Fronius MagicCleaner Stand Alone, MagicCleaner Stand Alone 110 V Operating Instructions/spare Parts List

Page 1
/ Battery Charging Systems / Welding Technology / Solar Electronics
MagicCleaner "Stand Alone"
MagicCleaner "Stand Alone" 110 V
Operating Instructions Spare Parts List
EN
TIG power source (CrNi cleaning)
Page 2
Page 3
Dear Reader
Introduction
Thank you for choosing Fronius - and congratulations on your new, technically high­grade Fronius product! This instruction manual will help you get to know your new machine. Read the manual carefully and you will soon be familiar with all the many great features of your new Fronius product. This really is the best way to get the most out of all the advantages that your machine has to offer.
Please also take special note of the safety rules - and observe them! In this way, you will help to ensure more safety at your product location. And of course, if you treat your product carefully, this definitely helps to prolong its enduring quality and reliability - things which are both essential prerequisites for getting outstanding results.
EN
ud_fr_st_et_00493 01/2012
Page 4
Page 5
Safety rules
DANGER!
WARNING!
CAUTION!
NOTE!
“DANGER!” indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury. This signal word is to be limited to the most extreme situations. This signal word is not used for property damage hazards unless personal injury risk appropriate to this level is also involved.
“WARNING!” indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. This signal word is not used for property damage hazards unless personal injury risk appropriate to this level is also involved.
“CAUTION!” indicates a potentially hazardous situation which, if not avo­ided, may result in minor or moderate injury. It may also be used to alert against unsafe practices that may cause property damage.
“NOTE!” indicates a situation which implies a risk of impaired welding result and damage to the equipment.
EN
Important!
General remarks
“Important!” indicates practical hints and other useful special-information. It
is no signal word for a harmful or dangerous situation.
Whenever you see any of the symbols shown above, you must pay even closer attention to the contents of the manual!
This equipment has been made in accordance with the state of the art and all recognised safety rules. Nevertheless, incorrect operation or misuse may still lead to danger for
- the life and well-being of the operator or of third parties,
- the equipment and other tangible assets belonging to the owner/operator,
- efficient working with the equipment.
All persons involved in any way with starting up, operating, servicing and maintaining the equipment must
- be suitably qualified
- read and follow exactly the instructions given in this manual.
The instruction manual must be kept at the machine location at all times. In addition to the instruction manual, copies of both the generally applicable and the local accident prevention and environmental protection rules must be kept on hand, and of course observed in practice.
All the safety instructions and danger warnings on the machine itself:
- must be kept in a legible condition
- must not be damaged
- must not be removed
- must not be covered, pasted or painted over
I
Page 6
General remarks
(continued)
- must not be removed
- must not be covered, pasted or painted over
It’s your safety that’s at stake!
Utilisation for intended purpose only
Ambient conditions
The machine may only be used for jobs as defined by the “Intended purpose”. Utilisation for any other purpose, or in any other manner, shall be deemed to be "not in accordance with the intended purpose". The manufacturer shall not be liable for any damage resulting from such improper use.
Utilisation in accordance with the “intended purpose” also comprises
- complete reading and following of all the instructions given in this manual
- complete reading and following of all the safety instructions and danger warnings
- performing all stipulated inspection and servicing work.
The machine is designed to be used in industrial and workshop environments. The manufacturer shall not be liable for any damage resulting from use of the machine in residential premises.
Likewise Fronius will accept no liability for defective or faulty work results.
Operation or storage of the machine outside the stipulated range is deemed to be “not in accordance with the intended use”. The manufacturer shall not be liable for any damage resulting herefrom.
Obligations of owner/operator
Temperature range of ambient air:
- when operating: - 10 °C to + 40 °C (14 °F to 104 °F)
- when being transported or stored: - 25 °C to + 55 °C (-13 °F to 131 °F)
Relative atmospheric humidity:
- up to 50 % at 40 °C (104 °F)
- up to 90 % at 20 °C (68 °F)
Ambient air: Free of dust, acids, corrosive gases or substances etc.
Elevation above sea level: Up to 2000 m (6500 ft)
The owner/operator undertakes to ensure that the only persons allowed to work with the machine are persons who
- are familiar with the basic regulations on workplace safety and accident prevention and who have been instructed in how to operate the machine
- have read and understood the sections on “safety rules” and the “war­nings“ contained in this manual, and have confirmed as much with their signatures
- be trained in such a way that meets with the requirements of the work results
Regular checks must be performed to ensure that personnel are still working in a safety-conscious manner.
II
Page 7
Obligations of personnel
Before starting work, all persons to be entrusted with carrying out work with (or on) the machine shall undertake
- to observe the basic regulations on workplace safety and accident prevention
- to read the sections on “safety rules” and the “warnings” contained in this manual, and to sign to confirm that they have understood these and will comply with them.
Before leaving the workplace, personnel must ensure that there is no risk of injury or damage being caused during their absence.
