+43 7242 241 0
Available:
Mo - Th: 08:00 - 16:00 h (CET)
Fr: 08:00 - 12:00 h (CET)
Please contact your regional poison center or emergency call!
Neutralizer
42,0510,0385 / 42,0510,0386
Auxiliary for electrolytic cleaning and polishing.
2 Hazard(s) identification
Classification of the substance or mixture
Flammable Liquids 3 H226 Flammable liquid and vapor.
Carcinogenicity 1AH350 May cause cancer.
Additional information:
Label elements
GHS label elements
The product is classified and labeled according to the Globally Harmonized System (GHS).
Hazard pictograms
GHS02
Signal word
Hazard-determining components of labeling:
ethanol
Hazard statements
Flammable liquid and vapor.
GHS08
Danger
For the wording of the hazard categories, see section 16.
(Contd. on page 2)
US
54.0.17
Page 2/14
Safety Data Sheet
acc. to according to GHS Rev. 8 2019 and OSHA HCS
Printing date 04/26/2022Reviewed on 04/26/2022
Trade name:
May cause cancer.
Precautionary statements
Keep away from heat/sparks/open flames/hot surfaces. - No smoking.
Keep container tightly closed.
Ground/bond container and receiving equipment.
Use explosion-proof electrical/ventilating/lighting/equipment.
Use only non-sparking tools.
Take precautionary measures against static discharge.
Wear protective gloves/protective clothing/eye protection/face protection.
If on skin (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower.
IF exposed or concerned: Get medical advice/attention.
Store in a well-ventilated place. Keep cool.
Store locked up.
Dispose of contents/container in accordance with local/regional/national/international regulations.
Classification system:
NFPA ratings (scale 0 - 4)
0
Neutralizer
2
0
Health = 0
Fire = 2
Reactivity = 0
(Contd. of page 1)
HMIS-ratings (scale 0 - 4)
HEALTH
FIRE
REACTIVITY
Other hazards
Results of PBT and vPvB assessment
PBT:
The mixture does not contain PBT substances ≥ 0,1 %.
vPvB:
3 Composition/information on ingredients
Chemical characterization: Mixtures
Description:
Dangerous components:
[% (w/w)]
The mixture does not contain vPvB substances ≥ 0,1 %.
*0
Health = *0
Fire = 2
2
Reactivity = 0
0
Mixture of the substances listed below with nonhazardous additions.
(Contd. on page 3)
US
54.0.17
Page 3/14
Safety Data Sheet
acc. to according to GHS Rev. 8 2019 and OSHA HCS
Printing date 04/26/2022Reviewed on 04/26/2022
Trade name:
Neutralizer
CAS: 64-17-5ethanol
Flammable Liquids 2, H225
Carcinogenicity 1A, H350
Eye Irritation 2A, H319
Specific concentration limit: Eye Irrit. 2; H319: C ≥ 50 %
Eye Irritation 2A, H319; Specific Target Organ Toxicity - Single Exposure
3, H336
CAS: 1336-21-6 ammonia
Skin Corrosion 1B, H314
Specific concentration limit: STOT SE 3; H335: C ≥ 5 %
(Contd. of page 2)
5 - < 10%
1 - < 10%
< 1%
< 0.2%
4 First-aid measures
Description of first aid measures
General information:
In case of discomfort or doubt, seek medical advice.
If unconscious, use a stable lateral position and do not administer anything through mouth.
Immediately remove any clothing soiled by the product.
After inhalation:
Supply fresh air; consult doctor in case of complaints.
After skin contact:
Immediately rinse with water.
Take off contaminated clothing and wash it before reuse.
Seek medical treatment in case of complaints.
After eye contact:
Rinse opened eye for several minutes under running water.
Remove contact lenses, if present and easy to do. Continue rinsing.
Seek medical treatment in case of complaints.
After swallowing:
Rinse mouth.
Do NOT induce vomiting.
Call a doctor immediately.
