/ Battery Charging Systems / Welding Technology / Solar Electronics
EN-US
ES
FR
Display
Installation instructions
Inverter for grid-connected photovoltaic systems
instrucciones de instalación
Inversores para instalaciones fotovoltaicas acopladas a la red
Instructions d'installation
Onduleur pour installations photovoltaïques connectées au réseau
42,0410,1862003-06052013
0
Dear reader,
IntroductionThank you for the trust you have placed in our company and congratulations on buying this
high-quality Fronius product. These instructions will help you familiarize yourself with the
product. Reading the instructions carefully will enable you to learn about the many different
features it has to offer. This will allow you to make full use of its advantages.
Please also note the safety rules to ensure greater safety when using the product. Careful
handling of the product will repay you with years of safe and reliable operation. These are
essential prerequisites for excellent results.
General .................................................................................................................................................5
Utilization in Accordance with "Intended Purpose" ...............................................................................6
General ......................................................................................................................................................9
Required tools and material ..................................................................................................................10
Open the inverter .......................................................................................................................................11
Open the inverter ..................................................................................................................................11
Closing and turning on the inverter ............................................................................................................13
Close inverter and switch on.................................................................................................................13
EN-US
3
4
Safety rules
EN-US
Safety Rules Explanation
General
DANGER! Indicates an imminently hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING! Indicates a potentially hazardous situation which, if not avoided, will
result in death or serious injury.
CAUTION! Indicates a potentially harmful situation which, if not avoided, may result in minor and moderate injury or property damage.
NOTE! Indicates a risk of flawed results and possible damage to the equipment.
IMPORTANT! Indicates tips for correct operation and other particularly useful information.
It does not indicate a potentially damaging or dangerous situation.
If you see any of the symbols depicted in the "Safety rules," special care is required.
The device is manufactured using state-of-the-art technology and according
to recognized safety standards. If used incorrectly or misused, however, it can
cause
-injury or death to the operator or a third party,
-damage to the device and other material assets belonging to the operator,
-inefficient operation of the device
All persons involved in commissioning, maintaining and servicing the device
must
-be suitably qualified,
-have knowledge of and experience in dealing with electrical installations
and
-read and follow these operating instructions carefully
The operating instructions must always be at hand wherever the device is being used. In addition to the operating instructions, attention must also be paid
to any generally applicable and local regulations regarding accident prevention and environmental protection.
All safety and danger notices on the device
-must be kept in a legible state
-must not be damaged/marked
-must not be removed
-must not be covered, pasted or painted over
For the location of the safety and danger notices on the device, refer to the
section headed "General" in the operating instructions for the device.
Before switching on the device, remove any faults that could compromise
safety.
Your personal safety is at stake!
5
Utilization in Accordance with
"Intended Purpose"
The device is to be used exclusively for its intended purpose.
Utilization for any other purpose, or in any other manner, shall be deemed to
be "not in accordance with the intended purpose." The manufacturer shall not
be liable for any damage resulting from such improper use.
Utilization in accordance with the "intended purpose" also includes
-carefully reading and obeying all the instructions and all the safety and
danger notices in the operating instructions
-performing all stipulated inspection and servicing work
-installation as specified in the operating instructions
The following guidelines should also be applied where relevant:
-Regulations of the utility regarding energy fed into the grid
-Instructions from the solar module manufacturer
Environmental
Conditions
Qualified Service
Engineers
Operation or storage of the device outside the stipulated area will be deemed
as "not in accordance with the intended purpose." The manufacturer is not responsible for any damages resulting from unintended use.
For exact information on permitted environmental conditions, please refer to
the "Technical data" in the operating instructions.
The servicing information contained in these operating instructions is intended
only for the use of qualified service engineers. An electric shock can be fatal.
Do not perform any actions other than those described in the documentation.
This also applies to those who may be qualified.
All cables and leads must be secured, undamaged, insulated and adequately
dimensioned. Loose connections, scorched, damaged or inadequately dimensioned cables and leads must be immediately repaired by authorized personnel.
Maintenance and repair work must only be carried out by authorized personnel.
It is impossible to guarantee that externally procured parts are designed and
manufactured to meet the demands made on them, or that they satisfy safety
requirements. Use only original replacement parts (also applies to standard
parts).
Do not carry out any modifications, alterations, etc. without the manufacturer's
consent.
Components that are not in perfect condition must be changed immediately.
Safety Measures
at the Installation
Location
6
When installing devices with openings for cooling air, ensure that the cooling air can enter
and exit unhindered through the vents. Only operate the device in accordance with the degree of protection shown on the rating plate.
EMC Device Classifications
Devices in emission class A:
-Are only designed for use in industrial settings
-Can cause line-bound and radiated interference in other areas
Devices in emission class B:
-Satisfy the emissions criteria for residential and industrial areas.
This is also true for residential areas in which the energy is supplied from the public low-voltage grid.
EMC device classification as per the rating plate or technical data.
EN-US
EMC Measures
Electrical Installations
Protective Measures against
ESD
In certain cases, even though a device complies with the standard limit values
for emissions, it may affect the application area for which it was designed (e.g.,
when there is sensitive equipment at the same location, or if the site where the
device is installed is close to either radio or television receivers). If this is the
case, then the operator is obliged to take appropriate action to rectify the situation.
Electrical installations must only be carried out according to relevant national
and local standards and regulations.
Danger of damage to electrical components from electrical discharge. Suitable
measures should be taken to protect against ESD when replacing and installing components.