EN
Protection for yourself and other persons
When working with this machine, you are exposed to many different hazards such as:
- irritation and/or cauterization of skin in case of contact with cleaning agent (cleaning electrolyte, brightening electrolyte, electrolyte powder and printing electrolyte)
- danger of serious eye injury in case of contact with cleaning agent
- general hazards when handling chemicals
- electrical hazards from mains and cleaning current
- harmful vapours
Anybody working on the workpiece during cleaning must wear suitable protective clothing with the following characteristics:
- resistant against acids and chemicals
- isolating and dry
- must cover whole body, be undamaged and in good condition
“Protective clothing” also includes:
- wearing a pair of appropriate regulation goggles (with sideguards)
- wearing stout footwear that will also insulate even in wet conditions
- wearing protective gloves (hand protection), impermeable, resistant against acids and chemicals
- wearing protective apron (e.g. when refilling chemicals)
Immediately remove any working garment contaminated with cleaning agent!
III
Page 8
Protection for yourself and other persons
(continued)
- Don’t eat and drink during working
- Keep cleaning agent away from food, drink and fodder
- Wash your hands before breaks and at the end of a working day
Keep other people - especially children, pregnant women and sick persons ­well away from the equipment and the working operation while this is in progress. If there are still any other persons nearby during workinging, you must
- draw their attention to all the dangers
- provide them with suitable protective equipment and/or
- erect suitable protective partitions or curtains.
Instructions for the correct handling of cleaning agents
The following aspects must be observed when handling cleaning agents (cleaning electrolyte, brightening electrolyte, electrolyte powder and printing electrolyte). For more detailed data please refer to the relevant safety data sheets. You will find the current safety data sheets on the Fronius-Homepage under http://www.fronius.com.
First-aid measures
- After inhaling of vapours provide for supply of fresh air. In case of comp­laint see a doctor.
- After contact with skin wash with water and soap and rinse carefully. In case of continued irritation of skin see a doctor.
- After swallowing do not cause vomiting. Rinse mouth and drink a lot of water, see a doctor immediately.
- After contact with eyes rinse eyes several minutes under running water with eyelid open (eye shower) and see a doctor.
Storage / safekeeping
- Use only containers especially approved for cleaning agents
- Keep container closed tightly
- Don’t store together with alkali (lyes) and metals
- Store in a cool and dry place
- Provide for acid-proof floor
- Keep under lock and key and without the reach of children
Other instructions
- Don’t heat to avoid thermal decomposition (development of toxic gases)
- Provide for emergency cooling in case of fire close by
- Avoid contact with eyes, skin and mucous membranes
- Use only in well ventilated areas. In case of insufficient ventilation use respiratory protection
- For diluting always put acid into water - not the other way round!
- Dispose of cleaning agents and/or uncleaned packagings as provided by national regulations. Don’t dispose together with domestic waste!
- Don’t let agent get into drain system, into waters or the ground water (e.g. via the ground).
IV
Page 9
Hazards from mains and clea­ning current
An electric shock can be fatal. Every electric shock is hazardous to life.
Do not touch any live parts, either inside or outside the machine.
Ensure sufficient protection for yourself and for other people by means of a dry base or cover that provides adequate insulation against the ground/frame potential. The base or cover must completely cover the entire area between your body and the ground/frame potential.
All cables and other leads must be firmly attached, undamaged, properly insulated and adequately dimensioned. Immediately replace any loose connections, scorched, damaged or underdimensioned cables or other leads.
Do not loop any cables or other leads around your body or any part of your body.
Have the mains and the machine supply leads checked regularly by a qualified electrician to ensure that the PE (protective earth) conductor is functioning correctly.
Only run the machine on a mains network with a PE conductor, and plugged into a power outlet socket with a protective-conductor contact.
If the machine is run on a mains network without a PE conductor and plugged into a power outlet socket without a protective-conductor contact, this counts as gross negligence and the manufacturer shall not be liable for any resulting damage.
EN
EMC precautions
Wherever necessary, use suitable measures to ensure that the workpiece is sufficiently grounded (earthed).
Switch off any appliances that are not in use.
Before doing any work on the machine, switch it off and unplug it from the mains.
Put up a clearly legible and easy-to-understand warning sign to stop anybody inadvertently plugging the machine back into the mains and switching it back on again.
After opening up the machine:
- discharge any components that may be storing an electrical charge
- ensure that all machine components are electrically dead.
If work needs to be performed on any live parts, there must be a second person on hand to immediately switch off the machine at the main switch in an emergency.
It is the responsibility of the owner/operator to ensure that no electromagnetic interference is caused to electrical and electronic equipment.
If electromagnetic interference is found to be occurring, the owner/operator is obliged to take all necessary measures to prevent this interference.
Examine and evaluate any possible electromagnetic problems that may occur on equipment in the vicinity, and the degree of immunity of this equipment, in accordance with national and international regulations:
- safety features
V
Page 10
EMC precautions
(continued)
- mains, signal and data-transmission leads
- IT and telecoms equipment
- measurement and calibration devices
- the health of persons in the vicinity, e.g. users of heart pacemakers and hearing aids
- users of heart pacemakers must take medical advice before going anywhere near welding equipment or welding workplaces
Electromagnetic fields may cause as yet unknown damage to health.
Ancillary measures for preventing EMC problems:
a) Mains supply
- If electromagnetic interference still occurs, despite the fact that the mains connection is in accordance with the regulations, take additional measures (e.g. use a suitable mains filter).
b) Power supply lines
- Keep these as short as possible
- Arrange them so that they run close together
- Lay them well away from other leads.
c) Equipotential bonding
d) Workpiece grounding (earthing)
- where necessary, run the connection to ground (earth) via suitable capacitors.
Particular danger spots
e) Shielding, where necessary
- Shield other equipment in the vicinity
- Shield the entire welding installation.