Most important symptoms and effects, both acute and delayed
No further relevant information available.
Indication of any immediate medical attention and special treatment needed
Depending on the condition of the patients, the doctor must assess the symptoms and the overall general
condition.
(Contd. on page 4)
US
54.0.17
Page 4/14
Safety Data Sheet
acc. to according to GHS Rev. 8 2019 and OSHA HCS
Printing date 04/26/2022Reviewed on 04/26/2022
Trade name:
Neutralizer
(Contd. of page 3)
5 Fire-fighting measures
Extinguishing media
Suitable extinguishing agents:
CO2, extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
For safety reasons unsuitable extinguishing agents:
Water with full jet
Special hazards arising from the substance or mixture
In case of fire, the following can be released:
COx, NO
Personal precautions, protective equipment and emergency procedures
Restricted access to the affected area until cleaning work is completed.
Wear protective equipment. Keep unprotected persons away.
Ensure adequate ventilation
Avoid contact with skin and eyes.
Do not breathe vapour/spray.
Fumes can combine with air to form an explosive mixture.
Keep away from ignition sources
Environmental precautions:
Do not allow to enter sewers/ surface or ground water.
Methods and material for containment and cleaning up:
Absorb with liquid-binding, inert material (sand, diatomite, acid binders, universal binders).
Dispose contaminated material as waste according to item 13.
Ensure adequate ventilation.
Protective Action Criteria for Chemicals
PAC-1:
CAS: 64-17-5ethanol1,800 ppm
CAS: 111-76-22-butoxyethanol60 ppm
CAS: 78-93-3butanone200 ppm
CAS: 1336-21-6 ammonia61 ppm
CAS: 67-63-0propan-2-ol400 ppm
PAC-2:
CAS: 64-17-5ethanol3300* ppm
CAS: 111-76-22-butoxyethanol120 ppm
CAS: 78-93-3butanone2700* ppm
CAS: 1336-21-6 ammonia330 ppm
CAS: 67-63-0propan-2-ol2000* ppm
(Contd. on page 5)
US
54.0.17
Page 5/14
Safety Data Sheet
acc. to according to GHS Rev. 8 2019 and OSHA HCS
Printing date 04/26/2022Reviewed on 04/26/2022
Trade name:
Neutralizer
(Contd. of page 4)
PAC-3:
CAS: 64-17-5ethanol15000* ppm
CAS: 111-76-22-butoxyethanol700 ppm
CAS: 78-93-3butanone4000* ppm
CAS: 1336-21-6 ammonia2,300 ppm
CAS: 67-63-0propan-2-ol12000** ppm
Reference to other sections
See Section 7 for information on safe handling.
See Section 8 for information on personal protection equipment.
See Section 13 for disposal information.
7 Handling and storage
Precautions for safe handling
Ensure good ventilation/exhaustion at the workplace.
Keep receptacles tightly sealed.
Avoid contact with skin and eyes.
Avoid breathing mist/vapours/spray.
Use personal protective equipment as required.
Observe protective measures and safety instructions.
Information about protection against explosions and fires:
Keep ignition sources away - Do not smoke.
Protect against electrostatic charges.
Conditions for safe storage, including any incompatibilities
Storage:
Requirements to be met by storerooms and receptacles:
Store in dry conditions.
Store in a cool location.
Ensure adequate ventilation.
Store in accordance with local/regional/national/international regulations.
Information about storage in one common storage facility:
Not required.
Further information about storage conditions:
Keep receptacle tightly sealed.
Protect from heat and direct sunlight.
Recommended storage temperature:
Storage class:
Specific end use(s)
10
No further relevant information available.
room temperature
8 Exposure controls/personal protection
Control parameters
Components with limit values that require monitoring at the workplace:
The following constituents are the only constituents of the product which have a PEL, TLV or other
recommended exposure limit.
(Contd. on page 6)
US
54.0.17
Loading...
+ 9 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.