Fronius Print PVAFCI-NL (Arc) Installation Instruction [EN]

Page 1
/ Battery Charging Systems / Welding Technology / Solar Electronics
EN-US
PVAFCI-NL PC board
Installation instructions
Inverter for grid-connected photo­voltaic systems
42,0410,1954 001-16052013
Page 2
Page 3
General
EN-US
Safety
WARNING! An electric shock can be fatal. Danger from grid voltage and DC volt-
age from solar modules.
- The connection area should only be opened by a licensed electrician.
- The separate power stage set area should only be disconnected from the connection area after first being disconnected from the grid power.
- The separate power stage set area should only be opened by Fronius-trained service technicians.
- Never work with live wires! Before any connection work, make sure that the inverter's AC and DC wires are not charged.
- In the USA, all electrical installations must be in accordance with the National Electrical Code, ANSI/NFPA 70, and any other codes and regulations appli­cable to the installation site.
- Installations in Canada must comply with the applicable Canadian standards.
Never work with live wires! Before any connection work, make sure that the in­verter's AC and DC wires are not charged.
WARNING! An electric shock can be fatal. Danger from residual voltage from ca­pacitors.
You must wait until the capacitors have discharged. Discharge takes 5 minutes. Use a suitable measuring tool to ensure that the capacitors are discharged.
WARNING! Incorrect operation and work performed incorrectly can cause seri­ous injury and damage! Only qualified staff are authorized to install your inverter and only within the scope of the respective technical regulations. It is essential that you read the "Safety regulations" chapter before commissioning the equip­ment or carrying out service or maintenance work.
ESD Guidelines
NOTE! Requirements for electrical installations may be subject to national stan-
dards and regulations, and these must be followed accordingly.
NOTE! Observe ESD guidelines when handling electronic components and PC boards. This primarily applies to ESD-compatible
- Packaging
- Work surfaces
-Floors
-Seating
- Grounding options
- Handling
No guarantee or warranty claims can be made in respect of any improperly handled elec­tronic component or PC board.
Page 4
Scope of Supply The scope of supply includes:
- PVAFCI-NL PC board
Required tools - TX 20 Torx screwdriver
- TX 25 Torx screwdriver
- Hand torque wrench with TX 20/25 bit insert
Page 5
Replacing the PVAFCI PC board
1
4
2
3
a)
b)
5
EN-US
Preparation
WARNING! An electric shock can be fatal. Danger from grid voltage and DC volt-
age from solar modules. Never work with live wires! Make sure that the AC and DC wires are not charged before you start work on the inverter.
WARNING! An electric shock can be fatal. Danger from residual voltage from ca­pacitors.
You must wait until the capacitors have discharged. Discharge takes 5 minutes. Use a suitable measuring tool to ensure that the capacitors are discharged.
1
AC
1
on
o
ff
If present, switch off the external AC and DC disconnect and lock it off to avoid inad­vertent operation.
OFF
2
CAUTION! An inadequate grounding conductor connection can cause serious in­juries to persons and damage to (or loss of) property. The housing screws provide an adequate grounding conductor connection for the housing ground and should not be replaced under any circumstances by other screws that do not provide a proper grounding conductor connection
2
Page 6
Replacing the
(1)(1)(1)(1) (1)(1)(1)(1)(1)(1)(1)(1)
2
5
4
3
5
2
1
PVAFCI-NL PC board
(2)
(3)
(4)
(5)
Remove screws (1)
1
Remove the sheet metal cover
Disconnect plugs (2), (4) and (5) from
3
the PVAFCI-NL PC board (3))
Remove PVAFCI-NL PC board (3)
4
Insert the new PC board
Connect plugs (2), (4) and (5) to the
6
PVAFCI-NL PC board (3)
Insert the sheet metal cover and fasten
7
with screws (1) tightening torque: 2 Nm / 1.5 ft lb.
Finally...
CAUTION! An inadequate grounding conductor connection can cause serious in-
juries to persons and damage to (or loss of) property. The housing screws provide an adequate grounding conductor connection for the housing ground and should not be replaced under any circumstances by other screws that do not provide a proper grounding conductor connection.
1
Page 7
2
ON
1
on
off
If available, turn on the external AC and DC disconnect.
EN-US
AC
2
NOTE! The IG Brain PC board and the IG Disp PC board must always have the same firmware version. It is therefore necessary to update the inverter firmware after replacing the IG Brain PC board or the IG Disp PC board. The software and operating instructions for Fronius Solar.update can be found at http://www.fronius.com in the Fronius Download Center.
Page 8
Fronius Worldwide - www.fronius.com/addresses
Fronius International GmbH
4600 Wels, Froniusplatz 1, Austria E-Mail: pv@fronius.com http://www.fronius.com
Under http://www.fronius.com/addresses you will find all addresses of our sales branches and partner firms!
Fronius USA LLC Solar Electronics Division 6797 Fronius Drive, Portage, IN 46368 E-Mail: pv-us@fronius.com http://www.fronius-usa.com
Loading...