Covers and sideguards may only be opened or removed for as long as is absolutely necessary to carry out maintenance and repair work.
While the machine is in use:
- ensure that all the covers are closed and that all the sideguards are properly mounted ...
- ... and that all covers and sideguards are kept closed.
Special regulations apply to rooms at risk from fire and/or explosion. Observe all relevant national and international regulations.
Power sources for use in spaces with increased electrical danger (e.g. boilers) must be identified by the (for “safety”) mark.
If a machine is fitted with a carrying strap or carrying handle, remember that this strap is ONLY to be used for lifting and carrying the machine by hand. The carrying strap is NOT suitable for transporting the machine by crane, fork-lift truck or by any other mechanical hoisting device.
Measurement of pollutant emissions while working with the device revealed values below the admissible mean toxic limit. Nevertheless:
- Provide for sufficient supply of fresh air.
- Keep head away from generated vapours.
- Don’t inhale generated vapours and/or exhaust them from working area by appropriate means.
VI
Page 11
Safety precauti­ons at the instal­lation site and when being transported
A machine that topples over can easily kill someone! For this reason, always place the machine on an even, firm floor in such a way that it stands firmly.
- An angle of inclination of up to 10° is permissible.
Special regulations apply to rooms at risk from fire and/or explosion. Observe all relevant national and international regulations.
By means of internal instructions and checks, ensure that the workplace and the area around it are always kept clean and tidy.
The appliance must only be installed and operated in accordance with the protection type stated on the specifications plate.
When installing the appliance, please ensure a clearance radius of 0.5 m (1.6 ft.) , so that cool air can circulate freely.
When transporting the appliance, please ensure that the valid national and regional guidelines and accident protection regulations are followed. This applies in particular to guidelines in respect of dangers during transportation and carriage.
Before transportation, completely drain any cleaning agent.
Before commissioning and after transportation, a visual check for damage must be carried out. Any damage must be repaired by Fronius-trained ser­vice personnel before commissioning.
EN
Safety precau­tions in normal operation
Only operate the machine if all of its protective features are fully functional. If any of the protective features are not fully functional, this endangers:
- the life and well-being of the operator or other persons
- the equipment and other tangible assets belonging to the owner/operator
- efficient working with the equipment.
Any safety features that are not fully functional must be put right before you switch on the machine.
Never evade safety features and never put safety features out of order.
Before switching on the machine, ensure that nobody can be endangered by your doing so.
- At least once a week, check the machine for any damage that may be visible from the outside, and check that the safety features all function correctly.
- Only Fronius cleaning agent is suitable for use in our machines.
- Do not mix Fronius cleaning agent with other cleaning agents.
- If any damage occurs in cases where other cleaning agents have been used, the manufacturer shall not be liable for any such damage, and all warranty claims shall be null and void.
- Only transport the cleaning agent in closed original containers.
VII
Page 12
Preventive and corrective main­tenance
With parts sourced from other suppliers, there is no certainty that these parts will have been designed and manufactured to cope with the stressing and safety requirements that will be made of them. Use only original spares and wearing parts (this also applies to standard parts).
Do not make any alterations, installations or modifications to the machine without getting permission from the manufacturer first.
Replace immediately any components that are not in perfect condition.
When ordering spare parts, please state the exact designation and the relevant part number, as given in the spare parts list. Please also quote the serial number of your machine.
The device, the sideguards and the mechanical components may be earthed only by means of „Extrude-Tite“ screws.
Safety inspection
Safety markings
The owner/operator is obliged to have a safety inspection performed on the machine at least once every 12 months.
A safety inspection, by a trained and certified electrician, is prescribed:
- after any alterations
- after any modifications or installations of additional components
- following repairs, care and maintenance
- at least every twelve months.
Observe the relevant national and international standards and directives in connection with the safety inspection.
More detailed information on safety inspections and calibration is available from your regional or national Fronius service centre, who will be pleased to provide you with copies of the necessary documents upon request.
Equipment with CE-markings fulfils the basic requirements of the Low­Voltage and Electromagnetic Compatibility Guideline (e.g. relevant product standards according to EN 60 974).
Equipment marked with the CSA-Test Mark fulfils the requirements made in the relevant standards for Canada and the USA.
Copyright
Copyright to this instruction manual remains the property of Fronius Interna­tional GmbH.
The text and illustrations are all technically correct at the time of going to print. The right to effect modifications is reserved. The contents of the instruction manual shall not provide the basis for any claims whatever on the part of the purchaser. If you have any suggestions for improvement, or can point out to us any mistakes which you may have found in the manual, we should be most grateful for your comments.
