cleaning
5-15 mm/s
Moving into the air shower
100-200 mm/s
Moving out of the air shower
5-10 mm/s
1
8 2
Wait until the lamp lights up
continuously
9
3
10
The lamp goes out.
Position 5
58
The nozzle is in the air shower
7.2.2 Speeds
7.2.3 Process information
Steps 4-5 should be repeated 2-3 times  Step 6: the nozzle should be stopped for roughly 3-10 sec-
onds
7.3 Changing the settling tank
Page 23
Operator input and operation
© KKS Ultraschall AG
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
21 / 37
4
11
Done
5
Press 2x
6
7
Click 2x
Page 24
Maintenance
22 / 37
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
© KKS Ultraschall AG
NOTE
The maintenance schedule is for guidance only; the necessary intervals should be specified on the basis of internal guidelines and the relevant working conditions.
Work
Week
Month
Year
Process tray
Check for residues and clean.
2 ×
Settling tank Drain completely, clean and refill.
2 × Blow-off drawer Clean
2 ×
Generator fan Clean
2 ×
Ultrasonic tray Check for any serious cavitation damage.
2 ×
General condition
Check
2 ×
Leaks
Check screw fittings, pipe system, trays, etc.
Visual check
1 ×
Pneumatic installation
Check the entire installation for leaks.
4 ×
Controls and displays
Check condition and functions (displays, pushbuttons, indicator lamps, etc.)
2 ×
Switch cabinet
Check condition and all wiring (strain relief, insulation, etc.)
2 ×
Level switches
(protection against running dry, tray level). Check sensors.
2 ×
Cables and cable guides
Check for damage
1 × Visual check
1 ×
PLC controller Record programs, parameters, timers and passwords
Whenever something is changed and after long stoppages
Always switch off at the main switch before any maintenance or care work.
CAUTION
Electrical
safety
Checking the ultra-
sonic tray for leaks
8 Maintenance
8.1 Maintenance schedule
8.2 Maintenance and care
For reasons of electrical safety, the housing and mains cable should be regularly checked for damage.
If any leaks are identified in the ultrasonic tray, e.g. if unexplained cleaning fluid residues / stains are identified beneath
or on the side of the unit,
Page 25
Maintenance
© KKS Ultraschall AG
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
23 / 37
Danger of electric shock from live parts in the unit.
Always remove the mains plug before opening the unit. The manu­facturer shall accept no liability for damage caused by unauthorised intervention in the unit.
Care of the housing
Cleaning the blow-off
drawer
Repair and mainte-
nance work
The unit must only
be opened by author-
ised trained electri-
cians.
DANGER
immediately inform the dealer or manufacturer of the unit of the leak and the cleaning fluid used. The unit must be returned for inspection and repair, if necessary.
Cleaning fluid residues can be wiped off with a damp cloth depending on the type of soiling.
Regularly check the ventilation slots for obstructions. Use a vacuum cleaner from the outside to clean.
Empty and clean with a vacuum cleaner to remove all traces of resi­dues.
8.3 Service life of the ultrasonic tray
The ultrasonic tray, particularly the surfaces that radiate sound, is generally regarded as a wearing part. The changes to these surfaces that occur over the course of time initially take the form of perceptible grey patches of increased roughness, and then subsequently take the form of abraded material, known as cavitation erosion. A special, highly cavitation-resistant stainless steel is used to delay these signs of wear for as long as possible.
Please note the following points in order to extend the service life: Regularly remove cleaning residues, particularly metal particles
and rust bloom, using a method that will not damage the surface (wiping, rinsing, etc.).
Abrasive particles of treated soiling (e.g. polishing pastes) should
be regularly removed from the cleaning tray (e.g. when the clean­ing fluid is changed).
Always replace the cleaning fluid in good time.
8.4 Repairs and returns
Maintenance and repair work is carried out by Fronius.
Repair and maintenance work that requires the unit to be connected and opened must only be carried out by authorised trained electri­cians.
Always use manufacturer's genuine spare parts. If the unit fails, please contact the supplier or manufacturer. If it has to be returned for repair, please send an accurate description
of the fault with the unit. If there is damage to the tray, e.g. erosion or leak, details of the cleaning agent and substances that were cleaned will be needed in order to process the claim.
Page 26
Decommissioning and disposal
24 / 37
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
© KKS Ultraschall AG
No.