Safety Measures
in Normal Operation
Only operate the device when all protection devices are fully functional. If the
protection devices are not fully functional, there is a risk of
-injury or death to the operator or a third party,
-damage to the device and other material assets belonging to the operator,
-inefficient operation of the device
Any safety devices that are not functioning properly must be repaired by authorized personnel before the device is switched on.
Never bypass or disable protection devices.
7
Safety Symbols
Devices marked with the UL test mark satisfy the requirements of the relevant
standards for the USA.
Devices marked with the CSA test mark satisfy the requirements of the relevant standards for Canada and the USA.
Disposal
Backup
Copyright
Do not dispose of this device with normal domestic waste! To comply with the
European Directive 2002/96/EC on Waste Electrical and Electronic Equipment and its implementation as national law, electrical equipment that has
reached the end of its life must be collected separately and returned to an approved recycling facility. Any device that you no longer require must be returned to your dealer, or you must locate the approved collection and recycling
facilities in your area. Ignoring this European Directive may have potentially
adverse affects on the environment and your health!
The user is responsible for backing up any changes made to the factory settings. The manufacturer accepts no liability for any deleted personal settings.
Copyright of these operating instructions remains with the manufacturer.
Text and illustrations are technically correct at the time of going to print. The
right to make modifications is reserved. The contents of the operating instructions shall not provide the basis for any claims whatsoever on the part of the
purchaser. If you have any suggestions for improvement, or can point out any
mistakes that you have found in the operating instructions, we will be most
grateful for your comments.
8
General
EN-US
Safety
WARNING! An electric shock can be fatal. Danger from grid voltage and DC volt-
age from solar modules.
-All electrical installations must be carried out in accordance with the National
Electrical Code, ANSI/NFPA 70, and any other codes and regulations applicable to the installation site.
-For installations in Canada, the installations must be carried out in accordance with applicable Canadian standards.
-The connection area should only be opened by an authorized electrician.
-The power stage set area should only be opened by Fronius-trained service
technicians.
Never work with live wires! Prior to all connection work, make sure that the AC
and DC wires are not charged.
WARNING! An electric shock can be fatal. Danger from residual voltage from capacitors.
You must wait until the capacitors have discharged. Discharging time lasts 5 minutes.
Using a suitable measurement device, ensure that the capacitors have fully discharged.
WARNING! Incorrect operation and work performed incorrectly can cause serious injury and damage! Only qualified staff are authorized to install your inverter
and only within the scope of the respective technical regulations. Do not start operation or carry out servicing and repair tasks before you have read the chapter
"Safety Instructions."
ESD Guidelines
NOTE! Observe ESD guidelines when handling electronic components and PC
boards. This primarily applies to ESD-compatible
-Packaging
-Work surfaces
-Floors
-Seating
-Grounding options
-Handling
No guarantee or warranty claims can be made in respect of any improperly handled electronic component or PC board.
9
Display
Required tools
and material
-TX25 Torx screwdriver
-Socket wrench size 8 mm / 5/16 in.
-Small slot screwdriver
-Hand torque wrench
-Bit insert TX25
-Socket wrench insert size 8 / 5/16 in. mm
10
Open the inverter
1
5
(6)(9)
EN-US
Open the inverter
WARNING! An electric shock can be fatal. Danger from grid voltage and DC volt-
age from solar modules. Prior to all work on the inverter, make sure that the AC
and DC wires are not charged.
(1)(2)(3) (4) (5)(6) (7) (8)
If present, turn off external AC and DC
disconnectors
Open cover (1)
2
Switch AC disconnector (4) and DC
3
disconnector (5) to position "OFF"
Remove 4 TX25 screws (2), (3), (7)
4
and (8)
Lift cover with display (6)
Disconnect the ribbon cable (9) from
6
the inverter
Remove cover with display (6)
7
CAUTION! An inadequate grounding conductor connection can cause serious injuries to persons and damage to (or loss of) property. The housing screws provide
an adequate grounding conductor connection for the housing ground and should
not be replaced under any circumstances by other screws that do not provide a
proper grounding conductor connection.
11
Replace display
3
Remove display
(1)(2)
(3)(4)(5)
Install displayIf present, remove the protective film from the display
1
(1)(2)
Remove 4 plastic spacers (1) - (3) and
1
(5), size 8 mm / 5/16 in.
Remove plastic film (4)
2
Remove display
3
Insert display into cover
2
IMPORTANT! When inserting the display, ensure that each individual key
tappet is threaded into the respective
key.
If necessary, use a small slot screwdriver to thread the key tappets into the
keys.
Position the plastic film (4) over the display
Fix the display and plastic film (4) in
4
(3)(4)(5)
place using 4 plastic spacers (1) - (3)
and (5), size 8 mm / 5/16 in.
Tightening torque = 0.2 Nm / 0.15 ft. lb.
Check function of keys:
5
-It must be possible to press each
key without any difficulty;
-It must be possible to press all 4
keys in the same way;
-Each key must spring back;
-Visually inspect from the side to
make sure the key tappets are
threaded into the keys.
and (16)
Tightening torque = 2.5 Nm / 1.84 ft. lb.
Switch AC disconnector (13) and DC
5
disconnector (14) to "ON" position
Close cover (10)
If present, turn on external AC and DC
7
disconnectors
(10)(11)
(12)(13)
CAUTION! An inadequate grounding conductor connection can cause serious injuries to persons and damage to (or loss of) property. The housing screws provide
an adequate grounding conductor connection for the housing ground and should
not be replaced under any circumstances by other screws that do not provide a
proper grounding conductor connection.
(14)(8) (15)
(16)
13
Loading...
+ 33 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.