VIII
Page 13
Table of contents
General Remarks .......................................................................................................................................... 2
Design concept ........................................................................................................................................ 2
Functional sequence................................................................................................................................ 2
Utilization for intended purpose only ....................................................................................................... 3
Setting-up instructions ............................................................................................................................. 3
Transport Requirements .......................................................................................................................... 3
Options..................................................................................................................................................... 3
Mains connection .......................................................................................................................................... 4
MagicCleaner ........................................................................................................................................... 4
MagicCleaner 110 V ................................................................................................................................ 4
Technical data ............................................................................................................................................... 5
MagicCleaner ........................................................................................................................................... 5
MagicCleaner 110 V ................................................................................................................................ 5
Controls, connections and mechanical components .................................................................................... 6
Controls.................................................................................................................................................... 6
Connections and mechanical components .............................................................................................. 7
Operating modes .......................................................................................................................................... 9
Manual cleaning ....................................................................................................................................... 9
Auto cleaning ........................................................................................................................................... 9
Polishing / burnishing............................................................................................................................... 9
Printing ..................................................................................................................................................... 9
EN
Cleaning , polishing / burnishing ................................................................................................................. 10
Preparation ............................................................................................................................................ 10
Fitting a new cleaning cloth on the cleaning electrode ..........................................................................10
Start-up .................................................................................................................................................. 10
Cleaning procedure ................................................................................................................................11
Removal of electrolyte and heavy metal residues ..................................................................................11
Printing, if MagicCleaner is exclusively used for printing............................................................................ 12
Imprinting film for short-term use ........................................................................................................... 12
Preparation ............................................................................................................................................ 12
Mount the printing felt on the cleaning electrode ................................................................................... 12
Start-up .................................................................................................................................................. 13
Printing procedure ................................................................................................................................. 13
Printing, if MagicCleaner is used for cleaning, polishing/burnishing and for printing ................................. 14
Imprinting film for short-term use ........................................................................................................... 14
Preparation ............................................................................................................................................ 14
Mount the printing felt on the cleaning electrode ................................................................................... 14
Start-up .................................................................................................................................................. 15
Printing procedure ................................................................................................................................. 15
Care, maintenance and disposal ................................................................................................................ 16
Every start-up......................................................................................................................................... 16
Weekly ................................................................................................................................................... 16
Every 6 months ...................................................................................................................................... 16
Disposal ................................................................................................................................................. 16
Replacing the cleaning electrode ............................................................................................................... 17
Safety ..................................................................................................................................................... 17
Preparations........................................................................................................................................... 17
Removing the cleaning electrode .......................................................................................................... 17
Fitting the cleaning electrode ................................................................................................................. 18
Spare parts list
Fronius Worldwide
1
Page 14
General Remarks
General Remarks
Design concept
The MagicCleaner CrNi cleaning unit opens up brand-new dimensions in weld finishing. With the aid of processor­controlled current curves and a specially formulated electrolyte, the unit achieves cleaning results of unparalleled quality. The unit’s automatic, exactly controllable electrolyte-dispensing system guarantees a high level of safety and ease of hand­ling. Thanks to its unique cleaning quali­ties, its area of use ranges from craft and trade workshops all the way up to the food-processing and chemical industries.
Fig.1 MagicCleaner „Stand alone“
The unit’s powder-coated sheet-steel housing, shielded controls (in a recess protected by a plastic surround) and its bayonet-latching earth socket are all features designed to prolong its service life. Its shoulder strap makes it easy to carry around, both indoors in the workshop and outdoors on site-erection jobs.
Functional sequence
MICROPROCESSOR
Process control - Fault monitoring
L1
N
Fig. 1 Block diagram of “Stand alone” MagicCleaner
Switched-mode
power supply
Controller for
cleaning current
Inverter
Controller for
electrolyte flow
Fault
indicator
Pump
The mains voltage is regulated to operating voltage via an isolated switched-mode power supply and the adjusted operating current. via a A series-connected inverter transforms the DC voltage into a 50 Hz square-wave voltage and supplies this to the output. Electronic controllers adjust the cleaning current and electrolyte dispensing rate to suit the intended utilisation. The cleaning process as a whole is controlled and monitored by a microprocessor.
2
Page 15
Utilization for intended purpose only
The MagicCleaner is exclusively designed for the electro-chemical cleaning of high­alloy steels. Utilisation for any other purpose, or in any other manner, shall be deemed to be "not in accordance with the intended purpose". The manufacturer shall not be liable for any damage resulting from such improper use.
Setting-up in­structions
Transport Re­quirements
Utilisation in accordance with the “intended purpose” also comprises
- the instructions given in this manual
- performing all stipulated inspection and servicing work.
Open-air operation
In view of the unit’s IP 23 protection rating, it is suitable for outdoor placement and operation. However, the built-in electrical components must be protected from direct wetting such as that caused by external wet-cleaning.
Ambient temperature Important! The temperatures for employment and storage must not fall below the
following values:
- without electrolyte -25°C
- with electrolyte -10°C
The cleaning unit must be positioned well away from such sour-ces of heat as radiators, heating or annealing furnaces, direct hot sunshine etc., which would raise its tempera­ture still further.
NOTE! Before being transported the reservoir must be emptied completely! Otherwise the MagicCleaner would have to be packed and marked as hazar­dous material.
EN
Options MagicCleaner suction device
Fully automatic, portable unit for exhausting the fumes generated by the electro-chemi­cal cleaning process.
Carbon electrode
The high-strength graphite composite cleaning electrode allows to speed up the clea­ning process by 20 - 30 %, depending on the type of metal used.
3
Page 16
Mains connection
MagicCleaner
MagicCleaner 110 V
The “Stand alone” MagicCleaner may be operated as standard on a mains voltage of 230V. Yellow-green lead = protective earth conductor (PE). The other conductors L1 and N are connected to the phase and neutral conductors of the mains plug.
Important! Electrical work, fitting or changing the power plug, may only be carried out by a qualified electrician!
The “Stand alone” MagicCleaner 110 V may be operated as standard on a mains voltage of 100 - 110 V. Yellow-green lead = protective earth conductor (PE). The other conductors L1 and N are connected to the phase and neutral conductors of the mains plug.