Problem
Check
1
The < Settling tank level > lamp lights up
Is there a settling tank inserted? Is there sufficient fluid in the settling tank? Is the drawer of the settling tank fully closed?
2
The < Tray level > lamp lights up
 If the < Settling tank level > lamp lights up (see 1)  If the < Compressed air fault > lamp lights up (see 3)  Is the air pump working correctly?  Is the pinch valve closed?  Is the tray fill level sufficient? -> Level fault
3
The < Compressed air fault > lamp lights up
Is the compressed air connected and available?
4
The < Ultrasound fault > lamp lights up
 If the < Settling tank level > lamp lights up (see 1)  If the < Tray level > lamp lights up (see 2)  Was the ultrasound audibly perceptible? -> Lamp fault
8.5 Faults
The following unit faults are indicated by indicator lamps on the con­trol panel: The ultrasound will be switched off if any of these faults occur.
9 Decommissioning and disposal
The unit components may be sent for recycling of the electronic parts and metals they contain. The manufacturer will also accept old com­ponents for disposal.
Page 27
Contact
© KKS Ultraschall AG
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
25 / 37
KKS Ultraschall AG
Ultrasound technology and surface finishing
Frauholzring 29 CH-6422 Steinen
Tel. 041 / 833 87 87 Fax 041 / 832 25 50
info@kks-ultraschall.ch www.kks-ultraschall.ch
10 Contact
10.1 Fronius International GmbH
Please contact the Service and Support department if you have any questions or need any information. For faults and to order spare parts, please specify the serial number (on the rating plate).
Fronius dealerships near you.
www.fronius.com
10.2 Manufacturer's address
Page 28
Spare parts
26 / 37
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
© KKS Ultraschall AG
KKS item no.:
Designation
1
103366
Main switch 16A 3L black
2
121680
Sash lock with knurled head and cylinder lock VW E1 black, driver H22 L35
3
121684
Sash lock with knurled head without cylinder lock, driver H22 L35
4
102250
Side fold-down carrying handles
1 3 2
4
11 Spare parts
11.1 Housing
Page 29
Spare parts
© KKS Ultraschall AG
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
27 / 37
KKS item no.
Designation
0
120700
Robacta-USC tray insert, complete
1
121892
Robacta-USC tray level; set
2
114196
Assembly adapter, level sensor KQ
3
100167
Pinch valve, POM/NRLH, 1/2Z
4
121433
NEOMATIC push-on nipple with external thread, type 5964; AG G 1/2
1&2
3 4 0
11.2 Tray insert
Page 30
Spare parts
28 / 37
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
© KKS Ultraschall AG
KKS item no.
Designation
0
120701
Robacta-USC settling tank, intake & drain, complete
1
120708
Robacta-USC storage tank, empty
2
121464
NEOMATIC coupling with hose nozzle, type 5953; for hose ID 16
3
107102
Filter bag / flat bag, IØ=25 mm L=160 mm +/- 3 mm, open at top
KKS item no.
Designation
1
121890
Robacta-USC settling tank level; set
1 3 2
11.3 Settling tank
11.3.1 Settling tank level
Page 31
Spare parts
© KKS Ultraschall AG
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
29 / 37
KKS item no.
Designation
1
121946
FT150TM-R 27kHz remote F series, including mounting plate
2
122518
Logo! 12/24 RC 8Di 4Do relay 10A 0BA8
3
123172
Logo! DM16 24 8Di 8DO transistor 0.3A 0BA2
4
123146
Logo! AM2 AQ 2AO 0-10V 0-20mA 0BA2
5
120680
Power supply unit 120/230VAC 24VDC 5A
6
120696
Line circuit breaker, 1P 3A Characteristic C
7
121093
Optocoupler, input 24VDC output 9-60VDC 100 mA
8
103361
Lamp holder with LED 24VDC red
9
103362
Lamp holder with LED 24VDC white
10
102275
Illuminated pushbutton, transparent
11
102277
Indicator light, red without LED
12
120952
MST isolating transformer, P: 800VA, In: 105-550VAC, Out: 2*115(230VAC) {only present on types with XXXV-T.}
13
120683
Transformer circuit breaker 1.8-2.5A {for type 440 V-T only}
13
122025
Transformer circuit breaker 5.5-8.0A {for type 115 V-T only}
14
122741
Transformer overvoltage protection {for type 440 V-T only}
Please note:!
