Fronius Oversizing Fronius CL 36.0 Certificate [EN]

Wels, November 7th 2013
OVERSIZING FRONIUS CL 36.0
Fronius International GmbH
/ Fronius CL 36.0
can be oversized 70% above the rated nameplate capacity without voiding the manufacturer’s warranty, provided that
/ String configuration adheres to the voltage and current window guidelines published in the operation manual / The open circuit voltage of the PV generator does not exceed the maximum input voltage of the inverter under
any circumstances (temperature, irradiance)
/ The maximum DC array short circuit current must not exceed 1,5 times the maximum DC input current of the
inverter
Fronius International GmbH
Division Solar Electronics Froniusplatz 1 A-4600 Wels
Ing. Prok. Martin Hackl Head of Division Solar Electronics