4
Page 17
Technical data
MagicCleaner
MagicCleaner 110 V
Unit suitable for use in confined spaces
Mains voltage -15%/+10% ~230 V / 50-60 Hz
Mains fuse 10 A
Apparent power 490 VA
Output current 5 - 20 A
Output voltage 2 - 12 V
Output power 200 W
Open-circuit voltage 17 V
Dispensing rate 0.55 - 2.2 l/h
Cleaning agent capacity 1.5 l
Degree of protection IP 23
Dimension l/b/h 430/180/280 mm
Weight 5 kg
Pollutant emission during operation phosphoric acid (H3PO4) < 0.2 mg/m³ (measured acc. to VDI 2462, part 8) sulphuric acid (H2SO4) < 0.6 mg/m³
Unit suitable for use in confined spaces
Mains voltage -6%/+6% ~100-110 V / 50-60 Hz
Mains fuse 10 A
Apparent power 490 VA
Output current 5 - 20 A
Output voltage 2 - 12 V
Output power 200 W
Open-circuit voltage 17 V
Dispensing rate 0.55 - 2.2 l/h
Cleaning agent capacity 1.5 l
Degree of protection IP 23
Dimension l/b/h 430/180/280 mm
Weight 8,4 kg
Pollutant emission during operation phosphoric acid (H3PO4) < 0.2 mg/m³ (measured acc. to VDI 2462, part 8) sulphuric acid (H2SO4) < 0.6 mg/m³
EN
5
Page 18
Controls, connections and mechanical components
WARNING! Operating the equipment incorrectly can cause serious injury and
damage. Do not use the functions described here until you have read and completely understood all of the following documents:
- these Operating Instructions
- all “Operating Instructions” for the system components, especially the “Safety rules”
General remarks
Controls
(1)
(5)(4)(3)(2)
(10) (9) (8) (7) (6)
Fig.4 Controls
(1) Cleaning-current dial
- Continuous adjustment of cleaning current from 5-20 A
(2) Program switch
- for switching the MagicCleaner from stand-by to the desired operating mode.
(3) LED indicator “Auto-Cleaning“ mode
- lights up when the “Auto-Cleaning“ mode is selected
(4) LED indicator “Manual-Cleaning“ mode
- lights up when the “Manual-Cleaning“ mode is selected
6
Page 19
Controls
(continued)
(5) Dial for electrolyte dispensing rate
- Continuous adjustment of electrolyte dispensing rate from 0.55 - 2.2 l/h
(6) “Elektrolyte dispensing” LED
- lights up when the pump is in operation
Connections and mechanical components
(7) LED “Fault” indicator
- lights up if the unit is overloaded (if the temperature of the power section rea­ches 65°C).
- flashes if short-circuiting occurs between the stylus and earth (e.g. cleaning cloth is defective)
(8) “Stand-by” LED
- lights up when the MagicCleaner is connected to the mains
(9) LED indicator “Printing“ mode
- lights up when the “Printing“ mode is selected
(10) LED indicator “Polishing / Burnishing“ mode
- lights up when the “Polishing / Burnishing“ mode is selected
(11) Handle with cleaning electrode and
cleaning cloth
for creating the electrical and electro­lytic connection between the Magic­Cleaner and the workpiece
(12) Bayonet-latching earth socket
for connecting the earth cable
EN
(12)(11)
Fig. 5 View from front, with cleaning handle
7
Page 20
Connections and mechanical components
(continued)
(13) Storage compartment
for storing the accessories supplied with the unit.
These include:
- 1 pc. safety goggles
- 1 pair of protection gloves
- 10 pcs. spare cleaning cloths
- 1 case of Fronius electrolyte powder
- 1 pc. mixing container 1 l
CAUTION! Danger of injury because of acid and/or acid residues. Don’t keep cleaning liquids, contaminated gloves and used cleaning rags in the storage compartment. Store mixing container in the storage compartment only when cleaned!
(13)
Fig. 6 Rear view, showing accessories
8
Page 21
Operating modes
Manual cleaning “Manual Cleaning” mode serves for removing tarnish discoloration
The Electrolyte is dispensed when the button is pushed on the cleaning handle (polis­hing not possible)
Current curve: AC
EN
Auto cleaning
Polishing / bur­nishing
Printing
“Auto-Cleaning” mode serves for removing tarnish discoloration The electrolyte is automatically dispensed during cleaning. Adjustement of the desired dispensing rate with dial for electrolyte dispensing rate (5). No need to push the button! (Polishing not possible)
Current curve: AC
“Polishing / Burnishing“ mode serves for polishing (burnishing) the workpiece after cleaning The electrolyte is dispensed when the button is pushed on the cleaning handle
Current curve: DC
“Printing” mode serves for electrochemical printing of CrNi parts (e.g. graphics or company logos).