2-4 6 5
7
9,10
8,11
1
12
13
14
11.4 Control cabinet
The following items have been replaced with newer versions: 103429 has been replaced by 122518 120691 has been replaced by 123172 103433 has been replaced by 123146
The devices with the serial numbers: FXXXXXX0000-FXXXXXX0011 bear the logo: 0BA6, which is no longer used by the supplier. These components are no longer available in all quantities. Individual components can be found, but at a significantly higher price point. It is possible to convert the older models to the new control system. However, only if all three controllers are replaced. The connections are entirely identical.
Page 32
Spare parts
30 / 37
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
© KKS Ultraschall AG
KKS item no.
Designation
0
121496
Robacta-USC pneumatic unit
1
121494
Solenoid valve, VUVG-L10-T32H-AT-Q6-1R8L
2
120671
2/2-way solenoid valve, MS/PTFE, 24VDC, NPT 1/2" bushing UL
3
121956
Compressed air diaphragm pump, PP, Santoprene + PTFE 5 l/min
4
100203
Pressure switch, 0-10 bar, plug-in connection D6, M8 3-pin plug
1
3
2
4
11.5 Pneumatic module
Page 33
Notes
© KKS Ultraschall AG
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
31 / 37
12 Notes
12.1 Remarks
Page 34
Notes
32 / 37
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
© KKS Ultraschall AG
Description of the parts
Cleaning agent
Concen­tration
Tem­perature
Time
12.2 Process parameters
Page 35
Index
© KKS Ultraschall AG
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
33 / 37
13 Index
A
Ambient conditions .............................. 16
B
Blow-off station .................................... 10
C
Changing the settling tank .............. 12, 23
Components ..................................... 9, 18
Connecting the compressed air ............ 17
Control cabinet ..................................... 31
Control panel ........................................ 12
Controller ............................. 6, 11, 13, 20
E
Electrical connection ............................ 17
F
Faults .................................................... 26
Function ................................................. 6
G
General ................................................... 3
I
Incoming supply ..................................... 9
Inserting the settling tank .................... 18
Installation ............................................ 17
M
Optional accessories ...............................6
P
Pneumatic unit ......................................32
Process-specific notes .............................5
Product features .....................................6
R
Repairs ..................................................26
S
Safety notices ...................................... 3, 4
Scope of supply .......................................6
Service life .............................................25
Setting the time ....................................14
Settling tank ...................................... 9, 30
Spare parts ............................................28
Starting for the first time .............. 3, 4, 18
Structure ........................................... 8, 28
Switch cabinet .......................................11
T
Technical data .........................................7
Transport ..............................................16
Tray insert .............................................29
Type code ................................................7
U
Ultrasonic tray ......................................10
Using for the first time ..........................18
Using for the first time ..........................16
Using this manual ...................................3
Main switch .......................... 8, 11, 18, 25
Maintenance .................................... 4, 24
Maintenance schedule ......................... 24
Manufacturer's address ....................... 27
O
Operation ................................... 4, 16, 19
W
Water quality ..........................................5
Workflow ..............................................20
Page 36
Declaration of conformity
34 / 37
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
© KKS Ultraschall AG
We, as the manufacturers of the machine, declare that the machine designated below conforms to the directives and standards listed below.
Directives
2006/42/EG
Machinery Directive
2014/30/EU
Electromagnetic Compatibility Directive
2014/35/EU
Low-Voltage Directive
Standards
EN ISO 12100:2010
Safety of machinery - General principles for design
- Risk assessment and risk reduction
EN 60204-1:2006
Safety of machinery - Electrical equipment of ma­chines - Part 1: General requirements
This declaration shall cease to be valid if the product is modified in any way without our agreement.
Signed in Steinen,
27.02.2018
Place/date:
Robert Gnos, CEO
14 Declaration of conformity
Page 37
Declaration of conformity
© KKS Ultraschall AG
F-Serie Betriebsanleitung_V2.2_EN.docx – 2018-02
35 / 37
FRONIUS INTERNATIONAL GMBH
Froniusplatz 1, A-4600 Wels, Austria
Tel: +43 (0)7242 241-0, Fax: +43 (0)7242 241-3940
E-mail: sales@fronius.com
wvwv.fronius.com
WWN.fronius.com/addresses
At http://vvww.fronius.com/addresses you will find all the addresses
of our sales & service partners and locations
Loading...