Current curve: AC
9
Page 22
Cleaning , polishing / burnishing
WARNING! O perating the equipment incorrectly can cause serious injury and
damage. Do not use the functions described here until you have read and completely understood all of the following documents:
- these Operating Instructions
- all “Operating Instructions” for the system components, especially the “Safety rules”
- the safey data sheet for the cleaning and brightening electrolyte as well as for Fronius electrolyte powder
General remarks
Preparation
1. Take safety precautions: Put on safety goggles, gloves and protective clothing
2. Switch off the MagicCleaner and disconnect it from the mains supply
3. Undo the screw-cap of the reservoir
4. Only for use of Fronius electrolyte powder: prepare electrolyte powder as cleaning electrolyte a) Fill 1/2 l of clear water into the mixing container included in the scope of supply b) Add complete contents of the case containing Fronius electrolyte powder slowly
to water c) Close mixing container tightly. d) Shake mixing container with water and Fronius electrolyte powder for approx. 1
min. e) Open mixing container and pour in the remaining 1/2 l of water f) Again close mixing container tightly g) Shake mixing container for another 1 min (until Fronius electrolyte powder is
completely dissolved).
5. Fill the reservoir with cleaning or polishing electrolyte up to just under the filler neck. Clean mixing container for preparation of Fronius electrolyte powder, if necessary.
Important! Use only original Fronius cleaning or polishing electrolyte!
6. Replace the screw-cap of the reservoir tightly
7. Make an earth connection between the MagicCleaner and the workpiece
Fitting a new cleaning cloth on the cleaning electrode
Start-up
1. Using your index finger and thumb, pull the clamping plate towards the cleaning handle and turn it 90°
2. Using your thumb, lift the clamping plate on each side at a time and clamp the cleaning cloth in place
3. Turn the clamping plate back 90°
CAUTION! Danger of damage to workpiece and cleaning electrode because of current flow. As soon as the mains cable of the MagicCleaner is connected to the mains, cleaning current may be flowing, if the program switch is positioned accordingly. Deposit handle on insulated surface!
1. Connect up the MagicCleaner to the mains
2. Select the desired operating mode with the program switch (2)
3. Select the cleaning current on dial (1) and the electrolyte dispensing rate on dial (5).
10
Page 23
Cleaning proce­dure
Fig.7 Wet thecleaning cloth with electrolyte
Manual cleaning Auto-cleaning
1. Push the button on the handle to wet sufficiently the stretched cleaning cloth with electrolyte
The first time after the reservoir has been (re)filled, it takes the electrolyte approx. 30 sec to be pumped from the reservoir to the handle
2. Applying gentle pressure, move the cleaning electrode back and forward along the tarnished weld and conti­nuously moisten the cleaning cloth with electrolyte
EN
Removal of electrolyte and heavy metal residues
Fig.8 Cleaning procedure
NOTE: During the cleaning procedure do not dwell on the same spot for too long, as due to the increasing thermal load wear of the cleaning cloth increa­ses significantly! Also ensure that the cleaning cloth is always moistened with sufficient electro­lyte!
Electrochemical cleaning with the MagicCleaner leaves electrolyte and heavy metal residues on the workpiece surface. Such residues may cause deposits on the workpi­ece and affect corrosion resistance!
1. Soak a clean sponge in clean water.
2. Wipe the electrochemically treated surfaces with the wet sponge.
3. Rinse the sponge.
4. Repeat several times.
NOTE! During electrochemical cleaning ensure that no cleaning electrolyte enters into the workpiece cavities. In most cases complete removal of electro­lyte residue from cavities can only be achieved with great difficulty.
11
Page 24
Printing, if MagicCleaner is exclusively used for prin-
WARNING! Operating the equipment incorrectly can cause serious injury and
damage. Do not use the functions described here until you have read and completely understood all of the following documents:
- these Operating Instructions
- all “Operating Instructions” for the system components, especially the “Safety rules”
- the safety data sheet for the printing electrolyte.
ting
General remarks
For this application, we recommend using the “Printing set (4,100,212 - not included in MagicCleaner scope of supply). This set consists of:
- Printing electrolyte 0.5l
- 1 x printing film for doing your own printing
- 10 x printing felts
- 1 x plastic canister
- 1 x plastic case
Imprinting film for short-term use
Preparation
Use a dot matrix printer or a mechanical typewriter for imprinting the film for short-term use.
1. Fix the film to a paper sheet size A4 with adhesive tape
2. Insert paper into printer in a way that the colored film is printed
3. Print text or graphics on the film
4. Remove colored printing film
The printing film can be used for abt 10 printings.
1. Switch off the MagicCleaner disconnect it from the mains
2. Undo the screw-cap of the reservoir
Important! Before pouring the printing electrolyte into the reservoir, this must first be emptied completely! Also, the hosepack and reservoir must be rinsed with clean water!
3. Fill the reservoir with printing electrolyte, up to just under the filler neck
4. Replace the screw-cap of the reservoir tightly
5. Make an earth connection between the MagicCleaner and the workpiece
Mount the prin­ting felt on the
cleaning electro­de
1. Using your index finger and thumb, pull the clamping plate towards the cleaning handle and turn it 90°
2. Using your thumb, lift the clamping plate on each side at a time and clamp the printing-felt in place
3. Turn the clamping plate back 90°
12
Page 25
Start-up
CAUTION! Danger of damage to workpiece and cleaning electrode because of
current flow. As soon as the mains cable of the MagicCleaner is connected to the mains, cleaning current may be flowing, if the program switch is positioned accordingly. Deposit handle on insulated surface!
Printing procedu­re
1. Connect up the MagicCleaner to the mains
2. Select the Printing mode with the program switch (2)
3. Select the cleaning current on dial (1) and set the electrolyte dispensing rate to maximum on dial (5)
4. Fix the printing film to the workpiece with adhesive tape
1. Push the button on the handle to ensure that the printing felt is sufficiently wetted with electrolyte.
The first time after the reservoir has been (re)filled, it takes the electrolyte approx. 30 sec to be pumped from the reservoir to the handle
2. Applying gentle pressure, slowly move the cleaning electrode across the film, 1 - 3 times
Important! When you have finished printing, rinse the printing film thoroughly in water (if the printing electrolyte dries onto the film, this may lead to poor-quality printing results)!
NOTE! If the cleaning electrode touches the workpiece off the edge of the film, this causes black marks on the workpiece!
EN
13
Page 26
Printing, if MagicCleaner is used for cleaning,
WARNING! Operating the equipment incorrectly can cause serious injury and
damage. Do not use the functions described here until you have read and completely understood all of the following documents:
- these Operating Instructions
- all “Operating Instructions” for the system components, especially the “Safety rules”
- the safety data sheet for the cleaning and brightening electrolyte, Fronius electrolyte powder and the printing electrolyte
polishing/burnishing and for printing
General remarks
For this application, we recommend using the “Printing set (4,100,212 - not included in MagicCleaner scope of supply). This set consists of:
- Printing electrolyte 0.5l
- 1 x printing film for doing your own printing
- 10 x printing felts
- 1 x plasic canister
- 1 x plastic case
Imprinting film for short-term use
Preparation
Mount the prin­ting felt on the cleaning electro­de
Use a dot matrix printer or a mechanical typewriter for imprinting the film for short-term use.
1. Fix the film to a paper sheet size A4 with adhesive tape
2. Insert paper into printer in a way that the colored film is printed
3. Print text or graphics on the film
4. Remove colored printing film
The printing film can be used for abt 10 printings.
1. Switch off the MagicCleaner and disconnect it from the mains
2. Pour the printing electrolyte into a plastic canister
3. Remove the cleaning cloth from the cleaning electrode and rinse the electrode well with water
4. Make an earth connection between the MagicCleaner and the workpiece
1. Using your index finger and thumb, pull the clamping plate towards the cleaning handle and turn it 90°
2. Using your thumb, lift the clamping plate on each side at a time and clamp the printing-felt in place
3. Turn the clamping plate back 90°
14
Page 27
Start-up
CAUTION! Danger of damage to workpiece and cleaning electrode because of
current flow. As soon as the mains cable of the MagicCleaner is connected to the mains, cleaning current may be flowing, if the program switch is positioned accordingly. Deposit handle on insulated surface!
Printing procedu­re
1. Connect up the MagicCleaner to the mains
2. Select the “Printing“ mode with the program switch (2)
3. Set the cleaning current to maximum on dial (1) and the electrolyte dispensing rate to minimum on dial (5)
4. Fix the printing film to the workpiece with adhesive plastic tape
1. Dip the cleaning electrode, with the mounted printing felt, into the printing electroly­te until the felt is well wetted.
2. Applying gentle pressure, slowly move the cleaning electrode across the film, 1 - 3 times
Important! When you have finished printing, rinse the printing film thoroughly in water (if the printing electrolyte dries onto the film, this may lead to poor-quality printing results)!
NOTE! If the cleaning electrode touches the workpiece off the edge of the film, this causes black marks on the workpiece!
EN
15
Page 28
WARNING! An electric shock can be fatal. Before opening up the machine:
- shift the mains switch into the "O" position
- unplug the machine from the mains
- put up an easy-to-understand warning sign to stop anybody inadvertently switching it back on again
- using a suitable measuring instrument, check to make sure that electrical­ly charged components (e.g. capacitors) have been discharged
Care, maintenance and disposal
General remarks
Every start-up
Under normal operating conditions the MagicCleaner requires only a minimum of care and maintenance. However, it is indispensable to follow some important points to ensure the operationality of the machine for many years.
- Check mains cable and interconnecting cable for damage
- Check container and pump for leakage
- Check whether the allround distance of 0.5 m (1ft. 8in.) is kept to ensure that the cooling air can easily flow and escape.
NOTE! Furthermore, air inlets and outlets must in no case be covered, not even covered partly.
Weekly
Every 6 months
Disposal
Clean device by means of solvent-free products.
- Dismantle machine side panels and clean machine inside with dry reduced com­pressed air
NOTE! Risk of damage to electronic components. Clean electronic compon­ents from a certain distance only.
- If a lot of dust has accumulated, clean the cooling-air ducts.
Carry out disposal in accordance with the valid national and local regulations.
16
Page 29
Replacing the cleaning electrode
Safety
CAUTION! Risk of damage to the handle and cleaning electrode due to impro-
per replacement of the cleaning electrode. No tools are required when replacing the cleaning electrode. Tighten the cleaning electrode by hand only when screwing it onto the handle!
Preparations 1. Switch off MagicCleaner and disconnect it from the mains
2. Remove cleaning cloth from the cleaning electrode
Removing the cleaning electro­de
2
1. Undo the fixing nut (2)
2. Unscrew the fixing nut (2) and clea­ning electrode (3) from the handle (1)
(3)
1
(2)
EN
(1)
Fig. 8 Undoing the fixing nut
4
(3)
3
(2)
Fig. 9 Unscrewing the cleaning electrode
3. Unscrew the cleaning electrode (3) from the fixing nut (2)
17
Page 30
Fitting the clea­ning electrode
1
(1)
1
2
1
(2)
Fig. 10 Screwing the cleaning electrode into the
fixing nut
1. Screw the new cleaning electrode (1) as far as it will go into the fixing nut (2)
2. Now unscrew the cleaning electrode (1) by about 1 turn
4
4
(1)
(2)
3
5
3
(3)
Fig. 11 Tightening the fixing nut (finger-tight)
Important! Do not tighten the fixing nut yet when screwing it onto the handle, as the cleaning electrode still needs to be adjusted!
3. Screw the fixing nut (2) and cleaning electrode (1) onto the handle (3)
4. Adjust the cleaning electrode (1) according to the application
5. Tighten the fixing nut (2) on the handle (3) (finger-tight only, do not use a tool)
18
Page 31
Ersatzteilliste
DEENFRITESPT-BRNLNOCSRUSKSVTR
Spare Parts List
Liste de pièces de rechange
Lista parti di ricambio
Lista de repuestos
Lista de peças sobresselentes
Onderdelenlijst
Reservdelsliste
Seznam náhradních dílů
Список запасных частей
Zoznam náhradných dielov
Reservdelslistan
ud_fr_st_tb_00150 012014
Parça Listesi
Wykaz czesci zamiennych
PL
Page 32
MagicCleaner Stand Alone 4,075,092 MagicCleaner Stand Alone Japanese 4,075,092,360 MagicCleaner Stand Alone 100-115/230V 4,075,092,361
42,0406,0295
45,0200,0943
42,0411,8015 - RED 1L 42,0411,8052 - RED 3L 42,0411,8018 - BLUE 1L
33,0030,0054
43,0006,0161
42,0100,0416
32,0300,2243
42,0407,0445
40,0001,0009
32,0300,7004
42,0411,8041
42,0411,8045
42,0407,0357
BE2,0200,9111
12,0405,0184
42,0411,8014
44,0450,0901
44,0550,0117
43,0004,0519
43,0004,1750
42,0300,0648
BE2,0200,9176
43,0001,3233
42,0406,0252
42,0406,0322
42,0406,0217
41,0009,0060
43,0001,0947 - MC LT3
43,0004,0533
12,0405,0184
BE2,0200,9109
43,0003,0040
MagicCleaner
Ersatzteilliste / Spare parts list / Listes de pièces de rechange / Lista de repuestos / Lista de pecas sobresselentes / Lista dei Ricambi
el_fr_st_cn_00073 012006
1/1
Page 33
6
2-3
451
POS. BENENNUNG ARTICLE DENOMINATION
1 PRINTFILZ FÜR MAGIC CLEANER PRINT- FELT FOR MAGIC CLEANER IMPRIMER FEUTRE POUR MAGIC CL. 42.0300.7030 2 ELEKTROLYT PRINTEN 0,5 L ELECTROLYTE PRINT 0,5L ELECTROLYTE DE IMPRIMER 0,5L 42.0411.8021 3 ELEKTROLYT PRINTEN 1,0 L ELECTROLYTE PRINT 1,0L ELECTROLYTE DE IMPRIMER 1,0L 42.0411.8022 4 PRINTFOLIE EINWEG 65X195 MM PRINT FOIL 65X195 MM IMPRIMER FEUILLE MET. 65X195 M 42.0411.8023 5 KUNSTSTOFFDOSE F.MAGIC-CLEANER PLASTIC-BOX F.MAGIC CLEANER PLASTIQUE-BAC MAGIC GLEANER 42.0411.8012
6 ERSATZTEILBOX M.SCHAUMSTOFF SPARE PART BOX WITH INLET BOITE CONSOMMABLES 42.0409.2638
PRINT - SET 1 MAGIC CLEANER 4,100,212
Ersatzteilliste / Spare parts list / Listes de pièces de rechange / Lista de repuestos / Lista de pecas sobresselentes / Lista dei Ricambi
el_fr_st_cn_00175 012000
1/1
Page 34
Hose pack Magic Cleaner
4,045,818
43,0002,0360
42,0300,7102
42,0401,0879
34,0350,2095
44,0001,1313
42,0100,0420
42,0001,2886
42,0402,0094
42,0402,0157
40,0001,0412
- specify length
old version
44,0001,1176 44,0450,1922
42,0001,2886
42,0402,0094
42,0400,1002
40,0001,0034
40,0001,0314
42,0402,0134
- specify length
- specify length
44,0350,1834
42,0407,0457
42,0404,0308
42,0201,0007
42,0001,5602
42,0411,8040
44,0450,1923
44,0450,1924
42,0435,0212
42,0435,0192
42,0407,0457
42,0404,0308
42,0201,0007
44,0450,1019
32,0405,0203
42,0411,8007
42,0411,8014
42,0407,0457
42,0404,0308
42,0201,0007
40,0001,0072 specify length
43,0004,1753
43,0004,1704 specify length
43,0004,2522 specify length
Hose pack
Ersatzteilliste / Spare parts list / Listes de pièces de rechange / Lista de repuestos / Lista de pecas sobresselentes / Lista dei Ricambi
el_fr_st_vp_00109 012017
1/1
Page 35
FRONIUS INTERNATIONAL GMBH
Froniusplatz 1, A-4600 Wels, Austria
Tel: +43 (0)7242 241-0, Fax: +43 (0)7242 241-3940
E-Mail: sales@fronius.com
www.fronius.com
Under http://www.fronius.com/addresses you will find all addresses
www.fronius.com/addresses
of our Sales & service partners and Locations.
ud_fr_st_so_00082 012011